TEST REPORT. Information technology equipment

Similar documents
TEST REPORT Title 47-Telecommunication

D. Guarnone (verifier)

TEST REPORT. EN / EN Information technology equipment Radio disturbance / Immunity characteristics Limits and methods of measurement

EMC test report AU01+E04

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC standards. Presented by: Karim Loukil & Kaïs Siala

TEST REPORT... 1 CONTENT...

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

EMC Test Report. Report Number: M030826

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

1 SUMMARY OF STANDARDS AND RESULTS

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

Test Report GUANGDONG EAST POWER CO., LTD

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

CENTRE OF TESTING SERVICE INTERNATIONAL

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

EMC Test report for LED Panel Light Models , , , , ,

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 EMC TEST REPORT. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

BS EN TESTS ON THE RS-485 FFP2 THE BRAIN REVISION C

2620 Modular Measurement and Control System

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

CE-EMC TEST REPORT. Prepared for : Kinglumi Co., Ltd. Bldg 3, Nangang 3nd Industrial Zone, Tangtou, Shiyan Town, Bao an District, Shenzhen City, China

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

Test Report GUANGDONG EAST POWER CO., LTD

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

PT. SARANA KARYA SOLUSINDO.

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

EMC Test Report. Shenzhen JT Detection Technology Co., Ltd. Product : Car LED headlight bulbs Brand Name :WEIYAO AUTO LED.

TEST REPORT EMC. 1, Mikhaila Kotzubinskogo St., Kyiv, Ukraine, IECCISPR14_1&2_IEC61000_3_2&3B

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

EMC TEST REPORT For CE

BUREAU VERITAS. itaste svd

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

r(oilgln TEST REPORT 'AGREB 6 %P\l Br EMC10001 sasa Gros, B.s"{h-$ INSTITUTE EMC and Safetv Laboratorv

ENGINEERING TEST REPORT #: A LSR JOB #: C-2411

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S

ELECTRONICS TESTING CENTER(ETC), TAIWAN

EMC TEST REPORT. Report No.: CE10-LIE040101E

EMI -- T E S T R E P O R T

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U

Test Report. Electromagnetic Compatibility Testing

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58

LAB engineer Milivoje Miletić

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

Declaration of Conformity.

EMC T E S T R E P O R T

EMI T E S T R E P O R T

CE-EMC TEST REPORT. Test report On Behalf of MAZi Security Systems GmbH For TVI CCTV Camera Model No.: TDE-11S; Serial Model See Page 2

TEST REPORT... 1 CONTENT...

Report on the EMC Testing. For. Exception EMS Ltd. RBK-ILS Processor. Report No. TRA A. 29 th April 2016

EMC Test report for Plug-in adaptor Models PM1Wab-ccc

Transcription:

TEST REPORT Information technology equipment Report Reference No.... 272750TRFEMC Tested by G. Bazzi (project handler)... (name, function and signature)... Approved by G. Curioni (name, function and signature)... (verificator) Date of issue... 2014-11-07 Testing Laboratory... Nemko Spa Address... Via del Carroccio, 4 20853 Biassono (MB) Italy Testing location Nemko Spa Address... Via del Carroccio, 4 20853 Biassono (MB) Italy Applicant s name... Novasis Ingegneria Srl Address... Via Orbassano 2/A 10048 Vinovo (TO) - Italy P.IVA 08984220015 Test specification: EN 55022 (2010) EN 55024 (2010) Standard... EN 61000-3-2 (2006) + A1 (2009) + A2 (2009) EN 61000-3-3 (2008) Full application of the standards Partial application of the standards Test procedure... Nemko WM L0077, WM L0177 and WM L1002 Test Report Form No.... 55022-24TRFEMC TRF Originator... Nemko Spa Master TRF... 2014-03 Nemko Spa, 20853 Biassono (MB), Italy. All rights reserved. This publication may be reproduced in whole for non-commercial purposes as long as Nemko Spa is acknowledged as copyright owner and source of the material. Nemko Spa takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description... Industrial SOM computing solution Trade Mark... NOVAsom, product Line NOVAsom6/7/8 Manufacturer... Novasis Ingegneria Srl Address of manufacturer... Via Orbassano 2/A 10048 Vinovo (TO) - Italy P.IVA 08984220015 Model... NOVAsom8 Ratings... 6,5-30 Vcc/ARM Cortex A9 1GHz This test report may not be partially reproduced, except with the prior written permission of Nemko Spa The test report merely corresponds to the tested sample. The phase of sampling / collection of equipment under test is carried out by the customer. This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.

Test Report No. : 272750TRFEMC 2014-11-07 Date of issue Short description of the EuT The EuT (NOVAsom8) is a module card designed with a System On Module (SOM) architecture dased on quad core ARM Cortex- A9, 64 bit memory until 2 GB and 3 graphic engines. Copy of marking plate Number of tested samples: 1 Serial number: Internal highest frequency generated or used: A000048 1GHz Classification of the E.U.T.: Class A Class B Device type: Accessories and detachable parts included: Other options included: - Testing Built-in Date of receipt of test sample: 2014-10-31 Testing commenced on: 2014-10-31 Testing concluded on: 2014-11-03 Possible test case verdicts: test case does not apply to the test object: test object does meet the requirement: test object does not meet the requirement: Symbols used in this test report The E.U.T. is composed of a single unit N (Not applicable) P (Pass) F (Fail) The crossed square indicates that the listed condition or equipment is applicable for this report. The empty square indicates that the listed condition or equipment is not applicable for this report. The results contained in this report reflect the results for this particular model and serial number. It is the responsibility of the manufacturer to ensure that all production models meet the intent of the requirements detailed within this report. Verdict according to the standards on page 5: Pass Page 2 of 34

PROJECT HISTORY Report number Modification to the report / comments Date 272750TRFEMC First release 2014-11-07 -- -- -- -- -- -- -- -- -- REMARKS PRODUCT VARIANTS Variant model Difference against the main model Additional test performed -- -- -- -- -- -- -- -- -- -- -- -- REMARKS Page 3 of 34

Contents 1 T E S T S T A N D A R D S 5 2 S U M M A R Y O F T E S T R E S U L T S 6 3 E Q U I P M E N T U N D E R T E S T 7 3.1 POWER SUPPLY SYSTEM UTILISED 7 3.2 EUT OPERATION MODES 7 3.3 EUT CONFIGURATION MODES 7 3.4 INPUT/OUTPUT PORTS 7 3.5 EQUIPMENT USED DURING TEST 8 3.6 PERFORMANCE LEVEL 8 4 T E S T E N V I R O N M E N T 9 4.1 ADDRESS OF THE TEST LABORATORY 9 4.2 ENVIRONMENTAL CONDITIONS 9 4.3 TEST EQUIPMENT USED FOR THE MONITORING OF THE ENVIRONMENTAL CONDITIONS 9 4.4 STATEMENT OF THE MEASUREMENT UNCERTAINTY 9 5 T E S T C O N D I T I O N S A N D R E S U L T S 1 1 5.1 RADIATED DISTURBANCE IN THE FREQUENCY RANGE 30 MHZ TO 6000 MHZ 11 5.2 CONDUCTED DISTURBANCE IN THE FREQUENCY RANGE 150 KHZ TO 30 MHZ 20 5.3 IMMUNITY TO POWER-FREQUENCY MAGNETIC FIELDS 24 5.4 IMMUNITY TO RADIO-FREQUENCY ELECTROMAGNETIC FIELDS (AM) 26 5.5 IMMUNITY TO ELECTROSTATIC DISCHARGES 28 5.6 IMMUNITY TO RADIO-FREQUENCY CONTINUOUS CONDUCTED 30 5.7 IMMUNITY TO ELECTRICAL FAST TRANSIENTS 32 6 E U T P H O T O S 3 4 Page 4 of 34

1 T E S T S T A N D A R D S The tests were performed according to following standards and procedures. NEMKO WM L0177: General routines for using instruments at Nemko NEMKO WM L1002: Measurement Uncertainty - Policy and Statement NEMKO WM L0077: General routines to perform EMC tests The following standards are covered by ACCREDIA accreditation: EN 55022 (2010) Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement EN 55024 (2010) Information technology equipment - Immunity characteristics - Limits and methods of measurement EN 61000-3-2 (2006) + A1 (2009) + A2 (2009) Electromagnetic compatibility (EMC) Part 3-2: Limits Limits for harmonic current emissions (equipment input current 16 A per phase) EN 61000-3-3 (2008) Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection The main standard(s) above contains references to other standards, which are listed below. EN 61000-4-2 (2009) Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase) EN 61000-4-3 (2006) + A1 (2008) + A2 (2010) Electromagnetic compatibility (EMC) -- Part 4-3: Testing and measurement techniques - Radiated, radiofrequency, electromagnetic field immunity test EN 61000-4-4 (2004) Electromagnetic compatibility (EMC) -- Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test EN 61000-4-5 (2006) Electromagnetic compatibility (EMC) -- Part 4-5: Testing and measurement techniques - Surge immunity test EN 61000-4-6 (2009) Electromagnetic compatibility (EMC) -- Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields EN 61000-4-8 (2010) Electromagnetic compatibility (EMC) -- Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test EN 61000-4-11 (2004) Electromagnetic compatibility (EMC) -- Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests Page 5 of 34

2 S U M M A R Y O F T E S T R E S U L T S EN 55022, EN61000-3-2, EN 61000-3-3 Requirement Test Frequency range Verdict Radiated disturbance 30 MHz to 6000 MHz P Conducted disturbance at mains ports 150 khz to 30 MHz P Conducted disturbance at telecommunication ports 150 khz to 30 MHz N Harmonic current emissions 0 khz 2 khz N Voltage changes, voltage fluctuations and flicker 50 Hz N EN 55024 Requirement - Test Ref standard Verdict Enclosure port Electrostatic discharges EN 61000-4-2 P Enclosure port Radio-frequency electromagnetic field (AM) EN 61000-4-3 P Input AC power port Electrical fast transients EN 61000-4-4 N Input DC power port Electrical fast transients EN 61000-4-4 P Signal and telecommunication ports Electrical fast transients EN 61000-4-4 P Input AC power port Surges EN 61000-4-5 N Input DC power port Surges EN 61000-4-5 N Signal and telecommunication ports Surges EN 61000-4-5 N Input AC power port Radio-frequency continuous conducted EN 61000-4-6 N Input DC power port Radio-frequency continuous conducted EN 61000-4-6 P Signal and telecommunication ports Radio-frequency continuous conducted EN 61000-4-6 P Enclosure port Power-frequency magnetic field EN 61000-4-8 P Input AC power port Voltage dips EN 61000-4-11 N Input AC power port Voltage interruptions EN 61000-4-11 N GENERAL REMARKS Class A ITE is a category of all ITE which satisfies the class A ITE limits but not the class B ITE limits. The following warning shall be included in the instructions for use: Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Immunity tests on Input DC power port are not request for equipment marketed with a AC/DC power converter. If DC power is fed on conductors included in a signal cable, then the requirements for signal and telecommunication ports only apply to this cable. For more informations see the remarks in the tests sections. Page 6 of 34

3 E Q U I P M E N T U N D E R T E S T 3.1 Power supply system utilised Power supply voltage: 230V/50 Hz / 1φ 115V/60Hz / 1φ 400V/50 Hz 3PE 400V/50 Hz 3NPE 12 V DC 24 V DC 3.2 EuT operation modes Mode 1 Normal working Description 3.3 EuT Configuration modes Emission: the EuT was configured to measure its highest possible radiation level. The test modes selected are according to EuT instruction manual. Immunity: the EuT was configured to have its highest possible susceptibility against tested phenomena. The test modes selected are according to EuT instruction manual. Mode 1 Powered 12 vdc Description 3.4 Input/Output Ports Port Name Type* Cable Cable Max. >3m Shielded Description 0 Enclosure N/E 1 Mains 12 vdc DC Two wires cable 2 HDMI I/O Terminated on Monitor switched-off 3 LAN I/O Not terminated *Note: AC = AC Power Port DC = DC Power Port N/E = Non-Electrical I/O = Signal/Control Input or Output Port TP = Telecommunication Ports Page 7 of 34

3.5 Equipment Used During Test Use* Product Type Manufacturer Model Comments Note: * Use EUT - Equipment Under Test AE - Auxiliary/Associated Equipment (Not Subjected to Test) SIM - Simulator (Not Subjected to Test) 3.6 Performance level The test results shall be classified in terms of the loss of function or degradation of performance of the equipment under test, relative to a performance level defined by its manufacturer or the requestor of the test, or agreed between the manufacturer and the purchaser of the product. Definition related to the performance level: based on the used product standard based on the declaration of the manufacturer, requestor or purchaser Criterion A: Definition: During and after the test the EUT shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed below a minimum performance level specified by the manufacturer when the EUT is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user may reasonably expect from the EUT if used as intended. Representative parameter Power on Normal working Acceptable level Green LED ON Yellow LED blinking Criterion B: Definition: After the test, the EUT shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed, after the application of the phenomena below a performance level specified by the manufacturer, when the EUT is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is allowed. However, no change of operating state or stored data is allowed to persist after the test. If the minimum performance level (or the permissible performance loss) is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user may reasonably expect from the EUT if used as intended. Criterion C: Definition: During and after testing, a temporary loss of function is allowed, provided the function is selfrecoverable, or can be restored by the operation of the controls or cycling of the power to the EUT by the user in accordance with the manufacturer s instructions. Functions, and/or information stored in non-volatile memory, or protected by a battery backup, shall not be lost. Page 8 of 34

4 T E S T E N V I R O N M E N T 4.1 Address of the test laboratory Nemko Spa Via del Carroccio, 4 20853 Biassono (MB) Italy Tests site/benches are in accordance with applicable standard/s, and have been utilized under Nemko Spa testing engineer 4.2 Environmental conditions Unless different values are declared in the test case, following ambient conditions apply for the tests: Ambient temperature: 18 33 C Relative Humidity: 30 60 % Atmospheric pressure: 980 1020 hpa 4.3 Test equipment used for the monitoring of the environmental conditions Equipment Manufacturer Model Serial N Thermohygrometer data loggers Testo 175-H2 20012380/305 Digital barometer Haenni ZED 150/111.121 900301402/0013 4.4 Statement of the measurement uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report according to CISPR 16-4-2 Specification for radio disturbance and immunity measuring apparatus and methods Part 4-2: Uncertainties, statistics and limit modelling Uncertainty in EMC measurements and is documented in the Nemko Spa Technical Procedure WML1002. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. Hereafter the best measurement capability for Nemko Spa laboratory is reported: Test Radiated Disturbance 3m, 10m Chamber Range Antenna distance 1m, 3m, 10m (30 200) MHz Antenna distance 1m, 3m, 10m (0.2 6) GHz Antenna distance 1m, 3m (6 18) GHz Antenna distance 1m, 3m (18 40) GHz Measurement Uncertainty Notes 5.0 db (1) 5.2 db (1) 5.8 db (1) 7.2 db (1) Page 9 of 34

Test Conducted Disturbance Clicks Range Measurement Uncertainty Notes 9 khz 150 khz with AMN 3.8 db (1) 150 khz 30 MHz with AMN 3.4 db (1) 150 khz 30 MHz with AAN 4.6 db (1) 9 khz 30 MHz with voltage probe 2.9 db (1) 9 khz 30 MHz with current probe 2.9 db (1) 9 khz 150 khz 3.8 db (1) 150 khz 30 MHz 3.4 db (1) Disturbance Power 30 MHz 300 MHz 4.5 db (1) Frequency 10 Hz 1 khz 0.2% (1) 1kHz 40GHz 10-6 (1) Harmonic Current Emission 50 Hz 2 khz 2% (1) Voltage Fluctuation Emission -- 2% (1) Radiated Immunity 10m, 3m chambers Radiated Immunity TEM Cell 20 MHz 6 GHz 3.4 db (1) (0.01 200) MHz 3.0 db (1) Bulk Current (1 200) MHz 3.0 db (1) Conducted RF Immunity 9 khz 230 MHz 3.0 db (1) ESD Immunity Voltage, Current, Rise time, Duration (2) (1) Burst Immunity Voltage, frequency, burst period and duration, rise time and pulse width (2) (1) Surge Immunity Voltage, Current, Rise time, Duration (2) (1) Dips Immunity Amplitude 5% (1) Duration 5% Magnetic Field Immunity 50 Hz 2.0dB (1) Damped Magnetic Field Immunity Oscillatory Wave Immunity 100 khz, 1 MHz Voltage, front time, frequency 100 khz, 1 MHz 3 db ampl. 10% freq. (1) (2) (1) Low Frequency Immunity 15 Hz 150 khz 2.2 db (1) Automotive transients Immunity Automotive transients Emission EMF Voltage, rise time, duration time Impulses 1, 2a, 2b, 3a, 3b and 4 Amplitude 10% Time 10% Lighting Equipment 26% Other Equipment 20% (2) (1) NOTES: (1) The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by the coverage factor k = 2 which has been derived from the assumed normal probability distribution with infinite degrees of freedom and for a coverage probability of 95 %; (2) The instruments used for this immunity test is according to the tolerances requested by the applicable standard (1) (1) Page 10 of 34

5 T E S T C O N D I T I O N S A N D R E S U L T S 5.1 Radiated disturbance in the frequency range 30 MHz to 6000 MHz 5.1.1 Photo documentation of the test set-up 5.1.2 Test method according to EN 55022 Measurements were made on a semi anechoic chamber. Preliminary measurements were performed at an antenna to EUT separation distance of 10 meters and 3 meters with the receive antenna located at a fixed height (from 1 to 4 meter) in both horizontal and vertical polarities. Final measurements were then performed by rotating the EUT 360 and adjusting the receive antenna height from 1 to 4 meters. All frequencies were investigated in both horizontal and vertical antenna polarity, where applicable. Page 11 of 34

5.1.3 Limits below 1 GHz for radiated disturbance of class B ITE at a measuring distance of 10 m Frequency (MHz) Limit (dbµv/m) - Quasi-Peak 30 TO 230 30 230 TO 1000 37 5.1.4 Limits above 1 GHz for radiated disturbance of Class B ITE at a measurement distance of 3 m Frequency (MHz) Limit (dbµv/m) - Average Limit (dbµv/m) Peak 1000 TO 3000 50 70 3000 TO 6000 54 74 5.1.5 Limits below 1 GHz for radiated disturbance of class A ITE at a measuring distance of 10 m Frequency (MHz) Limit (dbµv/m) - Quasi-Peak 30 TO 230 40 230 TO 1000 47 5.1.6 Limits above 1 GHz for radiated disturbance of Class A ITE at a measurement distance of 3 m Frequency (MHz) Limit (dbµv/m) - Average Limit (dbµv/m) Peak 1000 TO 3000 56 76 3000 TO 6000 60 80 5.1.7 Test result Verdict: P F N Frequency range: Kind of test site: Measurement distance: 30MHz - 6000MHz Semi anechoic chamber 3 and 10 m Remarks: The highest internal source of an EUT is defined as the highest frequency generated or used within the EUT or on which the EUT operates or tunes. If the highest frequency of the internal sources of the EUT is less than 108 MHz, the measurement shall only be made up to 1 GHz. If the highest frequency of the internal sources of the EUT is between 108 MHz and 500 MHz, the measurement shall only be made up to 2 GHz. If the highest frequency of the internal sources of the EUT is between 500 MHz and 1 GHz, the measurement shall only be made up to 5 GHz. If the highest frequency of the internal sources of the EUT is above 1 GHz, the measurement shall be made up to 5 times the highest frequency or 6 GHz, whichever is less. Page 12 of 34

5.1.8 Test protocol Antenna polarization: Operation mode: Configuration mode: Remarks: Horizontal 1 1 - Verdict: Pass Page 13 of 34

Page 14 of 34

Antenna polarization: Operation mode: Configuration mode: Remarks: Vertical 1 1 - Verdict: Pass Page 15 of 34

Page 16 of 34

Antenna polarization: Operation mode: Configuration mode: Remarks: Horizontal 1 1 1-6 GHz Verdict: Pass Page 17 of 34

Antenna polarization: Operation mode: Configuration mode: Remarks: Vertical 1 1 1-6 GHz Verdict: Pass Page 18 of 34

5.1.9 Test equipment used Equipment Manufacturer Model Serial N Trilog Broad Band Antenna Schwarzbeck VULB 9162 VULB 9162-025 Bilog antenna 1 18 GHz Schwarzbeck STLP 9148-123 123 Broadband preamplifier Schwarzbeck BBV 9718 9718-137 EMI receiver R&S ESU8 100202 Turn-table R&S HCT 835 803/03 Antenna mast R&S HCM 836 529/05 Controller R&S HCC 836 620/7 Semi-anechoic chamber Nemko 10m semi-anechoic chamber 530 Shielded room Siemens 10m control room 1947 Page 19 of 34

5.2 Conducted disturbance in the frequency range 150 khz to 30 MHz 5.2.1 Photo documentation of the test set-up 5.2.2 Test method according to EN 55022 Measurements were made on a ground plane that extends one meter minimum beyond all sides of the system under test. All power was connected to the system through Line Impedance Stabilization Networks (LISN). Conducted voltage measurements on mains lines were made at the output of the LISN. All tested telecommunications lines were connected to an Impedance Stabilization Network (ISN) and conducted voltage measurements on telecommunications lines were made at the output of the ISN. Where an ISN was not appropriate or available measurements were made using a Capacitive Voltage Probe and Current probe. 5.2.3 Limits for conducted disturbance at the mains ports of class B ITE Frequency (MHz) Quasi-Peak Limit (dbµv) Average 0.15 TO 0.50 66 to 56* 56 to 46* 0.50 TO 5 56 46 5 TO 30 60 50 *The limits decrease linearly with the logarithm of the frequency 5.2.4 Limits for conducted disturbance at the mains ports of class A ITE Frequency (MHz) Quasi-Peak Limit (dbµv) Average 0.15 TO 0.50 79 66 0.50 TO 30 73 60 Page 20 of 34

5.2.5 Limits of conducted common mode disturbance at telecommunication for class B equipment Frequency (MHz) Quasi-Peak Limit (dbµv) Average 0.15 TO 0.50 84 to 74* 74 to 64* 0.50 TO 30 74 64 *The limits decrease linearly with the logarithm of the frequency Frequency (MHz) Quasi-Peak Limit (dbµa) Average 0.15 TO 0.50 40 to 30* 30 to 20* 0.50 TO 30 30 20 *The limits decrease linearly with the logarithm of the frequency 5.2.6 Limits of conducted common mode disturbance at telecommunication for class A equipment Frequency (MHz) Quasi-Peak Limit (dbµv) Average 0.15 TO 0.50 97 to 87* 84 to 74* 0.50 TO 30 87 74 *The limits decrease linearly with the logarithm of the frequency Frequency (MHz) Quasi-Peak Limit (dbµa) Average 0.15 TO 0.50 53 to 43* 40 to 30* 0.50 TO 30 43 30 *The limits decrease linearly with the logarithm of the frequency 5.2.7 Test result Verdict for AC mains port: P F N Verdict for Telecommunication port: P F N Frequency range: Kind of test site: 0.15MHz - 30MHz Shielded room Remarks: - Page 21 of 34

5.2.8 Test protocol Test point: Operation mode: Configuration mode: Remarks: Positive line 1 1 - Verdict: Pass Page 22 of 34

Test point: Operation mode: Configuration mode: Remarks: Negative line 1 1 - Verdict: Pass 5.2.9 Test equipment used Equipment Manufacturer Model Serial N EMI receiver R&S ESCI 100888 LISN 9 khz 30 MHz R&S ESH2-Z5 872 460/041 Current clamp probe R&S ESH2-Z1 891 923/18 Voltage Probe Rorhbacher VP-1 2.455 Coupling/decoupling network Rohrbacher CDN 801-T2 60114 Coupling/decoupling network Rohrbacher CDN T4 24068 Shielded room Siemens Conducted emission test room 1862 Page 23 of 34

5.3 Immunity to power-frequency magnetic fields 5.3.1 Photo documentation of the test set-up 5.3.2 Test method according to EN 61000-4-8 This test is intended to demonstrate the immunity of equipment when subjected to power frequency magnetic fields. The test magnetic field is obtained by a current flowing in an induction coil; the application of the test field to the EUT is by the immersion method. 5.3.3 Test specification Test frequency: 50 Hz Continuous field intensity: 1 A/m Duration (Continuous field): 60 s each Axis Axis: x-axis y-axis z-axis 5.3.4 Test result Verdict: P F N Performance Criterion: Operation mode: 1 Configuration mode: 1 Kind of test site: A Helmholtz coils Remarks: Applicable only to equipment containing devices susceptible to magnetic fields, such as CRT monitors, Hall elements, electrodynamics microphones, magnetic field sensors, etc. Page 24 of 34

5.3.5 Test equipment used Equipment Manufacturer Model Serial N Field strength meter Vac Holaday HI-3604 86265 Transformer 240/24 V 2.5 KVA Eletras 220/24 2.459 Variac Belotti 242253004401 2.107 Helmholtz induction coil antenna G.I.E. IEC 1000-4-8 111962 Page 25 of 34

5.4 Immunity to radio-frequency electromagnetic fields (AM) 5.4.1 Photo documentation of the test set-up 5.4.2 Test method according to EN 61000-4-3 The test allows estimating of the radiated immunity of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 80 MHz to 1000 MHz. The interference is applied on the enclosure of the equipment by using transmitting antennas. Measurements are made in a fully anechoic chamber and the indicated field strength is pre-calibrated prior to placement of the system under test. Page 26 of 34

5.4.3 Test specification Frequency range: 80 to 2700 MHz 1 Field strength: 10 V/m 1 EuT - antenna separation: 2 m Modulation: AM with 80 % in depth and 1 KHz sine wave Frequency step: 1 % with 3 s dwell time Antenna polarisation: horizontal vertical Antenna position: front rear left right 5.4.4 Test result Verdict: P F N Performance Criterion: Operation mode: 1 Configuration mode: 1 Kind of test site: A Anechoic chamber Remarks: The frequency range is scanned as specified. However, when specified in Annex A of EN 55024, an additional comprehensive functional test shall be carried out at a limited number of frequencies. The selected frequencies are: 80, 120, 160, 230, 434, 460, 600, 863 and 900 MHz (±1 %). 1 According to costumer s request the radiated immunity test was made up to 2700 MHz at 10 V/m (in place of 1000 MHz at 3 V/m). 5.4.5 Test equipment used Equipment Manufacturer Model Serial N Log periodic antenna 200 1000 MHz R&S HUF-Z3 893 232/005 Biconical antenna 20 300 MHz Schwarzbeck VHBC 9133 9133-074 Microwave Horn antenna 0.8 4.2 GHz AR AT4002A 300773 RF generator 10 20000 MHz R&S SMP22 839 762/107 RF amplifier 80 1000 MHz IFI SMC100 + PS5000 1754-0696 RF amplifier 0.8 4.2 GHz AR 50S1G4A 301049 Power meter R&S NRVD 833697/027 Thermal power sensor R&S NRV-Z55 100300 Bidirectional Coaxial coupler NARDA Microline 3020A 90101 Bidirectional Coaxial coupler AR DC7144 301249 Semi-anechoic chamber Nemko 3m semi-anechoic chamber 70 Shielded room Siemens 3m control room 3 Page 27 of 34

5.5 Immunity to electrostatic discharges 5.5.1 Photo documentation of the test set-up With metallic case 5.5.2 Test method according to EN 61000-4-2 The test is intended to demonstrate the immunity of equipment subjected to static electricity discharges from operators directly and to adjacent objects. The table-top equipment under test is placed on a wooden table, 0.8 m high, standing on the ground reference plane. A horizontal coupling plane (HCP) is placed on the table. The EUT and the cables are isolated from the coupling plane by an insulating support 0.5 mm thick. The floor standing equipment is isolated from the ground reference plane by an insulating support about 0.1 m thick. The vertical coupling plane (VCP) of dimensions 0.5 m x 0.5 m is placed parallel to, and positioned at a distance of 0.1 m from, the EUT. Air discharges are applied to non-metallic parts of the system. Contact discharges are applied to all accessible metallic parts. Discharges are also applied to the Horizontal and Vertical Coupling Planes. Page 28 of 34

5.5.3 Test specification Contact discharge voltage: 4 kv Air discharge voltage: 8 kv Discharge impedance: 330 Ω / 150 pf Time between successive discharges: 1 sec Number of discharges: 10 Type of direct discharge: air discharge contact discharge Type of indirect discharge: contact discharge Polarity: positive negative 5.5.4 Test result Discharge location Horizontal coupling plane (HCP) Vertical coupling plane (VCP) Plastic parts Metallic parts Enclosure (only for metallic case configuration) Type of discharge Contact Contact Air Contact Contact Verdict: P F N Performance Criterion: B Operation mode: 1 Configuration mode: 1 Kind of test site: Laboratory Remarks: - 5.5.5 Test equipment used Equipment Manufacturer Model Serial N ESD Test system EMC Partner ESD3000 252 Page 29 of 34

5.6 Immunity to radio-frequency continuous conducted 5.6.1 Photo documentation of the test set-up 5.6.2 Test method according to EN 61000-4-6 The test allows estimating of the conducted immunity of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 khz to 80 MHz. The interference is applied on mains supply, signal line and earth connection ports by using coupling decoupling networks or a clamp. Measurements are made on a ground plane. The EUT was located 10cm above the reference ground plane and any associated I/O cables attached to the EUT are located between 30mm and 50mm above the ground plane. The indicated field is pre-calibrated prior to placement of the system under test. 5.6.3 Test specification Frequency range: 0.15 MHz to 80 MHz Test voltage: 10 V 1 Modulation: AM with 80 % in depth and 1 KHz sine wave Frequency step: 1 % with 3 s dwell time Page 30 of 34

5.6.4 Test result Coupling point Coupling and decoupling devices Verdict DC T2 P Signal and telecommunication ports 1 F203I-23mm P Verdict: P F N Performance Criterion: A Operation mode: 1 Configuration mode: 1 Kind of test site: Laboratory Remarks: The test on the signal ports and telecommunication ports is applicable only to cables which according to the manufacturer s specification supports communication on cable lengths greater than 3 m. 1 according to client s request the test was made anyway at 10 V (in place of 3 V). Remarks: The frequency range is scanned as specified. However, when specified in Annex A on EN 55024, an additional comprehensive functional test shall be carried out at a limited number of frequencies. The selected frequencies for conducted tests are: 0,2; 1; 7,1; 13,56; 21; 27,12 and 40,68 MHz (±1 %). 5.6.5 Test equipment used Equipment Manufacturer Model Serial N Coupling/decoupling network Lüthi CDN T2 P1427136163 EM injection clamp FCC F203I-23mm 121239 RF Conducted immunity test equipment EM Test CWS500 CSI V0710102305 Attenuator 6dB EM Test ATT6/75 0206-18 Shielded room Siemens Conducted immunity test room 68 Page 31 of 34

5.7 Immunity to electrical fast transients 5.7.1 Photo documentation of the test set-up 5.7.2 Test method according to EN 61000-4-4 The test is intended to demonstrate the immunity of equipment subjected to types of transient disturbances such as those originating from switching transients (interruption of inductive loads, relay contact bounce.). The bursts are applied on the mains supply port by using a coupling decoupling network and on signal and control lines ports by using a capacitive clamp. Measurements are made on a ground plane. 5.7.3 Test specification Voltage level for Input AC power port: 1 kv Voltage level for Input DC power port: 0.5 kv Voltage level for Signal and telecommunication ports: 0.5 kv Burst frequency: 5.0 khz Coupling duration: 60 s Polarity: positive negative Page 32 of 34

5.7.4 Test result Coupling point Level Coupling devices Verdict DC 0.5 kv Network P Signal and telecommunication ports 1 0.5 kv Clamp P Verdict: P F N Performance Criterion: Operation mode: 1 Configuration mode: 1 Kind of test site: B Laboratory Remarks: The test on the signal ports and telecommunication ports is applicable only to cables which according to the manufacturer s specification supports communication on cable lengths greater than 3 m. 1 according to client s request the test was made anyway. 5.7.5 Test equipment used Equipment Manufacturer Model Serial N Pulse generator EMC partner Transient 2000 849 Coupling clamp EMC partner CDN CNEFT1000-120 Page 33 of 34

LAB N 1244 6 EUT PHOTOS Page 34 of 34