DuPont Flashing Systems Installation Guidelines

Similar documents
DuPont Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines

DuPont Flashing Systems Installation Guidelines. Integral Flanged Door Before water-resistive. Version 2

DuPont Flashing Systems Installation Guidelines. Version 2

DuPont Flashing Systems Installation Guidelines. Version 2

DuPont Flashing Systems Installation Guidelines. Version 2

DuPont Flashing Systems Commercial Installation Guidelines

DuPont Flashing Systems Installation Guidelines. INstallation instructions after water-resistive. Version 2

DuPont Flashing Systems Commercial Installation Guidelines

DuPont Self-Adhered Flashing Systems Installation Guidelines

DuPont Self-Adhered Flashing Systems Products

DuPont Self-Adhered Flashing Systems Installation Guidelines

DuPont Tyvek Fluid Applied Flashing Commercial Installation Guidelines

TYPAR WEATHER PROTECTION SYSTEM TABLE OF CONTENTS. SPECIAL INSTALLATION CONSIDERATIONS Stucco** Brick** Stone Veneer** Wood Siding**

DUPONT TYVEK FLUID APPLIED FLASHING INSTALLATION GUIDELINES METHODS FOR SUPERIOR PROTECTION AGAINST AIR AND WATER INTRUSION

Eagle clad double-hung window installation instructions

Building Wrap and Flashing

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

Building Wrap and Flashing

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

Tools required by installer: Materials required by installer:

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

ForceField Air & Water Barrier System. installation instructions

How To Install Windows: Nail-Fin Application

Sun Windows General Information New Construction Hinged Door Installation Instructions

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

3M Air and Vapour Barrier 3015 Technical guide

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

Installation Instructions

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

window installation Guide wood FRaMinG New Construction

Sun Windows General Information New Construction Sliding Door Installation Instructions H F

Butyl Flash. Installation Instructions. Prep & General Conditions

DOOR INSTALLATION GUIDE WOOD FRAMING New Construction

HydroGap Drainable Housewrap: Installation Instructions

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

Flashing Materials. Rough Opening Preparation

Features & Benefits: For Use with OSI QUAD Window & Door System. Recommended For:

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

Before installation, check your local and state requirements for this type of install.

WindowSeal. Installation Instructions. Prep & General Conditions

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

All Window Installation Instruction

Show them you're an InstallationMaster, and watch your business grow. InstallationMasters Training Manual Addendum Level RLC-1

Installation of Fiberglass Windows

Self-Adhering Reflective Sheet Membrane

UNIT 5: EXTERIOR DOORS AND WINDOWS

Vinyl Windows and Doors Manufactured by Pella Corporation

Tamko. tw window & door flash Flashing Membrane PRODUCT DATA *

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023)

Norwood Windows Permaglass Fiberglass Products Installation Instruction

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

Providing 3 Layers of Protection

CFDTT-01. Control Joint Study (General)

In the 30-plus years that I ve been a remodeling contractor, I ve

Installation Recommendations for Finless Frame Doors

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nail Fin (JII025) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

Integrity Polygon and Round Top Installation and Finishing Instructions

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG

SPECIFICATION FOR. BRANZ Appraisal Certificate # 621 (2008)

INSTALLATION GUIDE WOOD PIVOTING CIRCLE/ OVAL

Installation Materials Required: Tools Required: 6" self-adhesive flashing. Shims. 3-foot level 6-foot level Tape measure 1/8" drill bit

ADVANCED WATER AND MOISTURE BARRIER SYSTEM

FMA/AAMA/WDMA Installation Update FMA Spring Conference Duck Key, Florida April 27, 2010

TAMKO. TW MOISTURE WRAP Above Grade Moisture / Air Barrier Membrane PRODUCT DATA

Installation Instructions for E-Series 2 or 4-Panel Gliding and French Gliding Patio Doors

Curtain Wall Installation Guide

INSTALLATION INSTRUCTIONS for Wood Patio Doors without Exterior Trim or Nailing Fin (JII027)

Adorn Mortarless Stone Veneer Installation Natural Concrete Products

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

United States 32" Features and Benefits of WEATHERMATE Sill Pan

PRIMED STRAND REVERSIBLE SHAKE

New Window. in an Old Opening. A leak-free installation depends on compatible materials and multiple layers of defense

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

INSTALLATION INSTRUCTIONS for Wood Patio Doors with Exterior Trim or Nailing Fin (JII026)

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Installation Instructions for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO

INSTALLATION INSTRUCTION FOR WOOD DOUBLE-HUNG AND CASEMENT WINDOWS USING WOOD BRICKMOULD OR FLAT CASING

A. Provide a comprehensive guide to the products that are used when flashing, what they are used for, and the proper way to use them.

ASSEMBLY AND INSTALLATION INSTRUCTIONS for Premium Atlantic Vinyl Patio Doors (JII018) ImPortAnt InformAtIon & glossary

Installation Instructions for Custom Wood and Fiberglass Door Systems (JII100)

INSTALLATION INSTRUCTIONS for Fiberglass Sliding Patio Doors with Applied Nailing Fin (JII104) IMPORTANT INFORMATION AND GLOSSARY

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Picture Frame Method Revised 10/24/2016

Installation Instructions for Vinyl Windows with Integral Nailing Fin (JII001)

Transcription:

Installation Instructions for Non-Flanged BEFORE Water-Resistive Barrier (WRB) is Installed DuPont Flashing Systems Installation Guidelines INSTLLTION INSTRUTIONS FOR NON-FLNGED DOOR BEFORE WTER-RESISTIVE BRRIER (WRB) IS INSTLLED FOR BUILDINGS LESS THN 5 STORIES REVISION 10/11

Table of ontents pplicable Products... 2 Necessary Materials... 2 Optional Materials... 2 Recommended Primers... 3 DuPont Recommended Low Expansion Foams... 3 DuPont Recommended Fasteners... 3 General Instructions... 3 Non-Flanged... 5 pplicable Products Flashing Products PRODUT DIMENSIONS RE DuPont FlexWrap NF* 6 in x 75 ft 37.50 sq ft 9 in x 75 ft 56.20 sq ft DuPont FlexWrap * 9 in x 75 ft 56.2 sq ft 9 in x 250 ft 187.5 sq ft DuPont StraightFlash 4 in x 150 ft 50 sq ft 9 in x 125 ft 93.75 sq ft DuPont StraightFlash VF 6 in x 125 ft 62.5 sq ft DuPont Flashing Tape 4 in x 100 ft 33.33 sq ft 6 in x 100 ft 50.2 sq ft 9 in x 100 ft 75 sq ft DuPont FlexWrap RW for Single Stud pplication 9 in x 6 in 0.38 sq ft DuPont FlexWrap RW for Double Stud pplication 9 in x 6 in 0.38 sq ft * These installation instructions are applicable to both DuPont FlexWrap and FlexWrap NF which can be used interchangeably throughout the installation guide. Necessary Materials DuPont Flashing DuPont Tyvek Tape DuPont Residential Sealant, DuPont ommercial Sealant, or recommended sealant Optional Materials DuPont Tyvek Wrap aps or other recommended fasteners Brushes for Surface Preparation Backer rod J -roller Recommended Primers L shaped back dam is a 3/4 corner guard (used on interior gypsum) opyright 2011 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 10/11 2

Recommended Primers* MNUFTURER PRODUT NME 3M Hi-Strength 90 Denso Butyl Primer (spray or can) *pply per manufacturers guidelines. For non-dupont products, DuPont assumes no liability in use of recommended products; installers need to evaluate suitability of recommended products in their end-use applications. DuPont Recommended Low Expansion Foams MNUFTURER DuPont DuPont Recommended Fasteners* MNUFTURER DuPont DuPont DuPont DuPont Tyvek Wrap ap with alternate screws 1.0 inch minimum crown staples** PRODUT NME DuPont Window & Foam PRODUT NME DuPont Tyvek Wrap ap nails DuPont Tyvek Wrap ap screws DuPont Tyvek Wrap ap staples (for Stinger or rossfire cap stapler)** * pply per manufacturers guidelines. For non DuPont products, DuPont assumes no liability for use of recommended products; installers need to evaluate suitability of recommended products in their end-use applications. ** Except when installing DuPont Tyvek WRBs over foam sheathing and other non-nail-base sheathings. Warranty Please see DuPont Weatherization Products Limited Warranty for buildings less than 5 stories at www.weatherization.tyvek.com. General Instructions For buildings less than 5 stories For performance requirements exceeding STM E1677, 65 mph equivalent structural load and 15 mph equivalent wind-driven rain water infiltration for buildings less than 5 stories, or for installations that specify a window/door design rating of DP45 or greater, it is recommended to install a high pressure skirt to help prevent water intrusion at the sill or threshold and follow the DuPont Flashing Systems ommercial Installation Guidelines. DuPont Flashing Systems products should be installed on clean, dry surfaces that are free of frost. Wipe surfaces to remove moisture, dirt, grease and other debris that could interfere with adhesion. When cutting the Water-Resistive Barrier (WRB) to prepare the opening, remove an additional 1 strip of the WRB head flap to allow more room for the tape adhesive to seal the head flashing. pply pressure along entire surface of flashing for a good bond using a J-roller or firm hand pressure. Remove all wrinkles and bubbles that may allow for water intrusion by smoothing surface and repositioning as necessary. When flashing the sill area for windows and doors, DuPont recommends the use of 6 wide DuPont Flexwrap NF for 2 x 4 framing and 9 wide DuPont Flexwrap NF for 2 x 6 framing. s an option, if a rigid back dam is desired, cut the corner back dam the length of the sill and nail into place on the interior edge of the sill prior to installation of DuPont Flexwrap NF. Then install DuPont Flexwrap NF over sill and corner guard back dam. If using 6 DuPont FlexWrap NF with optional rigid back dam, seal ends of corner guard with DuPont Residential Sealant, DuPont ommercial Sealant, or recommended sealant. opyright 2011 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 10/11 3

and window rough sill framing must be level or slightly sloped to the exterior to ensure proper drainage to the exterior. This best practice ensures continuous support with positive slope to the exterior. DuPont Residential Sealant and DuPont ommercial Sealant should be tooled flat to allow the natural curing process to create a concave joint. Please contact your local DuPont Tyvek Specialist for additional information and installation support. DO NOT STRETH DuPont FlexWrap NF when installing along the length of sills or jambs. DuPont FlexWrap NF is only intended to be extended when covering corners or curved sections. These installation instructions are applicable to both DuPont FlexWrap NF and FlexWrap which can be used interchangeably throughout the installation guide. However, DuPont FlexWrap must be secured with recommended fasteners as shown in the illustration at right. DuPont Flashing Systems products perform best when installed at temperatures above 25 F ( 4 ). DuPont Flashing Systems products should not be installed over cap fasteners. Priming is generally not required for adhering DuPont Flashing Systems products to most common building materials. However, adverse weather conditions or cold temperatures may require use of a primer to promote adhesion. dditionally, concrete, masonry, and glass mat gypsum sheathing require the use of approved primers. For primer recommendations, see page 3. For additional guidelines, please call 1-800-44-Tyvek (800-448-9835), visit our website at www.weatherization.tyvek.com, or consult your local DuPont Tyvek Specialist. opyright 2011 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 10/11 4

Non-Flanged BEFORE Water-Resistive Barrier (WRB) Is Installed This installation guide is intended for doors installed above grade and with wood floor construction. Method applies to the following products: DuPont StraightFlash, DuPont StraightFlash VF, DuPont FlexWrap NF, and DuPont Flashing Tape STEP 1 ttach apron made of DuPont Tyvek WRB under sill (S). pron should extend at least 10 beyond sides of rough opening jambs (or to first stud in open stud construction), and far enough below the rough opening to overlap the sill plate or the DuPont Tyvek WRB below. The top of the apron should be securely attached to the wall and the bottom of the apron should be left unsecured so it can overlap the DuPont Tyvek WRB which will be installed after the door. 10 (S) opyright 2011 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 10/11 5

STEP 2 Preparation of sill flashing:. ut piece of DuPont FlexWrap NF at least 12 LONGER than the width of the sill (S). B. DuPont FlexWrap NF has perforated release paper to help with the formation of the back dam. To ensure that the perforation tears cleanly, fold the perforation 180 and crease the flashing.. Remove the two widest pieces of release paper leaving the narrowest release paper on the flashing. When the finished floor is applied, the release paper can be removed and the back dam can be completed. 6-inch for 2x4-inch studs 9-inch for 2x6-inch studs B Overlap Perf Break Perf Peel Off 2-pieces of Backing opyright 2011 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 10/11 6

STEP 3 (OPTIONL BK DM) Install the sill flashing as indicated leaving the 1 of DuPont FlexWrap NF with release paper extending it past the door threshold on the inside. When the 1 of release paper is removed, there should be 3/4 of flashing to form the back dam. OPTION 2: Some flooring cannot accomodate a back dam. In that case fold the 1 back dam on top of DuPont FlexWrap NF in the sill. will be installed on top of the 1 fold to create a back dam. EXTERIOR INTERIOR Threshold Transition Threshold Flooring Optional 6 5 4 1 2 3 WRONG No Gap in orner Jamb DuPont FlexWrap NF Sill ORRET DuPont StraightFlash High Pressure Skirt (See Step 8 Optional) DuPont FlexWrap NF DuPont Tyvek WRB Sheathing Sub Floor orner Guard (optional) DO NOT STRETH FRONT VIEW ORNER DETIL SIDE VIEW DETIL opyright 2011 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 10/11 7

STEP 4. Fan out DuPont FlexWrap NF at bottom corners onto the face of the wall. overage of DuPont FlexWrap NF should be 2 to 3 onto the face of the wall.. FOR NON-FLNGED DOORS ONLY STEP 5. Prepare head flashing by cutting a piece of DuPont StraightFlash VF at least twelve (12) inches LONGER than the head length. B. Remove the release paper from one side of DuPont StraightFlash VF.. enter the DuPont StraightFlash VF along the length of the door and position so that it contacts the door frame. D. Beginning at the junction of the jamb and head and away from the corners cut the DuPont Straightflash VF along the corner at a 45 angle. E. Fold the newly created flashing flaps down parallel to the door frame. F. Fold remaining head flashing onto to the jamb. D E D E F Scored Release Paper Butyl Non-Flanged VIEW - opyright 2011 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 10/11 8

STEP 6. Prepare jamb flashing by cutting a piece of DuPont StraightFlash VF at least six (6) inches LONGER than the jamb length. B. Remove the release paper from one side of DuPont StraightFlash VF.. Position so that the DuPont StraightFlash VF contacts the door frame up to the exterior face of the door. Ensure that the jamb flashing is positioned 1-1/2 inches below top of head flashing. Jamb flashing adhesive must come in contact with head flashing adhesive and overlap by one inch. D. Repeat on opposite jamb. STEP 7. Beginning at the junction of the jamb and head and at the sill and jamb and away from the corners, cut the DuPont Straightflash VF along the corners at a 45 angle and fold it over flat to adhere it against the head flashing. B. Fold newly created flap down parallel to the door frame.. Fold flashing flaps to the door frame and adhere. E Exterior D. Repeat on opposite jamb. Make sure the adhesive on these pieces will overlap. E. ut two 3 x 3 DuPont FlexWrap NF squares and add patches to corner of the door. Staple patches in corners to secure the wooden head and jambs. 3 x 3 DuPont FlexWrap NF 1-1/2 1-1/2 B B opyright 2011 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 10/11 9

FOR NON-FLNGED DOORS STEP 8 (OPTIONL - HIGH PRESSURE SKIRT) For extreme weather conditions, performance requirements exceeding STM E1677, or window/door design ratings of DP45 or greater, see General Instructions.. reate the high pressure skirt by cutting a piece of DuPont Tyvek WRB 1 wider than the width of the door opening and approximately 10 in height. B. ut a piece of DuPont StraightFlash VF to the same width of skirt. Remove release paper from one side of DuPont StraightFlash VF and adhere to the DuPont Tyvek WRB. The skirt may be made with DuPont StraightFlash VF, DuPont StraightFlash or DuPont Flashing Tape.. Remove the release paper from the other side of DuPont StraightFlash VF and adhere the butyl adhesive at the sill skirt to the underside of the door threshold behind the jamb flashing. D. Secure edges of the optional skirt with two 4 pieces of DuPont StraightFlash or DuPont Flashing Tape. E. Tape the bottom of the optional skirt to allow for drainage and to minimize wind damage during construction. F. If sealant is applied to the sill, insure (2) 2 gaps to allow for drainage for every 4 of door using DuPont Residential Sealant, DuPont ommercial Sealant, or recommended sealant. DuPont StraightFlash VF B Butyl dhesive 10 Peel Off Release Paper and attach to underside of door F D Optional High Pressure Skirt D opyright 2011 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 10/11 10 E

STEP 9. Install door according to manufacturer s installation instructions. B. Remove the remaining release paper from the DuPont StraightFlash VF jamb flashing and press firmly to adhere it to the DuPont Tyvek WRB.. Remove the release paper at the head and adhere it to the exterior sheathing or framing members. OPTIONL: over exposed butyl with DuPont StraightFlash, DuPont Flashing Tape or DuPont Tyvek Tape. STEP 10 (OPTIONL - REOMMENDED BEST PRTIE). ut a piece of metal or vinyl drip cap slightly longer than the width of the door and place a bead of DuPont Residential Sealant, DuPont ommercial Sealant, or recommended sealant on the rear side. Install the drip cap tight against the door head and cover the top edge with DuPont StraightFlash or DuPont Flashing Tape. B opyright 2011 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 10/11 11

STEP 11 fter installing the DuPont Tyvek WRB, cut as shown to expose door and apron. (Refer to the DuPont Tyvek Water-Resistive Barriers Installation Guidelines to install the DuPont Tyvek WRB properly). DO NOT UT THROUGH THE DUPONT FLSHING SYSTEMS PRODUTS OR PRON. STEP 12. Tape seams as shown. DO NOT TPE at bottom of window. t the head, continuous tape seams as shown with DuPont Tyvek Tape. Skip-taping at the head is acceptable if an air barrier is not required or if additional drainage is desired. B. Lap bottom of apron and the DuPont Tyvek WRB over building materials below for proper shingling. DO NOT UT through DuPont Flashing Systems Products or apron. opyright 2011 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 10/11 12

LTERNTE TPE DETIL Place a continuous bead of DuPont Residential Sealant, DuPont ommercial Sealant, or recommended sealant around the jamb and head flashing under the DuPont Tyvek WRB. Press the DuPont Tyvek WRB securely into the sealant. STEP 13 Final Step. When the interior flooring is ready to install, remove release paper and use Folding Option One or Two to form back dam. B. Install DuPont Residential Sealant, DuPont ommercial Sealant, or recommended sealant (and backer rod as necessary) around the window opening at the interior. It is also acceptable to use DuPont Window & Foam or recommended foam. The seal created by the sealant (and backer rod as necessary) or foam will also serve as a back dam. DuPont Residential Sealant or DuPont ommercial Sealant should be tooled flat to allow the natural curing process to create a concave shape. Be sure that the sealant penetrates the grooves of the DuPont FlexWrap NF around the sill. NOTE: Installations that specify a window/door design rating of DP45 or greater require extra precautions. See General Instructions for performance requirements exceeding this design rating. Folding Option One Folding Option Two OR Fold Out and Up Fold In and Up Fastening Option One Fastening Option Two OR Staples Tape opyright 2011 E. I. du Pont de Nemours and ompany. ll Rights Reserved. Rev. 10/11 13

Technical Specifications DuPont Tyvek WRBs used in construction products are made from 100% flash spunbonded high density polyethylene fibers which have been bonded together by heat and pressure, without binders or fillers, into a tough, durable sheet structure. dditives have been incorporated into the polyethylene to provide ultraviolet light resistance. DuPont requires that DuPont Tyvek ommercialwrap and ommercialwrap D be covered within 9 months (270 days) of installation and that all other DuPont Tyvek WRB s be covered within 4 months (120 days) of installation. DuPont Flashing Systems products are made from a synthetic rubber adhesive and a laminate of polyethylene film, polypropelene film, elastic fiber, synthetic rubber adhesive, polyurethane adhesive, and a top sheet of flash spunbonded high density polyethylene fibers or polypropelene film. dditives have been incorporated into these materials to provide ultraviolet light resistance. DuPont requires that DuPont Flashing Systems products be covered within four months (120 days) of installation. Warning DuPont Tyvek Water-Resistive Barriers are slippery and should not be used in any application where it will be walked on. In addition, because they are slippery, DuPont recommends using kickjacks or scaffolding for exterior work above the first floor. If ladders must be used, extra caution must be taken to use them safely by following the requirements set forth in NSI Standards 14.1, 14.2 and 14.5 for ladders made of wood, aluminum, and fiberglass, respectively. DuPont Tyvek products are combustible and should be protected from a flame and other high heat sources. DuPont Tyvek products will melt at 275 F (135 ); if the temperature of DuPont Tyvek products reaches 750 F (400 ), it will burn and the fire may spread and fall away from the point of ignition. For more information, call 1-800-44-Tyvek. DuPont Flashing Systems products and their release paper are slippery and should not be walked on. Remove release paper from work area immediately. DuPont Flashing Systems products will melt at temperatures greater than 250 F (121 ). DuPont Flashing Systems products are combustible and should be protected from flames and other high heat sources. DuPont Flashing Systems products will not support combustion if the heat source is removed. However, if burning occurs, ignited droplets may fall away from the point of ignition. For more information, call 1-800-44-Tyvek. DuPont Residential Sealant and DuPont ommercial Sealant are irritating to skin, eyes, and respiratory tract. For proper usage, follow directions stated on the product label. For health information, refer to the Material Safety Data Sheet or call hemtrec at 1-800-424-9300. Note When installed in conjunction with other building materials, DuPont Flashing Systems products must be properly shingled with these materials such that water is diverted to the exterior of the wall system. DuPont Tyvek products are air and water barriers and not the primary water barrier. The outer facade is the primary barrier. You must follow facade manufacturer s installation and maintenance requirements for all facade systems in order to maintain water holdout properties and ensure performance of DuPont Tyvek products. Use of additives, coatings or cleansers on or in the facade system may impact the performance of DuPont Tyvek water-resistive barriers. DuPont Tyvek Weatherization Systems products are to be used as outlined in this installation guideline. DuPont Flashing Systems products should only be used to seal penetrations and flash openings in houses or buildings. DuPont Flashing Systems products are not to be used in roofing applications. For superior protection against bulk water penetration, DuPont suggests a system combining a quality exterior facade, a good secondary weather barrier and exterior sheathing, high quality windows and doors, and appropriate flashing materials paying attention to proper installation of each component. In a system where no exterior sheathing is used and DuPont Tyvek WRB is installed directly over the wall studs, exterior facade materials should be selected to ensure maximum protection against water intrusion. areful workmanship and proper installation of each component is very important. DuPont believes this information to be reliable and accurate. This information may be subject to revision as additional experience and knowledge is gained. It is the user s responsibility to determine the proper construction materials needed on each project. For complete warranty information, please visit www.weatherization.tyvek.com or call 1-800-44-Tyvek. This information is not intended to be used by others for advertising, promotion or other publication for commercial purposes. For more information about DuPont Weatherization Systems, please call 1-800-44-Tyvek or visit us at www.weatherization.tyvek.com opyright 2011 E. I. du Pont de Nemours and ompany. ll rights reserved. The DuPont Oval Logo, DuPont, Tyvek, FlexWrap, and StraightFlash are registered trademarks or trademarks of DuPont or its affiliates. ll rights reserved. K-25727 10/11