Section lll: SM Series Spectrometer. ometers SPECTRAL PRODUCTS

Similar documents
QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

SpectraPro 2150 Monochromators and Spectrographs

Microscope-Spectrometer

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

Maya2000 Pro Spectrometer

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Specifications Summary. Register well depth (typical) Standard mode High Capacity mode High Sensitivity mode. Maximum spectra per sec 1,612

Oriel MS260i TM 1/4 m Imaging Spectrograph

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Improving the Collection Efficiency of Raman Scattering

DV420 SPECTROSCOPY. issue 2 rev 1 page 1 of 5m. associated with LN2

Symmetrical Czerny-Turner, 75 mm focal length nm nm, depending on configuration (see table)

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Specifications. Offers the best spatial resolution for multi-stripe spectroscopy. Provides the user the choice of either high accuracy slit mechanism

BaySpec SuperGamut OEM

100 khz and 2 MHz digitization rates Choose low speed digitization for low noise or high speed for fast spectral acquisition.

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available.

Optional AR coating and wedge windows are available

MS260i 1/4 M IMAGING SPECTROGRAPHS

Company synopsis. MSU series

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

JETI Specbos Instruments

LED Lighting Flux and Color Measurement System (LFC)

AvaLight-HAL-S-MINI Tungsten-Halogen Light Source

Tunable KiloArc. Tunable Broadband Light Source.

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.

Minimizes reflection losses from UV to IR; No optical losses due to multiple optical surfaces; Optional AR coating and wedge windows available.

Coating Thickness Measurement System

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

Aqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE

30 x 3.8 mm / 2000 x 256 pixel NIR Spectroscopy CCD. cooling. Specifications Summary. Active pixels 2000 x 256

AVANTES EVO SERIES THE NEXT EVOLUTIONARY STEP FOR SPECTROMETRY

sensicam em electron multiplication digital 12bit CCD camera system

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

Spark Spectral Sensor Offers Advantages

DU-897 (back illuminated)

Miniature Spectrometer Technical specifications

LED Tester BTS256-LED

We bring quality to light. CAS 120 CCD Array Spectrometer

P-CUBE-Series High Sensitivity PIN Detector Modules

TriVista. Universal Raman Solution

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

AvaLight-DHc Full-range Compact Light Source

Cornerstone 260 1/4 m Monochromators

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club

Aqualog. Water Quality Measurements Made Easy FLUORESCENCE

UM1380/ UM2380 UM1390/ UM2390 Datasheet

PGS Family Plane Grating Spectrometer from ZEISS

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

TracQ. Basic Data Acquisition and Spectroscopy Software

Photodiode Heads and Instruments

1/8 m GRATING MONOCHROMATOR

SPECTRAL SCANNER. Recycling

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

Lab Junior Educational UV-VIS Spectrometer

Pulsed Laser Power Measurement Systems

User-configured for Maximum Flexibility

VS7550 VUV/UV Mini Spectrograph Operating Manual

Data Sheet SMX-160 Series USB2.0 Cameras

ZEISS Axiocam 503 color Your 3 Megapixel Microscope Camera for Fast Image Acquisition Fast, in True Color and Regular Field of View

istar 712 Series Gen 3 - FL (HVS, -63) Gen 3 - FL (EVS, -A3) Gen 3 - FL (BGT, -C3) InGaAs (NIR, -93)

PIXIS-XO: 400B 1340 x 400 imaging array 20 x 20 µm pixels Direct detection

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45

Solid State Luminance Standards

PIXIS-XO: 1024B 1024 x 1024 imaging array 13 x 13 µm pixels

Section IX: AF Series Fibers and Fiber Couplers

ikon-m 934 DO Series

Research Grade Xenon Arc Lamp Sources LH-Series 75 W - 300W

Model Number Guide. M= Material. S= Apperture Size. P= Options

IBIL setup operation manual for SynerJY software version

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

Broadbandradiometer specbos 1211

X-Ray diffraction pattern of the Synchrotron Soleil,France. Courtesy of Vincent Jacques. Direct Detection X-Ray Imaging. Specifications Summary

Table 8 Overview light sources

pco.1600 cooled digital 14bit CCD camera system

Spectroscopy at Pace. Specifications Summary. Register well depth (typical) Standard mode High Capacity mode High Sensitivity mode

ULS24 Frequently Asked Questions

Modular Fourier Transform Infra-Red Spectrometer (FT-IR) Solution

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -

Spectrometers. Spectroscopy HOLMARC UV-VIS-IR HOLMARC OPTO-MECHATRONICS PVT.LTD HOLMARC INSTRUMENTS CONTENTS. Spectrometer Goniometer RE-02

It s Our Business to be EXACT

University of Wisconsin Chemistry 524 Spectroscopic Components *

Quantum Efficiency Measurement System with Internal Quantum Efficiency Upgrade

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems

Power Sensors Introduction

HAMAMATSU PHOTONICS K.K.

NEW. Spectroscopy at Pace. Specifications Summary 1. Register well depth (typical) Standard mode High Capacity mode High Sensitivity mode

OLYMPUS Digital Cameras for Materials Science Applications: Get the Best out of Your Microscope

Oriel Cornerstone 130 1/8 m Monochromator

We bring quality to light. MAS 40 Mini-Array Spectrometer

The CCD-S3600-D(-UV) is a

INDIAN INSTITUTE OF TECHNOLOGY-KANPUR (DEPARTMENT OF MECHANICAL ENGINEERING)

Light Sources. Tip. Light Sources

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

Variable Gain Photoreceiver Fast Optical Power Meter

We bring quality to light. Spectro 320 Scanning Spectrometer

Upgrade to Andor s high-resolution Luca EM R EMCCD; the new price/performance benchmark.

Transcription:

Section lll: SM Series ometers SPECTROMETERS SM200 OEM Packaged Fiber Optic CCD SM240 Hand-Held CCD SM241 Near Infrared Enhanced CCD AD300 Back Thinned CCD Tunable, TE Cooled SM300 Fluorencenced/Raman SM301 PbS Array SM302 InGaAs Array SM520 High Resolution CCD SM SERIES ACCESSORIES SM SERIES SOFTWARE 33

SM200 OEM packaged aged Fiber Optic CCD Best performance cost ratio in the industry. Designed from the ground up for OEM integration. Small impact resistant optical bench. Flexible light input direct to slit or via fiber. Fully customizable. ILX 511 allows up to a 700 nm measurement window between 200nm and 1050nm (800 nm measurement window size possible for some applications). USB 2.0 interface with 16-bit dynamic range available! The Choice for OEM Spectral al s The SM200 is a miniature spectrometer designed for custom OEM applications. It offers a high performance to cost ratio for new systems designs. The SM200 can accept light directly through its built-in slit or via optical fiber. A removable fiber coupler faceplate allows use of standard SMA 905, FC and custom fiber connectors. This faceplate also allows direct attachment to dedicated systems and a number of SMX. A durable aluminum housing encloses the SM200 optical bench; through careful design this housing provides stable device operation over a wide range of temperatures. The spectrometer sensor array and array driver electronics are mounted inside the SM200 housing, from there a flex cable connects to exterior support electronics. The standard sensor array used is the Sony ILX 511. The driver electronics have been designed for highly sensitive yet stable operation. The design of the SM200 also allows the use of custom arrays for special applications, including photodiode assemblies and alternative CCD arrays. Standard interfaces to the SM200 include a USB 2.0 interface with 16-bit extended dynamic range and a PCI card interface with 12-bit dynamic range sampling. Custom interfaces and legacy ISA and PCMCIA interfaces are available. Software support includes custom DLLs for dedicated applications development and our SM32Pro windows based spectral acquisition and analysis software. Both standard and legacy interface designs provide support for advanced acquisition programming and external triggering. 34

Specifications: Detectors: Sony CCD Linear Array Number of Pixels: 2048 Sensing Pixel Size: 14µm x 200µm Sensitivity: 1800 V/(lx s) @ 660nm Customer array installation available Computer Interface: USB 2.0 16 bit 500KHz PCI bus NI-PCI 12 bit 100 KHz PCI interface board Call SP for other interface options, including PCMCIA and ISA Temperature Induced Shift: 0.01 nm / C Spectrograph f#: 2.7 Available Gratings: See A Slit Options: 10, 25, 50 or 100µm Fiber Options: 50 to 600µm core diameter Fiber Coupler: SMA 905 or FC standard, custom coupler available Fiber Numerical Aperture: 0.2 Effective Spectral Range: 200 to 1050nm Order Sorting Filter: Longpass filter installed per wavelength coverage Spectral Resolution: 0.3 to 10nm depending on the slit and grating choices Stray : <0.01% at 600nm Software: SM32Pro (free with spectrometer) Includes SDK and DLLs for easy custom application development. 0.492 2.078 3.813 1.570 Ø 0.174 0.329 2.000 2.689 0.905 Ordering Information: Please indicate product number plus description when ordering. SM200 OEM Fiber Optic 35

SM240 Hand-held CCD Compact system, can be handheld or securely mounted. Flexible optical input direct to slit or via fiber. Designed from the ground up for applications. Impact resistant housing. High performance electronics. Standard design allows up to a 700nm measurement window between 200nm and 1050nm (800 nm window possible for some applications). USB 2.0 interface with 16-bit dynamic range available! The Choice for Spectral al s The SM240 is a compact CCD for use with a PC. Based on the SM200 optical bench design, it supports many different applications where spectral or color measurements are required, including high dynamic range applications. The SM240 can accept light directly through its built-in slit or via optical fiber. A removable faceplate allows the use of standard SMA 905, FC and custom fiber connectors. This faceplate also allows direct attachment to dedicated systems and a number of SMX. The durable aluminum housing that encloses the SM240 provides stable optical bench operation over a wide range of temperatures. The standard sensor array used is the Sony ILX 511. The array driver electronics have been designed for highly sensitive yet stable operation. This array (in conjunction with our special UV coating process and custom order sorting filters) allows up to a 700nm measurement window located from 200nm to 1050nm (smaller measurement window sizes increase spectral resolution and light sensitivity, some laser applications may support a window size of up to 800nm). The design of the SM240 also allows use of custom arrays for special applications, including photodiode assemblies and alternative CCD arrays. Standard interfaces to the SM240 include a USB 2.0 interface with 16-bit extended dynamic range and a PCI card interface with 12-bit dynamic range. Custom interfaces and legacy ISA and PCMCIA interfaces are available. Software support includes a SDK and DLLs for dedicated applications development and our SM32Pro Windows-based spectral acquisition and analysis software. Both standard and legacy interface designs provide support for advanced acquisition programming and external triggering. 36

Softwar are SM32Pro - Windows 98,2000, XP based software for data acquisition and analysis. Transmission, reflectance, and absorbance measurements. Data export, zoom in and out, spectrum overlays, and many more features. Color analysis tools included. Signal average and integration time control. Double beam version available. SDK and DLLs available for easy custom software development. SM240 USB OR SM240 PCI Electrical Cable Specifications: USB Interface PCMCIA Interface PCI Interface Detectors: Sony CCD Linear Array Number of Pixels: 2048 Sensing Pixel Size: 14µm x 200µm Sensitivity: 1800 V/(lx s) @ 660nm Customer array installation available Dimensions (inches): 5.6 h x 2.75 w x 0.87 d Weight: 0.5 lbs. Spectral Range: UV - 200nm to 450nm VIS - 380nm to 760nm NIR - 550nm to 1050nm other ranges are configurable from 200nm to 1050nm Spectral Resolution: 0.3-10nm dependent on spectral range, slit width, and fiber diameter. Available Gratings: See A 2.186 0.489 Entrance: Fiber 1.920 Ø 0.174 0.129 2.164 Software 3.280 0.329 SMA 905 or FC fiber coupler. 50-600µm core Ø fiber NA = 0.2 Slit 10, 25, 50 or 100µm Dynamic Range: 12 bit (4096:1) or 16 bit (65536:1) Computer Interface: USB 2.0 16 bit 500KHz PCI bus NI-PCI 12 bit 100 KHz PCI interface board Call SP for other interface options, including PCMCIA and ISA Temperature Range: 15 C to 40 C Software: SM32Pro Ordering Information: Please indicate product number plus description when ordering. 2.689 0.990 SM240 USB SM240 PCI USB interface, PCI interface, 37

SM241 NIR Laser Less expensive alternative to Germanium or InGaAs systems. Compact system, can be handheld or securely mounted. Flexible optical input direct to slit or via fiber. High performance electronics. Allows spectral measurements between 900nm and 1700nm. USB 2.0 interface with 16-bit dynamic range available! The Choice for Spectral al NIR Laser s The SM241 is a compact CCD based designed for NIR laser applications. Spectral Product s IR up-conversion phosphor CCD coating breaks the standard Silicon-based CCD detectors array sensitivity barrier of 1100nm to allow spectral measurements up to 1700nm. This technology makes the SM241 a lower cost alternative to Germanium or InGaAs systems. The SM241 optical bench includes oversized gold plated mirrors and gratings to accommodate NIR light collection and analysis. Maximum spectral coverage with this spectrometer is 900 nm to 1700 nm (reduced coverage window size within 900-1700nm will increase spectral resolution and light sensitivity). Standard interfaces include a USB 2.0 interface with a 16-bit extended dynamic range and a PCI card interface with a 12-bit dynamic range. Custom interfaces and legacy ISA and PCMCIA interfaces are also available. Software support includes a SDK and DLLs for dedicated applications development and our SM32Pro windows based spectral acquisition and analysis software. Both standard and legacy interface designs provide support for advanced acquisition programming and external triggering. 38

SM241 USB USB Interface OR SM241 PCI Electrical Cable PCMCIA Interface PCI Interface Specifications: # of CCD Pixels: 2048 CCD Pixel Size: 14µm by 200µm CCD Sensitivity: 30 V/mJ/cm 2 Grating: 300 to 1800 grooves per mm Spectral Response: 900nm to 1600nm Spectral Resolution: 5nm with standard slit configuration Available Gratings: See A Entrance: Slit 10µm - 100µm Fiber SMA fiber coupler, NA = 0.2 Stray Rejection: better than 10-3 Analog to Digital: USB 16 bit standard, PCI optional. Digitizer Resolution: 12-bit, 4096 to 1 or 16 bit, 65536 to 1 Computer Interface: USB Bus 16 bit 500KHz PCI bus NI-PCI 12 bit 100 KHz PCI interface board Call SP for other interface options Dimensions (inches): 5.5 x 2.9 x 0.99 Weight: 0.5 lbs. Software: SM32Pro Ordering Information: Please indicate product number plus description when ordering. SM241 USB Near Infrared Enhanced Hand-held, USB SM241 USB Near Infrared Enhanced Hand-held, USB 39

AD300 Back Thinned CCD Tunable unable,, TE Cooled High QE From UV To NIR Large Dynamic Range Very Low Noise 512x122 CCD Format Cooled Stable Operation Dual Grating Turret Spectrograph High Spectral Resolution Low w Level el, Tunable CCD The AD300 is a CCD spectrometer system specifically designed for low light level detection, such as fluorescence and Raman applications. The system consists of a back-thinned area CCD array, which exhibits high quantum efficiency and low noise. The array is cooled for noise reduction and long-term stable operation. The CCD is coupled to a dual grating tunable spectrograph with computer control to both select grating and wavelength. The AD300 comes preloaded with two gratings and slit tailored for highresolution work throughout the usable range of the detector. Either or both gratings may be user specified to achieve resolution and desired bandwidth window onto the array. The standard dual function entrance can accept light directly coupled through the built-in slit or from a standard fiber. The standard model comes with a 20µm slit for the highest resolution performance. In general, in order to maximize thruput, the grating should be selected to determine bandwidth needed and the largest possible slit should be selected that produces an acceptable resolution. For a full list of standard available gratings, please see the grating section in the A. Other gratings are available as special orders. 40

Grating groove/mm Specifications: Spectrograph center set wavelength (nm) CCD Camera (AD202) Spectral range: 200 to 1100nm tunable Number of pixels: 512 x 122 Pixel size: 24 by 24µm Well Depth (e - ): Unbinned: >300,000 Binned: >600,000 Read Noise (e - ): 10-15 (typical) Dark Count (e - /pixel/s): 4-5@ -20 C Dynamic Range: >86dB Digital Resolution: 16-bit (50kHz) Exposure Time: 0.03-10,400 sec. (0.010 sec. increments) Cooling: -20 C or software programmable to 45 C below ambient. Temperature Stability: ±0.1 C Operating Environment: Temperature: -30 to 80 F Relative humidity: 10 to 90% noncondensing PC Interface: Parallel port. 10' cable included. Software: KestralSpec (see section) Options: Remote trigger; remote shutter. Tunable Spectrograph Design: Czerny-Turner, dual grating turrets f#: 3.9 Focal length: 140mm Wavelength accuracy: 0.2nm Wavelength precision: 0.2nm Resolution (nm) for slits: Bandwidth (nm) 20µm 0.125mm 0.3mm 1200 250 68 0.2 1 2 500 63 0.2 < 1 2 1050 44 0.1 < 1 < 2 600 250 140 0.4 < 2 5 500 136 0.4 2 5 1050 125 0.3 2 5 300 250 283 0.8 4 10 500 280 0.8 4 10 1050 272 0.8 4 9 Grating efficiency curves of standard gratings. 1200 groove/mm blazed at 200nm and 500nm. Gratings: 1200 grooves /mm at 200nm and 1200 grooves /mm at 500nm standard Stray light rejection: better than 10-4 Total Weight: 10lbs. Computer Control: RS232 entrance: Dual SMA/20µm slits standard. Other slit or fiber connections available. Available slit sizes: 20µm standard. 50µm, 100µm, 0.125mm, 0.150mm, 0.3mm, 0.6mm, 1.2mm, and 2.4mm, available. System Requirements Pentium with 16Mb RAM (more recommended) Windows 98/ME/2000/XP USB Port (for software key) RS232 port Parallel port Ordering Information: Please indicate product number plus description when ordering. AD300 Back Thinned CCD Tunable Absolute Efficiency (%) 100 80 60 40 20 0 0.1 0.3 0.5 0.7 0.9 1.1 1.3 1.5 1.7 Wavelength (mm) 1.9 41

SM300 Modular Fluorescence / Raman High QE Back-thinned CCD High Dynamic Range Low Noise Versitile Modular Design Flexible Fiber Coupling Optional Dual or Triple Grating for High Resolution Operation The SM300 is an integrated CCD spectrometer system specifically designed for low light level fluorescence and Raman measurements. The system consists of the AD300 high performance wavelength tunable CCD spectrometer, the AST-XE tunable excitation light source, the AT-SHC4 cuvette sample chamber, and computer interface with Windows based operation software. The modular design allows the components to be decoupled and used individually, or in connection with a variety of sampling accessories for fluorescence, Raman, reflectance, transmittance, absorbance, and emission measurements. The versatility of the system is further enhanced by optic fiber coupling capability for unique applications. Tunable High Quantum Efficiency Back-thinned CCD The AD300 module uses a back-thinned area CCD array, which exhibits high quantum efficiency and low noise. The array is cooled for noise reduction and long-term stable operation. The CCD is coupled to a small CM based dual grating tunable spectrograph with computer control to both select grating and wavelength. Gratings and slit should be specified by user for optimum performance. The AD300 module may be substituted with one of our larger DK series triple grating spectrographs and cooled CCD camera. Grating Spectrograph center Resolution (nm) for slits: groove/mm set wavelength (nm) Bandwidth (nm) 20µm 0.125mm 0.3mm 1200 250 68 0.2 1 2 500 63 0.2 < 1 2 1050 44 0.1 < 1 < 2 600 250 140 0.4 < 2 5 500 136 0.4 2 5 1050 125 0.3 2 5 300 250 283 0.8 4 10 500 280 0.8 4 10 1050 272 0.8 4 9 Grating should be selected to give the desired bandwidth. The largest possible slit should be selected that produces an acceptable resolution. 42

Tunable Excit citation Source The AST-XE wavelength tunable light source consists Center Slit width = 0.125mm Slit width = 2.4mm of a xenon source coupled to Wavelength Bandpass (nm) Power (µw) Bandpass (nm) Power (mw) a CM110 computer controlled AST-XE-175EX (200-1100 nm) monochromator for high 200nm 0.9 0.2 17.3 0.9 excitation power output. Comes standard with two highresolution 500nm 0.8 2.9 15.6 10.0 gratings for good coverage 200-1100 nm and user changeable slit set. Ozone blocking Xenon source available. Four Port Sample Chamber The AT-SCH4 comes configured with broadband optics optimized for the right-angle measurement configuration. Specifications: AD300 CCD CCD Detector (AD202) Spectral Range: 200nm to 1100nm Array (pixels): 512x122 standard Pixel Size (µm): 24 Well Depth (e-): Unbinned >300,000 Binned >600,000 Read Noise (e-): 10-15 (typical) Dark Count (e-/pixel/sec): 4-5 @ -20 C Exposure Time: 0.03 seconds to 10,400 sec. (0.010 second increments). Cooling : -20 C or programmable down to 45 C below ambient temperature. Temperature Stability: ±0.1 C Software: KestralSpec (see section) PC Interface: Parallel port, 10' cable included. Operating Environment: Temperature -30 to 80 F. Relative humidity 10 to 90% noncondensing Sample Chamber AD300 CM110 21 Xenon source Dimensions of layout of SM300 Optical System Design: Czerny-Turner, dual grating turrets f#: #: 3.9 Focal length: 140mm Wavelength accuracy: 0.2 nm Wavelength precision: 0.2 nm Slit: 20µm, 50µm, 100µm, 0.125mm, 0.150mm, 0.3mm, 0.6mm, 1.2mm, and 2.4mm, please specify. Stray light rejection: better than 10-4 System Requirements Pentium with 16Mb RAM (more recommended) Windows 98/ME/2000/XP USB Port (for software key) Parallel port Two RS232 ports (one may be eliminated by use of the DK1200 CM Controller, see CM Series Options section) Ordering Information: Please indicate product number plus description when ordering. 17 SM300 SM300-DKSP SM300-DKSP-I Fluorescence/Raman SM300 with triple grating capability SM300-DKSP with imaging capability 43

SM301 PbS Array Low Noise Cooled, Stable Operation 256 Elements Accommodates spectral measurements in the 1 to 3 micron range. Optical input direct to slit or via fiber. The Choice for IR Spectral al s The SM301 is a versatile, high performance PbS array spectrometer. Its active components include a TE cooler and a 256-element PbS detector element array. Operation of the unit for research applications is easy with the included Windows based SM32Pro-based analysis software. The system is ideal for spectroscopic applications in the 1 to 3 micron region. Available system options include a built-in high-speed shutter and optical blank pixels for setting dark current offsets. The SM301 includes thermoelectric cooling to guarantee long-term operational stability. 44

General Description The SM301 is a complete compact PbS array for use with a PC to perform spectral measurements in the region of 1 to 3 microns. It consists of four parts: 1. an entrance mechanism with a built-in slit, a fiber coupling adapter, and an order sorting filter; 2. a spectrograph of a crossed Czerny- Turner arrangement using high quality optics; 3. a linear lead sulfite sensor array and driving circuitry; 4. a computer interface for data acquisition. All the optical components and driving electronics are enclosed in an aluminum housing for stable operation. A thermal electric (TE) cooler is also included. The SM301 employs a multiplexed PbS array as its NIR detection element. The array is cooled and temperature stabilized at -10 o C which ensures a long-term operation stability. A built-in mechanical shutter mechanism is controlled by the system clock and is synchronized with the array readout operation. Dark signal can thus be automatically measured by the built-in electronics periodically and subtracted automatically. Compared with conventional scanning NIR spectrometers the SM301 provides the multichannel detection advantage, both in reducing the measurement time and enhancing measurement signal-to-noise ratio. The SM301 can operate at a readout rate of 100 khz or faster allowing fast measurement and averaging operation to be performed in a short period of time. A variety of accessories makes the SM301 versatile for process control, spectroscopy, environmental monitoring, and other applications. It can easily be configured for transmission, reflectance, absorbance, and other measurements. The wavelength range from 1 to 3 µm can be covered by one grating optimized for the wavelength range. The spectral range can also be factory configured to meet application needs. The SM301 can accept light directly coupled through a built-in slit, from a fiber through an SMA coupler or both. The fiber coupling ability makes the unit flexible for remote and process control applications. Where high mobility is required, the SM301 can be used with just a slit to eliminate the light transfer variations caused by the changes in fiber bending curvatures. As a result, attenuation resulting from the use of optical fibers can also be avoided. Camera Mirror Entrance Slit Fiber Coupler Specifications: Grating SM301 Optical Path Number of pixels: 256 Pixel size: 45 by 450µm Peak responsivity: 1x10 6 V/watt Spectral response range: 1000 to 3000nm Spectral coverage: about 600nm in user specified region Spectral Resolution: 20nm with standard module and slit option. entrance: Slit: 50µm to 400µm Fiber: SMA 905 fiber coupler 50µm to 600µm core diameter NA = 0.2 Grating: 75 to 1200 grooves per mm Stray light rejection: better than 10-3 Analog to digital: 12-bit resolution, PCMCIA standard Dynamic range: >1000:1 for single scan Dimensions: 5 x 4 x 2.5 (LxWxH) Shutter: Built-in Detector cooling: -10 C Weight: 2 lbs. Software: SM32Pro Ordering Information: Please indicate product number plus description when ordering. SM301 PbS Array Collimating Mirror PbS Array Mirror 45

SM302 / SM302-EX InGaAs Array 0.9 to 1.7 µm or 0.9 to 2.6µm Extended Cooled Stable Operation Large Dynamic Range 16 bit Data Acquisition Low Noise Fiber Coupling Capability Compact, Tunable unable,, NIR The SM302 is a versatile, high performance, compact InGaAs array spectrometer that consists of a low noise, 256-element, InGaAs array detection module, a high precision tunable spectrograph optimized for the spectral range of 0.9 to 1.7µm (0.9 to 2.6µm extended), a 16-bit data acquisition board, and Windows based operating software. The dual grating capacity spectrometer comes preloaded with one grating and slit tailored for high-resolution work throughout the usable range of the detector. An optional second grating may be loaded to add wide coverage capability, or both gratings may be user specified to achieve desired coverage and resolution. Integrated filters allow the user to selectively block out unwanted higher orders, and the standard dual function entrance can accept light directly coupled through the built-in slit or from a standard NIR fiber. The SM302 detector is a multiplexed InGaAs array that is thermoelectrically cooled and temperature stabilized to ensure long-term operation stability. The multichannel detection with a readout rate of 333 khz or faster both reduces measurement time and enhances signal-to-noise ratio. revised 8/03 46

Detector Specifications Standard Extended Detector Hamamatsu InGaAs Array Range 0.9 to 1.7 µm 0.9 to 2.55 µm Number of pixels 256 Pixel size 50 by 250µm Bad Pixels 2% max 5% max Peak sensitivity 1.55µm 2.3µm Peak responsivity 0.95 A/W 1.1 A/W Dynamic range 10,000:1 8,000:1 Analog to digital 16-bit PCI interface, 333 khz Integration Time Min: 5ms Max: 10s Cooling -10 C one stage TE -20 C two stage TE Dark Current 0.1 pa typ. 1000 pa typ. Noise mv rms 0.15 0.18 Maximum non-uniformity ± 5% max ± 10% max Grating Bandwidth Resolution groove/mm Peak (nm) (nm) (nm) Status 600 1200 126 <1 INCLUDED SM302 1600 113 INCLUDED SM302-EX 1850 97 special order 2500 70 special order 300 1200 280 <2 special order 1700 270 special order 2000 260 STOCK 2500 250 STOCK 150 1250 580 4 STOCK 2000 570 special order 2500 560 special order 75 1700 1170 8 STOCK 2000 1170 special order 2500 1160 special order 45 1750 1970 13 STOCK Spectrograph: Resolution: <2nm with standard configuration entrance: Dual SMA/ 50µm slit standard. Other slit or fiber connections options available Available slit sizes: 50µm standard. 100µm, 0.125mm, 0.150mm, 0.3mm, 0.6mm, 1.2mm, and 2.4mm, available. f#: 3.9 Grating: One 600 groove grating included. Additional gratings available upon request Grating control: RS232 Filtering: Permanent 0.9 µm low blocking filter included. 1.3 µm low blocking flip-filter included in extended model. Dimensions: 10.5 x 5 x 4 (LxWxH) Weight: 6.5 lb. Software: Windows control program and LabVIEW. drivers included. Ordering Information: Please indicate product number plus description when ordering. SM302 SM302-EX InGaAs Array Extended range InGaAs Array 47

SM520 Extreme Resolution CCD Optical input direct to slit or via fiber. Allows higher resolution spectral measurements in up to a 700nm measurement window between 200nm and 1050nm double the resolution of the SM200 and SM240. USB 2.0 interface with 16-bit dynamic range available! The Choice for Spectral al s The SM520 is a CCD based spectrometer that offers more than double the resolution of the SM240. This resolution is achieved using oversized (30mm x 30mm) optical-bench components. These components offer approximately 4 times the effective collimation, grating and focusing area than what is used in the SM200 and SM240. As with all spectrometers, effective resolution increases as window size decreases. A 100nm window will have approximately.09nm resolution (as opposed to.3nm for the SM200 and SM240). A 700 nm window will have approximately.56nm resolution (as opposed to 1.12 nm for the SM200 and SM240). Standard interfaces include a USB 2.0 interface with 16-bit extended dynamic range and a PCI card interface with 12-bit dynamic range. Custom interfaces and legacy ISA and PCMCIA interfaces are also available. Software support includes a SDK and DLLs for dedicated applications development and our SM32Pro windows based spectral acquisition and analysis software. Both standard and legacy interface designs provide support for advanced acquisition programming and external triggering. 48

Software SM32Pro - Windows 98,2000, XP based software for data acquisition and analysis. Transmission, reflectance, and absorbance measurements. Data export, zoom in and out, spectrum overlays, and many more features. Color analysis tools included. Signal average and integration time control. Double beam version available. SDK and DLLs available for easy custom software development. Specifications: Detectors: Sony CCD Linear Array Number of Pixels: 2048 Sensing Pixel Size: 14µm x 200µm Sensitivity: 1800 V/(lx s) @ 660nm Customer array installation available Dimensions (inches): 7.0 h x 6.75 w x 3.0 d Weight: 4.0 lbs. Spectral Range: UV - 200nm to 450nm VIS - 380nm to 760nm NIR - 550nm to 1050nm other ranges are configurable from 200nm to 1050nm Spectral Resolution: ~0.1nm, dependent on spectral range, slit width, and fiber diameter. Entrance: Fiber SMA 905 or FC fiber coupler. 50-600µm core Ø fiber NA = 0.2 Slit 10, 25, 50 or 100µm Dynamic Range: 12 bit (4096:1) or 16 bit (65536:1) Computer Interface: USB 2.0 16 bit 500KHz PCI bus NI-PCI 12 bit 200 KHz PCI interface board Call SP for other interface options, including PCMCIA and ISA Temperature Range: 15 C to 40 C Software: SM32Pro Ordering Information: Please indicate product number plus description when ordering. SM520 USB SM520 PCI Software USB interface, PCI interface, 49

SpectraM AT200720 Filter for removing second orders for 200 to 720nm. AT3501050 Filter for removing second orders for 350 to 1050nm. AT-450 Reflectance attachment, built-in light source, 45 illuminating and 0 viewing geometry for SM200, 220, and 240. AT-COS Cosine Corrector for measurement of filtered off-angle light. The fused silica dome shaped diffuser gives excellent transmission in the visible region and adequate transmission in the UV region. AT-CRT CRT attachment for SM200 and 240. AT-DIF Diffuser mounts directly to the SM Series spectrometers. Offered with a ground quartz diffuser as standard, up to 3-0.5" Ø by 1.5mm thick ND filters can be added to the assembly. AT-IS-1.5 Stand alone or directly attachable Integrating sphere (1.5"sphere). AT-UVE UV enhancement coating for detector array. AT-IRE IR enhancement coating for detector array. SM2xx AT-DIF Adapter AT-DIF Diffuser AT-COS Cosine Corrector AT-COS NI-xxx SM500 100 KHz PCM(CIA), PCI or ISA data acquisition board with cable. Conversion box with cable for accepting NI- PCM(CIA), PCI and ISA computer interfaces. AT-IS-1.5 Integrating Sphere 50

SM32Pro Software Displays percent of reflectance. Calculates XYZ, Yxy, L*a*b*, L*C*hº, L*a*b*, L*C*h*, E Lab and E CMC Illuminant conditions A and D65. CIE 2º and 10º standard observers. View up to 6 reflectance traces on a single graph, with multiple graphs tiled on a single screen. Prints in color or black & white. Offers easy custom wavelength calibration function. Control signal averages and integration time Save color files, export color files, and print color matching files. Exports graph or data to other Windows software and to most DOS software. Has rubber-band zoom and auto-peak find. Features intuitive menu system and tool bars. Includes comprehensive documentation 16- and 32-bit Windows and DOS SDK software developer libraries are available. SpectraM 3.x General-purpose data acquisition and processing software for SM200, SM-210, SM-220 (b), and SM-240 units. SpectraM 3.x allows Reflectance,Transmission and Absorbance measurements. Additionally CIE color values such as X Y Z, and Lab, may be obtained-using A and D 65 illuminant conditions with the software package. Data may be saved as a graph, or exported to ASCII text files for import to spreadsheet applications for further analysis. Graphing functions include zooming, basic text annotation, and plot overlays on a single graph. Color values may be compared to a user selectable standard in order to obtain Delta values. calibration can be handled easily through use of the software combined with a traceable light source. SpectraM-XL Microsoft Excel macro supports SM 200, SM-210, SM-220 (b), and SM-240 for data acquisition, graphics, and data processing. SpectraM SDK, 16 Bit & 32 Bit Available for customers who wish to use SM hardware with custom designed software. The SDKs are available in 16-bit and 32-bit formats, and include our dynamic linked libraries in addition to several various code samples on how to use the functions the DLLs contain. A manual that details the functions available is also included. 51