CARESTREAM INDUSTREX Digital Imaging Plates

Similar documents
CARESTREAM INDUSTREX Digital Imaging Plates

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS

HPX1-Plus. For Non-Destructive Testing. THE BENCHMARK IN COMPUTED RADIOGRAPHY.

CR Basics and FAQ. Overview. Historical Perspective

Guide to Manual Processing of NDT Films

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY

INDUSTREX (installed and tested prior to shipping) Windows 7 Ultimate 64 bit Filter

HPX-PRO. For Non-Destructive Testing. THE ANSWER TO PORTABLE DIGITAL NDT.

HPX-PRO. For Non-Destructive Testing.

KODAK EKTASCAN IR Laser Imaging Film / 1356 / EIR

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

DACON INSPECTION SERVICES. Computed RADIOGRAPHY

Acquisition, Processing and Display

Examination of Pipe Welds by Image Plate Based Computed Radiography System

KODAK INDUSTREX AA400 Film Versatility is the key.

Diazo C Microfilm 1957, 2957, 3957 Diazo D Microfilm 1956, 2956, 3956

UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY

TECHNICAL DATA / COLOR PAPER July 2003 E-23

Experiences of users in Digital Radiography

Digital radiography: Practical advantages of Digital Radiography. Practical Advantages in image quality

KODAK EKTACHROME 64T Professional Film

INDUSTREX Film. For Non-Destructive Testing WHEN CLARITY IS CRITICAL

Spokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales

STUDENT REVIEW QUESTION SET K CR/DR CONTENT AREA

TECHNICAL DATA / COLOR PAPER July 2003 E-19

Autofluor. Autoradiographic Image Intensifier. Documented... Autofluor is Superior! C 3 PPO-DMSO. Autofluor

Gamex CR 2.0 Program description and operating manual

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

IMAGELINK Diazo Duplicating Microfilms

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

ISO INTERNATIONAL STANDARD

Computer Output Microfilm Data Sheet

RADIOGRAPHIC EXPOSURE

Amorphous Selenium Direct Radiography for Industrial Imaging

KODAK EKTACHROME RADIANCE III Paper

RA Duplicating Film X-OMAT 5000 RA Processor; RP X-OMAT Chemicals; 90 Second Cycle; Diffuse Visual Densitometry. Density

ScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Advancements In Digital Radiography: CR, DR, and DICONDE

9/10/2012. Computed Radiography Chapter 3 Physics and Technology. What is Computed Radiography?

COMPUTED RADIOGRAPHY (CR)

KODAK EKTACHROME 100 Plus Professional Film

EASTMAN PLUS-X Reversal Film / 7276

Computed Radiography of Resistance Temperature Sensor for Indian PHWR

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

Surprises with Light JoAnne Dombrowski

Light Enhancement Film

TECHNICAL DATA / COLOR REVERSAL FILM January 1998 E-154

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

Application Notes! RIGID MATERIALS. Rigid material standards. Printing on Rigid Materials with the Gerber Solara ion & Gerber CAT UV

THE CR SPECIALISTS HD-CR CR 35 NDT

This document is originally written in English. Guide Name: CS 7400 User Guide Part Number: 6K3919 Revision Number: 03 Print Date:

Modelling Computed Radiography Detectors with a Cascaded Linear System Model

ON THE WAY TO DIGITAL RADIOGRAPHY

KODAK Simulation Film / 7157

TECHNICAL DATA / COLOR NEGATIVE FILM February 1998 E-44

KODAK EKTACHROME 160T Professional Film / EPT

Digital Imaging Considerations Computed Radiography

3M Scotchgard Surface Protection Film 2200

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

KODAK PROFESSIONAL ELITE Chrome 200 Film

MINIMUM REQUIREMENTS FOR A DARKROOM.

Conversion to Digital Radiography from Film Radiography

KODAK PROFESSIONAL Display and Print Materials

Application of 3M Pressure Sensitive Films to 3M Panagraphics Substrates

KODAK EKTACHROME 64 Professional Film

THEIMER - lamps. The optimal type for every application. Ga - Fe doped: Multi spectrum type TH...2 Ga - Pb doped: Dual spectrum type THS...

Low V.O.C. 2-Component Polyurethane Game Line Paint System

Standard Guide for Computed Radiology (Photostimulable Luminescence (PSL) Method) 1

EASTMAN EXR 500T Film 5298

EASTMAN TRI-X Reversal Film 7278

Pilkington OptiView Protect. Pilkington OptiView. Handling and Processing Guidelines

TECHNICAL DATA / COLOR TRANSPARENCY FILM

KODAK PROFESSIONAL PRO IMAGE II Paper

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

DIGITAL RADIOGRAPHY ARTIFACTS

Welding Inspection Non-Destructive Testing Course Reference WIS 5

Radiographic Testing (RT) [10]

INTRODUCTION. Logos Digital Imaging System 1 User Manual v 4.1.5

GAFCHROMIC HD-810 Radiochromic Dosimetry Film Configuration, Specifications and Performance Data

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

EASTMAN EXR 200T Film 5287, 7287

Hardware for High Energy Applications 30 October 2009

KODAK VISION3 Color Digital Intermediate Film 5254 / 2254

Conversion, Application and Maintenance of the Avery Dennison Floor Marking System Instructional Bulletin #6.30

September 10, 2009 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

KODAK MIN-R S Film / 4906

KODAK EKTACHROME 64 Professional Film

10/26/2015. Study Harder

LECTURE 1 The Radiographic Image

KODAK Medical X-ray Film / General Purpose / Blue / 3528 / MXB

Contrast Enhancement Materials CEM 365HR

TECHNICAL ADVICE. CARE & MAINTENANCE Colour fading

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

KODAK VISION Expression 500T Color Negative Film / 5284, 7284

What is Paint?

OPTIMIZATION OF SCANNING PARAMETERS OF COMPUTED RADIOGRAPHY FOR CHARACTERIZATION OF EXPANDED POLYSTYRENE

Custom Pendant- Hardwire Assembly and Installation Instructions

Transcription:

TECHNICAL DATA / Non-Destructive Testing February 2011 TI-2632 CARESTREAM INDUSTREX Digital Imaging Plates CARESTREAM INDUSTREX Flex XL, GP and HR Digital Imaging Plates (IPs) are designed for computed radiography in non-destructive testing applications. These plates employ storage phosphors which capture and retain a latent image in direct proportion to an exposure of ionizing radiation. This latent image is subsequently read out by scanning with a red laser, which stimulates the emission of blue light, in a phenomenon known as photostimulated luminescence. The imaging plate can be loaded into a flexible or rigid cassette and used with metal screens of appropriate thickness. They offer the flexibility of film without the need for wet processing, so you can capture and read images quickly and easily, both in the field and in the lab. The images can be optimized, if needed, and can be stored and shared digitally. These imaging plates work with CARESTREAM CR Systems including the INDUSTREX HPX-1, ACR-2000 and ACR-2000i Digital Systems. CARESTREAM INDUSTREX Flex XL, GP and HR Digital Imaging Plates are: Flexible Wrap around most shapes. Sharp Better resolution than high-speed films, and a suitable replacement for many applications. Available in Multiple Sizes To cover a wide range of applications. Portable With a CARESTREAM INDUSTREX Digital System, image capture in remote areas is easier than ever. Versatile Use in a rigid or flexible cassette. Efficient Phosphor plates can be erased and reused thousands of times, require less exposure than film, and provide faster image access. Certified When used with CARESTREAM INDUSTREX HPX-1, ACR-2000 and ACR-2000i Digital Systems, all plates meet requirements for the highest system class according to EN 14784-1 and ASTM E 2446. Recommended Uses are available in many sizes, and are designed for a wide variety of NDT applications, including: Castings Erosion and corrosion Pipeline inspection Welded fabrication Ordnance Storage and Handling The lifetime of the plates is hundreds or thousands of exposure/readout/erase cycles, determined primarily by the care in handling and environmental conditions. Careless handling and very dirty environments can shorten the useful lifetime of an imaging plate. Inspect phosphor plates every week and replace when wear is evident. Clean every 200 exposures, every 30 days, or as necessary as directed in the cleaning sections of this document. Handling Handling the IP and operating the HPX-1 or the ACR-2000/ACR-2000i reader must be done in a darkened room that is free of light contamination. It is not necessary to have complete darkness, but the light source must be a low wattage incandescent bulb. Fluorescent, sodium vapor, mercury vapor, safelights and sunlight must not be allowed in the processing room during handling or scanning of the exposed imaging plates. Under normal use conditions, phosphor plates will eventually show wear. Plate wear can result in artifacts on radiographs. This may occur from abrasion of the protective overcoat or inadvertent physical damage to the surface or edge. Certain chemical agents, such as non-approved plate cleaners, hand lotions, topical medications, food, and so forth, may also damage the plates. Handle flexible phosphor plates with care. Hold plates by the edges and by the black side. Avoid contact with the plate s white (phosphor) side. Make sure hands are clean and dry. For best results, wear nitrile rubber or latex gloves. Carestream Health, Inc. 2011

Cutting Cutting the plates is not recommended, as this will compromise the edge seal and make the plates prone to moisture damage at the edges. Temperature Range The normal temperature operating range is -5 to 30 C (23to86 F), although lower temperatures for short periods (several hours) will have no detrimental effect on the performance or physical integrity of the plates. In very hot environments, care should be exercised in bending or flexing the plates, as the phosphor layer could crack if flexed at temperatures exceeding 65 C (149 F). Between 65 and 100 C (149 and 212 F), minor distortions of the polyester support may occur, and over 100 C (212 F), damage to the phosphor layer (blistering/ buckling) can occur. When radiography of very hot objects (such as hot welds) is necessary, a thin fire-resistant insulating layer may be placed between the cassette and the object, if experimentation shows it does not negatively affect image quality. Again, as a practical matter, the upper temperature limit will be determined by the point at which the cassette begins to burn or the lead identification letters begin to melt. Cleaning Plates employ a phosphor that is moisture sensitive. When exposed to water (either liquid or vapor form), the phosphor breaks down and liberates iodine. The iodine can become trapped within the phosphor layer at the interface between the overcoat and phosphor layer. The yellow-brown color in the iodine strongly absorbs the blue light emitted by the phosphor. This results in a loss in plate speed, which causes image quality problems. The plates are over-coated with a highly moisture-resistant polymer blend. However, the overcoat is very thin (less than 0.0254 mm [0.001 in.]) and has limited resistance to mechanical abrasion that may occur during cleaning. Thus, it is possible to lower the resistance to water during use or cleaning. This can result in the degradation of the plate. New imaging plates should be cleaned before first use. This will impart the necessary anti-static properties and prevent the attraction of dust and dirt which can result in image artifacts. Caution Read and follow instructions in Material Safety Data Sheets (MSDS) for KODAK Screen Cleaner. Note: Plates should be wiped routinely to remove any dust and loose dirt. It is also a good idea to clean the interior of flexible cassettes to avoid transfer of dirt or dust to the plate. Use KODAK Screen Cleaner to remove other dirt. Other cleaning solutions can contain chemicals that cause visible or hidden damage to the plate and could result in immediate or future image artifacts. Cleaning Methods For routine cleaning, place the plate with the black (non-phosphor) side down on a clean, dry, non-abrasive surface, such as the cassette s cleaned Tube Side. Wipe the plate gently to remove dust. For other dirt, use KODAK Screen Cleaner as follows: 1. Fold a non-abrasive, lint-free wipe or cloth and dampen with a small amount of the solution. Do not pour the solution directly onto the plate. Excessive amounts of the screen cleaner may damage the plate. Moisture can cause immediate or future screen damage and image artifacts. Minimize contact with moisture and always dry plates immediately. 2. Wipe the plate thoroughly, one section at a time. Fold the cloth to expose a fresh area for each section of the plate. 3. If necessary for the removal of persistent dirt, apply pressure while cleaning. 4. Thoroughly dry the plate with a clean and dry, non-abrasive, lint-free cloth to remove residual cleaner. Do not leave the plate to air dry. Never insert a storage phosphor plate into a cassette unless it is thoroughly dry. Water, isopropyl alcohol (Isopropanol, rubbing alcohol), and plate cleaners containing isopropyl alcohol are not recommended. 2 TI-2632

Characteristics Physical Properties Total Thickness Thickness Phosphor layer Overcoat Backing Layer XL 428 (16.9) 150 (5.9) 6 (0.24) 18 (0.71) HR 444 (17.5) 150 (5.9) 6 (0.24) 25.4 (1) GP 605 (23.8) 300 (11.8) 12 (0.47) 38.1 (1.5) are comprised of a layer of barium fluorobromoiodide doped with divalent Europium (BaFBr/I:Eu2+), coated on a 10-mil polyester support. A polymer overcoat provides protection against normal handling such as fingerprints and moisture. A black polycarbonate backing layer provides anti-halation protection and curl control, and also contains slip agents for optimum transport through the CR reader hardware. Flexibility The plates can be bent around pipes and other curved surfaces down to a radius of one inch, although as a practical matter, the bend radius will be much more limited by the configuration of the cassette and the lead screens, when used. Signal Retention The stored energy in the imaging plate phosphors will decay over time, resulting in some signal loss. This effect is known as image fading. This loss is also a function of temperature, and will be greater at elevated temperatures. In most applications this signal decay will be of little importance, given the very wide latitude of storage phosphor imaging plates. In critical applications, there are a couple of measures that can be taken; when the interval between exposing and readout is more than a couple of hours, the plates can be exposed with a higher radiation dose (greater milliamp-seconds) to compensate for signal decay. For shorter intervals, simply keeping the time between exposing and readout constant will eliminate any decay-induced variability. The figure below shows the percent signal retention in the first two hours at ambient temperatures after an exposure of 80 kv. Signal Retention Sharpness Sharpness is typically characterized by Modulation Transfer Function, a measure of signal or image modulation as a function of spatial frequency. The figure below shows the MTF curves for all imaging plates, and highlights the improved sharpness of the HR and XL plates. Modulation Transfer Function 100 Sharpness (MTF %) 90 80 70 60 50 40 30 20 10 XL Blue HR & XL GP 0 0 1 2 3 4 5 6 Spacial Frequency (cycles/mm) H192_3008AA TI-2632 3

Absorption Imaging plates are quite sensitive to low energy scatter, as shown by their x-ray energy absorption curves below. For this reason, the use of lead screens, especially at energies greater than 100 kv, is important in controlling scatter to produce optimum image quality. The thickness of the screens is determined by experimentation, however it will generally be two to three times the thickness of a comparable film application. Disposal Due to the presence of barium, this plate may be considered a hazardous or special waste at the end of its useful life. For disposal or recycling information, please contact local authorities. To locate the Article Information Sheet (AIS) for each plate, go to www.carestream.com and navigate to Support and Education > Environment Health & Safety. Absorption X-ray Absorption vs. X-ray Energy Relative (Photon) Absorption 1 0.1 GP XL & XL Blue 0.01 0 50 100 150 X-ray Energy (kv) H192_3010AA Emission The wavelength of light needed to stimulate phosphor luminescence is different from the wavelength of light released by the phosphors. This enables the stimulating light to be filtered from the phosphor luminescence. The emission is typically stimulated with a red laser diode, while the photostimulated emission of the XL, GP and HR imaging plates is a narrow band of blue light near 400 nm. Emission GP, HR, XL & XL Blue Emission Relative Emission 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 300 350 400 450 500 550 600 650 700 750 800 Wavelength (nm) H192_3011AA 4 TI-2632

NOTICE: While the sensitometric data in this publication are typical of production coatings, they do not represent standards which must be met by Carestream Health, Inc. Varying storage, exposure, and processing conditions will affect results. The company reserves the right to change and improve product characteristics at any time. INDUSTREX is a trademark of Carestream Health, Inc. The Kodak trademark and trade dress are used under license from Kodak. Pub No. TI-2632 Revised 2011-02-16 (February 16, 2011) Printed in the U.S. Carestream Health, Inc. 150 Verona Street Rochester, NY 14608