Smart-UPS On-Line Isolation and Step-Down Transformer SRT5KTF

Similar documents
User Manual. Smart-UPS On-Line. Uninterruptible Power Supply. Isolation Transformer Models: SURT001 and SURT002

Smart-UPS RT. Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004.

Broadband Step-Up Transformer. User Manual

AccuSine SWP A. Technical Specifications. Active Harmonic Filter 02/

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

MODEL 3810/2 Line Impedance Stabilization Network

OWNER S MANUAL DANGER

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

RFTX-1 Installation Manual

OWNER S MANUAL DANGER

Using the USB Output Port to Charge a Device

C-Bus 8 Channel Low Voltage Relay

NetShelter VX. Four-Post Open Frame. User s Manual

A-16D A-Net Distributor

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Glass Electrode Meter

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

Grid Radar Installation Manual

Classic Series Public Address Amplifiers C10 & C20 Models

A Channel Amplifier

automatic embosser & die cutter USER MANUAL

HTA125A/250A. Power Amplifiers. Installation & Use Manual

Instruction Sheet SNE SERIES. Cable Chase

User s Guide FM Transmitter

High Performance Microphone Splitter. Artcessories. User's Manual

Model 113 Scintillation Preamplifier Operating and Service Manual

Technical Support, End User License & Warranty Information

MaxLite LED Self-Driven LiteBars

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

LTX-5520 Electrical / Optical Converter Operating Instructions

Line 6 L I M I T E D R E F URBISH E D (B-ST O C K) W A RR ANT Y

Classic Series Public Address Amplifiers C10 & C20 Models

Model 9305 Fast Preamplifier Operating and Service Manual

INSTALLATION GUIDE ET1551U. IP Video Camera Over Single Twisted Wire Ethernet Extender with EtherStretch. Description

XPR522 XPR540. XPR SERIES INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Comfort 10S Wall Hardwire Installation and Operations Manual

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

Important Safety Information

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

PDB4. Four Channel Passive Direct Box USER'S GUIDE

INSTRUCTION MANUAL MODEL SAS RS-7 LASER DISTANCE METER

14 CHANNEL FAMILY RADIO SYSTEM MODEL # FR142

LD8000 Series LD8025 LD8050 LD8100

Gypsy Statement of Limited Warranty. Part 1 General Terms

Model CC4041. CC Series Amplifier. Installation and Use Manual

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Warranty Terms & Conditions

S5-ADU. Front... 4 Rear... 4

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

ACT-IR220Li/220LN IrDA Serial Port Adapter

Operating Instructions

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

COMMERCIAL TRANSMITTER INSTRUCTIONS

ADA416-XLR DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

Radio Remote Controls Manual K Series

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

ACT-IR220L/LE IrDA Serial Port Adapter

Wireless Transceiver (TRV)

HDTV Antenna. Contemporary Indoor. User s Guide

Owner s Manual MRX-10 Advanced Network System Controller

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

MICRO SERIES MONITORS

XPA2100 XPA4100 XPA6100. XPA SERIES INSTALLATION/OWNER S MANUAL Mobile Power Amplifiers

COOPER POWER SERIES. External application of a motor start capacitor on a single-phase voltage regulator. Voltage Regulators MN225063EN

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

AV30MX-2 Operation Manual

Model 9302 Amplifier-Discriminator Operating and Service Manual

NS-HDTUNE HD Radio Tuner

Single Flex and Double Flex Couplings (i)

XIA3145 INSTALLATION/OWNER S MANUAL 2/1-Channel Mobile Power Amplifier

DIGITAL AUDIO AMPLIFIER WITH BLUETOOTH. Model: DAA User Manual

CANARY AUDIO. EL34 Stereo Power Amplifier. Handcrafted in California CA-770 OWNER S MANUAL MADE IN USA

Series NRX with PXR - Instructions for Neutral Current Sensor Type NF

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

ELECTROSURGICAL UNIT ANALYZER

MaxLite Linear Strip ECO Series

Preliminary Data Sheet!

Installation/User Manual

Acu-Park TM. user s guide Directed Electronics, Inc. Vista, CA N9100T 09-04

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

SIR-WRR1. User's Guide SIRIUS Echo Antenna. Signal Repeater System Accessory

DL102 Counter Loop Amplifier

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

Radio Remote(s) (Installation Manual)

2015 RIGOL TECHNOLOGIES, INC.

Oberebenestrasse Bremgarten Switzerland Tel Fax

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

IS7705. Installation & Operation Manual AUDIO INTEGRATION KIT. TranzIt LINK

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

Xpress Satellite Radio Receiver

Document Version 1.2

DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

TIA-952 Optical/Electrical Converter. Operating Instructions

CR31. Companion. Instruction Manual

INSTALLATION MANUAL SONANCE SOUNDBARS SB46 M AND SB46 L. Introduction. Box Contents. Wall Mount Installations

NEO CAR AUDIO. Neo AUXiN AUX INPUT INTERFACE. Instruction Manual

Transcription:

Smart-UPS On-Line Isolation and Step-Down Transformer SRT5KTF Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate, service or maintain the transformer. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of this symbol to a Danger or Warning product safety label indicates that an electrical hazard exists that will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Safety Information NOTICE NOTICE is used to address practices not related to physical injury. Adhere to all national and local electrical codes. All wiring must be performed by a qualified electrician. Changes and modifications to this unit not expressly approved by APC could void the warranty. This transformer is intended for indoor use only. Do not operate this transformer in direct sunlight, in contact with fluids, or where there is excessive dust or humidity. Be sure the air vents on the transformer are not blocked. Allow adequate space for proper ventilation. For a transformer with a factory installed power cord, connect the transformer power cable directly to an output receptacle of the UPS. Do not use surge protectors or extension cords. The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment. For rack mount transformers, always install the transformer directly above the UPS in rack-mount configurations. The UPS must be installed below the transformer. Always install peripheral equipment above the UPS in rack-mount configurations. Additional safety information can be found in the Safety Guide supplied with this unit.

Electrical safety Hardwire safety For models with a hardwired input, the connection to the branch circuit (mains) must be performed by a qualified electrician. 230 V models only: In order to maintain compliance with the EMC directive for products sold in Europe, output cords attached to the transformer must not exceed 10 meters in length. The protective earth conductor for the transformer carries the leakage current from the load devices (computer equipment). An insulated ground conductor is to be installed as part of the branch circuit that supplies the transformer. The conductor must have the same size and insulation material as the grounded and ungrounded branch circuit supply conductors. The conductor will typically be green and with or without a yellow stripe. The UPS input ground conductor must be properly bonded to protective earth at the service panel. If the UPS input power is supplied by a separately derived system, the ground conductor must be properly bonded at the supply transformer or motor generator set. Verify that all branch circuit (mains) and low voltage (control) circuits are deenergized, and locked out before installing cables or making connections, whether in the junction box or to the transformer. Wiring by a qualified electrician is required. Check national and local codes before wiring. All openings that allow access to transformer hardwire terminals must be covered. Failure to do so may result in personal injury or equipment damage. Select wire size and connectors according to national and local codes. General information The model and serial numbers are located on a small, rear panel label. Recycle the package materials or save them for reuse. FCC Class A radio frequency warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are intended to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Product Information The Smart-UPS SRT transformer is intended for use as a step-down transformer. This transformer can also function as an isolation transformer. The transformer can be installed in a standard 19-inch rack. The transformer can be installed as a tower or in a rack. For rack-mount configuration use only the APC by Schneider Electric rack model SRTRK2. 2 Isolation and Step-Down Transformer SRT5KTF

Package Contents Inspect the contents upon receipt. Notify the carrier and dealer if the unit is damaged. Use with all models Front bezel Use with SRT5K/6K/8K/10K UPS 1 tie bracket to secure the UPS to the transformer 1 tie bracket to secure the UPS to the transformer Use with SRT3000XLT UPS Top and bottom tie brackets to secure the UPS with transformer 2 screws to secure tie bracket 1 pan head screw to secure tie bracket 2 tie brackets to secure the UPS to the transformer 2 pan head screws to secure tie brackets Specifications For additional specifications refer to the APC by Schneider Electric web site, www.apc.com. Environmental Temperature Maximum Elevation Humidity Protection Class Operating 0º to 40º C (32º to 104º F) Storage -15º to 45º C (5º to 113º F) Operating 0-3,000 m (0-10,000 ft) Storage 0-15,000 m (50,000 ft) 0% to 95% relative humidity, non condensing IP 20 rating Physical Lifting guidelines 32-55 kg (70-120lb) > 55 kg (> 120lb) Unit weight, without packaging 56.82 kg (125 lb) Unit weight, with packaging 63.64 kg (140 lb) Unit dimensions without packaging 432 mm x 130 mm x 660 mm Height x Width x Depth 17 in x 5 in x 26 in Unit dimensions with packaging 347 mm x 603 mm x 980 mm Height x Width x Depth 13.68 in x 23.74 in x 38.6 in The model and serial numbers are on a small label located on the rear panel. Isolation and Step-Down Transformer SRT5KTF 3

Electrical Nominal Input Voltage (Vac) Input Voltage Range (Vac) Input Service Maximum Current (Amps) Input Connection Line Frequency (Hz) Nominal Output Voltage (Vac) Output Receptacles Maximum Output Power (VA) Maximum Output Power (Watt) 208 V, 220 V, 240 V 170 V - 280 V 30 A 3 ft cord with L6-30P 50/60 Hz 220 V / 240 V / 208 V / 110 V / 120 V (2) L6-20R (1) L6-30R (1) L14-30R (8) 5-20R (accepts both 5-20P and 5-15P) 4800 VA 4800 W Wiring Diagram CAUTION DAMAGE TO EQUIPMENT OR PERSONNEL Adhere to all national and local electrical codes. Wiring should be performed by a qualified electrician. Failure to follow these instructions can result in equipment damage and minor or moderate injury suo1007a Utility Power UPS P D U 3 ft cable L6-30 plug Transformer P D U Power to Load Equipment Typical system configuration Utility voltage UPS output Input voltage selection Transformer output voltage switch position 208 V 208 V 208 V 240 V / 208 V / 120 V 240 V 240 V 240 V 240 V / 208 V / 120 V 220 V 220 V 240 V 220 V / 110 V 4 Isolation and Step-Down Transformer SRT5KTF

Tower Installation DAMAGE TO EQUIPMENT OR PERSONNEL CAUTION The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment. Always use the recommended number of screws to secure brackets to the UPS and transformer. Always install the transformer to the left of the UPS when facing the front of the units. Always install the optional bypass panel to the left of the transformer when facing the front of the units. Failure to follow these instructions can result in equipment damage and minor or moderate injury Note: The transformer must be installed to the left of the UPS when facing the front of the units. If the configuration includes the optional bypass panel, ensure that the bypass panel is installed to the left of the transformer when facing the front of the units. Refer to the bypass panel manual for installation instructions. Tower transformer Your UPS model may differ in appearance from those depicted in these graphics. The installation process is identical for the following models: SRT5KXLT SRT6KXLT SRT8KXLT SRT10KXLT Place the transformer to the left side of the UPS at the installation location. suo1001a suo1000a Isolation and Step-Down Transformer SRT5KTF 5

Remove two screws at the top and bottom of the UPS. Remove two screws at the top and bottom of the transformer. suo1002b Reuse the screws removed in and to secure tie brackets at the top and bottom of the transformer and UPS. su0051b Install the tie brackets to the transformer and UPS. suo1006c suo1003a 6 Isolation and Step-Down Transformer SRT5KTF

Install the front bezel on the transformer. Tower transformer SRT3000XLT model Place the transformer to the left side of the UPS at the installation location. suo1001a suo1000a suo1004a Isolation and Step-Down Transformer SRT5KTF 7

Remove two screws at the top and bottom of the UPS. Remove two screws at the top and bottom of the transformer. suo1105a su0051b Reuse one screw removed in and one new pan head screw to secure the tie brackets at the top and bottom of the transformer and UPS. Note: Mount the pan head screws to the UPS. suo1101b Install the tie brackets to the transformer and UPS. Install the front bezel on the transformer. suo1003c suo1004b 8 Isolation and Step-Down Transformer SRT5KTF

Connection and Startup Instructions DAMAGE TO EQUIPMENT OR PERSONNEL CAUTION Disconnect the mains input circuit breaker before installing or servicing the UPS or transformer or connected equipment. Disconnect internal and external batteries before installing or servicing the UPS or connected equipment. The UPS contains internal and external batteries that may present a shock hazard even when disconnected from the mains. UPS AC hardwired and pluggable outlets may be energized by remote or automatic control at any time. Disconnect equipment from the UPS before servicing any equipment. Do not use the UPS as a safety disconnect. Failure to follow these instructions can result in equipment damage and minor or moderate injury 1. Ensure that the transformer input cord is unplugged. 2. Remove the voltage selection switch cover. 3. Set the input voltage selection switch to match the utility voltage of 208 or 240 VAC. Typical system configuration on page 4. 4. If 240 V utility is used, program the UPS output for 240 V. See the UPS user manual. 5. Install the voltage selection switch cover. 6. Plug applicable load equipment into the PDU receptacles on the transformer. 7. Plug the transformer input cord 1 into the appropriate PDU receptacle on the rear of the UPS. 8. Ensure that the output circuit breakers are ON. 9. Ensure that the input circuit breaker is ON. suo1005a Isolation and Step-Down Transformer SRT5KTF 9

Tower to Rack-Mount Conversion DAMAGE TO EQUIPMENT OR PERSONNEL CAUTION The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment. Always use the recommended number of screws to secure brackets to the UPS and transformer. Always install the transformer above the UPS in the rack. Always install the optional bypass panel above the transformer in the rack. Failure to follow these instructions can result in equipment damage and minor or moderate injury Note: The transformer must be installed directly above the UPS in the rack. If the configuration includes the optional bypass panel, ensure that the bypass panel is installed above the transformer in the rack. Refer to the bypass panel manual for installation instructions. Service 1. Install the transformer directly above the UPS in the rack. Refer to the Smart-UPS RT Tower to Rack-mount Conversion Guide and the optional rail kit. 2. See the Connection and Startup Instructions on page 9 to complete the installation. If the transformer requires service do not return it to the dealer. Instead, follow these steps: 1. Contact APC by Schneider Electric Customer Service through the APC by Schneider Electric web site, www.apc.com/support. a. Note the model number of the transformer, the serial number, and the date purchased. If you call APC by Schneider Electric Customer Service, a technician will ask you to describe the problem and try to solve it over the phone, if possible. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#). b. If the transformer is under warranty, repairs are free. If not, there is a repair charge. 2. Pack the transformer in its original packaging. If the original packing is not available, refer to the APC by Schneider Electric web site, www.apc.com/support, for information about obtaining a new set. a. Pack the transformer properly to avoid damage in transit. Never use Styrofoam beads for packaging. Damage sustained in transit is not covered under warranty. 3. Mark the RMA# on the outside of the package. 4. Return the transformer by insured, prepaid carrier to the address given to you by Customer Service. 10 Isolation and Step-Down Transformer SRT5KTF

Limited Warranty Schneider Electric IT Corporation (SEIT), warrants its products to be free from defects in materials and workmanship for a period of two (2) years from the date of purchase. The SEIT obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. Repair or replacement of a defective product or parts thereof does not extend the original warranty period. This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase. Products may be registered online at warranty.apc.com. SEIT shall not be liable under the warranty if its testing and examination disclose that the alleged defect in the product does not exist or was caused by end user or any third person misuse, negligence, improper installation, testing, operation or use of the product contrary to SEIT recommendations or specifications. Further, SEIT shall not be liable for defects resulting from: 1) unauthorized attempts to repair or modify the product, 2) incorrect or inadequate electrical voltage or connection, 3) inappropriate on site operation conditions, 4) Acts of God, 5) exposure to the elements, or 6) theft. In no event shall SEIT have any liability under this warranty for any product where the serial number has been altered, defaced, or removed. EXCEPT AS SET FORTH ABOVE, THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, APPLICABLE TO PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION HEREWITH. SEIT DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE. SEIT EXPRESS WARRANTIES WILL NOT BE ENLARGED, DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, SEIT RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION WITH THE PRODUCTS. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE CONSTITUTE SEIT SOLE LIABILITY AND PURCHASER EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES. SEIT WARRANTIES EXTEND ONLY TO ORIGINAL PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES. IN NO EVENT SHALL SEIT, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER SEIT HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES. SPECIFICALLY, SEIT IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROFITS OR REVENUE, WHETHER DIRECT OR INDIRECT, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS OF DATA, COSTS OF SUBSTITUANTS, CLAIMS BY THIRD PARTIES, OR OTHERWISE. NOTHING IN THIS LIMITED WARRANTY SHALL SEEK TO EXCLUDE OR LIMIT SEIT LIABILITY FOR DEATH OR PERSONAL INJURY RESULTING FROM ITS NEGLIGENCE OR ITS FRAUDULENT MISREPRESENTATION OF TO THE EXTENT THAT IT CANNOT BE EXCLUDED OR LIMITED BY APPLICABLE LAW. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support. Customers with warranty claims issues may access the SEIT worldwide customer support network through the APC Web site: www.apc.com. Select your country from the country selection drop down menu. Open the Support tab at the top of the web page to obtain information for customer support in your region. Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. Isolation and Step-Down Transformer SRT5KTF 11

APC by Schneider Electric Worldwide Customer Support Customer support for this or any other APC by Schneider Electric product is available at no charge in any of the following ways: Visit the APC by Schneider Electric web site, www.apc.com to access documents in the APC Knowledge Base and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC by Schneider Electric web site for specific countries, each of which provides customer support information. www.apc.com/support/ Global support searching APC Knowledge Base and using e-support. Contact the APC by Schneider Electric Customer Support Center by telephone or e-mail. Local, country specific centers: go to www.apc.com/support/contact for contact information. For information on how to obtain local customer support, contact the APC by Schneider Electric representative or other distributor from whom you purchased your APC by Schneider Electric product. 2016 APC by Schneider Electric. APC, the APC logo, Smart-UPS and PowerChute are owned by Schneider Electric Industries S.A.S. or their affiliated companies. All other trademarks are property of their respective owners. EN 990-5431C 8/2016