COMPREHENSIVE TG-142 IMAGING AND MACHINE QA

Similar documents
Nathan Childress, Ph.D., DABR

Emerging Technology: Real-Time Monitoring of Treatment Delivery EPID Exit Dose QA

PHYSICS QUESTIONNAIRE FORM

7/23/2014. Acknowledgements. Implementing a new digital medical accelerator. New Generation of Medical Accelerators

An Introduction to TG-142 Imaging QA Using Standard Imaging Products. Mark Wiesmeyer, PhD, DABR Technical Product Manager Standard Imaging, Inc.

The Current State of EPID-Based Linear Accelerator Quality Assurance. Disclosures. Purpose of this First Talk 8/3/2017

A positioning QA procedure for 2D/2D (kv/mv) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup

QUALITY CONTROL PHANTOMS FOR RADIOTHERAPY AND MEDICAL IMAGING

ISPFILMQATM STATE-OF-THE-ART RADIOTHERAPY VERIFICATION SOFTWARE. Supports all major radiotherapy technologies! FilmQA TM

8/3/2017. Use of EPIDs for Non-Routine Linac QA. Disclosure. Learning Objectives. Parts of this project received support from Varian Medical System.

QUALITY CONTROL SOFTWARE FOR RADIOTHERAPY AND MEDICAL IMAGING

CHAPTER 2 COMMISSIONING OF KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIOTHERAPY

Version 4.4. User Manual

DOSELAB TOMOTHERAPY TG-148 QA QUICK GUIDE TG-148 RECOMMENDED TESTS 1. V.B.1.C. - Y-JAW DIVERGENCE/BEAM CENTERING

ISO Cube Daily QA Package

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications

Version 4.5. User Manual

Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience

Mobius3D. Software based IMRT QA

ArcCHECK. The Ultimate 4D QA Solution. Your Most Valuable QA and Dosimetry Tools

IQM Detector Characteristics: Signal reproducibility

Isocenter and Field of View Accuracy Measurement Software for Linear Accelerator

ArcCHECKTM. The Ultimate 4D QA Solution. Your Most Valuable QA and Dosimetry Tools. VMAT RapidArc TomoTherapy Pinnacle 3 SmartArc Conventional IMRT

LINEAR ACCELERATOR. Buyer's Guide. Version 1.1

8/3/2016. The EPID Strikes Back. Novel Applications for Current EPID Technology. Joerg Rottmann, PhD. Disclosures and acknowledgements

Quality Assurance Results for a Commercial Radiosurgery System: A Communication

A Beam-Level Delivery Accuracy Study of the Robotic Image Guided Radiosurgery System Using a Scintillator/CCD Phantom

SRS MapCHECK. SRS Patient QA, No Film. Your Most Valuable QA and Dosimetry Tools

Comparative performance evaluation of a new a-si EPID that exceeds quad high-definition resolution

Sub-mm accuracy of accelerators: How manufacturers achieve it, how physicists verify it

3D Diode Array Commissioning: Building Confidence in 3D QA Technology

Performance evaluation of the RITG148 + set of TomoTherapy quality assurance tools using RTQA 2 radiochromic film

Initial setup and subsequent temporal position monitoring using implanted RF transponders

IMRT Delivery System QA. IMRT Dose Delivery. Acceptance testing. Why: specific tests for IMRT? Accuracy of leaf positioning (gaps) MLC Alignment

SRS MapCHECK. SRS Patient QA, No Film. Your Most Valuable QA and Dosimetry Tools

X3D in Radiation Therapy Procedure Planning. Felix G. Hamza-Lup, Ph.D. Computer Science Armstrong Atlantic State University Savannah, Georgia USA

Introduction. Use of EPIDs for Routine Linac QA 8/3/2017. Disclosure. Our research group receives funding from Varian Medical Systems

QC Testing for Computed Tomography (CT) Scanner

Sensitivity study of an automated system for daily patient QA using EPID exit dose images

TECHNICAL NOTE. The following information is provided as a service to our users and customers:

The Ultimate 4D QA Solution A 4D isotropic cylindrical detector array for arc delivery QA and Dosimetry.

CHAPTER 6 QUALITY ASSURANCE OF VARIAN ON-BOARD IMAGER

SUN NUCLEAR. EPIDose : An Overview of EPIDose and the EPIDose Process and Algorithm. corporation. Your Most Valuable QA and Dosimetry Tools

A diagnostic tool for basic daily quality assurance of a tomotherapy Hi Art machine

imagespectrum ADVANCED DIGITAL IMAGE MANAGEMENT SYSTEM Get a Better Handle on the Big Picture

Installation und Kommissionierung des Viewray MRIdian Linac Hamburg, 28. Mai 2018 Sebastian Klüter

Volumetric Modulated Arc Therapy. David Shepard Swedish Cancer Institute Seattle, WA

Phantoms in Medical Physics (RT) U. Oelfke. Division of Radiotherapy & Imaging

A proposed method for linear accelerator photon beam steering using EPID

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

ArcCHECK, ein neuartiger QS-Ansatz bei der Rotationsbestrahlung

A Generalized Strategy for 3D Dose Verification of IMRT/VMAT Using EPID-measured Transit Images

TOMOTHERAPY H SERIES TomoH, TomoHD and TomoHDA Systems Technical Specifications

TOMOHD. Product Specifications

Slide 1. Slide 2. Slide 3 ACR CT Accreditation. Multi-Slice CT Artifacts and Quality Control. What are the rules or recommendations for CT QC?

C a t p h a n. T h e P h a n t o m L a b o r a t o r y. Ordering Information

T h e P h a n t o m L a b o r a t o r y

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA

Evaluation of a diode array for QA measurements on a helical tomotherapy unit

New spectral benefi ts, proven low dose

A new approach to measure dwell position inaccuracy in HDR ring applicators quantification and corrective QA

Impact of energy variation on Cone Ratio, PDD10, TMR20 10 and IMRT doses for flattening filter free (FFF) beam of TomoTherapy Hi-Art TM machines

Gantry angle determination during arc IMRT: evaluation of a simple EPID-based technique and two commercial inclinometers

The most Comprehensive, Reliable, Economical and Easy to use GAFCHROMIC film based RT QA system Updated Feb 08 BUSINESS UNIT OF ISP

The Right Choice Any Day, Any Time. Product Solutions for LINAC QA. Overview

KODAK Dental Imaging Software. Quick Start Guide

Department of Physics, State University of New York at Buffalo, Buffalo NY, USA

Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy

Image Quality. HTC Grid High Transmission Cellular Grid provides higher contrast images

A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer *

Image Display and Perception

Automated dose control in multi-slice CT. Nicholas Keat Formerly ImPACT, St George's Hospital, London

Commissioning an Elekta Versa HD linear accelerator

Web based 3D Planning Tool for Radiation Therapy Treatment

Development of a Virtual Simulation Environment for Radiation Treatment Planning

Laser Systems for Patient Alignment

GE Healthcare. Senographe 2000D Full-field digital mammography system

MOVING LASER SYSTEMS IN RT

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

7/24/2014. Image Quality for the Radiation Oncology Physicist: Review of the Fundamentals and Implementation. Disclosures. Outline

DETECTORS UNCOMPROMISING QUALITY. The standard in dosimetry measurements for over 40 years. EXRADIN DETECTORS

Multi-Access Biplane Lab

Image Quality. HTC Grid High Transmission Cellular Grid provides higher contrast images

Investigation of the mechanical performance of Siemens linacs components during arc: gantry, MLC, and electronic portal imaging device

Commissioning. Basic machine performance MLC Dose rate control Gantry speed control End-to-end tests

specifications TrueBeam System

Monica Kishore. Medical Physics Graduate Program Duke University. Approved: Jennifer O Daniel, Co-Supervisor. Fang-Fang Yin, Co-Supervisor

Robert Pagnanelli BSRT(R)(N), CNMT, NCT, FASNC Chief Technologist, Nuclear Imaging Duke University Medical Center. Thursday September 8, 2011

Computed Tomography. The Fundamentals of... THE FUNDAMENTALS OF... Jason H. Launders, MSc. Current Technology

Quality control of Gamma Camera. By Dr/ Ibrahim Elsayed Saad 242 NMT

Table 1: Available X-ray Beam Energy Combinations (MV) 6 10/ Yes Yes 6 16/15 6 Yes No 6 23/18 6 Yes No 6 25/20 6 Yes No

SUBCHAPTER 14. THERAPEUTIC INSTALLATIONS

ORTHOPANTOMOGRAPH OP 2D Quality and design

Features and Weaknesses of Phantoms for CR/DR System Testing

A device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors

Intraoral X-Ray For Film and Digital Systems

Distributed source x-ray tube technology for tomosynthesis imaging

Comparison of peripheral dose measurements using Ionization chamber and MOSFET detector

Accuracy of SRS dose delivery using the TomoTherapy Hi-Art System

University of Wollongong. Research Online

Transcription:

QA SOFTWARE COMPREHENSIVE TG-142 IMAGING AND MACHINE QA Automate the analysis of over thirty TG-142 recommended QA tasks

The rapid progress of Radiation Therapy has created the need for Quality Assurance testing far greater in scope and effort than in the past. Sophisticated intensity-modulated radiation treatments rely on near-perfect multileaf collimator operation, while advanced imaging technologies for Image-Guided Radiation Therapy rely not only on image quality, but the spatial coincidence of treatment and imaging frames of reference. TG-142 recommends a suite of daily, monthly, and annual tests to meet the challenge of modern clinical radiation therapy Quality Assurance. In addition to defining the tests for recently-developed technologies, TG-142 identifies the need to test against established baselines and track and trend results. All of these new QA obligations, necessary for a safe and effective clinic, increase physicists work load and further strain busy schedules. PIPSpro efficiently consolidates TG-142 QA workload by incorporating over 30 procedures into one easy-to-use platform. When used in conjunction with specialized phantoms from Standard Imaging, PIPSpro becomes an indispensable part of your QA process, giving you confidence that your clinic is operating within specifications. PIPSpro software and phantoms are valuable tools for streamlining over 30 of the TG-142 tests, automating data analysis, and providing documentation of the test results. By providing quantifiable and repeatable results, PIPSpro makes it easier for our center to become compliant with TG-142. Rick Baker Physics Applications Specialist Iowa Health Des Moines - John Stoddard Cancer Center

PIPSpro TG-142 Coverage table ii Monthly Mechanical Light/radiation field coincidence Jaw position indicators Cross-hair centering table iii Annual Mechanical Collimator rotation isocenter Gantry rotation isocenter Couch rotation isocenter Coincidence of radiation and mechanical isocenter table v Multileaf Collimation Weekly Qualitative test, aka picket fence Monthly Setting vs radiation field for two patterns Travel speed Leaf position accuracy Annual MLC transmission Leaf position repeatability MLC spoke shot Coincidence of light field and x-ray field table vi Imaging Daily Planar kv and MV (EPID) imaging Positioning/repositioning Imaging and treatment coordinate coincidence Cone-beam CT (kv and MV) Imaging and treatment coordinate coincidence Positioning/repositioning Monthly Planar MV imaging (EPID) Imaging and treatment coordinate coincidence Scaling Spatial resolution Contrast Uniformity and noise Planar kv imaging Imaging and treatment coordinate coincidence Scaling Spatial resolution Contrast Uniformity and noise Cone-beam CT (kv and MV) Geometric distortion Spatial resolution Contrast HU constancy Uniformity and noise Segmental IMRT Moving window IMRT Film images can be used in all modules with the exception of Imager QA and Stereotactic, where image quality and positioning are critical variables that cannot be maintained using film. DICOM images are supported in all modules. Raw images are supported for ExacTrac and Cyberknife kv planar imager QA.

TG-142 Made Easy Designed with a convenient and optimized workflow in mind Why thousands of users in over 700 clinics choose PIPSpro as their TG-142 software: Simple, clean and consistent user interface Easy-to-read reports, charts, and graphs PDF and comma separated variable (CSV) results export Multiple open modules for streamlined workflow Physicist-controlled editor for creating testing baselines Tracking and trending for test results Quick Selects for organizing tests and accessing test results Automatic image compositing for EPID MLC QA and StarShot images Centralized database for easy configuration and accessibility to results Complete Elekta IMRT and VMAT logfile analysis Workflow automation - single click deployment results Faster QA with Quick Selects In Imager QA, Quick Selects are customizable collections of parameters that allow a variety of machine, imager, phantom, and energy combinations to be saved. Using Quick Selects, one-click activation provides an easy means to recall tests and track your results. Quick Selects are used in the Imager QA and the Logfile- Based MLC QA modules and, because of their power, will be used throughout PIPSpro. Now includes Stereotactic collimator rotation The TG-58 Report encourages users to demand the use of a tool such as PIPSpro QC Software at acceptance to help ensure that the EPID is indeed operating at or above specifications.* * Michael G. Herman, et al, Clinical Use of Electronic Portal Imaging: Report of AAPM Radiation Therapy Committee Task Group 58, Med. Phys. 28 (5), May 2001 Over 30 TG-142 procedures

Powerful Imager QA Consolidated TG-142 QA for volumetric and planar imaging CT Imaging QA Using cone beam or diagnostic images obtained with any of the Catphan phantoms (503, 504, 600), PIPSpro automatically finds analysis image slices and performs required TG-142 tests (geometric distortion, spatial resolution, contrast, HU constancy, uniformity and noise). Results are colored green ( Pass ), amber ( Alert ), or red ( Fail ) for easy viewing of status (this scheme is used throughout PIPSpro). Planar Imaging QA PIPSpro kv planar imaging QA uses images obtained with Standard Imaging s QC-kV1 phantom or Leeds Test Objects TOR CDR phantom. Testing is supported for kv imagers integrated with linear accelerators as well as images from ExacTrac, Cyberknife, and C-Arms. EPID MV planar imaging QA uses Standard Imaging s calibrated QC-3 phantom. Automatic Region Identification Is Key By automatically identifying analysis regions, subjectivity is reduced and results consistency is improved. Baseline Editor Individual baselines can be created for each combination of linear accelerator, imager, phantom, and energy that you test using Quick Selects. This unique and powerful feature allows you to choose representative measurements, combine them, and set alert and warning tolerances for your imaging systems. Phantom Stands and Holders Phantom stands and holders are available to accommodate CyberKnife and ExacTrac QA. Quantify the quality of your imagers

Complete MLC QA Cover all TG-142 MLC QA tests with EPID images and logfiles Matched Segments, aka Picket Fence Setting vs radiation field for two patterns (non-imrt) Travel speed leaf speed loss (IMRT)* Leaf position accuracy (IMRT) Average of leaf and interleaf transmission, all energies Leaf position repeatability* MLC spoke shot Coincidence of light field and x-ray field, all energies Segmental IMRT (step and shoot) test Moving window IMRT (four cardinal gantry angles) Image-Based Logfile-Based * With logfile-based analysis, PIPSpro is the only commercial software solution able to measure quantitative leaf speed loss and leaf position repeatability. Adapted from TG-142, TABLE V. Multileaf collimation PIPSpro MLC QA gives you actionable, quantitative results that allow you to track and trend all TG-142 requirements, delivering critical information that may indicate an impending MLC failure or indicate the need to recalibrate your machine for the best possible clinical outcomes. Step & Shoot and VMAT parameters are tested in any direction using MLC leaf pattern files (*.mlc, *.dva). PIPSpro is the first commercial machine QA software to determine leaf speed loss. Systems that report only maximum and mean leaf speed cannot be used to calculate leaf speed loss, as required by TG-142, notes Standard Imaging medical physicist Shannon Holmes, Ph.D. PIPSpro features automatic compositing of EPID MLC images, so you don t need to use third-party products to combine individual images. COMPLEX SIMPLE In simple leaf speed tests, all leaves travel together In complex leaf speed tests, every other leaf moves, maximizing inter-leaf friction Filmless MLC QA in a single platform

PIPSpro is able to measure quantitative leaf speed loss, not just deliver a qualitative result. Leaf speed status in a repeatability test True leaf speed QA

Comprehensive Machine and IGRT QA Track and trend results for classic TG-142 tests Radiation Light Field Analysis PIPSpro uses a single image taken with custom phantoms (FC-2, Center Marker) to calculate: Radiation and light field coincidence Radiation and crosshair displacement Light field and crosshair displacement Jaw position measurements Light field rotation Works for light fields defined by jaws or MLCs. Starshot Analysis PIPSpro s StarShot module uses EPID MV or film images to measure rotational deviations in gantry, collimator, and couch mechanical isocenters. Results are expressed as the minimum diameter containing all spokes at the central point of intersection. Unlike competing software, PIPSpro features automatic compositing of individual EPID spoke images, so you don t need to use third-party products to combine images. Works for spoke images defined by jaws or MLCs. Daily IGRT QA Tracking When using Image-Guided Radiation Therapy (IGRT) in the clinic, daily testing is recommended to verify that your imaging coordinate system is precisely aligned with your treatment coordinate system. TG-142 recommends two tests: Imaging and treatment coordinate coincidence and Positioning/ repositioning. Use the Standard Imaging MIMI (Multi-Image Modality Isocentricity) phantom with image registration software to calculate known 3D (x, y, z) and 6D (add couch pitch, yaw and roll) offsets. PIPSpro allows you to record your daily offsets and track and trend your results. Simple IGRT trending

Precise Stereotactic 3D Analysis Quick, easy, precise, and actionable Use Standard Imaging s Winston-Lutz phantom to measure the difference between the radiation isocenter and the mechanical isocenter for a linear accelerator. A number of images are taken with your portal imager using fixed angles or angles of your choice. Automatically load and analyze any images, including DICOM images, for cones or MLC s. Automatically get 2D radiation/mechanical offsets for each image. Automatically get an optimal 3D offset to correct patient offset errors. 3D analysis with x, y, z results that help you improve patient positioning. 3D offset isocenter accuracy within 0.1 mm

Centralized Database Management Simplify your QA by keeping all your data centralized and secure SITE 1 CENTRALIZED SITE 2 SITE 3 LOCAL 1 SITE PIPSpro can use a local or centralized database server. As a result, PIPSpro is the choice of small, large and multi-location treatment centers across the world. PIPSpro has the feel of a desktop application using a centralized server, but gives you the power to organize your sites into divisions and departments assigning users permissions to the departments and tasks that they need to do their work. Features include: Single access point controls division, department, linac, and user configuration Centralized data access point allows enterprise-wide access to data, results, and trending Unparalleled data security Citrix server support on enterprise wide systems DICOM router offers convenient access and routing of files by constantly listening for new images and automatically sorting them by file type and date into a directory of the users choosing Thorough service, knowledgeable support

Phantoms QC-3 Phantom calibrated phantom ref 71350 Used to test the image quality from electronic portal imaging devices (EPIDs). Winston Lutz Pointer Phantom PIPSpro recognizes most ball marker phantoms ref 72285 Expedite and simplify verification of sub-millimeter isocenter treatment setup. RECOMMENDED QCkV-1 Phantom calibrated phantom ref 71451 Ideal for kv imaging systems, including Varian, Elekta, BrainLAB and Cyberknife. FC-2 Phantom ref 72187 For performing the radiation field vs. light field test and jaw position testing Light Field Cross Hair Marker ref 72247 For performing the radiation field vs. light field test and jaw position testing ADDED VALUE Winston Lutz Cube Phantom PIPSpro recognizes most ball marker phantoms ref 91345 Expedite and simplify verification of sub-millimeter isocenter treatment setup. MIMI Phantom (Multiple Imaging Modality Isocentricity Phantom) ref 91240 Ensure image guidance accuracy by measuring the coincidence of isocenter prescribed by the lasers, treatment beam and image guidance systems. Catphan purchased through your linac vendor Compatible with model 503, 504, and 600 phantoms MLC QA Phantom ref 72277 For analyzing individual leaf positions of multi-leaf collimators (MLC) Leeds Test Objects purchased through your linac vendor Routine test objects designed to be used quickly and easily on a regular basis Phantom holders available for CyberKnife and ExacTrac imagers make PIPSpro a complete QA software for all imaging delivery systems PIPSPRO SOFTWARE SPECIFICATIONS OPERATING SYSTEM PROCESSOR MEMORY HARD DRIVE WINDOWS 7 (SP1) or better WINDOWS 8.1 (SP1) or better.net 4.0 or better Intel or AMD 350 MHz or greater 1 GB (3 GB recommended) 512 MB free space for software installation. Sufficient space to store image data files. 3GB or greater if installing SQL Server Express on the install host. CD ROM DRIVE 2X speed or greater VIRTUAL MACHINES Must support WMI (Windows Management Instrumentation) Citrix XenDesktop and Citrix XenApp DATABASE MANAGEMENT SQL Server 2008 R2 (or SQL Server Express equivalent) minimum PRODUCT STANDARDS Designed to meet IEC 60601-1-4 SCREEN 1152 864 XGA+(4:3) 1600 900 (16:9) or higher 16 bit HiColor or greater RECOMMENDED SOFTWARE Microsoft Excel Catphan is a registered trademark of The Phantom Laboratory. Windows is a registered trademark of Microsoft Corporation. Specifications subject to change without notice. To learn more call (800) 261-4446 or (608) 831-0025

www.standardimaging.com 800-261-4446. ph 608-831-0025. fax 608-831-2202 3120 Deming Way Middleton WI 53562-1461 USA 2016 Standard Imaging, Inc. 1251-29 (8.16)