Controlled Islanding Followed by Load Shedding Based on Rate of Frequency Decline

Similar documents
POWER systems are being operated closer to the stability

VOLTAGE STABILITY OF THE NORDIC TEST SYSTEM

A New Approach Applied to Adaptive Centralized Load Shedding Scheme

Integration of Variable Renewable Energy

Stability Issues of Smart Grid Transmission Line Switching

Real-time Decentralized Voltage Stability Monitoring and Protection against Voltage Collapse

IJSER. Fig-1: Interconnection diagram in the vicinity of the RajWest power plant

Use of the Power System Outlook (PSO) and SMART 1 Programs to View PSLF Dynamic Simulation Data Files

LARGE-SCALE WIND POWER INTEGRATION, VOLTAGE STABILITY LIMITS AND MODAL ANALYSIS

Online Wide-Area Voltage Stability Monitoring and Control: RT-VSMAC Tool

Security Enhancement through Direct Non-Disruptive Load Control

PMU-based protection for grid operation applications Wide Area Monitoring platform and controlled islanding

ESB National Grid Transmission Planning Criteria

Hydro-Québec s Defense Plan: Present and Future

ANALYTICAL AND SIMULATION RESULTS

Smart Grid Where We Are Today?

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

Controlled Islanding Strategy Considering Power System Restoration Constraints

Operational Modeling and Model Inputs

Keywords: Stability, Power transfer, Flexible a.c. transmission system (FACTS), Unified power flow controller (UPFC). IJSER

EE 742 Chapter 9: Frequency Stability and Control. Fall 2011

EH2741 Communication and Control in Electric Power Systems Lecture 2

Stability Improvement for Central China System

Task Force on Synchrophasor Protection Applications NASPI Engineering Analysis Task Team Matthew Rhodes 3/22/16

System Protection Schemes in Power Network based on New Principles

ITC Holdings Planning Criteria Below 100 kv. Category: Planning. Eff. Date/Rev. # 12/09/

Energy-Based Damping Evaluation for Exciter Control in Power Systems

Modle 6 : Preventive, Emergency and Restorative Control. Lecture 29 : Emergency Control : An example. Objectives. A simple 2 machine example

Power Plant and Transmission System Protection Coordination of-field (40) and Out-of. of-step Protection (78)

S.A.Soman. Power Swing Detection, Blocking and Out of Step Relaying. Department of Electrical Engineering IIT Bombay. Power System Protection

Texas Reliability Entity Event Analysis. Event: May 8, 2011 Loss of Multiple Elements Category 1a Event

System Protection and Control Subcommittee

Transmission System Phase Backup Protection

Reliability Guideline: Generating Unit Operations During Complete Loss of Communications

1544 IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 26, NO. 3, AUGUST 2011

Facilitating Bulk Wind Power Integration Using LCC HVDC

Slow Coherency Based Controlled Islanding in Large Power Systems

Combination of Adaptive and Intelligent Load Shedding Techniques for Distribution Network

A Real-Time Platform for Teaching Power System Control Design

DESIGNING POWER SYSTEM STABILIZER FOR MULTIMACHINE POWER SYSTEM USING NEURO-FUZZY ALGORITHM

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

Low Frequency Local mode Oscillations in NER Grid, Validation using Model based analysis and Mitigation

Keeping it up to Speed Off-Nominal Frequency Operations. CETAC 2018 San Ramon

Study on the Improvement of the Special Protection Scheme (SPS) in the Korean power system

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Practical PMU Applications for Utilities

A Comprehensive Approach for Sub-Synchronous Resonance Screening Analysis Using Frequency scanning Technique

Real Time Stability Analysis at Peak Reliability. Slaven Kincic, Hongming Zhang JSIS May 2017, SLC

MOST POWER system faults occur on high- and extrahigh-voltage

ELEMENTS OF FACTS CONTROLLERS

A Review of Adaptive Under Frequency Load Shedding Scheme on Islanded Distribution System Using MATLAB/SIMULINK

Post-Event Analysis of a Compound Event in the ERCOT System Using Synchrophasor Data

Reliability Considerations for PPMV. Ryan Quint, NERC Dmitry Kosterev, BPA NASPI-NERC PPMV Tools Workshop October 2016

Application Example Document ID: SA Rev. - September 24, 2004

Using Synchrophasors for Controlled Islanding A Prospective Application in the Uruguayan Power System

NVESTIGATIONS OF RECENT BLACK-

Introduce system protection relays like underfrequency relays, rate of change of frequency relays, reverse - power flow

Wide-Area Small-Signal Stability Controller

ECE 692 Advanced Topics on Power System Stability 5 - Voltage Stability

An Investigation of Controlled System Separation Following Transient Instability

ISSUES OF SYSTEM AND CONTROL INTERACTIONS IN ELECTRIC POWER SYSTEMS

Oscillatory Stability: Extended Range & Enhanced Source Location

Power System Stability. Course Notes PART-1

Endorsed Assignments from ERS Framework

Generator Parameter Validation (GPV)

A Real-Time Regulator, Turbine and Alternator Test Bench for Ensuring Generators Under Test Contribute to Whole System Stability

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

GRID RELIABILITY MONITORING

SYNCHROPHASOR TECHNOLOGY GLOSSARY Revision Date: April 24, 2011

Performance of Relaying During Wide-area Stressed Conditions

NERC Protection Coordination Webinar Series June 23, Phil Tatro

Real-time Monitoring of Power Oscillations and Modal Damping in the European ENTSO-E System

Control of Over-voltages on Hydro-Québec 735-kV Series-Compensated System During a Major Electro-mechanical Transient Disturbance.

PV CURVE APPROACH FOR VOLTAGE STABILITY ANALYSIS

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

Eigenvalue Analysis All Information on Power System Oscillation Behavior Rapidly Analyzed

Considerations and Recommendations for the Harmonisation of Under Frequency Loadshedding Schemes in Multi Zone Meshed Grids

Tor Rolv Time, Øystein Kirkeluten STATNETT Oslo, Norway

A Topology-based Scheme for Adaptive Underfrequency Load Shedding

Power System Protection Where Are We Today?

SCIENCE & TECHNOLOGY

Advantages and Disadvantages of EHV Automatic Reclosing

Under-Frequency Load Shedding based on PMU Estimates of Frequency and ROCOF

POWER SYSTEM OSCILLATIONS

Generator Protection GENERATOR CONTROL AND PROTECTION

The Role of Effective Parameters in Automatic Load-Shedding Regarding Deficit of Active Power in a Power System

Level 6 Graduate Diploma in Engineering Electrical Energy Systems

TRADITIONALLY, if the power system enters the emergency

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

Central Hudson Gas & Electric Corporation. Transmission Planning Guidelines

Lessons Learned in Model Validation for NERC Compliance

International Journal of Advance Engineering and Research Development

HISTORY: How we got to where we are. March 2015 Roy Boyer 1

NERC Protection Coordination Webinar Series June 30, Dr. Murty V.V.S. Yalla

Decision Tree Based Online Voltage Security Assessment Using PMU Measurements

Authors and affiliations. Introduction. Approach

Using Synchrophasors for Frequency Response Analysis in the Western Interconnection. Bonneville Power Administration -- WECC JSIS Chair

Table of Contents Error! Bookmark not defined.

Phasor-based wide area monitoring in the South African power system

Fault Ride Through Principles. and. Grid Code Proposed Changes

Transcription:

Controlled Islanding Followed by Load Shedding Based on Rate of Frequency Decline Internet Seminar October 1, 2002 Vijay Vittal Students: Haibo You, Zhong Yang 2002 Iowa State University

EPRI/DoD Initiative Our vision is to create a wide-area intelligent, adaptive protection and control system that empowers the future power grids by providing critical and extensive information in real-time, assessing system vulnerability quickly, and performing timely self-healing and adaptive reconfiguration actions based on system-wide considerations. We refer to the system as Strategic Power Infrastructure Defense(SPID) system. 2

3

4 Task description Self-healing strategy in competitive environment Task 4-34 3 Development of decentralized solutions with accurate modeling of interactions between hierarchies Transient angle instability emergency Transient voltage instability emergency Small disturbance voltage instability emergency Small disturbance oscillatory instability emergency Long term frequency instability emergency

When a power system is subjected to large disturbances and the vulnerability analysis indicates that the system is approaching a catastrophic failure, control actions need to be taken to limit the extent of the disturbance. In our approach, the system is separated into smaller islands at a slightly reduced capacity. The basis for forming the islands is to minimize the load-generation imbalance in each island, thereby facilitating the restoration process. 5 Basis for Self-Healing

6 Task thrust We propose: Controlled islanding followed by load shedding based on rate of frequency decline. Three thrust points: Where to island? Slow coherency based islanding. A c++ program is developed to identify the tripping sets. When to island? Corrective controls based on local measurement plus wide area phasor measurement A three-layer islanding architecture is proposed Load shedding scheme? A two-level load shedding scheme based on frequency and rate of frequency decline is designed

Slow coherency Singular Perturbation Method. A theory for decomposing dynamical systems with large eigenvalue difference. A method analyzing two-time-scale phenomena by introducing small perturbation parameters. Electromechanical Model & δ = Ω( ω 1) i 2H & ω = D ( ω 1) + ( P i X&& = i i 1 2 i ΩH i 1 KX = mi AX P ei & δi = Ω ωi ) 2Hi & ωi = Di ωi A grouping algorithm Research has been done to modify the algorithm to consider the load dynamics, second order system and detailed model. n j= 1 k ij δ j 7

8 Islanding Strategy (Where to Island) Coherency assumptions. The coherent groups are independent of the size of the disturbance; Linearized model can be used. The coherent groups are independent of the amount of the detail in the generating unit models; Classical model can be used. Slow coherency features Preserve the coherency assumptions. Properly states the oscillation feature of the large scale power system: the fast oscillations within a group and the slow oscillations between the groups. Identifies the weakest connection by grouping the generators with a certain number of slow modes. Grouping is not sensitive to the changes of the initial condition. Nonlinear applicability proved by nonlinear simulations.

9 Weak Connection Characteristics Slow coherency solves the problem of identifying theoretically the weakest connection in a complex power system network. The weak connection form best states the reason for islanding based on slow coherency. It is important when the disturbance happens to separate in the transient time scale the fast dynamics, which could propagate the disturbance very quickly, through islanding on the weak connections. In the transient time scale, the slow dynamics will mostly remain constant or change slowly on the tie lines between the areas. Once fast dynamics are detected on the tie lines, it means fast dynamics are being propagated through these weak connections. In order to prevent these we cut the ties to form islands identified by slow coherency.

Determination criteria for Island boundary Minimum generation load imbalance in each island. Reduces the amount of load shedding after the islands are formed. Ease of restoration. Each island is capable of matching the generation and load within prescribed frequency limit. Physical limits exists between two control areas. Restoration considerations. Each island has the black start capability that is sufficient for critical equipment.(does it contain a large capacity hydro machine?) Each island has proper voltage control capability to maintain a suitable voltage profile. Each island is capable of being monitored by the control center for security and coordination. Synchronizing devices are available near the boundary of the islands for re-closing the circuit and restoration function. 10

11 Automatic Program to Determine Islands Having determined the generators that form groups by the slow coherency approach, we now need to determine the boundary buses to form the islands that will contain these groups and also meet the islanding criteria. We use an adjacent link data structure to save the network information. Then through a series of reduction processes, the program forms a small network and performs an exhaustive search on it to get all the possible cut sets.

12 Islanding Strategy (When to Island) Three layers identified in the tripping mechanism. BPA s R-Rdot out of step relay. High change rate of the apparent impedance on the tie line is detected in the case simulation. Remote tripping is needed for the implementation of the controlled islanding. Response based R-Rdot out of step relay with decision tree support. Phasor measurement units can be used in control center for higher level switching action.

13 Switching Illustration of R-Rdot Out of Step Relay

14 Wide Area Measurement Illustration Central Point L: Load Shedding P: Phasor Measurement T: Tripping Line G: Generation Rejection L P P T T G P P Area1 Area2

15 Under-frequency Load Shedding Scheme based on Subsumption Model Information System Angle and Frequency difference Rate of frequency decline Frequency decline Islanding of Regions that Are out of Synchronism Inhibition signal Load-shedding scheme activated by rate of frequency decline Inhibition signal Inhibition signal Load-shedding scheme activated by frequency decline

The Reduced Model of Reheat Unit for Frequency Disturbance 57 Hz is selected to be the lowest operable system average frequency considering coordination with the governor-turbine system; coordination with the plant auxiliary system; coordination with the existing operation criteria. Using this reduced model and normalizing, we obtain that the lowest system average frequency for this disturbance is 57 Hz when P d= 0.3P sys. So we choose 0.3P sys as the threshold value of P d for the new load shedding scheme. 16

17 Rate of Frequency Decline Criteria M 0 Pstep = 60 = d ω 2 H M for disturbance P at each bus can be measuredat the the disturbance. P H is the systeminertia, which can be computed as follows: Hi S H = Stotal H :Inertia of S i Bi 0 step is the average rate of is the size of Bi step disturbance generator in system : Machine MVA Base systemfrequency declination. M, the rate of i S total frequency declination beginning of = Total generation

Frequency Threshold, Step Size and Time Delay The thresholds should be chosen not be too close to the normal frequency; but should be more effective to shed load earlier. Step size should be increasing in the schemes based on frequency decline; but should be decreasing in our scheme based on rate of frequency decline in order to arrest the frequency decline. Frequency steps must be far enough apart to avoid overlap of shedding due to time delay. The number of steps does not have very great impact on the effect of load shedding Generally, the threshold of the last step of load shedding is chosen no less than 58.3 Hz. Delay time for the first step is usually long to avoid unexpected actions due to small frequency oscillations; but it is set 0 cycles in our scheme to prevent sharp frequency declines. 18

19 Under-frequency Load Shedding Scheme NPCC Criteria, NPCC Guide are considered for Frequency Emergency. 59.5Hz 59.3Hz 58.8Hz 58.6Hz 58.3Hz Load Shedding Activated By rate of frequency decline 20(0c) 5(8c) 4(18c) 4(21c) Load Shedding Activated By Frequency decline 10(28c) 15(18c) *Note : c represents delay in cycles.

20 Simulation Cases Simulated cases include: One case of WSCC 29-machine system islanding by experience. Two cases WSCC 29-machine system islanding by slow coherency. WSCC System condition: Buses Gens No. Loads No. (CI, CMVA) Lines Trans Generations (MW,MVAR) Loads (MW,MVAR) 179 29 104 (67,24) 203 60 61410,12325 60785,15351 Northern part Southern part Gens Model Governor Model PSS Model Exciter Model Gen rich Load rich Detailed Not Available (Added) Available Available

21 Case1-Two Islands for 179-Bus System Based on Experience

22 Case2-Three Islands for 179-Bus System Based on Slow Coherency

23 Scenario Description Cases At 0.0 seconds At 0.2 seconds 1 REMOVE LINE ; MALIN 500;MALIN3 500;1/ MALIN 500;MALIN5 500;1/ MALIN 500;MALIN7 500;1/ REMOVE LINE ; ELDORADO 500;NAVAJO 500;1/ ELDORADO 500;MOENKOP4 500;1/ PALOVRDE 500;DEVERS 500;1/ PALOVRDE 500;DEVERS 500;2/ 2 REMOVE LINE ; MALIN 500;MALIN3 500;1/ MALIN 500;MALIN5 500;1/ MALIN 500;MALIN7 500;1/ REMOVE LINE ; TEVATR2 500;MIDWAY 500;1/ TEVATR3 500;GATES 500;1/ FOURCOR2 500;MOENKOPI 500;1/

24 Resistance Plot with Fault on TEVATR2 500;MIDWAY 500 TEVATR3 500;GATES 500

Simulation Result Case No.1 Frequency response of Generator 118 after the contingency of the 179-Bus system. Curve 1: Without self-healing. Curve 2: Islanding with no load shedding. Curve 3: Islanding followed by load shedding based on frequency difference. Curve 4: Islanding followed by load shedding based on the rate of frequency decline. 25

Simulation Result Case No.2 Frequency response of Generator 118 after the contingency of the 179-Bus system. Curve 1: Without self-healing. Curve 2: Islanding with no load shedding. Curve 3: Islanding followed by load shedding based on frequency difference. Curve 4: Islanding followed by load shedding based on the rate of frequency decline. 26

27 Results Comparison Cases Generation Load Imbalance (MW) Load Shed with Conventional Scheme (MW) Load Shed with New Scheme (MW) No. 1 Generation 16,265 Load 22,679 6,937 (11.4% 30.6%) 5,698 (9.4% 25.1%) No. 2 Central Island: Generation 5,118 Load 7,006 South Island: Generation 15,477 Load 17,373 1,810/0 (3.0%/0% 25.8%/0%) 1,450/0 (2.4%/0% 20.7%/0%)

28 Grouping Changed as the Load Change Load Change Percentage <-30% -30% to -17% (except at - 25%) -16% to 0% 1% to 6% (except at 1% and 5%) >6% System Condition Unstable Obtain Same Grouping Obtain Same Grouping Obtain Same Grouping Unstable

29

30

31 Future work In-depth research on the slow coherency theory and enhancement of the adaptive feature. Designing the restoration procedure to complete self-healing. Application of the algorithm on a large system scale. Definition and design of the vulnerability index taking into account relay modeling and measurements (New project with TAMU and WASU) Examine issues related to self-healing for voltage stability. Incorporation of the islanding agent and load shedding agent into multi-agent architecture and implementation on a large scale system (New CERTS Project)