CoServ Electric s RF Mesh Advanced Metering Infrastructure. RF/EMF Investigation

Similar documents
Regulatory Authority of Bermuda report on

Human Exposure Requirements for R&TTE and FCC Approval

WHITEPAPER WHITEPAPER

RF EMISSIONS FROM SMART GRID ELECTRIC METERS, HAN DEVICES, AND THEIR RELATIONSHIP TO THE FCC MAXIMUM PERMISSIBLE EXPOSURE LIMIT (MPE)

R ICHARD T ELL A SSOCIATES, INC.

RADIOFREQUENCY ELECTROMAGNETIC FIELDS

2200 Noll Drive Lancaster, PA Latitude: N 40º (NAD 83) Longitude: W 76º (NAD 83) 362 AMSL

Radio Frequency Emissions Analysis Report Sprint Wireless Water Tank Facility

Calculated Radio Frequency Emissions Report. Cotuit Relo MA 414 Main Street, Cotuit, MA 02635

RF EMISSIONS COMPLIANCE REPORT. Verizon Wireless. Report Status: Verizon Wireless is Compliant

Wireless Facility Radio Frequency Exposure Compliance Review

SAFETYTRAINING INFORMATION Your TYT ELECTRONICS CO.,LTD radio generates RF electromagnetic energy during transmit mode. This radio is designed for and

RF Exposure Assessment Report (FCC ID: 2AD8UAZRBRH1)

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA

Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report

Wireless Transmissions:

Health Issues. Introduction. Ionizing vs. Non-Ionizing Radiation. Health Issues 18.1

ELECTROMAGNETIC ENERGY (EME) EXPOSURE REPORT

January 31, Please contact me or Rebecca Giles if you have any questions concerning SDG&E s comments.

RADIO FREQUENCY NIER REPORT

Model: M /800 MHz Mobile Radio

ELECTROMAGNETIC ENERGY (EME) EXPOSURE REPORT

Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report

MAXIMUM PERMISSIBLE EXPOSURE STUDY

WIFI and Your Health

Royal Street Communications, LLC Proposed Base Station (Site No. LA0366A) 315 4th Avenue Venice, California

RF EXPOSURE REPORT. For. Model: SVI Trade Name: BOSCH

Order Number : GETEC-C FCC Part 1 Test Report Number : GETEC-E Page 2 / 15 CONTENTS

SAR REPORT. TEST STANDARDS: FCC Part 15 Subpart C Intentional Radiator. ARRIS Model Spectrum 110A Set Top Box With Bluetooth (DSS) and RF4CE (DTS)

Characterization of Radiofrequency Emissions From Two Models of Wireless Smart Meters

Verizon Wireless Site ID Lime Site Name Lime Site Compliance Report

Safety Code 6 (SC6) Measurement Procedures (Uncontrolled Environment)

RF Exposure Evaluation Report

Verizon Wireless Proposed Base Station (Site No South Goleta ) 4500 Hollister Avenue Santa Barbara, California

AT&T Mobility Proposed Base Station (Site No. CN4779A) 1101 Keaveny Court Walnut Creek, California

Assessment of Radiofrequency Microwave Radiation Emissions from Smart Meters. Sage Associates Santa Barbara, CA USA

Radio Frequency Electromagnetic Energy (RF-EME) Compliance Report

DEPARTMENT OF ECONOMIC DEVELOPMENT, JOBS, TRANSPORT AND RESOURCES QUANTIFYING SMART METER RF EME LEVELS IN VICTORIAN HOMES

Verizon Wireless Proposed Base Station (Site No Lake Cachuma ) 2680 Highway 154 Santa Barbara County, California

Report On. RF Exposure Assessment of the Sepura plc SRG3900 with AQHB Antenna. FCC ID: XX6SRG3900UW Industry Canada ID: 8739A-SRG3900UW

Verizon Wireless Proposed Base Station (Site No Berkeley Bekins ) 2721 Shattuck Avenue Berkeley, California

Wireless System Collocation Presents New Issues For Worker Protection

Q1. What is PG&E doing to inform the public of the "SIX INCH RULE" for people with pacemakers?

Radiofrequency (RF) Safety Overview Massachusetts Environmental Health Association

FCC RF Exposure Report

PUBLIC INFORMATION SESSION ON AMR ELECTRICAL METERS. February 22, 2012 WELCOME

Wireless Facility Engineering Review

Instructions for the TES 593 RF Meter

Measurements of Exposures Around Vodafone New Zealand Limited Cellsites from June 2012 to May 2013

Soundview Cell Tower 1

v1.0.1 March AlphaLab, Inc. All rights reserved. TriField EMF Meter Owner s Manual

Wireless Facility Engineering Review

Modeling Electromagnetic Radiation on Lookout Mountain, Colorado

Questions and Answers about Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields

Before the Federal Communications Commission Washington, D.C

HAZARDS OF NON-IONIZING RADIOFREQUENCY (RF) RADIATION

Essentia Electromagnetic Monitor Model: EM2

Re. Invitation to Comment on a Proposed Small Cell Telecommunications Installation Near (Road reserve) Coogee Bay Road COOGEE NSW 2034

Safety Code 6 Compliance Analysis of NLA031. Study conducted by Eastlink, Radio Frequency Engineering Department

Cell Phone and RF Safety Awareness

Product Safety and RF Energy Exposure Booklet for Mobile Two-Way Radios Installed in Vehicles or as Fixed Site Control Stations ATTENTION!

ELECTROMAGNETIC FIELDS RADIATED BY SMART POWER METERS IN RELATION TO US SAFETY GUIDELINES

March 20, 2018 WATER CONSERVATION INITIATIVE Advanced Metering Infrastructure Michael Lowery, Board of Public Works Tom Holder, Director of Public

Intertek Testing Services ETL SEMKO

Honeywell, Automation and Control Solutions

Honeywell, Automation and Control Solutions

RICHARD TELL ASSOCIATES,INC.

Florida Public Service Commission Staff Workshop on Smart Meters

ARLINGTON COUNTY, VIRGINIA. County Board Agenda Item Meeting of September 15, 2012

8GHz RF EMF Strength Meter

Wireless Facility Radio Frequency Compliance Review

ELECTROMAGNETIC FIELD (EMF) STRENGTH MEASUREMENTS SITE: ROHRERSTOWN ELEMENTARY SCHOOL OCTOBER 16, 2017

Manual Unihan UPWL6580

RF Radiation Safety Training

ITU-D activities on EMF

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

Contact person Date Reference Page Tomas Lennhager P03968-MPE 1 (2) Electronics

Shielding Reduces the RF Radiation from Smart Meters.

Electric Imp, Inc. IMP003-FCC FCC :2014. Report # ELIM NVLAP Lab Code:

COMMUNITY BENEFITS. How Mobile Devices are Used Today (Mobile Device: Cellular Phones, Tablets, etc..)

REVISIONS REV DESCRIPTION DATE APPROVED

Landis+Gyr. S4e MFMM Cellnet User Manual. Bulletin Revision A. DOCUMENT HISTORY Bulletin:

RF-EXPOSURE ASSESSMENT REPORT

Report of Results of Smart Meter RF Testing - Maui Prepared by CASCADIA PM, LLC. And Presented to HAWAII NATURAL ENERGY INSTITUTE

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: WXLRAMV Report No.: LCS E-03 FCC MPE TEST REPORT. 47 CFR FCC Part 2 2.

MEASUREMENTS OF ENVIRONMENTAL ELECTROMAGNETIC FIELDS AT AMATEUR RADIO STATIONS

ITU-T Study Group 5. EMF Environmental Characterization

Technical Note 2. Standards-compliant test of non-ionizing electromagnetic radiation on radar equipment

National Radiation Commission P.O.Box 743, Arusha, Tanzania.

Mobile Telephone Base-station Radio Emission Audit

EMF Test Report: Ericsson Radio 2205 B46

Mobile Telephone Base-station Radio Emission Audit

TABLE OF CONTENTS APPENDIX A... 8 APPENDIX B... 9 APPENDIX C... 12

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

Mobile Telephone Base-station Radio Emission Audit

Mobile Telephone Base-station Radio Emission Audit

IOSH Webinar. Control of Electromagnetic Fields at work regulations 2016 Part 2 EMF exposure assessment 4 th May 2017 Julia Clark FSRP CMIOSH

Before the FEDERAL COMMUNICATIONS COMMISSION Washington, DC COMMENTS OF AMBIENT CORPORATION

TEST REPORT MOBILE MICROWAVE VIDEO TRANMITTER FCC ID: FC3HDX2025D MODEL: HDX-1100S. APPLICANT: VISLINK, Inc. May 7, 2013 PAGE 1 OF 33

Regulatory Framework for RF Safety in Mauritius

Transcription:

CoServ Electric s RF Mesh Advanced Metering Infrastructure RF/EMF Investigation Date Analysis Performed: 05/03/2012

Introduction CoServ Electric is a not-for-profit electric distribution cooperative and, as such, is regulated and directed by its Board of Directors (elected representatives who oversee the operations of the cooperative). These Directors hold a fiduciary responsibility to represent the interests of the Member - our consumers. Surveys show that these Member consumers (made up of residents and business owners across Collin, Denton, Tarrant, Grayson, Wise, and Cooke counties) are tech savvy, and look to CoServ to provide them with resources to save energy and money. In order to meet our Members expectations, our company must innovate and empower our Members with advanced technology to manage energy use. After significant research and an extensive application process, CoServ Electric s Board approved a $17.2 million Department of Energy Smart Grid Investment Grant in March 2010 to support the installation of the AMI project an electric distribution technology initiative called the CoServ ecogrid. In September 2010, CoServ announced its selection of Landis+Gyr s Gridstream RF technology to provide the advanced metering and distribution technology supporting the initiative. The system consists of a robust two-way communications network (a wireless system supported by collectors and routers), advanced metering, distribution automation and personal energy management applications. Once fully deployed, the system will provide operational efficiencies that will reduce costs, streamline operations, improve system reliability, and offer Members new technology to monitor and reduce energy usage in their homes and businesses. CoServ has begun work on full system deployment, with project completion scheduled for April 2013. In that timeframe, all CoServ Members will have an advanced meter installed on, or at, their premise. Radio Frequencies Radio Frequency (RF) is produced by all transmitting devices which are common and in widespread use today. Examples of RF producers include radio broadcast stations, television stations, satellites transmitting services to earth, and even our sun. A normal consequence of RF is the production of an electromagnetic field or EMF. There are three factors for consideration of human exposure to RF 1 : 1. Signal Strength 2. Distance from the transmitting device 3. How often the device transmits 1 An Investigation of Radiofrequency Fields Associated with the Itron Smart Meter, EPRI Technical Report 1021126, December 2010, www.epri.com page 3.

Establishment of Safe Exposure Levels The Federal Communications Commission (FCC) provides the regulatory standards associated with exposure to RF/EMF. IEEE standard C95.1-1191 (ANSI/IEEE C95.1-1992) specifies safe levels of human exposure to radio frequency electromagnetic fields. The FCC has adopted the IEEE standard as the foundation for regulations related to human exposure limits and has been presented as a regulation in 47CFR1.1310. The source document for human EMF exposure limits is now known as Office of Engineering & Technology (OET) Bulletin 65. There have been no changes to the exposure limits. OET Bulletin 65 refers to two safety limits which are Occupational/controlled limits and General population/uncontrolled limits. General population/uncontrolled limits will apply to situations which the general public may be exposed, but not fully aware of, their potential exposure or cannot exercise any control over their exposure. An example of this is a radio transmission tower which is exposing people to EMFs. This definition is the basis for comparisons of regulatory exposure limits to actual field readings taken by CoServ personnel. This is the category CoServ s AMI RF Mesh network, including the AMI meter, falls under. OET Bulletin 65 defines the limits for Maximum Permissible Exposure as values of electric and magnetic field strength and power density for transmitters. For equipment that operates intermittently or in a burst mode such as the AMI meter- OET Bulletin 65 defines the period over which exposure can be averaged and will represent a similar level of exposure as a maximum continuous exposure. This data produces a minimum safe distance to the source. The devices on a Member s residence or business that uses the RF Mesh network are the radio module inside of the meter and the devices used for a Home Area Network (HAN). Table 1 2 below provides the equivalent minimum safe distance in an uncontrolled environment for the mentioned RF sources. RF Mesh Device Residential and C&I modules Home Area Network Radio Home Area Network Device Table 1 Equivalent MSD Uncontrolled Environment 0.63 inches 0.05 inches 0.05 inches As a worse case, this table indicates a person will need to remain 0.63 inches from the radio device in an AMI meter for an exposure limit to be greater than allowed. The distance between the radio and the glass covering the meter is greater than this; so a hazardous exposure is not possible if the normal mode and construction of the system and meter remain intact. Another measurement to be considered with a RF/EMF investigation is the power density of the transmitting device. For this investigation, the RF Mesh devices remain the same. Table 2 3 provides information related to power density in milliwatts per square centimeter (mw/cm 2 ). 2 Landis + Gyr, Acceptable Exposure Limits to Gridstream RF Devices, page 6. 3 Ibid.

RF Mesh Device Max FCC Permissible Exposure F[MHz]/1500 Exposure @ 1 foot from source (Continuous Transmission) Percent of FCC Exposure Limit Exposure at 1 meter (3.28 feet) from source Continuous Transmission) Percent of FCC Exposure Limit Residential and C&I Endpoints 0.6 0.3707 61.78% 0.03 5.6% HAN Endpoint HAN Radio 1.6 0.2852 17.83% 0.03 1.6% Table 2 Review of this information shows that, under normal exposure conditions, the exposure level for the RF Mesh equipment, including the meter, will be below FCC requirements.

Field Analysis Date Analysis Performed: 05/03/2012 Readings Performed by: Kevin Maynard Communications Foreman, CoServ Electric Device Used: NARDA SRM-3006 Serial Number: H-0024 Calibration Date: 03/27/2012 The device used to test EMF is a NARDA SRM-3006 Selective Radiation Meter. It is used to measure RF and EMF levels and is equipped with a spectrum analyzer. The device allows for the determination of EMF and RF strength levels by providing ambient and specific frequencies down to individual components for detailed analysis. The device allows for ability to calculate the maximum permissible exposure for a given frequency. It is equipped with a three axis (iso-tropic) E-field antenna which is a non-directional electrical field measurement antenna. The SRM-3006 captures the signal(s) from the AMI meter and will display in real time the actual pulse of the transmitter and the maximum peak of the transmit packet from the AMI meter. The SRM-3006 samples RF signals in the 902-928 MHz spectrum for approximately 5000 to 6000 cycles with a sweep time of 39 milliseconds at each distance. This cycle duration is adequate to capture transmissions from the AMI meter as it communicates to the RF Mesh network. The SRM-3006 is programmed to show the FCC General Public Access regulatory limit which is displayed as mw/cm 2, mw/m 2, and as a percentage of the FCC limit. Additional programming of the SRM-3006 includes the limits of several other standards and regulatory rules. The frequencies used by the radio module and the HAN device were not investigated as separate frequencies. Therefore, captured power densities will be accumulative of the devices and conclusions will be based on a worst case scenario. Actions Using the SRM-3006, outdoor readings were taken at one (1) foot and three (3) feet distances from the meter for 5 minutes at each distance. Readings were also taken inside of residence at approximately two (2) feet directly behind the meter. Once all of the readings had been completed inside of residence, another reading was taken inside the residence to capture all ambient frequencies which existed in the residence. Readings Location: Outside, 1 foot from meter

Figure 1 - Power Density Findings: Reading is at 274.6 mw/m 2. Conversion to mw/cm 2 divide by 10,000 =.02746 mw/cm 2. Figure 2 - FCC Exposure Percentage Findings: Reading is 4.497% of FCC Exposure percentage. Location: Outside, 3 foot from meter

Figure 3 - Power Density Findings: Reading is at 1.065 µw/cm 2. Conversion to mw/cm 2 divide by 10 = 0.1065 mw/cm 2. Figure 4 - FCC Exposure Percentage Findings: Reading is.202% of FCC Exposure percentage. Location: Inside, 2 feet from meter

Figure 5 - Power Density Findings: Reading is at 2.211 mw/m 2. Conversion to mw/cm 2 divide by 10,000 =.0002211 mw/cm 2. Figure 6 - FCC Exposure Percentage Findings: Reading is.035% of FCC Exposure percentage. Location: Inside Ambient frequencies

Findings: No remarkable findings Comments Members may be able to find a relatively inexpensive meter that claims it provides EMF readings. These meters are typically a wide band product which covers a frequency range of 1MHz to 8GHz and are equipped with a simple omni-directional antenna. It should be noted, these devices are not designed to be frequency specific or a true EMF measurement. These meters will measure fields from all sources that transmit from 1MHz to 8GHz and typically do not measure using E-Field or H-Field. E-

Field is the electrical component and the H-Field is the magnetic component of an EMF field. Conclusions Comparison of FCC Guidelines to the manufacturer s meter specification and the field investigation is shown in the table below. Location/Distance FCC Permissible Power Density (mw/cm 2 ) Manufacturer Spec Power Density (mw/cm 2 ) Calculated Percentage Power Density Measured (mw/cm 2 ) Calculated Percentage to FCC Recorded Percentage to FCC Outside/1 foot 0.6000 0.3707 61.7833% 0.2746 4.5800% 4.4970% Outside/3 foot 0.6000 0.3707 61.7833% 0.1065 0.1775% 0.2020% Inside/2 foot 0.6000 0.3707 61.7833% 0.0002211 0.0369% 0.0350% The RF/EMF emissions from the installed AMI meter at this residence falls well under the requirements of the FCC as defined in OET Bulletin 65. Additionally, the values recorded were under the specifications provided by the vendor of the equipment. An examination of the ambient frequencies in the residence show there are exposures which are naturally occurring and greater in power density than what is contributed by the AMI meter. For more information on AMI and the RF impacts, please refer to EPRI Radio-Frequency Exposure Levels from Smart Meters: A Case Study of One Model CoServ.com FAQ