Moka ATEX MODULAR MULTIFUNC OPERATOR MODULE

Similar documents
Alto ATEX MODULAR MULTIFUNCTION TRANSCEIVER

FREE YOURSELF FROM CABLES! SOLUTIONS. secure solutions for radio control of industrial lifting and handling machinery

Beta. For Ex-hazardous areas COMPACT EASY TO HANDLE FLEXIBLE OPERATOR MODULE

SOLUTIONS BRIEF MOTOTRBO AND SOLAS

ü ( Explosion Protection

Beta. For Ex-hazardous areas COMPACT EASY TO HANDLE FLEXIBLE OPERATOR MODULE

INSTRUCTION MANUAL (ATEX / IECEx)

1- Description CONTENTS

RS Series. électronique. Typical applications : Industrial equipment : Industrial lifting :

Hazardous environments

Isolators A3/1. Vibration Transducer Supply Unit Series

Safety in Hazardous Environments

Temperature Input Module for Zone 1 Series 9482/32

DPharp Differential Pressure and Pressure Transmitters

OPTIWAVE 7300 C Supplementary instructions

PT790 Ex Intrinsically safe TETRA handheld radio.

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Field indicator for current loops with HART communication Models DIH50, DIH52

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Operating Manual. isolate501

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Analog Universal Module HART for Zone 2 Series 9468/33

RADIO emergency stop system

Inductive sensor slot-type SI2-K08-AP7

Accutech DP20. Wireless differential pressure field unit

Binary Output without Power Supply Series 9176

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

in all conditions, where safe communication is fundamental

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Remote Radio Control. WAVE Push button radio control systems

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Accutech GP10. Wireless gauge pressure field unit

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Isolating Repeater Input Series 9163

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Local control stations for Zone 1 and Zone 21. Features. Description

IP26 Series Current to Pneumatic Converter

Ultrasonic level meters ULM 70

TECHNICAL WHITE PAPER STRUCTURAL PRINCIPLE OF A DART CIRCUIT

INTRINSIC SAFETY BASIC PRINCIPLES

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

DTEx Series. Tough. Intrinsically Safe Land Portables. Business Critical Communications

oxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:

ICARUS ELECTRONIC GAS VOLUME CONVERTER

Absolute encoders - SSI EX approval ATEX EEx d IIC T6 Optical single and multiturn encoders 14 bit ST / 12 bit MT

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

High Temperature Velocity and Acceleration Sensor

Binary Output Series 9175

Actuators Series 8602/3

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

Field indicator for current loops with HART communication Models DIH50, DIH52

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

All TXI7850 products are ROHS compliant.

PD795 Ex Intrinsically Safe Digital Portable Two-way Radio

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Accutech AM20. Wireless acoustic monitor field unit

Safety Manual. Omni-ID UHF Tags

Motorola Professional Series ATEX Radios. The choice for professionals in hazardous environments - GP329 Ex, GP339 Ex, ATS2500 Ex and PTX760 Ex

For use in Flammable Gas and Dust Atmospheres

SET Installation and Operating Instructions. Level switch for two sensors

Isolators A3/1.

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Installation and operating instructions manual

NX-230EX NX-330EX. New Product Preliminary Information. VHF Digital & FM Portable Transceiver UHF Digital & FM Portable Transceiver 1.

Digital Input Output Module for Zone 2 Series 9470/33

CE620. Piezoelectric accelerometer with integrated electronics. IECEx

Technical Specification FLUXUS ADM 8127B

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Dust removal filters for combustible dusts Information

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

Accutech AP10. Wireless absolute pressure field unit

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

TQ 422 and TQ 432 / EA 402 / IQS 450. Proximity measuring system. IECEx

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Remote I/O. 74 Remote I/O. Remote I/O System

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Design and applications

KFS. Flap-type flow meter. Design and range of application

Wireless Dual Discrete Input Transmitter Series XYR 5000, Model WW59x Specifications - Americas

Fieldbus Isolating Repeater Series 9185/11

Transcription:

MODULAR MULTIFUNC TION OPERATOR MODULE The Moka operator module adapts to your application to make your process more efficient. This easy-to-use module gives you incomparable freedom of movement, precise quality manoeuvres, and higher productivity while ensuring your operators safety. With the Beta operator module, experience today s cutting-edge technology. This operator module is designed for use in potentially explosive gases atmospheres classified 0,, 2, dust classified 20, 2, 22 and mines. MAIN FEATURES > Configurable, intelligent bi-directional radio link exchanges information while adapting to the radio environment. > User-friendly screen display for look-up, selec- tion, validation, configuration... > Modular unit with wide ranging choice of functions. > Quick and easy product configuration by mini-b USB connector and thanks idialog software (labels, feedback information, alarms, mapping for control devices and outputs, interlockings, network functions, access PINs codes). > Easy to maintain thanks to its diagnostic aid sys- tem (information on screen display, idialog analysis software). > Plug-in battery and rugged industrial charger. FULLY COMPLIANT WITH EUROPEAN DIRECTIVES : ATEX manufacturer 94/9/CE EC type certificate issued by LCIE Machinery directive 2006/42/CE: Emergency stop > SIL 3 per EN 6508--7 > Performance level PL e per EN ISO 3849- and -2 EC type certificate issued by TÜV NORD No 44 250 382580 005 Radio and telecommunication terminal equipment (low voltage, electromagnetic compatibility, radio spectrum) R&TTE 99/5/EC ARCEP certificate

DEFINITION OF A POTENTIALLY EXPLOSIVE ATMOSPHERE Oxidant Explosion How an explosion happens An explosion is formed by an association of the following 3 elements : An oxidant : A fuel : in our case, the oxygen in the air. A gas (methane, acetylene, ) A fume (gasoline, solvent, ) A dust (wood, sugar, grain, ). Fuel A source of ignition : An electric arc A mechanical spark A high temperature Source of ignition Consequences of an explosion Explosions are responsible every year for around 6 deaths and 387 persons with permanent disability (IP) out of 379 accidents. These can produce major catastrophes, such as the explosion at the «AZF» plant at Toulouse (France) in 200 or the «Blaye silo» near Bordeaux (France) in 997, resulting in a large number of deaths and injuries, and destruction of the sites. Protection against explosions It is necessary to evaluate the specifi c hazards created by explosible atmospheres, keeping in mind : the probability that explosible atmospheres will occur and persist, the probability that sources of ignition, including electrostatic discharges, are present and will become active and effective, the installations, substances and methods used, and their possible interactions, the extent of the foreseeable consequences. The explosion hazards must be evaluated globally. In practice, this requires : Identifi cation of zones representing a hazard and substances which could create explosible atmospheres. Classification of the explosive atmospheres in zones where there is an explosion hazard, assisted if necessary, by an outside organization. Defi nition of the equipment required to carry out the project. With reference to user ATEX directive 99/92/CE. The zones are standardised in accordance with their degree of dangerousness. Definition of explosion hazard zones linked to : GASES, FUMES AND FOG ZONE 0 : location where an explosive atmosphere, consisting of a mixture with the air of combustible material in the form of gases, fumes or fog, is present continuously or over extended periods of time, or frequently. ZONE : location where an explosive atmosphere, consisting of a mixture with the air of combustible materials in the form of gases, fumes or fog, is likely to form occasionally under normal operation. ZONE 2 : location where an explosive atmosphere, consisting of a mixture with the air of combustible materials in the form of gases, fumes or fog, is not likely to form during normal operation, or should such a formation occur, is nonetheless only of short duration. DUST ZONE 20 : Location where an explosive atmosphere in the form of a cloud of combustible dust is present in the air continuously, or over extended periods of time, or frequently. ZONE 2 : Location where an explosive atmosphere in the form of a cloud of combustible dust may occasionally form in the air during operation. ZONE 22 : Location where an explosive atmosphere in the form of a cloud of combustible dust is not likely to form in the air during normal operation, or should such a formation occur, is nonetheless only of short duration. Gases /Fumes Dust 2 2 22 0 20 Continuous hazard Hazard present during normal operating conditions Limited hazard in the event of failure of a system (limited in time)

DEFINITION OF MARKINGS ON ATEX - IECEx PRODUCTS Since July st, 2003, all Ex products must satisfy the requirements of the directive ATEX 94/9/CE, the evolution of the standard 60079-0 leads to a new product marking presented in the following tables : Operator modules : 008 II GD Ex ia IIB T4 or T45 C Ga () Ex ia IIIC T35 C or T45 C Da () I M Ex ia I Ma IECEx LCIE 4.005 X LCIE 4 ATEX 304 X 4 5 6 7 8 9 0 2 2 3 () Temperature classes depending on Tamb : 7 Operator modules + cable link 008 II GD Ex ia IIB T4 or T45 C Ga () Ex ia IIIC T35 C or T45 C Da () I M Ex ia I Ma Ui: 5.9V; Ii: 20mA; Pi: 30mW; Ci:75μF; Li: 0.32μH IECEx LCIE 4.005 X LCIE 4 ATEX 304 X 4 5 6 7 8 9 0 2 2 3 3 7 Below are the tables to understand the ATEX marquing : Device group Device group Group I Group II Application Electrical devices intended for use in firedamp mines. (underground work in the mines and parts of ground installations) => Protection against firedamp Electrical devices intended for all other explosible atmospheres than firedamp mines (ground industries) => Protection against explosions 2 3 ATEX classification Category of equipment Flammable substances Degree of protection Description G Gas D Dust Very high level Devices capable of operating in the atmospheres where the risk of explosion is permanent or almost permanent (zones 0,, 2 and 20, 2, 22) 2 G Gas D Dust High level Devices capable of operating in the atmospheres where the risk of explosion is frequent (zones, 2 and 2, 22) 3 G Gas D Dust Normal Devices capable of operating in the atmospheres where the risk of explosion is occasional (zones 2 and 22)

4 Protection modes for electrical equipment in gaseous atmospheres Protection mode Standard Basic principle d Explosion proof enclosure EN/IEC 60079- e Enhanced safety EN/IEC 60079-7 i Intrinsic safety ia EN/IEC 60079- ib EN/IEC 60079- m Encapsulation EN/IEC 60079-8 n Zone 2 EN/IEC 60079-5 o p Immersion in oil Internal overpressure EN/IEC 60079-6 EN/IEC 60079-2 q Powdery fi ller EN/IEC 60079-5 The extremely heavy duty enclosure contains the explosion inside the device. The explosion proof seals of the device prevent any propagation of the flame outside the enclosure. The seals are regularly serviced. The components inside the enclosure must not produce arcs, sparks or dangerous temperatures under normal utilization conditions. The enclosure must be tight to IP 54 and withstand impacts. The actual design of the circuit, where the energy is limited at the entry by a Zener barrier or a galvanic insulator makes it impossible for arcs or electrical sparks to form, subdivided into ia resists 2 defects: suitable for zone 0, and ib resists defect: suitable for zones and 2. The actual design of the circuit, where the energy is limited at the entry by a Zener barrier or a galvanic insulator makes it impossible for arcs or electrical sparks to form, subdivided into ia resists 2 defects: suitable for zone 0, and ib resists defect: suitable for zones and 2. For this protection mode, all the electronics is encapsulated in an insulating material to prevent electrical arcs or electrical sparks. This protection mode is only suitable for devices intended for zone 2 where the risk of explosion is low. It combines the enhanced safety mode e with lower protection requirements. The material or the electrical circuit is immersed in oil. The explosive mixture is located above the liquid and cannot be ignited by the electrical circuit. A pressurized gas is introduced in the enclosure to prevent the possibly-explosive surrounding atmosphere from entering the enclosure. For this protection mode, all the electronics is encapsulated in an inert powdery material to prevent electrical arcs or electrical sparks. Application in ZONE 0 2 5 Classification of gases and fumes by explosion groups (non-exhaustive list) Group IIA Group IIB Group IIC Propane Acetone Ethylene Ethyl oxide Acetylene Ethane Hexane Diethylene Sulphuretted hydrogen Hydrogen Butane Methanol Ethyl ether Ethanol Carbon disulfide Benzene Paint thinners Cycloprodene Pentane Natural gas Butadiene -3 Heptane Propylene oxide 6 Gas temperature classes The safe use of equipment in dangerous areas requires knowledge of the gas group and compare the temperature auto-ignition of gaseous mixtures treated to the temperature of equipment marking. The maximum surface temperature of the material must always be less than the autoignition temperature of the gas present in the dangerous area. Temperature class MAXIMUM surface temperature of electrical equipment Ignition temperatures of FLAMMABLE materials T 450 C > 450 C T2 300 C > 300 C T3 200 C > 200 C T4 35 C > 35 C T5 00 C > 00 C T6 85 C > 85 C

7 Equipment protection level (EPL) Traditional relationship between level of protection and areas / categories (without additional risk assessment). Equipment protection level (EPL) Normal range of application Category (94/9/CE) Ga 0 (and and 2) G Gb (and 2) 2G Gc 2 3G Da 20 (and 2 and 22) D Db 2 (and 22) 2D Dc 22 3D Ma / Mb mines M / M2 8 Protection modes for electrical equipment in dusty atmospheres i Protection mode Standard Basic principle Intrinsic safety ia EN/IEC 60079- ib EN/IEC 60079- m Encapsulation EN/IEC 60079-8 p t Internal overpressure Explosion proof enclosure EN/IEC 60079-2 EN/IEC 60079-3 The actual design of the circuit, where the energy is limited at the entry by a Zener barrier or a galvanic insulator makes it impossible for arcs or electrical sparks to form, subdivided into ia resists 2 defects: suitable for zone 0, and ib resists defect: suitable for zones and 2. The actual design of the circuit, where the energy is limited at the entry by a Zener barrier or a galvanic insulator makes it impossible for arcs or electrical sparks to form, subdivided into ia resists 2 defects: suitable for zone 0, and ib resists defect: suitable for zones and 2. For this protection mode, all the electronics is encapsulated in an insulating material to prevent electrical arcs or electrical sparks. A pressurized gas is introduced in the enclosure to prevent the possibly-explosive surrounding atmosphere from entering the enclosure. The extremely heavy duty envelope contains the explosion inside the device. The explosion proof seals of the device prevent any propagation of the flame outside the enclosure. The seals are regularly serviced. Application in ZONE 20 2 22 9 Classification of dust by explosion groups Explosion groups Group IIIA Type of dust Combustible dust in suspension Fundamental principle Very fine solid particles of nominal size of about 500 microns or less, can be suspended in the air, which can be deposited because of their own weight and that can burn or be consumed in the air and are suceptible to form explosive mixtures with air under conditions of atmospheric pressure and normal temperature. Group IIIB Non-conductive dust Combustible dust electrical resistivity greater than 03 Ω.m. Size < 500 μm Group IIIC Conductive dust Combustible dust electrical resistivity at or below 03 Ω.m. Size < 500 μm 0 Maximum surface temperature for dusty atmospheres 2 3 LCIE : certificate of EC type examination number LCIE : IECEx certificate number Intrinsic safety parameters of cable link

OPERATOR MODULE OPTIONAL MULTIMODES BIDIRECTIONAL RADIO LINK EMERGENCY STOP PALMSWITCH SIL 3 - PL e POSITIONS FOR CONTROL DEVICES IN THE CHOICE TOUGH BACKLIT SCREEN WITH ANTI-REFLECTION, SHOCK-PROOF, ANTI-SCRATCHING FEATURES OPTIONAL CROSS-LOCKING SYSTEM 2-JOYSTICK MODEL CUSTOMIZED FACE PLATE STANDARD JOYSTICKS WITH TO 4 NOTCHES OR PROPORTIONAL CONTROL J2N JN A2 J2W A J2E JW A0 A9 J2S OPTIONAL INTENTIONAL-ACTION JOYSTICKS A8 A7 JE JS A6 A5 A4 A3 A2 A PLM2-08 4 FUNCTION BUTTONS 3-JOYSTICK MODEL ON/VALIDATION BUTTON NAVIGATION BUTTON OPTIONAL AUXILIARY PUSHBUTTON OPTION C6 INDUSTRIAL CONNECTOR 2 DRY CONTACTS CONNECTION OPTION C6 INDUSTRIAL CONNECTOR FOR CABLE LINK OPTIONAL «DEADMAN» DETECTION OPTIONAL ISOLATED WORKER ALARM SYSTEM SEALED USB PORT FOR DIAGNOSTICS, CONFIGURATION 6-PROPORTIONAL LEVERS MODEL OPTIONAL VIBRATOR (ALARM) BREATHABLE MEMBRANE PREVENTS CONDENSATION HIGH-CAPACITY PLUG-IN BATTERY

DESCRIPTION TECHNICAL CHARACTERISTICS ADDITIONAL OPTIONS The operator module comes in 3 housing versions : > Operator module (a) with 2 joysticks : 4 function pushbuttons (b) + 2 positions for control components of your choice (c) > Operator module (a) with 3 joysticks : 4 function pushbuttons (b) + 8 positions for control components of your choice (c) > Operator module (a) with 6 proportional levers : 4 function pushbuttons (b) + 8 positions for control components of your choice (c) (a) Each version has 2 navigation pushbuttons, On/Validation» pushbutton and emergency stop palmswitch. (b) The pushbuttons can be configured as selectors for 2, 3 or «n» positions with status indication on the screen. (c) Choose among the following control devices : - key selector switches - selector switches with 2 fixed positions - 2-position buttons with return to initial position - selector switches with 3 fixed positions - 3-position buttons with return to initial position - 3-position buttons with 2 fixed positions + return to initial position - rotary selector switches with 4 to 2 positions - potentiometer (on operator module 2-joystick model) MECHANICAL CHARACTERISTICS AND ENVIRONMENTAL WITHSTAND CAPACITY Housing material Modified shock-proof polyamide with anti-static charge Tightness IP65 Weight (with battery) From 700 g to 800 g depending on configurations Dimensions 297 x 25 x 70 mm Carried by 2-point shoulder strap ENVIRONMENTAL WITHSTAND CAPACITY Operating temperature range -20 C to + 50 C Storage temperature range of housing alone -20 C to + 70 C Storage temperature range of battery -20 C to + 50 C ELECTRICAL AND RADIO CHARACTERISTICS Power supply Plug-in Li-ion battery Endurance (25 C) with radio link activated 0 hours Frequency selection manual / auto 64 frequencies on 433-434 MHz band 2 frequencies on 869 MHz band 64 frequencies on 9-98 MHz band Transmit power < 0 mw (license free) Range limitation 0 power levels, configurable Modulation FM Average range () 00 m in industrial space () 300 m in open space () Charging time (endurance > 80%) 3 H (20 min of charge get h autonomy) Charging temperature range 0 C to + 40 C C6 INDUSTRIAL CONNECTOR FOR CABLE LINK WITH ALTO ATEX TRANSCEIVER - 7 connection points The screen on the operator module allows you to easily configure and choose items such as : > The screen language > The transceiver which you want to use > The radio transmit frequency and power > The duration of the «standby» time delay (Automatically stops operator module and associated transceiver if not used for a defined period of time) > The various operating modes of the equipment (32 max.) FUNCTIONAL CHARACTERISTICS Display USB interface for configuration and diagnostics Operating indications Function buttons Navigation and startup buttons Emergency stop Standby function Backlit LCD display, 28 x 28 pixels 42mm (L) x 40mm (H) Black / White mini-b 5-point USB connector Easily accessible by cover on back of operator module Visible on screen (radio link status, battery status, status of buttons, information feedback ) 4 pushbuttons (mounted around the screen) + up to 2 positions for control devices of your choice depending on number of joysticks 2 pushbuttons to configure the product On/Validation button (for startup and validation of menus on screen) 2 positions with rotary unlock system User-definable time delay (from s to infinity) It also allows you to view : Battery charge level Radio link status Equipment labels and controlled functions (max 96 different labels for selectors) Equipment information feedback (max 6 feedbacks, with 0 labels per feedback and max 48 labels in whole) Alarms (8 for the use + 8 for the system) () Range varies according to environment conditions around operator module and reception antenna (steel works, metal walls, etc.). Compatibility : These operator modules work with transceivers Elio, Alto, Timo be defined according the application.

ACCESSORIES! IMPORTANT : The battery shall not be charged in potentially explosive area. Slot nb. nb.2 nb.3 nb.4 nb.5 nb.6 Battery charger Reference : PWC Dimensions : 70x65x36 mm Power supply : 2/24 VDC Power : 7w Plug-in battery for operator module Reference : PYB Dimensions : 57x56x6 mm Voltage : 3,7V Capacity : 900mAh Technology : lithium Ion Voltage adapter for battery charger Reference : UBCU Dimensions : 4x72x39 mm Power supply : 5-230VAC Voltage output : 2VDC Power : 7 w Rack for battery chargers (6 slots) Sold without charger Reference : PWR Dimensions : 470x47x8 mm Voltage adapter for the rack Reference : PWAUR Power supply : 00-240VAC Voltage output : 2VDC Power : 36 w Zoé Communication 04 77 49 09 99 Removable shoulder strap Key switch No. 2D38 for cabinet Reference : PYM0 Reference : PWE0 Cable link connection between the operator module and transceiver Reference : PWLY40 Length : 40 meters ZAC La Bâtie Rue Champrond F 38334 SAINT-ISMIER France Tel. +33 (0)4 76 4 44 00 Fax +33 (0)4 76 4 44 44 www.jay-electronique.com The products shown in this document are subject to change. The description, photos and characteristics are not contractually binding. RadioCrane, RadioDrive, RadioSafe, RadioLift, RadioGreen, RadioBuild, RadioFarm, RadioMotion are trademarks of JAY Electronique France. P-0-EN-A d.b