MasterINTERFACE 39 Series - Relay interface modules

Similar documents
MasterINTERFACE 39 Series - Relay interface modules

38 Series - Relay interface modules A

38 Series - Relay interface modules A

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

38 Series - Relay interface modules A. Features /

Multi-voltage Multi-function. Wiring diagram (without control signal)

38 Series - Relay Interface Modules A

83 Series - Modular timers 16 A. Features

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

48 Series - Relay interface modules A. Features

83 SERIES. 83 Series - Modular timers A. Features

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

The power in relays and timers since Catalogue

Modular timers A

Relay interface modules A

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

62 Series - Power relays 16 A. Features / /

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

40 Series - Miniature P.C.B. Relays A

Multi-function 11 pin Plug-in for use with 90 series sockets

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

2 or 4 pole changeover contact Plug-in/Faston 187

30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view

62.22 Copper side view

SMARTimer, digital timer 16 A

87 Series - Modular timers 5-8 A. Features

A rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection

Multi-function 11 pin Plug-in for use with 90 series sockets

CARREL-ELECTRADE LTD not just products... solutions!

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)

CONTA-ELECTRONICS. Relay systems

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

A rated contacts PCB mount - bifurcated terminals. Copper side view

Modular step relays 16 A

Step relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Relay systems. Interface Relay Compact IRC, Multifunction Timing Relay MFR IRC

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

13 SERIES. Electronic step relays A

13 Series - Electronic step relays A. Features SERIES

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)

Time switches 16 A NEON SЕRIES. Heating and cooling. Shop displays. Lighting for parks. Streetlights and car park lighting.

Electronic step, call/reset and monostable relays

Relays, Timers, Interface Modules, Sockets and Accessories Catalogue. The power in relays and timers since 1954

Sensitivity range ( ) kω adjustable Delay time (0.5s or 7s) switch selectable Emptying or filling functions switch selectable

13 Series - Electronic step relays A. Features Residential applications

13 Series - Electronic step/monostable & call/reset relays 8-16 A. Features

Relè di potenza 30 A SЕRIES. Power. generators. Industrial washing machines. Burners, boilers and furnaces. Industrial furnaces and ovens

Mechanical daily time switch. 35 mm rail (EN 60715) mount


02/11/2015

24 V DC, 12 W output 12 V DC, 12 W output 24 V DC, 36 W output

12 Series - Time switches 16 A. Features

05/09/2012

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

02/11/2015

02/11/2015

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Electronic timer CT-TGD.22

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

08/07/2015

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

08/07/2015

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

PART NUMBERING SYSTEM

Electronic timers CT-S range Selection and ordering details

PART NUMBERING SYSTEM

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

02/11/2015

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

22/10/2012

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Electronic timer CT-SDD.22

Type CP-S, CP-C & CP-A Switch mode

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Thermistor motor protection relays

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Electronic timer CT-SDS.22

02/11/2015

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Transcription:

Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic clip Dual screw head (blade+cross) terminals 35mm rail mounting (EN 60715) MasterBASIC For general use in any type of system MasterINTERFACE 39 Series - Relay interface modules EMR Electromechanical Relays 1 CO 6 A 250 V AC High switching capability SSR Solid State Relays 1 solid state output (options 0.1 A 48 V DC, 2 A 24 V DC, 2 A 240 V AC) Silent, high speed switching, long electrical life 39.11 39.10 EMR: 6 to 24 V AC/DC and 230 V AC supply SSR: 6 to 24 V DC and 230 V AC supply MasterPLUS Accepts the output fuse module, for the easy and space efficient protection of output circuits Page 4 Page 5 39.31-39.31.3 39.30-39.30.3 EMR: 6 to 125 V AC/DC, 125 and 220 V DC, 230 V AC supply SSR: 24-125 V AC/DC, 6 to 220 V DC and 230 V AC supply Special 125 and 230 V AC leakage current suppression types (39.31.3 EMR and 39.30.3 SSR) MasterINPUT Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices Fuse option for Outputs Page 6 Page 7 39.41 39.40 EMR: 6 to 24 V and 125 V AC/DC, 230 V AC supply SSR: 6-12 V DC, 24-125 V AC/DC, 230 V AC supply MasterOUTPUT Jumper link option for the quick and easy distribution of supply voltage to output side and its connection to electromagnetic valves and similar output devices Page 8 Page 9 39.21 39.20 EMR: 6 to 24 V and 125 V AC/DC, 230 V AC supply SSR: 6 to 24 V DC, 125 V AC/DC, 230 V AC supply MasterTIMER Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch for selection of 4 time scales and 8 functions Output with fuse module option Page 10 Page 11 39.81 39.80 EMR and SSR: 12 to 24 V AC/DC supply Page 12 Page 13

Typical Applications MasterBASIC 39.11-39.10 For general interface use in any type of system and application. Can be used for input interface applications between auxiliary contacts, sensors etc. and controllers, PLCs or motors. Or for output interface between PLC s controllers and relays, solenoids etc. Output devices MasterPLUS 39.31-39.30-39.31.3-39.30.3 This special version provides extra protection for the output circuit thanks to the replaceable fuse module. For general interface use in any type of system and application. Can be used for input interface applications between auxiliary contacts, sensors etc. and controllers, PLCs or motors. Or for output interface between PLC s controllers and relays, solenoids etc. Output devices Fuse module 093.63 PLC - Output PLC - Output PLC - Input PLC - Input Fuse module 093.63 2 Input devices Input devices

MasterINPUT 39.41-39.40 These models allow the full termination of input device to the interface without the need for additional terminals - saving component cost, time and panel space. Quick and easy distribution of supply voltage through the jumper link on the Bus-Bar (BB) connection. Ideal for interface applications between the auxiliary contacts, sensors, limit switches and Controllers or PLC s. MasterOUTPUT 39.21-39.20 These models allow the full termination of output device to the interface without the need for additional terminals - saving component cost, time and panel space. Quick and easy distribution of supply voltage through the jumper link on the Bus-Bar (BB) connection. Ideal for interface applications between the PLC s or Controllers and output devices such as electomagnetic valves or motors etc.. Output devices Typical Applications MasterTIMER 39.81-39.80 Slim and Multifunction Timed Interface modules. Output devices Fuse module 093.63 PLC - Output PLC - Output PLC - Input Fuse module 093.63 Input devices 3

MasterBASIC - EMR Features 39.11 1 Pole interface module, 6.2 mm wide, ideal for PLC electronic systems Common connection possible with optional jumper links (terminals A1, A2 and 11) 39.11 6 A electromechanical relay 6 to 24 V AC/DC and 230 V AC supply 35 mm rail (EN 60715) mounting For outline drawing see page 20 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) VA Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220 V A Minimum switching load mw (V/mA) Standard contact material Supply specification Nominal voltage (U N ) V DC/AC V AC (50/60 Hz) Rated power VA (50 Hz)/W Operating range Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 μs) kv Dielectric strength between open contacts V AC Ambient temperature range C Protection category Approvals relay (according to type) 1 CO (SPDT) 6 / 10 250 / 400 1,500 300 0.185 6 / 0.2 / 0.12 500 (12 / 10) AgNi 6-12 - 24 220...240 See coil specifications page 16 (0.8...1.1)U N 0.6 U N 0.1 U N (0.8...1.2)U N 10 10 6 60 10 3 5/6 6 (8 mm) 1,000 40 +70 IP 20 4

MasterBASIC - SSR Features 39.10 1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems Common connection possible with optional jumper links (terminals A1, A2 and 13+) 39.10 0.1 or 2 A solid state relay 6 to 24 V DC and 230 V AC supply 35 mm rail (EN 60715) mounting For outline drawing see page 20 Output specification (SSR) Contact configuration Rated current/maximum peak current (10 ms) A Rated voltage/maximum blocking voltage V Switching voltage range V Minimum switching current ma Max. OFF-state leakage current ma Max. ON-state voltage drop V Supply specification Nominal voltage (U N ) V AC (50/60 Hz) V DC Rated power VA (50 Hz) / W Operating range Must drop-out voltage Technical data Operate/release time ms Dielectric strength between input/output V AC Ambient temperature range C Protection category Approvals relay (according to type) 39.10.x.xxx.9024 39.10.x.xxx.7048 39.10.x.xxx.8240 1 NO (SPST-NO) 2/20 DC 0.1/0.5 DC 2/40 AC 24/33 DC 48/60 DC 240/275 AC (1.5 24) DC (1.5 48) DC (12 240) AC 1 0.05 22 0.001 0.001 1.5 0.12 1 1.6 220...240 6-12 - 24 See input specifications page 17 (0.8 1.1) U N 0.1 U N 0.2/0.6 0.04/0.11 12/12 2,500 20 +55 IP20 5

MasterPLUS - EMR Features 39.31 39.31.3 1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 22 Common connection possible with optional jumper links (terminals A1, A2 and 11) 39.31 / 39.31.3 6 A electromechanical relay 6 to 125 V AC/DC, 125 and 220 V DC, 230 V AC supply 35 mm rail (EN 60715) mounting 6 A electromechanical relay Leakage current suppression version, 125 and 230 V AC supply Fuse module 093.63 For outline drawing see page 20 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) VA Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220 V A Minimum switching load mw (V/mA) Standard contact material Supply specification Nominal voltage (U N ) V DC/AC V AC (50/60 Hz) V DC Rated power VA (50 Hz)/W Operating range Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 μs) kv Dielectric strength between open contacts V AC Ambient temperature range C Protection category Approvals relay (according to type) 1 CO (SPDT) 1 CO (SPDT) 6 / 10 6 / 10 250 / 400 250 / 400 1,500 1,500 300 300 0.185 0.185 6 / 0.2 / 0.12 6 / 0.2 / 0.12 500 (12 / 10) 500 (12 / 10) AgNi AgNi 6-12 - 24-60 - 110 125 220...240 110 125-220 240 110 125-220 See coil specifications page 16 See coil specifications page 16 (0.8 1.1) U N (0.8 1.1) U N 0.6 U N 0.6 U N 0.1 U N 0.3 U N 10 10 6 10 10 6 60 10 3 60 10 3 5 / 6 5 / 6 6 (8 mm) 6 (8 mm) 1,000 1,000 40 +70 (+55 for 220 V DC) 40 +70 IP20 IP20 6

MasterPLUS - SSR Features 39.30 39.30.3 1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 22 Common connection possible with optional jumper links (terminals A1, A2 and 13+) 39.30 / 39.30.3 0.1 or 2 A solid state relay 24-125 V AC/DC, 6 to 220 V DC and 230 V AC supply 35 mm rail (EN 60715) mounting 0.1 or 2 A solid state relay Leakage current suppression version, 125 and 230 V AC supply Fuse module 093.63 For outline drawing see page 20 Output specification (SSR) Contact configuration Rated current/maximum peak current (10 ms) A Rated voltage/maximum blocking voltage V Switching voltage range V Minimum switching current ma Max. OFF-state leakage current ma Max. ON-state voltage drop V Supply specification Nominal voltage (U N ) V DC/AC V AC (50/60 Hz) V DC Rated power VA (50 Hz) / W Operating range Must drop-out voltage Technical data Operate/release time ms Dielectric strength between input/output V AC Ambient temperature range C Protection category Approvals relay (according to type) 39.30.x.xxx.9024 39.30.x.xxx.7048 39.30.x.xxx.8240 39.30.3.xxx.9024 39.30.3.xxx.7048 39.30.3.xxx.8240 1 NO (SPST-NO) 1 NO (SPST-NO) 2/20 DC 0.1/0.5 DC 2/40 AC 2/20 DC 0.1/0.5 DC 2/40 AC 24/33 DC 48/60 DC 240/275 AC 24/33 DC 48/60 DC 240/275 AC (1.5 24) DC (1.5 48)DC (12 240) AC (1.5 24) DC (1.5 48)DC (12 240) AC 1 0.05 22 1 0.05 22 0.001 0.001 1.5 0.001 0.001 1.5 0.12 1 1.6 0.12 1 1.6 24-110 125 220...240 110 125-220 240 6-12 - 24-60 - 110 125-220 See input specifications page 17 See input specifications page 17 (0.8 1.1) U N (0.8 1.1) U N 0.1 U N 0.3 U N 0.2/0.6 0.04/0.11 12/12 0.2/0.6 0.04/0.11 12/12 2,500 2,500 20 +55 20 +55 IP20 IP20 7

MasterINPUT - EMR Features 39.41 1 Pole interface module, 6.2 mm wide, ideal for PLC and electronic systems Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices (Bus-bar connection BB) Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 22 Gold plated output contact as standard, for better compatibility with low energy PLC inputs 39.41 6 A electromechanical relay 6-12 - 24-125 V AC/DC and 230 V AC supply 35 mm rail (EN 60715) mounting Fuse module 093.63 For outline drawing see page 20 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) VA Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220 V A Minimum switching load mw (V/mA) Standard contact material Supply specification Nominal voltage (U N ) V DC/AC V AC (50/60 Hz) Rated power VA (50 Hz)/W Operating range Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 μs) kv Dielectric strength between open contacts V AC Ambient temperature range C Protection category Approvals relay (according to type) 1 1 CO (SPDT) 6 / 10 250 / 400 1,500 300 0.185 6 / 0.2 / 0.12 50 (5 / 2) AgNi + Au 6-12 - 24-110 125 220...240 See coil specifications page 16 (0.8 1.1) U N 0.6 U N 0.1 U N 10 10 6 60 10 3 5 / 6 6 (8 mm) 1,000 40 +70 IP20 8

MasterINPUT - SSR Features 1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems Jumper link option for the quick and easy distribution of supply voltage to proximity switches and similar input devices (Bus-bar connection BB) Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 22 39.40 39.40 0.1 or 2 A solid state relay 6-12 V DC, 24-125 V AC/DC and 230 V AC supply 35 mm rail (EN 60715) mounting Fuse module 093.63 For outline drawing see page 20 Output specification (SSR) Contact configuration Rated current/maximum peak current (10 ms) A Rated voltage/maximum blocking voltage V Switching voltage range V Minimum switching current ma Max. OFF-state leakage current ma Max. ON-state voltage drop V Supply specification Nominal voltage (U N ) V DC/AC V AC (50/60 Hz) V DC Rated power VA (50 Hz) / W Operating range Must drop-out voltage Technical data Operate/release time ms Dielectric strength between input/output V AC Ambient temperature range C Protection category Approvals relay (according to type) 39.40.x.xxx.9024 39.40.x.xxx.7048 39.40.x.xxx.8240 1 NO (SPST-NO) 2/20 DC 0.1/0.5 DC 2/40 AC 24/33 DC 48/60 DC 240/275 AC (1.5 24) DC (1.5 48) DC (12 240) AC 1 0.05 22 0.001 0.001 1.5 0.12 1 1.6 24-110...125 220...240 6-12 See input specifications page 17 (0.8 1.1) U N 0.1 U N 0.2/0.6 0.04/0.11 12/12 2,500 20 +55 IP20 9

MasterOUTPUT - EMR Features 1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems Jumper link option for the quick and easy distribution of supply voltage to output side (Bus-bar connection BB) and its connection to electromagnetic valves and similar output devices 39.21 39.21 6 A electromechanical relay 6-12 - 24-125 V AC/DC and 230 V AC supply 35 mm rail (EN 60715) mounting For outline drawing see page 20 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) VA Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220 V A Minimum switching load mw (V/mA) Standard contact material Supply specification Nominal voltage (U N ) V DC/AC V AC (50/60 Hz) Rated power VA (50 Hz)/W Operating range Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 μs) kv Dielectric strength between open contacts V AC Ambient temperature range C Protection category Approvals relay (according to type) 1 1 NO (SPST-NO) 6 / 10 250 / 400 1,500 300 0.185 6 / 0.2 / 0.12 500 (12 / 10) AgNi 6-12 - 24-110 125 220...240 See coil specifications page 16 (0.8 1.1) U N 0.6 U N 0.1 U N 10 10 6 60 10 3 5 / 6 6 (8 mm) 1,000 40 +70 IP20 10

MasterOUTPUT - SSR Features 1 Pole interface modules, 6.2 mm wide, ideal for PLC and electronic systems Jumper link option for the quick and easy distribution of supply voltage to output side (Bus-bar connection BB) and its connection to electromagnetic valves and similar output devices 39.20 39.20 0.1 or 2 A solid state relay 6 to 24 V DC, 125 V AC/DC and 230 V AC supply 35 mm rail (EN 60715) mounting For outline drawing see page 20 Output specification (SSR) Contact configuration Rated current/maximum peak current (10 ms) A Rated voltage/maximum blocking voltage V Switching voltage range V Minimum switching current ma Max. OFF-state leakage current ma Max. ON-state voltage drop V Supply specification Nominal voltage (U N ) V DC/AC V AC (50/60 Hz) V DC Rated power VA (50 Hz) / W Operating range Must drop-out voltage Technical data Operate/release time ms Dielectric strength between input/output V AC Ambient temperature range C Protection category Approvals relay (according to type) 39.20.x.xxx.9024 39.20.x.xxx.7048 39.20.x.xxx.8240 1 NO (SPST-NO) 2/20 DC 0.1/0.5 DC 2/40 AC 24/33 DC 48/60 DC 240/275 AC (1.5 24) DC (1.5 48) DC (12 240) AC 1 0.05 22 0.001 0.001 1.5 0.12 1 1.6 110...125 220...240 6-12 - 24 See input specifications page 17 (0.8 1.1) U N 0.1 U N 0.2/0.6 0.04/0.11 12/12 2,500 20 +55 IP20 11

MasterTIMER - EMR Features 39.81 Slim timed interface module, 6.2 mm wide, ideal for space-saving timing solutions in panels Timer adjustment via top mounted rotary knob, accessible after assembly Control signal terminal DIP-switch for selection of 4 time scales and 8 functions Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 22 Common connection possible with optional jumper links (terminals A1, A2 and 15) 6 A electromechanical relay 12-24 V AC/DC supply 35 mm rail (EN 60715) mounting 39.81 Fuse module 093.63 For outline drawing see page 20 Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) VA Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220 V A Minimum switching load mw (V/mA) Standard contact material Supply specification Nominal voltage (U N ) V AC/DC Rated power AC / DC VA (50 Hz)/W Operating range Holding voltage Must drop-out voltage Technical data Specified time range Repeatability % Recovery time ms Minimum control impulse ms Setting accuracy full range % Electrical life at rated load AC1 cycles Ambient temperature range C Protection category Approvals relay (according to type) AI: On-delay DI: Interval GI: Pulse (0.5 s) delayed SW: Symmetrical flasher (starting pulse on) BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on EE: Interval with control signal off 1 CO (SPDT) 6 / 10 250 / 400 1,500 300 0.185 6 / 0.2 / 0.12 500 (12 / 10) AgNi 12-24 See coil specifications page 16 (0.8 1.1) U N 0.6 U N 0.1 U N (0.1...3)s, (3...60)s, (1...20)min, (0.3...6)h ± 1 50 50 5 60 10 3 20...+50 IP20 12

MasterTIMER - SSR Features Slim timed interface module, 6.2 mm wide, ideal for space-saving timing solutions in panels Timer adjustment via top mounted rotary knob; accessible after assembly Start terminal DIP-switch for selection of 4 time scales and 8 functions Accepts output fuse module 093.63 (for 5 x 20 mm fuses) for quick and easy load protection, see page 22 Common connection possible with optional jumper links (terminals A1, A2 and 15+) 39.80 0.1 or 2 A solid state relay 12-24 V AC/DC supply 35 mm rail (EN 60715) mounting 39.80 Fuse module 093.63 For outline drawing see page 20 Output specification (SSR) Contact configuration Rated current/maximum peak current (10 ms) A Rated voltage/maximum blocking voltage V Switching voltage range V Minimum switching current ma Max. OFF-state leakage current ma Max. ON-state voltage drop V Supply specification Nominal voltage (U N ) V AC/DC Rated power VA (50 Hz) / W Operating range Holding voltage Must drop-out voltage Technical data Specified time range Repeatability % Recovery time ms Minimum control impulse ms Setting accuracy full range % Ambient temperature range C Protection category Approvals relay (according to type) AI: On-delay DI: Interval GI: Pulse (0.5 s) delayed SW: Symmetrical flasher (starting pulse on) BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on EE: Interval with control signal off 39.80.x.xxx.9024 39.80.x.xxx.7048 39.80.x.xxx.8240 1 NO (SPST-NO) 2/20 DC 0.1/0.5 DC 2/40 AC 24/33 DC 48/60 DC 240/275 AC (1.5 24) DC (1.5 48) DC (12 240) AC 1 0.05 22 0.001 0.001 1.5 0.12 1 1.6 12-24 See input specifications page 17 (0.8 1.1) U N 0.6 U N 0.1 U N (0.1...3)s, (3...60)s, (1...20)min, (0.3...6)h ± 1 50 50 5 20...+50 IP20 13

39 Series - Relay interface modules - Ordering information Ordering information Example: MasterPLUS 39 series screw terminal interface module, electromechanical relay output, 1 CO (SPDT), 24 V AC /DC coil. 3 9 A B C D. 3 1. 0. 0 2 4. 0 0 6 0 Series Type 1 = MasterBASIC, screw terminal 3 = MasterPLUS, screw terminal, fuse-protectable output 4 = MasterINPUT, screw terminal, fuse-protectable output 2 = MasterOUTPUT, screw terminal 8 = MasterTIMER multifunction, screw terminal, fuse-protectable output No. of poles 1 = 1 CO (only EMR, except 39.21, 1 NO) 0 = 1 NO (only SSR) Coil version, EMR / Input version, SSR 0 = AC (50/60 Hz) / DC 3 = Leakage current suppression AC (50/60 Hz) 7 = DC sensitive 8 = AC (50/60 Hz) Coil voltage, EMR / Input voltage, SSR See: Coil specification, EMR / Input specification, SSR D: Special Version, EMR 0 = Standard C: Options, EMR 6 = Standard B: Contact circuit, EMR 0 = CO A: Contact material, EMR 0 = AgNi Standard 4 = AgSnO 2 5 = AgNi + Au (5 μm) ABCD: Output version, SSR 7048 = 0.1 A - 48 V DC 8240 = 2 A - 230 V AC 9024 = 2 A - 24 V DC EMR - Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Coil version A B C D 39.11 0.006-0.012 0.024-8.230 0-4 - 5 0 6 0 0.006-0.012 0.024-0.060 39.31 0.125-8.230 0-4 - 5 0 6 0 7.125-7.220 3.125-3.230 0.006-0.012 39.41 0.024-0.125 0-4 - 5 0 6 0 8.230 0.006-0.012 39.21 0.024-0.125 0-4 - 5 0 6 0 8.230 39.81 0.012-0.024 0 0 6 0 SSR - Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Input version Output version, ABCD 39.10 7.006-7.012 7.024-8.230 7.006-7.012 7.024-7.060 7048-8240 - 9024 39.30 7.125-7.220 0.024-0.125 7048-8240 - 9024 8.230 3.125-3.230 7.006-7.012 39.40 0.024-0.125 7048-8240 - 9024 8.230 7.006-7.012 39.20 7.024-0.125 7048-8240 - 9024 8.230 39.80 0.012-0.024 7048-8240 - 9024 14

39 Series - Relay interface modules - Technical data Technical data Insulation according to EN 61810-1 Nominal voltage of supply system V AC 230 / 400 Rated insulation voltage V AC 250 400 Pollution degree 3 2 Insulation between coil and contact set Type of Insulation Reinforced Overvoltage category III Rated impulse voltage kv (1.2/50) μs 6 Dielectric strength V AC 4,000 Insulation between open contacts (EMR) Type of disconnection Micro-disconnection Dielectric strength V AC / kv (1.2/50) μs 1,000 / 1.5 Conducted disturbance immunity U N 60 V U N = 125 V U N = 230 V Fast transients (burst 5/50 ns, 5 khz) according to EN 61000-4-4 4 kv 4 kv 4 kv at supply terminals Voltage pulses (surge 1.2/50 μs) according to EN 61000-4-5 0.8 kv 2 kv 4 kv at supply terminals (differential mode) Other data Bounce time (EMR) : NO/NC ms 1/6 Vibration resistance (EMR,10..55 Hz): NO/NC g 10/5 Power lost to the environment without contact current W 0.2 (24 V) 0.4 (230 V) with rated current W 0.6 (24 V) 0.9 (230 V) Terminals Wire strip length mm 10 Screw torque Nm 0.5 Solid and stranded cable Max. wire size mm 2 1 x 2.5 / 2 x 1.5 AWG 1 x 14 / 2 x 16 Min. wire size mm 2 1 x 0.2 AWG 1 x 24 Contact specification (EMR) F 39 - Electrical life (AC) v contact current H 39 - Maximum DC1 breaking capacity Cycles Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 DC breaking current (A) DC voltage (V) When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of 60 10 3 can be expected. In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. 15

Coil specifications - Electromechnical Relay Coil data sensitive DC, type 39.31 Nominal Coil Operating range Must drop- Rated input Rated voltage code out voltage current at U N power U N U min U max U r I N at U N V V V V ma W 125 (110...125) 7.125 88 138 12.5 4.6 0.6 220 7.220 176 242 22 3.0 0.6 39 Series - Relay interface modules - Technical data Coil data AC/DC, type 39.11/21/31/41 Nominal Coil Operating range Must drop- Rated input Rated voltage code out voltage current at U N power U N U min U max U r I N at U N V V V V ma VA / W 6 0.006 4.8 6.6 0.6 35 0.2 / 0.2 12 0.012 9.6 13.2 1.2 15 0.2 / 0.2 24 0.024 19.2 26.4 2.4 11 0.25 / 0.25 60 (1) 0.060 48 66 6.0 5.7 0.35 / 0.35 125 (2) 0.125 88 138 12.5 5.6 0.7 / 0.7 (110 125) (1) 60 V AC/DC for type 39.31 only (2) 125 V AC/DC for types 39.21/31/41 only Coil data AC, type 39.11/21/31/41 Nominal Coil Operating range Must drop- Rated input Rated voltage code out voltage current at U N power U N U min U max U r I N at U N V V V V ma VA / W 230 (230..240) 8.230 184 264 23 4.3 1 / 0.4 Coil data leakage current suppression versions, type 39.31.3 Nominal Coil Operating range Must drop- Rated input Rated voltage code out voltage current at U N power U N U min U max U r I N at U N V V V V ma VA / W 125 (110 125) 3.125 88 138 44 8.4 1.1 / 1 230 (230..240) 3.230 184 264 72 5.9 1.4 / 0.5 The 39 Series interface modules (supply version 3) have built-in leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at (110...125)V AC and (230...240)V AC. This problem can occur, for example, when connecting the interface modules to PLC s with triac outputs or when connecting via relatively long cables. Coil data AC/DC timer, type 39.81 Nominal Coil Operating range Must drop- Rated input Rated power at U N voltage code (AC/DC) out voltage current at U N U N U min U max U r DC AC DC AC V V V V ma ma W VA / W 12 0.012 9.6 13.2 1.2 15 23 0.2 0.3 / 0.2 24 0.024 19.2 26.4 2.4 11 19 0.25 0.4 / 0.3 16

39 Series - Relay interface modules - Technical data Input specifications - Solid State Relay Input data sensitive DC, type 39.10/20/30/40 Nominal Input Operating range Must drop- Rated input Rated voltage code out voltage current at U N power U N U min U max U r I N at U N V V V V ma W 6 7.006 4.8 6.6 0.6 7.5 0.2 12 7.012 9.6 13.2 1.2 20.7 0.25 24 (1) 7.024 19.2 26.4 2.4 10.5 0.25 60 (2) 7.060 48 66 6.0 6.4 0.4 125 (2) (110...125) 7.125 88 138 12.5 4.6 0.6 220 (2) 7.220 176 242 22 3.0 0.6 (1) 24 V DC for type 39.10/20/30 only (2) 60 V DC, 125 V DC and 220 V DC for type 39.30 only Input data AC/DC, type 39.20/30/40 Nominal Input Operating range Must drop- Rated input Rated voltage code out voltage current at U N power U N U min U max U r I N at U N V V V V ma VA / W 24 (3) 0.024 19.2 26.4 2.4 17.5 0.4 / 0.3 125 (110 125) 0.125 88 138 12.5 5.5 0.7 / 0.7 (3) 24 V AC/DC for type 39.30/40 only Input data AC, type 39.10/20/30/40 Nominal Input Operating range Must drop- Rated input Rated voltage code out voltage current at U N power U N U min U max U r I N at U N V V V V ma VA / W 230 (230..240) 8.230 184 264 23 4.2 1 / 0.4 Input data leakage current suppression versions, type 39.30.3 Nominal Input Operating range Must drop- Rated input Rated voltage code out voltage current at U N power U N U min U max U r I N at U N V V V V ma VA / W 125 (110 125) 3.125 88 138 44 8.4 1.1 / 1 230 (230..240) 3.230 184 264 72 5.9 1.4 / 0.5 The 39 Series interface modules (supply version 3) have built-in leakage current suppression to address industry concerns of the contacts not dropping-out when there is residual current in the circuit; at (110...125)V AC and (230...240)V AC. This problem can occur, for example, when connecting the interface modules to PLC s with triac outputs or when connecting via relatively long cables. Input data AC/DC timer, type 39.80 Nominal Input Operating range Must drop- Rated input Rated power at U N voltage code (AC/DC) out voltage current at U N U N U min U max U r DC AC DC AC V V V V ma ma W VA / W 12 0.012 9.6 13.2 1.2 15 23 0.2 0.3 / 0.2 24 0.024 19.2 26.4 2.4 11 19 0.25 0.4 / 0.3 17

39 Series - Timed interface modules Timer specifications EMC specifications Type of test Reference standard Electrostatic discharge contact discharge EN 61000-4-2 4 kv air discharge EN 61000-4-2 8 kv Radio-frequency electromagnetic field (80 1,000 MHz) EN 61000-4-3 10 V/m (1,400 2,700 MHz) EN 61000-4-3 10 V/m Fast transients (burst) (5-50 ns, 5 and 100 khz) on Supply terminals EN 61000-4-4 4 kv on control signal terminals EN 61000-4-4 4 kv Surges (1.2/50 μs) on supply and control common mode EN 61000-4-5 2 kv signal terminals differential mode EN 61000-4-5 0.8 kv Radio-frequency common mode (0.15 80 MHz) on Supply terminals EN 61000-4-6 10 V on control signal terminals EN 61000-4-6 3 V Radiated and conducted emission EN 55022 class B Other data Bounce time (EMR) : NO/NC ms 1/6 Vibration resistance (EMR,10..55 Hz): NO/NC g 10/5 Power lost to the environment without contact current W 0.3 with rated current W 0.8 Terminals Wire strip length mm 10 Screw torque Nm 0.5 Solid and stranded cable Max. wire size mm 2 1 x 2.5 / 2 x 1.5 AWG 1 x 14 / 2 x 16 Min. wire size mm 2 1 x 0.2 AWG 1 x 24 Times scales 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 (0.1...3)s (3...60)s (1...20)min (0.3...6)h Functions LED Supply voltage NO contact/output OFF Open ON Open ON Open (timing to close in progress) ON Closed 18

39 Series - Timed interface modules Wiring diagram U = Supply voltage S = Signal switch = Output contact Without control signal 1 2 3 4 5 1 2 3 4 5 (AI) On-delay Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. (DI) Interval Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 1 2 3 4 5 1 2 3 4 5 (GI) Pulse (0.5s) delayed Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs after a fixed time of 0.5s. (SW) Symmetrical flasher (starting pulse on) Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off). With control signal 1 2 3 4 5 (BE) Off-delay with control signal Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. * * With DC supply, positive polarity has to be conneted to B1 terminal (according to EN 60204-1). 1 2 3 4 5 1 2 3 4 5 (CE) On- and off-delay with control signal Power is permenently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset. (DE) Interval with control signal on Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. 1 2 3 4 5 (EE) Interval with control signal off Power is permenently applied to the timer. On opening of the Signal Switch (S) the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. Possible to control an external load, such as another relay coil or timer, connected to the signal start terminal B1. ** A voltage other than the supply voltage can be applied to the command Start (B1), example: A1 - A2 = 24 V AC B1 - A2 = 12 V DC 19

Outline drawings 39.10 39.11 39.20 39.21 39.30 / 39.30.3 39.31 / 39.31.3 39.40 39.41 39.80 39.81 20

Example:.xxxx.9024.7048.8240 Electromechanical Relay (1 Pole 6 A) & Socket Combinations Interface Module Code Coil voltage Relay Socket MasterBASIC 39.11.0.006.0060 6 V AC/DC 34.51.7.005.0010 93.61.7.024 39.11.0.012.0060 12 V AC/DC 34.51.7.012.0010 93.61.7.024 39.11.0.024.0060 24 V AC/DC 34.51.7.024.0010 93.61.7.024 39.11.8.230.0060 (230...240)V AC 34.51.7.060.0010 93.61.8.230 MasterPLUS 39.31.0.006.0060 6 V AC/DC 34.51.7.005.0010 93.63.7.024 39.31.0.012.0060 12 V AC/DC 34.51.7.012.0010 93.63.7.024 39.31.0.024.0060 24 V AC/DC 34.51.7.024.0010 93.63.7.024 39.31.0.060.0060 60 V AC/DC 34.51.7.060.0010 93.63.7.060 39.31.0.125.0060 (110...125)V AC/DC 34.51.7.060.0010 93.63.0.125 39.31.8.230.0060 (230...240)V AC 34.51.7.060.0010 93.63.8.230 39.31.7.125.0060 (110...125)V DC 34.51.7.060.0010 93.63.7.125 39.31.7.220.0060 220 V DC 34.51.7.060.0010 93.63.7.220 39.31.3.125.0060 (110...125)V AC 34.51.7.060.0010 93.63.3.125 39.31.3.230.0060 (230...240)V AC 34.51.7.060.0010 93.63.3.230 MasterINPUT 39.41.0.006.5060 6 V AC/DC 34.51.7.005.5010 93.64.0.024 39.41.0.012.5060 12 V AC/DC 34.51.7.012.5010 93.64.0.024 39.41.0.024.5060 24 V AC/DC 34.51.7.024.5010 93.64.0.024 39.41.0.125.5060 (110 125) V AC/DC 34.51.7.060.5010 93.64.0.125 39.41.8.230.5060 (230...240)V AC 34.51.7.060.5010 93.64.8.230 MasterOUTPUT 39.21.0.006.0060 6 V AC/DC 34.51.7.005.0010 93.62.7.024 39.21.0.012.0060 12 V AC/DC 34.51.7.012.0010 93.62.7.024 39.21.0.024.0060 24 V AC/DC 34.51.7.024.0010 93.62.7.024 39.21.0.125.0060 (110 125) V AC/DC 34.51.7.060.0010 93.62.0.125 39.21.8.230.0060 (230...240)V AC 34.51.7.060.0010 93.62.8.230 MasterTIMER 39.81.0.012.0060 12 V AC/DC 34.51.7.012.0010 93.68.0.024 39.81.0.024.0060 24 V AC/DC 34.51.7.024.0010 93.68.0.024 Solid State Relay (1 Pole 0.1 or 2 A) & Socket Combinations Interface Module Code Input voltage Relay Socket MasterBASIC 39.10.7.006.xxxx 6 V DC 34.81.7.005.xxxx 93.61.7.024 39.10.7.012.xxxx 12 V DC 34.81.7.012.xxxx 93.61.7.024 39.10.7.024.xxxx 24 V DC 34.81.7.024.xxxx 93.61.7.024 39.10.8.230.xxxx (230...240)V AC 34.81.7.060.xxxx 93.61.8.230 MasterPLUS 39.30.7.006.xxxx 6 V DC 34.81.7.005.xxxx 93.63.7.024 39.30.7.012.xxxx 12 V DC 34.81.7.012.xxxx 93.63.7.024 39.30.7.024.xxxx 24 V DC 34.81.7.024.xxxx 93.63.7.024 39.30.7.060.xxxx 60 V DC 34.81.7.060.xxxx 93.63.7.060 39.30.7.125.xxxx (110...125)V DC 34.81.7.060.xxxx 93.63.7.125 39.30.7.220.xxxx 220 V DC 34.81.7.060.xxxx 93.63.7.220 39.30.0.024.xxxx 24 V AC/DC 34.81.7.024.xxxx 93.63.0.024 39.30.0.125.xxxx (110...125)V AC/DC 34.81.7.060.xxxx 93.63.0.125 39.30.8.230.xxxx (230...240)V AC 34.81.7.060.xxxx 93.63.8.230 39.30.3.125.xxxx (110...125)V AC 34.81.7.060.xxxx 93.63.3.125 39.30.3.230.xxxx (230...240)V AC 34.81.7.060.xxxx 93.63.3.230 MasterINPUT 39.40.7.006.xxxx 6 V DC 34.81.7.005.xxxx 93.64.0.024 39.40.7.012.xxxx 12 V DC 34.81.7.012.xxxx 93.64.0.024 39.40.0.024.xxxx 24 V AC/DC 34.81.7.024.xxxx 93.64.0.024 39.40.0.125.xxxx (110 125) V AC/DC 34.81.7.060.xxxx 93.64.0.125 39.40.8.230.xxxx (230...240)V AC 34.81.7.060.xxxx 93.64.8.230 MasterOUTPUT 39.20.7.006.xxxx 6 V DC 34.81.7.005.xxxx 93.62.7.024 39.20.7.012.xxxx 12 V DC 34.81.7.012.xxxx 93.62.7.024 39.20.7.024.xxxx 24 V DC 34.81.7.024.xxxx 93.62.7.024 39.20.0.125.xxxx (110 125) V AC/DC 34.81.7.060.xxxx 93.62.0.125 39.20.8.230.xxxx (230...240)V AC 34.81.7.060.xxxx 93.62.8.230 MasterTIMER 39.80.0.012.xxxx 12 V AC/DC 34.81.7.012.xxxx 93.68.0.024 39.80.0.024.xxxx 24 V AC/DC 34.81.7.024.xxxx 93.68.0.024 21

Accessories Output fuse module for 39.31/30/41/40/81/80 types 093.63 - Patent-pending solution for easy load protection - For 5 x 20 mm fuses up to 6 A, 250 V - Easy visibility of the fuse condition through the window - Quick connection to socket 093.63 Multi-state fuse module 0. As delivered, the socket comes without a fuse module. However, the absent fuse is internally replaced with an electrical link - which allows the interface relay to be used without a fuse module. In this state, the peg/indicator is visually hidden (position A). 1. With fuse module inserted, the fuse is positioned electrically in series with the common output terminal of the interface module (11 for EMR versions, 13+ for SSR versions, 15 for EMR timer, 15+ for SSR timer). This state is indicated by the peg/indicator seen in position B. 2. If the fuse module is extracted (for example; because the fuse element has blown) the output circuit will be locked open, as this will generally be the safe option. This state is indicated by the peg/indicator seen in position C. 3. In order to reinstate the output circuit it is necessary to either re-insert the fuse module (complete with functional fuse), or alternatively, return the peg/indicator to position A by gently applying pressure in the direction of the arrow. 0. Peg/indicator in position A (standard on delivered sockets) 1. Peg/indicator in position B (after fuse module inserted into socket) 2. Peg/indicator in position C (after removal of fuse module from socket) 3. Return the peg/indicator to position A 22

Accessories 093.16 16-way jumper link 093.16 (blue) 093.16.0 (black) 093.16.1 (red) Rated values 36 A - 250 V Possibility of multiple connection, side by side 093.16.0 093.16.1 Dual-purpose plastic separator (1.8 mm or 6.2 mm separation) 093.60 1. By breaking off the protruding ribs (by hand), the separator becomes only 1.8 mm thick; useful for the visual separation of different groups of interfaces, or necessary for the protective separation of different voltages of neighbouring interfaces, or for the protection of cut ends of jumper links. 093.60 2. Leaving the ribs in place provides 6.2mm separation. Simply cutting (with scissors) the relevant segment(s) permits the interconnection across the separator of 2 different groups of interface relays, using the standard jumper link. Sheet of marker tags, plastic, 72 tags, 6x12 mm 060.72 060.72 23