USER'S MANUAL TBM061 TBM062 TBM063 TBM065

Similar documents
USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

Category III 600 Volts ac and dc.

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

USER'S MANUAL. ACD-16 Pro ACD-16 TRMS Pro ACD-40PQ

BM22s, BM25s, BM25a & BM27s USER'S MANUAL

USER'S MANUAL. BM151s, BM152s, BM155s, & BM351s PowerClamp TM Series

USER'S MANUAL BM151 BM152 BM155. PowerClamp TM Series

USER'S MANUAL. BM315 BM319 Automotive Multimeter

ACD-15 Pro & ACD-15 TRMS Pro Clamp-on Multimeter Series

ACD-14 FX ACD-14 TRMS FX

200Amp AC Clamp Meter + NCV Model MA250

USER'S MANUAL TIS 859, TIS 849 & TIS 839 Voltage Tester

USER'S MANUAL DMR-6700

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User s Guide. Digital AC/DC Clamp Meter Model 38394

User Guide. Digital AC/DC Clamp Meter Model 38394

DM-45 Digital Multimeter

AC/DC CLAMP METER USER S MANUAL

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

400Amp True RMS AC Clamp Meter + NCV

USER'S MANUAL BM878, BM877 & BM876 Insulation Tester Combination Multimeter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

USER'S MANUAL. BM811s BM812s BM815s BM817s

400Amp True RMS AC/DC Clamp Meter Model EX613

NOTE: Fully read and understand this manual before using this Digital Multimeter.

DMM8900 SERIES USERS MANUAL

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

AM-250. Digital Multimeter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

DM-46 Instruction Manual

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

User s Guide. MultiMaster Digital MultiMeter Series With PC Interface. Models: MM560A MM570A

PM55A. Automatic Precision Pocket Meter. English. Users Manual. PN July Amprobe Test Tools. All rights reserved.

312, 316, 318. Clamp Meter. Users Manual

DM-46 Instruction Manual

Autoranging Multimeter Extech EX503

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

Pen Multimeter. Model

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

AMM-1022 Digital Multimeter USER`S MANUAL

600A Clamp Meters w/tightsight Display

Electrical Multimeter

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

UT207A/208A/209A Operating Manual. Table of Contents

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

ET-3888 True RMS Clamp Meter. User Manual

USER'S MANUAL TBM251 TBM252 TBM255 TBM257

User s Guide. Model MA A AC Mini Clamp-on Meter

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

USER'S MANUAL DMR-4350

OPERATOR S INSTRUCTION MANUAL

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Digital Clamp Meter (TRMS) Model : 2727

Sales: Technical: Fax:

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

KMD-S04 Multímetro de bolsillo

USER'S MANUAL DMR-4300

BENNING. CM7 Electrical Tester. Service Information

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

User Manual Digital Multimeter. model no.: MSR-U1000

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

MW3105 DIGITAL CLAMP MULTIMETER

DVM1190 DIGITAL MULTIMETER

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

ACD-45PQ. 600A Power Quality Clamp. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

Mini Clamp Meter Model:

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

79/26 Series III Multimeter

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

USER S MANUAL DMR-1500

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

AC68C. Users Manual. True RMS AC/DC Clamp Multimeter. PN July Amprobe Test Tools. All rights reserved.

ICM 136R Operating Instruction Electrical Clamp-Multimeter

netzerotools.com 374/375/376 Users Manual Clamp Meter

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

Pen-type DIGITAL MULTITESTER

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

MS2030 CAT III 600 V A V AUTO RS232

USER'S MANUAL DMR-2400

AUTORANGING TRUE RMS MULTIMETER USER GUIDE. INST151 Doc 1.00

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Transcription:

USER'S MANUAL TBM061 TBM062 TBM063 TBM065 Compact AC/DC Clamp-on Multimeter Series

1 1) SAFETY This manual contains information and warnings that must be followed for operating the instrument safely and maintaining the instrument in a safe operating condition. If the instrument is used in a manner not specified by the manufacturer, the protection provided by the instrument may be impaired. The meter protection rating, against the users, is double insulation per IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed., CAN/CSA C22.2 No. 61010-1, 2nd Ed., IEC61010-2-032, EN61010-2-032, UL61010B-2-032 and CAN/CSA C22.2 No. 61010-2-032-04: Category CAT III 600V AC & DC. PER IEC61010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY II Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from the fixed installation. Note Examples include household, office, and laboratory appliances. OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. Note Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation. OVERVOLTAGE CATEGORY IV Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. Note Examples include electricity meters and primary over-current protection equipment. TERMS IN THIS MANUAL WARNING identifies conditions and actions that could result in serious injury or even death to the user. CAUTION identifies conditions and actions that could cause damage or malfunction in the instrument.

2 WARNING To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. The meter is intended only for indoor use. To avoid electrical shock hazard, observe the proper safety precautions when working with voltages above 60 VDC or 30 VAC rms. These voltage levels pose a potential shock hazard to the user. Keep your hands/fingers behind the hand/finger barriers (of the meter and the test leads) that indicate the limits of safe access of the hand-held part during measurement. Inspect test leads, connectors, and probes for damaged insulation or exposed metal before using the instrument. If any defects are found, replace them immediately. This Clamp-on meter is designed to apply around or remove from uninsulated hazardous live conductors. But still, individual protective equipment must be used if hazardous live parts in the installation where measurement is to be carried out could be accessible. CAUTION Disconnect the test leads from the test points before changing meter functions. INTERNATIONAL ELECTRICAL SYMBOLS! Caution! Refer to the explanation in this Manual Caution! Risk of electric shock Earth (Ground) Double Insulation or Reinforced insulation Fuse AC--Alternating Current DC--Direct Current Application around and removal from hazardous live conductors is permitted 2) CENELEC Directives The instruments conform to CENELEC Low-voltage directive 2006/95/EC and Electromagnetic compatibility directive 2004/108/EC

3 3) PRODUCT DESCRIPTION Note: Top of the line model is used as representative for illustration purposes. Please refer to your respective model for function availability. 1) Hall-effect Clamp Jaw for AC & DC current magnetic field pick up 2) Hand/Finger Barrier to indicate the limits of safe access of the meter during measurement 3) Push-buttons for special functions & features 4) Input Jack for all functions EXCEPT non-invasive ACA & DCA current functions 5) Common (Ground reference) Input Jack for all functions EXCEPT non-invasive ACA & DCA current functions 6) Slide-switch Selector to turn the power ON/OFF and Select a function 7) 3-3/4 digits 4000 counts LCD display 8) Jaw trigger for opening the clamp jaw 9) DCA direction for + polarity as well as Jaw center Indicator, at where best ACA & DCA accuracy is specified

4 4) OPERATION CAUTION: Before and after hazardous voltage measurements, test the voltage function on a known source such as line voltage to determine proper meter functioning. DC Voltage, AC Voltage, Hz Frequency functions Set slide-switch to Voltage function position. Inputs are made through the test leads terminals. For Models 063 & 065, slide-switch on defaults at AC voltage. Press SELECT button momentarily to select DC voltage. For Models 061& 062, separate ACV & DCV slide-switch positions are being used. Press the Hz button momentarily to activate Hz Frequency. The Hz trigger level is determined by the selected function-range from where the Hz function is activated. In ACV function, activating the Hz function during significant measurements can get the most appropriate trigger level to avoid electrical noises in most cases. Electrical noise may cause unstable Hz reading. Activating the Hz function at AC 4.000V range (before making significant measurements) can get lower trigger level (higher sensitivity). Hz reading may show zero when the sensitivity is insufficient.

5 Note: DC 400.0mV range is designed with 1000M high input impedance for least current drain in measuring small signals, and can cope better with most commercially available voltage output transducers/adapters. The non-zero display reading is normal when the meter inputs are open circuit, which will not affect actual measurement accuracy. The meter will show close-to-zero readings when the inputs are shorted. Open input is actually a floating condition, which is not a zero-volt-input condition. ACA & DCA Current clamp-on function Inputs are made through the clamp jaws for non-invasive ACA & DCA current measurements. CAUTION (Application and removal of the Clamp-on meter) Press the jaw trigger and clamp the jaws around only one single conductor of a circuit for load current measurement. Make sure the jaws are completely closed, or else it will introduce measurement errors. Enclosing more than one conductor of a circuit will result in differential current measurement (like identifying leakage current). Locate the conductor(s) at the Jaws center as much as possible to get the best measuring accuracy. The jaw + mark indicates current flow direction on DCA positive readings.

For removal, press the jaw trigger and remove the jaws from the conductor(s). Note: In DCA measurements, hysteresis of the jaws (after measuring high DC currents) may introduce non-zero residual readings. Relative Zero mode should be used each time to offset the residual readings, if any, for more accurate measurements. Adjacent current-carrying devices such as transformers, motors and conductor wires will affect measurement accuracy. Keep the jaws away from them as much as possible to minimize influence. 6 Resistance, and Continuity functions CAUTION Using Resistance, Continuity or Diode function in a live circuit will produce false results and may damage the instrument. In many cases the suspected component must be disconnected from the circuit to obtain an accurate measurement reading Inputs are made through the test leads terminals. Slide-switch on defaults at. Press SELECT button momentarily to select Continuity function which is convenient for checking wiring connections and operation of switches. A continuous beep tone indicates a complete wire.

Diode test function Inputs are made through the test leads terminals. Slide-switch on defaults at. Press SELECT button momentarily 2 times to select Diode test function. Normal forward voltage drop (forward biased) for a good silicon diode is between 0.400V to 0.900V. A reading higher than that indicates a leaky diode (defective). A zero reading indicates a shorted diode (defective). An OL indicates an open diode (defective). Reverse the test leads connections (reverse biased) across the diode. The digital display shows OL if the diode is good. Any other readings indicate the diode is resistive or shorted (defective). Capacitance function Inputs are made through the test leads terminals. Slide-switch on defaults at. Press SELECT button momentarily 3 times to select Capacitance function. Relative zero mode can be used to zero out the parasitic capacitance of the leads and the internal protection circuitry of the meter when measuring low capacitance in the order of Pico Farad (pf). CAUTION Discharge capacitors before making any measurement. Large value capacitors should be discharged through an appropriate resistance load 7

Temperature function (Model 065 & 063 only) 8 Be sure to insert the banana plug type-k temperature bead probe Bkp60 with correct polarities. Slide-switch on defaults at degree C (Celsius). Press SELECT button momentarily to select degree F (Fahrenheit). You can also use a plug adapter Bkb32 (Optional purchase) with banana pins to type-k socket to adapt other type-k standard mini plug temperature probes. HOLD The Hold feature freezes the display for later viewing. Press the HOLD momentarily to toggle to the Hold feature. The annunciator turns on. button MAX The max feature compares and displays the measured maximum value as fast as

9 30ms with auto-ranging capability. It allows the meter to capture in-rush currents in current functions. Press and hold the MAX button for 1 second or more to toggle to the max feature. The annunciators MAX and turn on. Relative Zero mode Relative Zero mode allows the user to offset the meter consecutive measurements with the displaying reading as the reference value. The display will now show readings relative to the stored reference value. That is, display = reading - stored value. Press the button momentarily to toggle to the relative zero mode. The annunciator turns on. The meter also enters manual ranging mode where available. The annunciator turns off. Display Backlight (Model 065 & 062 only) Press the SELECT button for 1 second or more to toggle the display backlight on and off. Auto Power Off (APO) When the meter is on, the Auto Power Off (APO) feature will switch the meter to sleep mode automatically after approximately 30 minutes of neither slide-switch nor push button operations to extend battery life. To wake up the meter from APO, press any push-button momentarily or set the slide-switch to the OFF position and then slide back on again. Always set the slide-switch to the OFF position manually when the meter is not in use. 5) MAINTENANCE WARNING To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input jacks and turn OFF the meter before opening the case. Do not operate with open case. Trouble Shooting If the instrument fails to operate, check batteries and test leads etc., and replace as necessary. Double check operating procedure as described in this user s manual If the instrument voltage-resistance input terminal has subjected to high voltage transient (caused by lightning or switching surge to the system) by accident or abnormal conditions of operation, the series fusible resistors will be blown off (become high impedance) like fuses to protect the user and the instrument. Most measuring

10 functions through this terminal will then be open circuit. The series fusible resistors and the spark gaps should then be replaced by qualified technician. Refer to the LIMITED WARRANTY section for obtaining warranty or repairing service. Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. If the meter is not to be used for periods of longer than 60 days, remove the batteries and store them separately Battery replacement The meter uses standard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03) alkaline battery X 2. Loosen the 2 captive screws from the battery cover case. Lift the battery cover case. Replace the batteries. Replace battery cover case. Re-fasten the screws.

11 6) SPECIFICATIONS Display : 3-3/4 digits 4000 counts LCD display(s) Update Rate : 3 per second nominal Polarity : Automatic Low Battery : Below approx. 2.4V Operating Temperature : 0 o C to 40 o C Relative Humidity : Maximum relative humidity 80% for temperature up to 31 o C decreasing linearly to 50% relative humidity at 40 o C Altitude : Operating below 2000m Storage Temperature : -20 o C to 60 o C, < 80% R.H. (with battery removed) Temperature Coefficient : nominal 0.15 x (specified accuracy)/ o C @(0 o C -18 o C or 28 o C -40 o C), or otherwise specified Sensing : Average sensing for Models 061 & 063; True RMS for Models 062 & 065 Safety : Meets IEC61010-1 2nd Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed., CAN/CSA C22.2 No. 61010.1-0.92, IEC61010-2-032, EN61010-2-032 & UL61010B-2-032 and CAN/CSA C22.2 No. 61010-2-032-04: Category III 600 Volts ac & dc. Transient protection : 6.5kV (1.2/50 s surge) for all models Pollution degree : 2 E.M.C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) In an RF field of 3V/m: Capacitance function is not specified Other function ranges: Total Accuracy = Specified Accuracy + 50igits Performance above 3V/m is not specified Overload Protections : Clamp-on jaws : DC/AC 400A rms continuous + & COM terminals (all functions) : 600VDC/VAC rms Power Supply : standard 1.5V AAA Size (NEDA 24G or IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03) alkaline battery X 2 Power Consumption : 11mA typical for ACA/DCA and 2.9mA typical for other functions APO Timing : Idle for 30 minutes APO Consumption : typical 10 A for Model 061 & 063 and 190 A for Model 062 & 065 Dimension : L188mm X W63mm X H40mm Weight : 218 gm approx Jaw opening & Conductor diameter : 30mm max

12 Accessories : Test lead pair, batteries installed, user's manual, soft carrying pouch, & BKP60 banana plug type-k thermocouple (model 063 & 065 only) Optional accessories : BKB32 banana plug to type-k socket plug adaptor (model 063 & 065 only) Electrical Specifications Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23 o C ± 5 o C & less than 75% R.H. True RMS Model 062 & 065 ACV & ACA clamp-on accuracies are specified from 5% to 100% of range or otherwise specified. Maximum Crest Factor are as specified below, and with frequency spectrums, besides fundamentals, fall within the meter specified AC bandwidth for non-sinusoidal waveforms. Fundamentals are specified at 50Hz and 60Hz. DC Voltage RANGE Accuracy 400.0 mv 0.3% + 3d 4.000V, 40.00V, 400.0V 0.5% + 3d 600V 1.0% + 4d Input Impedance : 10M, 30pF nominal (1000M for 400.0mV range) AC Voltage RANGE 50Hz ~ 60Hz 4.000V, 40.00V, 400.0V 60Hz ~ 500Hz 4.000V, 40.00V, 400.0V 50Hz ~ 500Hz 600V Input Impedance: 10M, 30pF nominal True RMS Model 062 & 065 Crest Factor: < 2 : 1 at full scale & < 4 : 1 at half scale Accuracy 1.0% + 4d 1.5% + 4d 2.0% + 4d

Ohms RANGE Accuracy 400.0 0.8% + 6d 4.000k, 40.00k, 400.0k 0.6% + 4d 4.000M 1.0% + 4d 40.00M 2.0% + 4d Open Circuit Voltage : 0.4VDC typical 13 Audible Continuity Tester Open Circuit Voltage: 0.4VDC typical Range: 400.0 ; Accuracy: 1.5% + 8d Audible threshold: between 10 and 120. Diode Tester Open Circuit Voltage : < 1.6 VDC Typical Test Current : 0.4mA Typical Capacitance RANGE 1) Accuracy 2) 3) 500.0nF, 5.000 F, 50.00 F, 500.0 F, 3.5% + 6d 3000 F 1) Additional 50.00nF range accuracy is not specified 2) Accuracies with film capacitor or better 3) Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4V DCA Current (Clamp-on) RANGE Accuracy 1) 2) 400.0A 0A ~ 50.0A 1.0% + 4d 50.0A ~ 200.0A 1.5% + 5d 200.0A ~ 300.0A 2.0% + 5d 300.0A ~ 400.0A 2.5% + 5d 1) Induced error from adjacent current-carrying conductor: < 0.01A/A 2) Relative Zero mode is applied to offset the non-zero residual readings, if any

ACA Current (Clamp-on) RANGE Accuracy 1) 400.0A 40Hz ~ 60Hz @ 0 ~ 50A 1.0% + 6d 60Hz ~ 400Hz @ 0 ~ 50A 1.5% + 5d 40Hz ~ 60Hz @ 50A ~ 200A 1.5% + 5d 60Hz ~ 200Hz @ 50A ~ 200A 2.0% + 5d 40Hz ~ 60Hz @ 200A ~ 300A 2.0% + 5d 40Hz ~ 60Hz @ 300A ~ 400A 2.5% + 5d 1) Induced error from adjacent current-carrying conductor: < 0.01A/A True RMS Model 062 & 065 Crest Factor: < 1.8 : 1 at full scale & < 3.6 : 1 at half scale 14 Hz Frequency Function Sensitivity (Sine wave) Range 400.0mV 350mV 10Hz ~ 1kHz 4.000V 3.2V 5Hz ~ 20kHz 40.00V 25V 5Hz ~ 100kHz 400.0V 100V 5Hz ~ 100kHz 600V 410V 5Hz ~ 5kHz DCA/ACA Unspecified Display counts: 5000 Maximum resolution: 0.001Hz Accuracy: 0.5%+4d Type-K Temperature (Model 063 & 065 only) RANGE Accuracy -20 o C ~ 300 o C 2.0% + 3d 300 o C ~ 537 o C 3.0% + 3d -4 o F ~ 572 o F 2.0% + 6d 572 o F ~ 1000 o F 3.0% + 6d Type-K thermocouple range & accuracy not included

LIMITED WARRANTY BRYMEN warrants to the original product purchaser that each product it manufactures will be free from defects in material and workmanship under normal use and service within a period of one year from the date of purchase. BRYMEN's warranty does not apply to accessories, fuses, fusible resistors, spark gaps, batteries or any product which, in BRYMEN's opinion, has been misused, altered, neglected, or damaged by accident or abnormal conditions of operation or handling. To obtain warranty service, contact your nearest BRYMEN authorized agent or send the product, with proof of purchase and description of the difficulty, postage and insurance prepaid, to BRYMEN TECHNOLOGY CORPORATION. BRYMEN assumes no risk for damage in transit. BRYMEN will, at its option, repair or replace the defective product free of charge. However, if BRYMEN determines that the failure was caused by misused, altered, neglected, or damaged by accident or abnormal conditions of operation or handling, you will be billed for the repair. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE. BRYMEN WILL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES. BRYMEN TECHNOLOGY CORPORATION TEL:+886 2 2226 3396 FAX:+886 2 2225 0025 http://www.brymen.com PRINTED ON RECYCLABLE PAPER, PLEASE RECYCLE COPYRIGHT MMX Btc, ALL RIGHTS RESERVED P/N: 7M1C-1081-0001 PRINTED IN TAIWAN