LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

Similar documents
Low Voltage AIRGUARD. A proven, rugged product for harsh environments

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

CIR (Crush & Impact Resistant) VFD Power Cable

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

14 AWG 2 AWG: 600 Volt

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

DLO Flexible Power Cable

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

GEXOL WORLD CLASS OIL & GAS CABLES

METAL CLAD WIRING SYSTEM

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Instrumentation Cables

Top Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

5-35kV 1/C TRXLE MV-90 POWER (wire shield) Medium Voltage Commercial & Industrial Cables

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

SIMpull THHN, it slips and slides - all with NoLube.

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

AIRGUARD CATALOG. Low and Medium Voltage Cable Products and Accessories

AIRGUARD CATALOG. Low and Medium Voltage Cable Products and Accessories

TIGER BRAND MINING CABLES

MEDIUM VOLTAGE

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

SKINTOP ÖLFLEX CLICK & VFD CLICK FLEX. Products for Variable Frequency Drive Applications. ake the right connection

THHN12STGN500 THHN 12 STR Green 500

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

THHN2BK2500 THHN 2 STR Black 2500

5-35kV 1/C TRXLE MV-90 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

MV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations

Addison Medium Voltage Cables

A. Product Description: Stranded conductor insulated wire.

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

Medium Voltage Power Cables

Conductors and Raceway Design

IMSA TRAFFIC SIGNAL CABLE

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

SUPERIOR MARINE CABLE SOLUTIONS

5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery

Airport Cables & Connectors

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

Underground System Design TADP 547

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications

Detailed Specifications & Technical Data

Canadian OSP Copper I-1. Table of Contents

Field Instrument Cable. Electrical Noise

Ground Clamps Cable Tray

High Performance Wire and Cable

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

American Electrical Institute

Kerman & Kavian Cable Industries ( KCI )

Heat-Shrinkable Tubing

High Voltage Cables Prysmian Group

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

Cable Solutions for Servo and Variable Frequency Drives (VFD)

VSD cables in. Working with. industrial & automation applications

Article 250 Grounding & Bonding

3M Electrical Markets Division 3M Cold Shrink Silicone Rubber Splices QS-III. Easy Installation. High reliability.

Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use

The STrongeST Link to your SucceSS... From ViSion to FiniShed ProducT

BX /2 Solid Ac/BX Aluminum Cable

QSLVM2500 QSLV-M Cold Shrink Insulator

Wire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Servo Cable Selection

Wisconsin Contractors Institute Continuing Education

Industrial Automation & Control Cables

CUSTOM DESIGN COAXIAL CABLES BY SICAB

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

SPEC 44. Wire and cable

Nexans Industrial Solutions PRODUCT CATALOG

ABOUT US ABOUT US 1 CRANE CABLES

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

For tough, seaworthy wire

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

Armoured Instrumentation Cables to BS6883

Detailed Specifications & Technical Data

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Industrial Data Solutions Industrial Ethernet Cables Category 5e DataTuff Twisted Pair Cables Heavy Duty Sunlight- and Oil-Resistant Jackets

Transcription:

ife? No S n K P r o ble m! No? aw a proven, rugged product for harsh environments No LV AIRGUARD

LV AIRGUARD Low Voltage Cables for Harsh Environments FEATURES - No Knife? No Saw? No Problem! installation makes terminating & splicing safer for electricians, and it greatly reduces the chances of damage to the conductors. - LV AIRGUARD provides users the ease of installation of a tray cable - Superior crush and impact resistance as compared to MC-HL cables when tested in accordance with UL-2225 -Smaller minimum bending radius as compared to metal clad cables. - Prysmian s patented Polymeric AIRBAG armor eliminates the concern of kinking or breaking of corrugated aluminum armor during installation or subsequent bending in service that is often associated with Type MC-HL cables - Reduced installation costs due to increased flexibility, ease of pulling, faster and safer cable preparation, - Use of less costly cable glands with significantly reduced installation time Low Voltage AIRGUARD cables are primarily designed for power, control, signal, and instrumentation applications in the harsh environments found in the heavy industrial and offshore markets. LV AIRGUARD has been designed to reduce installation costs in the field while improving the overall cable performance as compared to Type MC and MC-HL alternatives, which can often be costly, time consuming, and difficult to install. LV AIRGUARD is rated for installations in cable tray for exposed runs (Type TC-ER), conduit, and direct burial. It exceeds the stringent crush and impact resistance of UL 2225 for MC-HL cables and is permitted for use in Class I Division 1 and Zone 1 hazardous locations (TC-ER- HL) in accordance with National Electrical Code (2014) Sections 501.10(A)(2)(3) and 505.15(B)(i). Prysmian s patented AIRGUARD design affords far greater protection against water ingress and chemical attack than traditional MC armored cables. It also provides users the ease of installation of a tray cable while providing better mechanical and environmental protection than traditional metal clad cables. For 15 years, Medium Voltage AIRGUARD has been proven to outperform Metal Clad cables with better mechanical, chemical and installation performance. Now Prysmian s R&D group has extended that capability to our low voltage cables by designing LV AIRGUARD to solve the problems seen in the field. - AIRBAG layer provides superior protection from the ingress of harmful fluids, hydrocarbon and chemicals - Rated for installation in cable tray, for exposed runs (Type TC-ER), conduit, duct, direct burial, and aerial applications in Class I Division 2, Zone 2, and unclassified locations. - Permitted for use in Class I Division 1 and Zone 1 hazardous locations (Type TC-ER-HL) in accordance with National Electrical Code (2014) Sections 501.10(A)(2)(3) & 505.15(B)(i) - Rated for -40C/ -35C cold bend/ cold impact per CSA 22.2 No. 03 SPECIFICATIONS - ASTM B3 & ASTM B8 - UL 44 (XHHW-2) - ICEA S-95-658 (NEMA WC 70) - IEEE 1202 (Flame Retardant) - ICEA S-73-532 (NEMA WC57) - UL 1277 (TC-ER) - ICEA S-82-552 (NEMA WC55) - UL 2225 (TC-ER-HL) - MSHA LV AIRGUARD 21

Prysmian Group s LV AIRGUARD Low installation cost while improving the overall cable performance in harsh environments! Strippability No Knife!? No Saw? No Problem! The ability to strip a cable quickly without damaging the phase conductors is critical in reducing installation cost. The combination of AIRGUARD S unique design and strategically placed rip cords allows AIRGUARD to be stripped up to two or three times faster than Metal Clad cables without the worry of nicked or damaged phase conductors. LV AIRGUARD cables do not require the use of a saw (as in the case of CCW cables) which results in increased personnel safety and reduces the potential for damage to the underlying core. Outer Sheath AIRBAG Ground Wires Fillers Extruded Filler Belt EMI Shield Rip Cords Glands Prysmian s BiCon, (formally BICC), accessories group has developed a gland that allows for simple termination of LV AIRGUARD cable while grounding the sheath for both VFD applications and personal protection. Chemical Resistance Heavy Industrial plants require cable that will stand up to corrosive chemicals and hydrocarbons. Whether installing in a direct burial application, in tray, or in the air, LV AIRGUARD s proprietary Polymeric layer provides the best protection in the market for the broadest range of chemicals. Mechanical Resistance AIRGUARD is known for its Mechanical Strength. When Prysmian s R&D engineers were designing Prysmian s new LV AIRGUARD design it was imperative that the traditional toughness of the prior MV designs be passed on to the LV AIRGUARD design In crush tests Prysmian s LV AIRGUARD design is stronger than Metallic Armored Cables. Flame Not propagating a fire is a critical design of any cable for the industrial market. LV AIRGUARD passes all the industry standard flame tests, including IEEE 1202, FT-4 and IEEE 210,000 BTU flame test. VFD LV AIRGUARD Low Voltage VFD cables are designed with three symmetrically placed ground wires and an aluminum or copper sheath to contain the generation of high frequency electromagnetic interference (EMI) imposed on the cable when installed in a circuit containing a Variable Frequency Drive. VFD designs up to 2kV are also available Product Range LV AIRGUARD is available in 600V Power, Control & Instrumentation, from #16 AWG to 1000 kcmil. Standard stocked items include instrumentation cables, control cables to 37/C, and power cables to 3/C 750 kcmil. 32

LV AIRGUARD POWER CABLES Low Voltage 3/C & 4/C 600 Volt Power Cable 3/C Outer Sheath AIRBAG Ground Wires Fillers Extruded Filler Belt Mylar Tape Rip Cords Description 3 Prysmian s Low Voltage AIRGUARD Power Cables are primarily designed for applications in the harsh environments found in the heavy industrial and offshore markets. Its rugged polymeric AIRBAG armor and chemical barrier protection package makes it the ideal cable choice for tough harsh environmental conditions. AIRGUARD provides the solution to the deficiencies often encountered with MC-HL cables including armor breakage encountered during installation and in applications requiring recurring bending after installation, as well as poor performance in areas of high vibration (e.g. motor connections). It also provides a safer and lower installed cost alternative to MC-HL cables due to faster, No Knife/ No Saw cable preparation and substantially reduced cost of cable glands. Specifications ASTM B3 & ASTM B8 ICEA S-82-658 (NEMA WC70) UL 44 (XHHW-2) 600V IEEE 1202/FT-4 UL 1277 NEC Article 336.10(7) Class B Soft Drawn Concentric Lay Stranded Bare Copper Power Cable Rating XHHW-2 Multiple Sunlight Resistant Oil Resistant Flame Retardant TC-ER Exposed Run Rating UL 2225 TC-ER- HL Class I Division 1 NEC Article 501.10(A)(2)(3) Hazardous Locations NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1 Hazardous Locations CSA 22.2 No. 03 MSHA -40 o C/ -35 o C Cold Bend/ Cold Impact Mine Safety & Health Administration Design Parameters CONDUCTOR: Class B stranded bare, soft drawn copper circuit conductors INSULATION: Heat and moisture resistant cross-linked polyethylene (XLPE) meeting the requirements of UL-44 for Type XHHW-2 conductors FILLERS: Extruded filler belt GROUND WIRES: Class B stranded bare, soft drawn copper ground conductors OUTER SHEATH: Heat, moisture, hydrocarbon, and sunlight resistant thermoplastic Installation In Cable Tray Isolated in Air Dry Locations With Messenger Conduit Underground Duct Wet Locations Industrial *Used where CCW cables are used in Class 1 Div 2 areas. LV AIRGUARD 4/C

No Knife? No Saw? POWER Product Number Number and Circuit Conductor Size Insulation Thickness Number of Grounding Conductor Ground Wires Size Conductor Diameter Insulation (OD) Cable (OD ) Nominal Cable Weight Minimum Bending Radius Ampacity (Amps) Gland, Explosion Proof, Class 1 Division 1, Barrier Type mils # AWG inches inches inches lbs/mft inches 90 C 600 Volt LV AIRGUARD Power Cables 394075 3/C #14 AWG 30 3 18 AWG 0.071 0.135 0.620 227 2.5 25 424UB03 394040 4/C #14 AWG 30 3 14 AWG 0.71 0.135 0.660 248 2.7 20 424UB03 394076 3/C #12 AWG 30 3 16 AWG 0.089 0.153 0.660 273 2.7 30 424UB03 394042 4/c #12 AWG 30 1 12 AWG 0.089 0.153 0.705 304 2.9 24 424UB03 394077 3/C #10 AWG 30 3 14 AWG 0.113 0.177 0.715 344 2.9 40 424UB03 394044 4/C #10 AWG 30 1 10 AWG 0.113 0.177 0.765 390 3.1 32 424UB04 394078 3/C #8 AWG 45 3 14 AWG 0.142 0.238 0.860 508 3.5 55 424UB04 394079 3/C #6 AWG 45 3 12 AWG 0.176 0.274 0.980 655 4.0 75 424UB04 *394080 3/C #4 AWG 45 3 12 AWG 0.225 0.321 1.035 851 5.5 95 424UB15 *394081 3/C #2 AWG 45 3 10 AWG 0.83 0.379 1.215 1180 6.1 130 424UB15 *394082 3/C #1/0 AWG 55 3 10 AWG 0.360 0.476 1.435 1649 7.2 170 424UB06 *394083 3/C #2/0 AWG 55 3 10 AWG 0.402 0.518 1.530 1960 7.7 195 424UB06 PRODUCT NOTES: Per 2014 NEC TABLE 310.15(B)(16) (formerly Table 310.16) Allowable Ampacities of Insulated Rated Up to and Including 2000 Volts, 60 C Through 90 C (140 F Through 194 F), Not More ThanThree Current-Carrying in Raceway, Cable, or Earth (Directly Buried), Based on AmbientTemperature of 30 C (86 F) *Cables not marked -HL (per UL 2225, overall cable diameter must be 1.00 inch or less to be marked -HL ) will not kink. No Problem! 4

LV AIRGUARD POWER CABLES Low Voltage 600 Volt VFD Power Cable Outer Sheath AIRBAG Ground Wires Fillers Extruded Filler Belt EMI Shield Rip Cords Description Prysmian s Low Voltage AIRGUARD Power Cables are primarily designed for applications in the harsh environments found in the heavy industrial and offshore markets. Its rugged polymeric Airbag armor and chemical barrier protection package makes it the ideal cable choice for tough harsh environmental conditions. AIRGUARD provides the solution to the deficiencies often encountered with MC-HL cables including armor breakage encountered during installation and in applications requiring recurring bending after installation, as well as poor performance in areas of high vibration (e.g. motor connections). It also provides a safer and lower installed cost alternative to MC-HL cables due to faster, No Knife/ No Saw cable preparation, and substantially reduced cost of cable glands. Specifications ASTM B3 & ASTM B8 ICEA S-82-558(NEMA WC70) UL 44 (XHHW-2) 600V UL 1202/FT-4 UL 1277 NEC Article 336.10(7) Class B Soft Drawn Concentric Lay Stranded Bare Copper Power Cable Rating XHHW-2 Multiple Sunlight Resistant Oil Resistant Flame Retardant TC-ER Exposed Run Rating UL 2225 TC-ER- HL Class I Division 1 NEC Article 501.10(A)(2)(3) Hazardous Locations Design Parameters CONDUCTOR: Class B stranded bare, soft drawn copper circuit conductors INSULATION: Heat and moisture resistant cross-linked polyethylene (XLPE) meeting the requirements of UL-44 for Type XHHW-2 conductors FILLERS: Extruded filler belt GROUND WIRES: Class B stranded bare, soft drawn copper ground conductors (3) EMI SHIELD: Metallic tape provides 100% coverage POLYMERIC ARMOR/ENVIROMENTAL BARRIER: Foamed polymeric AIRBAG layer affords superior mechanical & environmental protection of the cable core OUTER SHEATH: Heat, moisture, hydrocarbon, and sunlight resistant thermoplastic Installation In Cable Tray Isolated in Air Dry Locations With Messenger Conduit Underground Duct Wet Locations Industrial *Used where CCW cables are used in Class 1 Div 2 areas. 5 NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1 Hazardous Locations CSA 22.2 No. 03 MSHA -40 o C/ -35 o C Cold Bend/ Cold Impact Mine Safety & Health Administration LV AIRGUARD

No Knife? No Saw? VFD Product Number Number and Circuit Conductor Size Insulation Thickness Number of Grounding Conductor Ground Wires Size Conductor Diameter Insulation (OD) Cable (OD ) Nominal Cable Weight Minimum Bending Radius Ampacity (Amps) Gland, Explosion Proof, Class 1 Division 1, Barrier Type mils # AWG inches inches inches lbs/mft inches 90 C 600 Volt LV AIRGUARD VFD Power Cables 394039 3/C #14 AWG 30 3 18 AWG 0.071 0.135 0.630 247 7.5 15 424UB03 394041 3/C #12 AWG 30 3 16AWG 0.089 0.153 0.670 296 8.1 20 424UB03 394043 3/C #10 AWG 30 3 14 AWG 0.113 0.177 0.725 364 8.7 30 424UB03 394045 3/c #8 AWG 45 3 14 AWG 0.142 0.238 0.905 544 10.9 55 424UB04 394046 3/C #6 AWG 45 3 12 AWG 0.178 0.274 0.990 696 11.9 75 424UB04 394047 3/C #4 AWG 45 3 12 AWG 0.225 0.321 1.095 898 13.2 95 424UB15 *394048 3/C #2 AWG 45 3 10 AWG 0.283 0.379 1.225 1236 14.7 130 424UB15 *394049 3/C #1/0 MCM 55 3 10 AWG 0.360 0.476 1.445 1719 17.3 170 424UB06 *394050 3/C #2/0 MCM 55 3 10 AWG 0.402 0.518 1.540 2017 18.5 195 424UB06 *Q0B580A 3/C #4/0 MCM 55 3 8 AWG 0.512 0.63 1.83 3450 13 260 424UB07 *Q0C580A 3/C #250 MCM 65 3 8 AWG 0.558 0.70 1.98 4024 14 290 424UB07 *Q0D580A 3/C #350 MCM 65 3 7 AWG 0.661 0.80 2.22 5312 16 350 424UB08 *QXZ308A 3/C #400 MCM 65 3 7 AWG 0.706 0.85 2.41 6008 17 380 424UB09 * Q0E580A 3/C #500 MCM 65 3 6 AWG 0.789 0.93 2.53 7194 18 430 424UB09 306451A 3/C #750 MCM 80 3 5 AWG 0.973 1.09 3.02 10518 22 535 -------- PRODUCT NOTES: Per 2014 NEC TABLE 310.15(B)(16) (formerly Table 310.16) Allowable Ampacities of Insulated Rated Up to and Including 2000 Volts, 60 C Through 90 C (140 F Through 194 F), Not More Than Three Current-Carrying *Cables not marked "-HL" (per UL 2225, overall cable diameter must be 1.00 inch or less to be marked "-HL") will not kink. No Problem! 6

LV AIRGUARD CONTROL CABLE Low Voltage 600 Volt Control Cable Outer Sheath Insulation AirBag Extruded Filler Belt Rip Cords Description Prysmian s Low Voltage AIRGUARD Control Cables are primarily designed for applications in the harsh environments found in the heavy industrial and offshore markets. Its rugged polymeric AIRBAG armor and chemical barrier protection package makes it the ideal cable choice for tough installation and environmental conditions. AIRGUARD provides the solution to the deficiencies often encountered with MC-HL cables including armor breakage encountered during installation and in applications requiring recurring bending after installation, as well as poor performance in areas of high vibration (e.g. motor connections). It also provides a safer and lower installed cost alternative to MC-HL cables due to faster, No Knife/ No Saw cable preparation, and substantially reduced cost of cable glands. Specifications ASTM B3 & ASTM B8 ICEA S-82-532 (NEMA WC57) UL 44 (XHHW-2) 600V UL 1202/FT-4 UL 1277 NEC Article 336.10(7) Class B Soft Drawn Concentric Lay Stranded Bare Copper Control Cable Rating XHHW-2 Multiple Sunlight Resistant Oil Resistant Flame Retardant TC-ER Exposed Run Rating UL 2225 TC-ER- HL Class I Division 1 NEC Article 501.10(A)(2)(3) Hazardous Locations Design Parameters CONDUCTOR: Class B stranded bare, soft drawn copper circuit conductors INSULATION: 90 o C Heat and moisture resistant cross-linked polyethylene (XLPE) meeting the requirements of UL-44 for Type XHHW-2 conductors for wet or dry locations FILLERS: Extruded filler belt POLYMERIC ARMOR/ENVIROMENTAL BARRIER: Foamed polymeric AIRBAG layer affords superior mechanical and environmental protection of the cable core OUTER SHEATH: Heat, moisture, hydrocarbon, and sunlight resistant thermoplastic Installation In Cable Tray Isolated in Air Dry Locations With Messenger Conduit Underground Duct Wet Locations Industrial *Used where CCW cables are used in Class 1 Div 2 areas. 7 NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1 Hazardous Locations CSA 22.2 No. 03 MSHA -40 o C/ -35 o C Cold Bend/ Cold Impact Mine Safety & Health Administration LV AIRGUARD

No Knife? No Saw? CONTROL Product Number Number and Circuit Conductor Size Insulation Thickness Conductor Diameter Insulation Diameter Cable Diameter Nominal Cable Weight Minimum Bending Radius Ampacity (Amps) Gland, Explosion Proof, Class 1 Division 1, Barrier Type 600 Volt AIRGUARD Control Cables mils inches inches inches lbs/mft inches 90 C 394061 5/C #14 AWG 30 0.071 0.135 0.700 278 2.8 15 424UB03 394067 5/C #12 AWG 30 0.089 0.153 0.750 337 3.0 20 424UB03 394073 5/C #10 AWG 30 0.113 0.177 0.820 429 3.4 30 424UB04 394062 7/C #14 AWG 30 0.071 0.135 0.740 327 3.0 15 424UB03 394068 7/C #12 AWG 30 0.089 0.153 0.800 404 3.2 20 424UB04 394074 7/C #10 AWG 30 0.113 0.177 0.915 564 3.7 28 424UB04 394063 9/C #14 AWG 30 0.071 0.135 0.830 399 3.4 17.5 424UB04 394069 9/C #12 AWG 30 0.089 0.153 0.940 538 3.8 21 424UB04 394064 12/C #14 AWG 30 0.071 0.135 0.950 519 3.8 12.5 424UB04 *394070 12/C #12 AWG 30 0.089 0.153 1.030 650 5.2 15 424UB04 *394065 19/C #14 AWG 30 0.071 0.135 1.070 693 5.4 12.5 424UB15 *394071 19/C #12 AWG 30 0.089 0.153 1.165 885 5.9 15 424UB15 *394066 37/C #14 AWG 30 0.071 0.135 1.355 1137 6.8 10 424UB06 *394072 37/C #12 AWG 30 0.089 0.153 1.490 1495 7.5 12 424UB06 PRODUCT NOTES: Conductor count includes insulated grounding conductor colored green. *Cables not marked -HL (per UL 2225, overall cable diameter must be 1.00 inch or less to be marked -HL ) will not kink. No Problem! 8

LV AIRGUARD INSTRUMENTATION CABLE Low Voltage 600 Volt (IS/OS) Instrumentation Cable Outer Sheath AIRBAG Mylar Tape Extruded Filler Belt Extruded Filler Belt Rip Cords Shield & Drain Wires (In & Out) Description Prysmian s Low Voltage AIRGUARD Instrumenation Cables are primarily designed for applications in the harsh environments found in the heavy industrial and offshore markets. Its rugged polymeric Airbag armor and chemical barrier protection package makes it the ideal cable choice for tough harsh environmental conditions. AIRGUARD provides the solution to the deficiencies often encountered with MC-HL cables including armor breakage encountered during installation and in applications requiring recurring bending after installation, as well as poor performance in areas of high vibration (e.g. motor connections). It also provides a safer and lower installed cost alternative to MC-HL cables due to faster, No Knife/ No Saw cable preparation, and substantially reduced cost of cable glands. Specifications ASTM B3 & ASTM B8 ICEA S-82-552 (NEMA WC55) UL 44 (XHHW-2) 600V ieee 1202/FT-4 UL 1277 NEC Article 336.10(7) Class B Soft Drawn Concentric Lay Stranded Bare Copper Instrumentation Cable Rating XHHW-2 Multiple Sunlight Resistant Oil Resistant Flame Retardant TC-ER Exposed Run Rating UL 2225 TC-ER- HL Class I Division 1 NEC Article 501.10(A)(2)(3) Hazardous Locations NEC Article 505.15(B)(1)(i) TC-ER-HL Class I Zone 1 Hazardous Locations CSA 22.2 No. 03-40 o C/ -35 o C Cold Bend/ Cold Impact Design Parameters CONDUCTOR: Class B stranded bare, soft drawn copper circuit conductors INSULATION: Heat and moisture resistant cross-linked polyethylene (XLPE) meeting the requirements of UL-44 for Type XHHW-2 conductors FILLERS: Flame resistant non-hygroscopic fillers (as needed) DRAIN WIRES: Class B stranded bare, soft drawn tinned copper drain wire ASSEMBLY: An aluminum/ polyester tape with drain wire, 100% coverage, is applied over the twisted pairs or triads and the cabled core. Single pair or traid constructions have only the overall shield and drain wire. POLYMERIC ARMOR/ENVIROMENTAL BARRIER: Foamed polymeric AIRBAG layer affords superior mechanical & environmental protection of the cable core OUTER SHEATH: Heat, moisture, hydrocarbon, and sunlight resistant thermoplastic Installation In Cable Tray Isolated in Air Dry Locations With Messenger Conduit Underground Duct Wet Locations Industrial *Used where CCW cables are used in Class 1 Div 2 areas. 9 LV AIRGUARD

No Knife? No Saw? INSTRUMENTATION Product Number Number and Circuit Conductor Size Insulation Thickness Conductor Diameter Insulation (OD) Cable (OD ) Nominal Cable Weight Minimum Bending Radius Ampacity (Amps) Gland, Explosion Proof, Class 1 Division 1, Barrier Type mils inches inches inches lbs/mft inches 90 C 600 Volt LV AIRGUARD IS/OS Cables 394051 1/PR #16 AWG 30 0.059 0.123 0.575 175 6.9 10.0 424UB02 394052 1/TR #16 AWG 30 0.059 0.123 0.595 197 7.2 10.0 424UB02 394053 2/PR#16 AWG 30 0.059 0.123 0.770 311 9.3 10.0 424UB04 394054 4/PR #16 AWG 30 0.059 0.123 0.850 411 10.2 10.0 424UB04 394059 4/TR #16 AWG 30 0.059 0.123 1.050 540 12.6 9.0 424UB15 394055 8/PR #16 AWG 30 0.059 0.123 1.090 664 13.1 9.0 424UB15 *394056 12/PR #16 AWG 30 0.059 0.123 1.275 901 15.3 8.1 424UB06 *394060 12/TR #16 AWG 30 0.059 0.123 1.545 1104 18.6 7.2 424UB06 *394057 24/PR #16 AWG 30 0.059 0.123 1.685 1506 20.3 6.3 424UB07 *394058 36/PR #16 AWG 30 0.059 0.123 1.970 2201 23.7 6.3 424UB07 PRODUCT NOTES: Per 2014 NEC TABLE 310.15(B)(16) (formerly Table 310.16) Allowable Ampacities of Insulated Rated Up to and Including 2000 Volts, 60 C Through 90 C (140 F Through 194 F), Not More Than Three Current-Carrying *Cables not marked "-HL" (per UL 2225, overall cable diameter must be 1.00 inch or less to be marked "-HL") will not kink. No Problem! 10

For more information: na.prysmiangroup.com Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy and information as a primary driver in the development of communities. With this in mind, we provide major global organizations in many industries with best-inclass cable solutions, based on state-of-the-art technology. Through two renowned commercial brands Prysmian and Draka based in almost 100 countries, we re constantly close to our customers, enabling them to further develop the world s energy & telecom infrastructures, and achieve sustainable, profitable growth. In our energy business, we design, produce, distribute, install cables and systems for the transmission/distribution of power at low, medium, high and extra-high voltage. In telecoms, the Group is a leading manufacturer of all types of copper and fiber cables, systems and accessories covering voice, video and data transmission. Drawing on over 130 years experience and continuously investing in R&D, we apply excellence, understanding and integrity to everything we do, meeting and exceeding the precise needs of our customers across all continents, at the same time shaping the evolution of our industry. United States - 700 Industrial Drive Lexington, SC 29072 +1-800-845-8507 website: na.prysmiangroup.com Canada - 137 Commerce Drive R. R #3 Johnstown, Ontario K0E1T1 1-800-845-8507 (US) 1-800-263-4405 (West-CAN) 1-800-361-1418 (East-CAN)