CADMIUM Telluride (CdTe) and Cadmium Zinc Telluride

Similar documents
Fabrication and Test of Pixelated CZT Detectors with Different Pixel Pitches and Thicknesses

Test of CZT Detectors with Different Pixel Pitches and Thicknesses

Charge Sharing Effect on 600 µm Pitch Pixelated CZT Detector for Imaging Applications *

Improvement of the CdTe Diode Detectors using a Guard-ring Electrode

Author(s) Osamu; Nakamura, Tatsuya; Katagiri,

Title detector with operating temperature.

Improvement of Energy Resolutions for Planar TlBr Detectors Using the Digital Pulse Processing Method

Properties of Irradiated CdTe Detectors O. Korchak M. Carna M. Havranek M. Marcisovsky L. Tomasek V. Vrba

236 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 59, NO. 1, FEBRUARY 2012

XRF Instrumentation. Introduction to spectrometer

Marten Bosma 1, Alex Fauler 2, Michael Fiederle 2 en Jan Visser Nikhef, Amsterdam, The Netherlands 2. FMF, Freiburg, Germany

SPECTROMETRIC DETECTION PROBE Model 310. Operator's manual

The Influence of Edge Effects on the Detection Properties of Detector Grade Cadmium Telluride

Charge Loss Between Contacts Of CdZnTe Pixel Detectors


MEASUREMENT AND MODELING OF BLOCKING CONTACTS FOR CADMIUM TELLURIDE GAMMA RAY DETECTORS

Characterization of SC CVD diamond detectors for heavy ions spectroscopy

High-Speed Scalable Silicon-MoS 2 P-N Heterojunction Photodetectors

Possibilities for Thick, Simple- Structure Silicon X-Ray Detectors Operated by Peltier Cooling

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT

Silicon Carbide Solid-State Photomultiplier for UV Light Detection

Simulation of High Resistivity (CMOS) Pixels

Role of guard rings in improving the performance of silicon detectors

Strip Detectors. Principal: Silicon strip detector. Ingrid--MariaGregor,SemiconductorsasParticleDetectors. metallization (Al) p +--strips

CZT imaging detectors for ProtoEXIST

Energy resolution and transport properties of CdTe-Timepix-Assemblies

Week 9: Chap.13 Other Semiconductor Material

Soft X-Ray Silicon Photodiodes with 100% Quantum Efficiency

Residual bulk image quantification and management for a full frame charge coupled device image sensor. Richard Crisp

Advances in microchannel plate detectors for UV/visible Astronomy

Digital Signal Processing for HPGe Detectors

Superconducting Transition-Edge Sensors and Superconducting Tunnel Junctions for Optical/UV Time-Energy Resolved Single-Photon Counters

How Does One Obtain Spectral/Imaging Information! "

arxiv: v1 [physics.ins-det] 2 Sep 2015

Silicon sensors for radiant signals. D.Sc. Mikko A. Juntunen

High Resolution Schottky CdTe diode for Hard X-ray and Gamma-ray Astronomy

Case Study: Custom CCD for X-ray Free Electron Laser Experiment

2015 JINST 10 C Interconnect and bonding techniques for pixelated X-ray and gamma-ray detectors

Design and Performance of a Pinned Photodiode CMOS Image Sensor Using Reverse Substrate Bias

Simulation and test of 3D silicon radiation detectors

Measurements With Irradiated 3D Silicon Strip Detectors

Development of Integration-Type Silicon-On-Insulator Monolithic Pixel. Detectors by Using a Float Zone Silicon

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

High Power RF MEMS Switch Technology

Author s Accepted Manuscript

K-edge subtraction X-ray imaging with a pixellated spectroscopic detector

Single Photon X-Ray Imaging with Si- and CdTe-Sensors

Fully depleted, thick, monolithic CMOS pixels with high quantum efficiency

Copyright -International Centre for Diffraction Data 2010 ISSN

Interpixel crosstalk in a 3D-integrated active pixel sensor for x-ray detection

Recent ETHZ-YEBES Developments in Low-Noise phemts for Cryogenic Amplifiers

Dynamic Range. Can I look at bright and faint things at the same time?

Fabrication of High-Speed Resonant Cavity Enhanced Schottky Photodiodes

Detectors for AXIS. Eric D. Miller Catherine Grant (MIT)

Production of HPDs for the LHCb RICH Detectors

64 Channel Flip-Chip Mounted Selectively Oxidized GaAs VCSEL Array

Caliste 64, an innovative CdTe hard X-ray micro-camera

Instruction manual and data sheet ipca h

Study of irradiated 3D detectors. University of Glasgow, Scotland. University of Glasgow, Scotland

Average energy lost per unit distance traveled by a fast moving charged particle is given by the Bethe-Bloch function

Performance of a-si:h Photodiode Technology-Based Advanced CMOS Active Pixel Sensor Imagers

Citation X-Ray Spectrometry (2011), 40(4): 2. Right final form at

Novel MPGD based Detectors of Single Photons for COMPASS RICH-1 Upgrade

Digital Signal Processing Methods for Pixelated 3-D Position Sensitive Room-Temperature Semiconductor Detectors

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Chapter 1. Introduction

NOT FOR DISTRIBUTION JINST_128P_1010 v2

Schottky Diode RF-Detector and Focused Ion Beam Post-Processing MURI Annual Review

Energy Measurements with a Si Surface Barrier Detector and a 5.5-MeV 241 Am α Source

Silicon Photomultiplier Evaluation Kit. Quick Start Guide. Eval Kit SiPM. KETEK GmbH. Hofer Str Munich Germany.

THIN FILM TRANSISTORS AND THIN FILM TRANSISTOR CIRCUITS

Tokyo University of Science, 2641 Yamazaki, Noda,Chiba , Japan b Departument of physics, Faculty of Science and Technology,

cividec DIAMOND DETECTORS & SYSTEMS FOR X-RAYS Instrumentation CIVIDEC Instrumentation GmbH Vienna The Netherlands +31 (0)


Gigahertz Ambipolar Frequency Multiplier Based on Cvd Graphene

Quality Assurance for the ATLAS Pixel Sensor

Tests of monolithic CMOS SOI pixel detector prototype INTPIX3 MOHAMMED IMRAN AHMED. Supervisors Dr. Henryk Palka (IFJ-PAN) Dr. Marek Idzik(AGH-UST)

High collection efficiency MCPs for photon counting detectors

- Datasheet - Features: Version 1.1. Cryogenic Low Pass Filter Unit Type KA-Fil 2a

THE USE OF CdTe DETECTORS FOR DENTAL X-RAY SPECTROMETRY

The superconducting microcalorimeters array for the X IFU instrument on board of Athena Luciano Gottardi

Single Sided and Double Sided Silicon MicroStrip Detector R&D

Digital Signal Processing Methods for Pixelated 3-D Position Sensitive Room-Temperature Semiconductor Detectors

Silicon Drift Detector. with On- Chip Ele ctronics for X-Ray Spectroscopy. KETEK GmbH Am Isarbach 30 D O berschleißheim GERMANY

Geiger-mode APDs (2)

Evaluation of large pixel CMOS image sensors for the Tomo-e Gozen wide field camera

Characteristics of the ALICE Silicon Drift Detector.

A cadmium-zinc-telluride crystal array spectrometer

Amptek Inc. Page 1 of 7

Interface Trap States in Organic Photodiodes. Supplementary Information

Vertical Nanowall Array Covered Silicon Solar Cells

ASTE. RECfr ED OCT COAIF- 980b76-- with Three-Dimensional Position 0 s Sensitivity. Coplanar=grid CdZnTe Detector. Engineering Division

Electronic Supplementary Information

ORTEC. Research Applications. Pulse-Height, Charge, or Energy Spectroscopy. Detectors. Processing Electronics

A Readout ASIC for CZT Detectors

Lecture 2. Part 2 (Semiconductor detectors =sensors + electronics) Segmented detectors with pn-junction. Strip/pixel detectors

Spectrally Selective Photocapacitance Modulation in Plasmonic Nanochannels for Infrared Imaging

MA4L Series. Silicon PIN Limiters RoHS Compliant. M/A-COM Products Rev. V12. Features. Chip Outline. Description. Applications

Detailed Characterisation of a New Large Area CCD Manufactured on High Resistivity Silicon

SPECTROMETRIC CHARACTERISTIC IMPROVEMENT OF CdTe DETECTORS*

Transcription:

Evaluation of 5 mm-thick CdTe Detectors from the Company Acrorad Alfred Garson III 1, Ira V. Jung 1, Jeremy Perkins 1, and Henric Krawczynski 1 arxiv:astro-ph/511577v1 18 Nov 25 Abstract Using 2 2.5 cm 3 Cadmium Telluride (CdTe) substrates from the company Acrorad, we have fabricated detectors with planar cathode contacts and 8 8 anode pixels. We investigate the I-V characteristics and energy resolution of the detectors for different contact materials and surface treatments. After biasing the detectors for a certain time, the dark currents increase dramatically. Our studies show that the time before breakdown decreases for higher detector temperatures and for higher applied bias voltages. We obtained the best results with a Pt cathode contact and In anode pixels when we heat the detector to 9 C for 3 minutes prior to depositing the In contacts. Flood-illuminating the detector with 662 kev X-rays, we measured the pulse length distribution and derived an electron mobility of 86 cm 2 V 1 s 1. We show that the energy resolution can be improved by correcting the anode signals for the depth of the primary interaction. Operated at a temperature of -4 C and a cathode bias voltage of V, the best pixels of the best detector achieved full width half maximum (FWHM) energy resolutions of 8 kev (6.4%) and 23 kev (3.4%) at 122 kev and 662 kev, respectively. Index Terms CdTe, CdTe detectors, contacting technology I. INTRODUCTION CADMIUM Telluride (CdTe) and Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field of hard X-ray astronomy. The Swift [1] satellite carries the Burst Alert Telescope (BAT) that uses CZT detectors. The International Gamma-Ray Astrophysics Laboratory (INTEGRAL) [2] includes the Imager on Board the Integral Satellite (IBIS) which is built with CdTe detectors. NASA s Beyond Einstein roadmap included two X-ray missions, Constellation-X [3] and the Black Hole Finder Probe (BHFP). CZT detectors will play an important role for both missions. The Energetic X-ray Imaging Survey Telescope (EXIST) [4] is a strong candidate for the BHFP and uses pixelated Si and.5 cm thick CZT detectors and the coded mask approach to cover the energy range from 5 kev to 6 kev. The Non-thermal Energy exploration Telescope (NeXT) [5] [6] mission proposed in Japan is a successor to the Suzaku mission and will utilize CdTe on two of its instruments. The Hard X-ray Imager (HXI) on board NeXT will cover the energy range from 8 to 8 kev using a Si CCD combined with a pixelated CdTe detector. NeXT will also carry the Soft-Gamma Detector (SGD), which uses CdTe for an extended energy range up to 1 MeV. The broad energy ranges of these missions 1 Washington University in St. Louis, 1 Brookings Drive, CB 115, St. Louis, Mo, 6313 A. Garson:agarson3@hbar.wustl.edu Manuscript received November 11, 25. requires either thick detectors or layers of thin detectors. In this presentation, we focus on 5 mm-thick CdTe detectors. While CdTe detectors show at room temperature a poorer performance than CZT detectors, CdTe might be an alternative to CZT in spaceborne applications where temperatures around -2 C can be achieved without the need for cryogenic cooling. Several groups tested relatively thin CdTe detectors (e.g. [7] [1]). We report here on results from evaluating.5 cm thick CdTe detectors. Using substrates from the company Acrorad [11], we deposited different cathode and anode contacts and measured the I-V characteristics, the energy resolutions, and the electron mobility. II. DETECTOR FABRICATION We purchased two uncontacted 2 2.5 cm 3 CdTe substrates from Acrorad. In the following, we refer to the two detectors as D1 and D2. The substrates were cleaned in DI water and methanol. Prior to contact deposition, the detectors were polished with three grades of abrasive paper followed by.3 and.5 µm alumina suspension. Optionally, the detectors were etched for 2 minutes in a solution of 5% Br in 95% methanol. We deposited planar cathode contacts and 8 8 anode pixels on the CdTe substrates with an electron beam evaporator. The 1.6 mm diameter pixels with 2.4 mm pixel pitch were deposited using a.3 mm brass foil shadow mask. The first detectors showed modest performances. We thus started to use a method similar to the one described by Takahashi et al. (1999), and heated D1 at 9 C (3 minutes) and D2 at 14 C (15 minutes) prior to the deposition of the anode contacts. The heating was performed in a 1 7 Torr vacuum with the anode side facing an Hg lamp, and a temperature sensor being attached to the backside of the detector. As discussed further below, the heat treatment markedly improved the energy resolution achieved with the detectors. We used the high-workfunction metals Au and Pt as cathode materials and the low-workfunction metal In as anode material. The high-workfunction Au and Pt metals are expected to form ohmic contacts on the p-type CdTe and the low-workfunction contacts blocking contacts. The heat treatment is thought to remove the Te-rich surface layer and to improve the contact properties of the CdTe In junctions [7]. We will refer to the two detectors as D1a-D1b and D2a-D2c, depending on which surface treatments and contact materials were used (see Table 1).

-1-2 -3-4 -45 5 D1a Continuous Voltage C -1V C -11V Room Temp -6V Room Temp -9V Room Temp -1V 2 4 6 8 1 12 14 16 18 Time [s] 1-1 -2-3 -4 D1b Continuous Voltage Room Temp V Room Temp -6V Room Temp -7V 2 4 6 8 1 12 Time [s] Fig. 1 BREAKDOWN BEHAVIOUR FOR D1A (ANODE DEPOSITION AFTER POLISHING). FROM LEFT TO RIGHT, THE MEASUREMENTS WERE TAKEN AT 2 C -1 V, 2 C -9 V, C -11 V, C -1 V, AND 2 C -6 A. I-V Characteristics V. III. RESULTS We measured the pixel-cathode dark current as a function of the cathode bias voltage for detector temperatures between 4 C and 2 C. Holding all pixels at ground potential, the currents were measured for three central pixels. After keeping the detectors biased at a certain voltage for some time, we observed the well known breakdown phenomenon: a dramatic increase of the dark current. We found that if the bias voltage was set to zero after a breakdown and then immediately returned to its previous value, the breakdown would occur after a shorter period of time. However, if the bias voltage remained at zero for several minutes and was then returned to its previous value, the breakdown time would be very similar to its original value. Figure 1 shows the current for the detector D1a at different temperatures and different bias voltages. It is evident that the time before breakdown decreases with increasing detector temperature and with more negative cathode bias voltages. Figure 2 shows a very similar breakdown behaviour for the same crystal, this time depositing the In pixels after polishing, etching, and heat treatment (detector D1b). As discussed further below, our heat treatment may have used temperatures too low to strongly suppress the breakdown behaviour. The I-V measurements showed a wide range of variation from detector to detector and from pixel to pixel. Figure 3 shows the dark current for the detector D1a as a function of bias voltage for various temperatures. All measurements were taken before breakdown occurred. It can be recognized that the I-V characteristics are non-linear. Figure 4 shows the measurements for three pixels on D1b; a large variation from pixel to pixel can be recognized. Figure 5 compares the results for D2a (Pt Fig. 2 BREAKDOWN BEHAVIOUR FOR DETECTOR D1B (ANODE DEPOSITION AFTER POLISHING, 2 MINUTES ETCHING AND HEAT TREATMENT AT 9 C FOR 3 MIN). IN THE CASE OF THE V BIAS, THE VOLTAGE WAS AUTOMATICALLY SHUT DOWN WHEN THE CURRENT REACHED NA. AFTER SOME WAITING TIME, IT WAS SET TO V AGAIN. ALL MEASUREMENTS WERE TAKEN AT ROOM TEMPERATURE. THE ANODES WERE KEPT AT GROUND POTENTIAL, AND THE CATHODE BIAS VOLTAGES WERE FROM LEFT TO RIGHT -7 V, -6 V, AND V. cathode) and D2b (Au cathode). The detector with Au cathode shows very high dark currents that compromise the detector s spectroscopic performance. B. Energy Resolution and Mobility Measurements The energy resolutions of the detectors were determined using a 662 kev X-ray source and cooling the detectors to 4 C. The same three pixels for which the I-V measurements were performed were also used for measuring the energy spectra. A cathode bias voltage of V was applied; at 4 C this voltage allowed us to operate the detectors without incurring breakdown. The pixels were held at ground and AC coupled to a fast Amptek 25 amplifier followed by a secondstage amplifier. The signals were sampled with a 5 MHz oscilloscope and the digitized pulses were send to a computer via Ethernet. High-frequency filtering was done offline. The amplifier noise was 5 kev at -4 C and was subtracted in quadrature from the measured resolutions. In most cases, the amplifier noise was negligible compared to the inherent detector resolution. A more detailed description of the measurement setup can be found in Krawczynski et al. (25) Owing to trapping of electrons and poor hole mobility, interactions occurring near the cathode produce larger anode signals than those that occur near the anodes. This depth of interaction (DOI) effect can be corrected by comparing the anode and cathode signals for each pulse. Figure 6 shows the anode vs. cathode pulse heights. Photopeak events are highlighted in blue. The original and corrected 122 kev and

2-2 -4-6 D1a - Pixel 1-8 Room Temp -1 C -2C -12-4C -16-14 -12-1 -8-6 -4-2 5-1 -2-3 -4-45 D2b - Pixel 1-8 -7-6 -4-3 -2-1 Gold C Gold -2C Gold -4C Pt C Pt -2C Pt -4C Fig. 3 THE I-V BEHAVIOUR AT VARIOUS TEMPERATURES FOR D1A (ANODE DEPOSITION AFTER POLISHING). FROM TOP TO BOTTOM, MEASUREMENTS WERE TAKEN AT -4 C, -2 C, C, AND 2 C. Fig. 5 COMPARISON OF I-V BEHAVIOUR FOR DETECTOR D2 WITH PT CATHODE (D2A) AND AU CATHODE (D2B). FROM TOP TO BOTTOM, MEASUREMENTS WERE TAKEN AT 4 C (D2A), -2 C (D2A), C (D2A), -4 C (D2B), -2 C (D2B), C (D2B), -1-2 D1b -3 Room Temp Pixel1 Room Temp Pixel2-4 Room Temp Pixel3-6 -4-3 -2-1 Fig. 4 ROOM TEMPERATURE I-V RESULTS FOR THREE PIXELS OF DETECTOR D1B (ANODE DEPOSITION AFTER POLISHING, 2 MIN ETCHING AND HEAT TREATMENT AT 9 C FOR 3 MIN). DIFFERENT PIXELS SHOW DIFFERENT BEHAVIOURS. 662 kev energy spectra for a detector D1b pixel are displayed in Figs. 7 and 8. After correction we obtain 122 kev and 662 kev full width half maximum (FWHM) energy resolutions of 8 kev (6.4%) and 23 kev (3.4%), respectively. The energy resolution does depend on the surface treatment and the choice of contact materials. Table 1 gives the 662 kev resolutions for the different combinations of substrate, surface treatment, and contact material. Energy resolutions varied widely from detector to detector and from pixel to pixel. Here only the results for the best pixels are reported. For all the detectors, we tested three central pixels. The energy resolutions TABLE I TABLE 1. ENERGY RESOLUTIONS FOR DIFFERENT CONTACT MATERIALS AND SURFACE PREPARATION Detector Cathode/ Surface Energy Anode Treatment a Resolution (662 kev) D1a Pt/In Polish 8.4% D1b Pt/In Polish, Etch(2 min), 3.4% Heat (9 C-3 min) D2c Pt/In Polish High Leakage Current D2a Au/In Polish High Leakage Current D2b Pt/In Polish, Etch(2 min), 8.3% Heat (14 C,15 min) a The etching and heat treatment were performed only prior to depositing the In anodes. The cathodes were always deposited on the surfaces as polished. differed from pixel to pixel by 25%. It is evident that the combination of etching and heat treatment prior to contact deposition improves the performance for both detectors. While the detector D2 did not produce a spectrum with any photopeak prior to etching and heating, it did show a photopeak afterward, although the 662 kev energy resolution (55 kev, 8.3%) was still very modest. For the detector D1, the 662 kev energy resolution improved from 56 kev (8.4%) before heating and etching to 23 kev (3.4%) after etching and heating. Our test-setup allows us to measure the rise time of the pulses and thus to measure the electron drift times. Assuming that the detector is fully depleted, the longest pulse times result from electrons travelling the full.5 cm thickness of the detector, and the electron mobility µ e can be computed. Figure 9 shows the drift times for detector D1b. Longest drift times of.58 1 6 sec translate into a µ e -value of 86 cm 2 V 1 s 1.

Counts 9 8 7 6 5 4 3 2 1 Fig. 6 THE FIGURE SHOWS THE ANODE SIGNAL VS. THE CATHODE SIGNAL FOR DETECTOR D1B. THE PHOTOPEAK EVENTS ARE SHOWN IN BLUE AND LIE IN THE UPPER BAND. THE RATIO BETWEEN THE ANODE SIGNAL AND THE CATHODE SIGNAL CAN BE USED TO IMPROVE THE ENERGY RESOLUTION AND THE NUMBER OF EVENTS CONTRIBUTING TO THE PHOTOPEAK IN THE ENERGY SPECTRUM..2.4.6.8.1.12 Anode [V] Fig. 7 CO 57 (122 KEV) SPECTRUM TAKEN WITH A D1B PIXEL BEFORE (BLACK) AND AFTER (BLUE) CORRECTION FOR THE DOI BASED ON THE RATIO BETWEEN ANODE SIGNAL AND CATHODE SIGNAL (ANODE DEPOSITION AFTER POLISHING, 2 MIN ETCHING AND HEAT TREATMENT AT 9 C FOR 3 MIN). AFTER DOI CORRECTION THE ENERGY RESOLUTION IS 1 KEV (8.3%). IV. CONCLUSION We have presented here results on the spectroscopic performance of.5 cm thick CdTe crystals from the company Acrorad with a variety of electrodes fabricated by Washington Univeristy in St. Louis. At a substrate temperature of -4 C, our best results are 122 kev and 662 kev resolutions of 8 kev (6.4%) and 23 kev (3.4%), respectively. We have shown that changes in the surface preparation yield widely different detector performances. Our detectors showed a breakdown if biased for a sufficient time; the time before breakdown was longer for lower bias voltages and at colder detector temperatures. We cannot exclude the possibility that a combination of low bias voltage and low temperature may suppress the breakdown completely. Other authors have experimented with between.5 and 2. mm thick CdTe detectors. For example, using a.5 mm thick detector with an area of 1.9 1.9 cm 2, Oonuki et al. (25) report 122 kev and 511 kev energy resolutions of 1.6 kev (1.3%) and 5. kev (1%). Comparison of these results with our results is difficult as Oonuki et al optimized the contact deposition procedure with very detailed studies. We thus cannot determine to which degree the difference in detector performance results from the different detector thicknesses and from the different contacting techniques. [2] Ubertine, P. et al. A&A 411 L131, 23. [3] The Constellation Project Team, Constellation-X Technology Readiness and Implementation Plan (TRIP) Report. http://constellation.gsfc.nasa.gov/images/science/resources/documents/ TRIPReport NoCost.pdf [4] Grindlay, J.E. et al. Proc. SPIE 4851, 331, 23. [5] NeXT Satellite Proposal, the NeXT working group, ISAS, 23, submitted for publication. [6] Kunieda, H., Proc. SPIE 5488 (24) 187 [7] Takahashi, T. et al. NIMA 436 111, 1999. [8] Oonuki, K., Tanaka, T., Watanabe, S., et al. Proc. SPIE 5922 (25) 5922J-1 [9] Gnatyuk, V., Aoki, T., Hatanaka, Y., et al. Proc. SPIE 5922 (25) 5922I-1 [1] Aoki, T., Ishida, Y., Morii, H., et al. Proc. SPIE 5922 (25) 5922T-1 [11] Acrorad Co., Ltd., Wataru. Inui, 1-27-16, Hamamatsucho, Minatoku, Tokyo 15-13 [12] Krawczynski, H., Jung, I.V., Perkins, J., Burger, A., Groza, M. SPIE 49, 554, 13.1.(24). ACKNOWLEDGMENT This work was supported by NASA under contract NNG4WC176. We thank T. Takahashi for very useful discussions. REFERENCES [1] Gehrels, N. Proc. SPIE 414, 42, 2.

Fig. 8 CS 137 (662 KEV) SPECTRUM TAKEN WITH A D1B PIXEL BEFORE (BLACK) AND AFTER (BLUE) CORRECTION FOR THE DOI BASED ON THE RATIO BETWEEN ANODE SIGNAL AND CATHODE SIGNAL (ANODE DEPOSITION AFTER POLISHING, 2 MIN ETCHING AND HEAT TREATMENT AT 9 C FOR 3 MIN). AFTER DOI CORRECTION THE ENERGY RESOLUTION IS 23 KEV (3.4%). Fig. 9 ANODE SIGNAL VERSUS ELECTRON DRIFT TIMES FOR ONE PIXEL OF DETECTOR D1B (ANODE DEPOSITION AFTER POLISHING, 2 MIN ETCHING AND HEAT TREATMENT AT 9 C FOR 3 MIN).