INTRODUCTION TO DATA STUDIO

Similar documents
This manual describes the Motion Sensor hardware and the locally written software that interfaces to it.

Activity P07: Acceleration of a Cart (Acceleration Sensor, Motion Sensor)

Laboratory 1: Motion in One Dimension

Experiment P55: Light Intensity vs. Position (Light Sensor, Motion Sensor)

Experiment P10: Acceleration of a Dynamics Cart II (Motion Sensor)

Experiment P02: Understanding Motion II Velocity and Time (Motion Sensor)

PHYSICS 220 LAB #1: ONE-DIMENSIONAL MOTION

Experiment P11: Newton's Second Law Constant Force (Force Sensor, Motion Sensor)

Experiment P01: Understanding Motion I Distance and Time (Motion Sensor)

Computer Tools for Data Acquisition

Experiment 8: An AC Circuit

PHY 112L Activity 2 Electronics Primer

Experiment P20: Driven Harmonic Motion - Mass on a Spring (Force Sensor, Motion Sensor, Power Amplifier)

Activity P40: Driven Harmonic Motion - Mass on a Spring (Force Sensor, Motion Sensor, Power Amplifier)

Momentum and Impulse. Objective. Theory. Investigate the relationship between impulse and momentum.

Momentum and Impulse

GPS Position Sensor PS-2175

Activity P52: LRC Circuit (Voltage Sensor)

Modeling Your Motion When Walking

Physics activities using the ScienceWorkshop program and interfaces from PASCO scientific

Davis Art Images: Create and Share Slideshows

LAB 8: Activity P52: LRC Circuit

Sensor Calibration Lab

Physics 253 Fundamental Physics Mechanic, September 9, Lab #2 Plotting with Excel: The Air Slide

Experiment P24: Motor Efficiency (Photogate, Power Amplifier, Voltage Sensor)

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

CHM 152 Lab 1: Plotting with Excel updated: May 2011

Activity P55: Transistor Lab 1 The NPN Transistor as a Digital Switch (Power Output, Voltage Sensor)

CHM 109 Excel Refresher Exercise adapted from Dr. C. Bender s exercise

Experiment P58: Light Intensity in Double-Slit and Single-Slit Diffraction Patterns (Light Sensor, Rotary Motion Sensor)

Congratulations on your decision to purchase the Triquetra Auto Zero Touch Plate for All Three Axis.

Introduction to Motion

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

TEK-TROL HART GATEWAY SOFTWARE. Operating Instruction Manual.

Resistance Apparatus EM-8812

Studuino Icon Programming Environment Guide

Activity P57: Transistor Lab 3 Common-Emitter Amplifier (Voltage Sensor)

M. Conner Name: AP Physics C: RC Circuits Lab

Nikon View DX for Macintosh

Physics 3 Lab 5 Normal Modes and Resonance

Operating Rausch ScanCam within POSM.

Berklee College of Music: MTEC224 Digital Audio Basics/Systems LAB #4 Created by JAL Created on 11/22/06 4:54 AM Page 1 of 6

Ph 2306 Experiment 2: A Look at Sound

EENG-201 Experiment # 4: Function Generator, Oscilloscope

LAB 1 Linear Motion and Freefall

Instruction Manual. Ultrasonic and Radar

Apple Photos Quick Start Guide

Tektronix digital oscilloscope, BK Precision Function Generator, coaxial cables, breadboard, the crystal earpiece from your AM radio kit.

iphoto Getting Started Get to know iphoto and learn how to import and organize your photos, and create a photo slideshow and book.

Physics 131 Lab 1: ONE-DIMENSIONAL MOTION

Notes on Experiment #1

Exercise 1-1. Control of the Robot, Using RoboCIM EXERCISE OBJECTIVE

VOLTAGE. User Guide ACCESSORIES. External Sensor DT140. for MicroLog EC600 and EC V ±0.05V ±3% (before calibration)

Activity P56: Transistor Lab 2 Current Gain: The NPN Emitter-Follower Amplifier (Power Output, Voltage Sensor)

12 Projectile Motion 12 - Page 1 of 9. Projectile Motion

CURRENT. User Guide ACCESSORIES. External Sensor DT139. for MicroLog EC600 and EC mA ±0.1mA ±3% (before calibration)

Tinker Tuesday Project - Fabric Engraving

Graph Matching. walk back and forth in front of. Motion Detector

iphoto Objective Course Outline

An Introductory Guide to Circuit Simulation using NI Multisim 12

Teacher s Guide - Activity P51: LR Circuit (Power Output, Voltage Sensor)

How to Create Website Banners

Sodium Thiosulphate and hydrochloric acid

Laboratory Experiment #1 Introduction to Spectral Analysis

Logging into Five9 Telephony

Graphing Your Motion

Excel Tool: Plots of Data Sets

Sensor Calibration Lab

Concepts of Physics Lab 1: Motion

Exercise 8. Troubleshooting a Radar Target Tracker EXERCISE OBJECTIVE

Create A Mug. Skills Learned. Settings Sketching 3-D Features. Revolve Offset Plane Sweep Fillet Decal* Offset Arc

Introduction to Simulink Assignment Companion Document

ArbStudio Triggers. Using Both Input & Output Trigger With ArbStudio APPLICATION BRIEF LAB912

Analog Discovery Arbitrary Function Generator for Windows 7 by Mr. David Fritz and Ms. Ellen Robertson

teachweld Trainer Section 2: Usability Brought to you by Realityworks, Inc., the experiential learning technology company

Activity P51: LR Circuit (Power Output, Voltage Sensor)

Using the Hitachi 3400-N VP-SEM

Activity P35: Light Intensity in Double-Slit and Single-Slit Diffraction Patterns (Light Sensor, Rotary Motion Sensor)

Embroidery Gatherings

USING THE ARTISTRY SKIN ANALYZER

Volume of Revolution Investigation

MEDIA CONVERSION PROJECT: DIGITIZING HISTORIC PHOTOS

creation stations AUDIO RECORDING WITH AUDACITY 120 West 14th Street

Lab 1. Motion in a Straight Line

Motion Simulation - The Moving Man

The quantitative relationship between distance, time and speed

Lab 7: Magnetic Field of a Solenoid

2-Axis Force Platform PS-2142

Setting up Pro Tools I/O & connecting a microphone for Recording

Voltage Current and Resistance II

HOW CAN A GPS HELP? WHY A GPS? HOW DOES A GPS WORK?

How to Present External Audio Stimuli from PC - Focusrite Soundcards using the Aurical Aud Audiometer

TEMScripts Auto Image Measurement (Pattern) Manual. TEMScripts LLC. Last updated: 12/5/2016

Part 1. Tracing the Dimensions of Some Common Pixel Sizes using a GPS Receiver

Experiment P41: Induction Magnet through a Coil (Photogate, Voltage Sensor)

Gravitational Lensing Experiment

Calibration Instruction Manual Emerson 475 Field Communicator. Manual Revision FC.2

Standard Operating Procedure

MC3 Motion Control System Shutter Stream Quickstart

Kodu Game Programming

Transcription:

1 INTRODUCTION TO DATA STUDIO PART I: FAMILIARIZATION OBJECTIVE To become familiar with the operation of the Passport/Xplorer digital instruments and the DataStudio software. INTRODUCTION We will use the Passport/Xplorer devices to make measurements in many of the experiments in this laboratory. These devices plug into the laboratory computers and can be operated with the DataStudio software. We have several different probes available. The first probe that you will use is the Motion Sensor. The Motion Sensor is really the ultra-sonic range finder developed by the Polaroid Corp. for their cameras. It consists of an ultrasonic transducer that emits pulses of acoustic waves at ultrasonic frequencies and measures the time of flight of the pulses from the Motion Sensor to an object and back. In effect it is a sonar device. The basic measurement is the echo time which the computer reports as a distance. (The distance is computed from the time and the speed of sound.) The DataStudio software can also give you a computed velocity and acceleration of the object that is reflecting the signal. The velocity calculations can be useful, but you must beware of computation difficulties, especially near the stopping and starting times of the sensor. The calculated accelerations are often unreliable. You will be asked to calibrate the sensor for positions. Then knowing positions you can easily calculate velocities, either manually or with the DataStudio software. In carrying out the ACTIVITIES you will find reference to data or other information that need to be entered into your data sheets. In addition, there will be questions that should be answered there. We will use bold face to alert you to these items that must be answered. Data sheets are found at the end of each experiment. After they have been filled out, they may be torn out and given to your instructor. 1

ACTIVITY 1 ACTIVITY 2 ACTIVITY 3 1. Open DataStudio using the desktop icon. 2. Notice that the top toolbar has several buttons. You should see Summary and Setup buttons, among others. List all items displayed on the toolbar. 3. Three windows will pop up. You will see two of these windows displayed on the left-hand side of your screen. The Data menu should be empty. The Displays menu should have several items listed. Name four of these listed items. 4. The third window, at the bottom of your screen, should say Plug in a PASPORT sensor to add a measurement to this activity. 5. Press the Summary button (on the top toolbar) and observe what happens. What did pressing the Summary button do? Press the button once more. 6. On the Displays menu, double-click the graph icon to open a graph. Click on the X in the upper left corner of the graph window (the usual button to close a window). A message should pop up asking if you want to completely remove this display from your activity. 7. Remove the graph window. Caution: Clicking OK or hitting the return key will completely remove the window from your activity. The graph will be deleted and you will not be able to retrieve it. 8. Click on the Setup button. A window called Experiment Setup will appear. It displays the following message There are no sensors in this activity. Please connect a PASPORT sensor or click the Add Sensor button to set up an activity. 9. Click the Add Sensor button. A window with a list of sensors will appear. List four of the available sensors. 2

ACTIVITY 4 10. Click on Motion Sensor and press OK. Study all of the windows carefully and describe what happened when you selected Motion Sensor. 11. If a graph window opened, close it as described previously. 12. The Experiment Setup window should now show a motion sensor icon (a stick figure). Notice that there is an exclamation point in a yellow circle overlapping the sensor icon. indicates that no sensor is plugged in. This symbol ACTIVITY 5 ACTIVITY 6 13. Under the motion sensor icon, there is a line with Sampling Rate listed. The default sampling rate is 10 Hz. Click on the plus or minus buttons to increase or decrease the sampling rate. What is the maximum sampling rate achievable? What is the minimum sampling rate allowed? 14. Notice that the units, Hz, may be changed by clicking on the up/down arrows and selecting different units. List all the allowed units of sampling rate. 15. The Experiment Setup window contains three boxes. They are labeled Position, Velocity, and Acceleration. The units in which these three quantities are measured are also listed. 16. Currently, the Position box is checked. Check the Velocity and Acceleration boxes. What happens when you check these boxes? 17. Click the Setup button again to make this screen disappear. 18. Connect the motion sensor to the computer via the USB link. What happens to your icons when you plug in the motion sensor? 19. Drag the Position icon from the Data menu down over the Graph icon in the Displays menu. A graph will appear. Notice that a window pops up at the bottom of the screen which reads Click the Start button to begin collecting data. 3

ACTIVITY 7 ACTIVITY 8 ACTIVITY 9 20. If the exclamation symbol is still overlapping your sensor icon, try reconnecting the motion sensor to the computer. 21. Set the motion probe on the table next to you. Point the front screened panel of the probe directly toward you. 22. Click the Start button now. You should hear the motion probe making a clicking sound. Wait several seconds, then press Stop. You have just collected data. 23. Quit DataStudio without saving this activity. Leaving the motion sensor connected to the computer, restart DataStudio. Notice that you already have a position icon in the Data menu. A graph is automatically opened as well. 24. You should see a message at the bottom of your screen telling you to Click the Start button to begin collecting data. 25. Quit DataStudio without saving this activity. Disconnect the motion sensor. 26. Reopen DataStudio once more. Everything should appear as it did when you first opened DataStudio (in Activity 1). 27. Instead of clicking Setup, go ahead and plug the motion sensor into the computer. 28. A position icon should appear in the Data menu and a graph window should pop up. Quit DataStudio. SUMMARY After this introduction, you should be able to set up a motion sensor probe for use with DataStudio. You should also be able to change the types of data (Position, Velocity, and Acceleration) as well as varying the sampling rate. You are now ready to begin using the sensors. Move on to the Motion Sensor experiment. 4

Data sheets to hand in. Name INTRODUCTION TO DATA STUDIO PART I: DATA SHEETS ACTIVITY 1 List all items displayed on the toolbar. Name four of the items listed in the Displays menu. 1. 2. 3. 4. ACTIVITY 2 What did pressing the Summary button do? ACTIVITY 3 List four of the available sensors. 1. 3. 2. 4. Study all of the windows carefully and describe what happened when you selected Motion Sensor. 5

ACTIVITY 4 What is the maximum sampling rate achievable? What is the minimum sampling rate allowed? List all the allowed units of sampling rate. ACTIVITY 5 What happens when you check the Velocity and Acceleration boxes? ACTIVITY 6 What happens to your icons when you plug in the motion sensor? ACTIVITIES 7-9 No questions in these activities. 6

I 1 INTRODUCTION TO DATA STUDIO PART II: MOTION SENSOR INTRODUCTION In making any measurement you need to be aware of the reliability of the instruments you are using. Can they be trusted to give you correct results? There are two terms that we use to describe instrumental reliability, accuracy and precision. If you make several measurements and the readings are very close together, then you say that the instrument is precise. That is, the spread in the measurements is small and the uncertainty in the readings is small. If the average of the measurements is close to the correct reading, then the instrument is said to be accurate. In some cases, your instruments will be both accurate and precise. However, they could be accurate but not precise, precise but not accurate, or neither. For this reason, you should always calibrate instruments by comparing them to a standard. In the activities below you will compare the measurements of distance made with the Motion Sensor to those made with a meter stick. ACTIVITY 1 ACTIVITY 2 Connect the motion sensor to your computer. Double-click on the Motion Sensor.ds icon to open the Introduction to DataStudio: Motion Sensor lab. Several graphs and menus should pop up as well. Do not blindly trust the motion sensor. You should determine if it is taking accurate measurements. Notice that the motion sensor has two range settings. One setting is denoted with a cart symbol and the other with a stick figure. In the following activities, you will compare the two settings. 1. Set the motion probe for the people range and perform the following steps: a. Position the probe approximately 0.5 m from the wall. Make sure the screened panel is facing the wall and is perpendicular to it. 7

I b. Measure the distance from the wall to the screened panel on the front of the motion probe with a meter stick. Record your measurement. c. Press the Start button and allow the probe to collect data for several seconds. Press the Stop button. Drag this data run to the Graph icon to generate a new graph. d. Rescale the graph along the y-axis to get the most effective scale. (See the DataStudio activity Graph Introduction.ds on your desktop for help.) What is the distance determined by the motion sensor? e. Repeat steps 1a-d for measurements for several distances between 0.5 m and 5 m. (See the data table.) What is the range of the motion probe using the people range? ACTIVITY 3 f. What are the limits of the motion probe in terms of accuracy? 2. Set the motion probe for the cart range and perform the following steps: a. Position the probe approximately 0.5 m from the wall. Make sure the screened panel is facing the wall and is perpendicular to it. b. Measure the distance from the wall to the screened panel on the front of the motion probe with a meter stick. Record your measurement. c. Press the Start button and allow the probe to collect data for several seconds. Press the Stop button. Drag this data run to the Graph icon to generate a new graph. d. Rescale the graph along the y-axis to get the most effective scale. What is the distance determined by the motion sensor? e. Repeat steps 2a-d for measurements at 1m, 2 m, 3 m, and 5 m. What is the range of the motion probe using the cart range? f. What are the limits of the motion probe in terms of accuracy? 8

I Data sheets to be handed in. Name INTRODUCTION TO DATA STUDIO: PART II: MOTION SENSOR DATA SHEETS ACTIVITY 1 No questions for this activity. ACTIVITY 2 Approximate Distance People-Range Distance Measurements Measured Distance [Meter-stick] Measured Distance [Motion Sensor] (m) (m) (m) 0.50 0.75 1.00 1.50 2.00 3.00 5.00 What is the range of the motion probe using the people range? What are the limits of the motion probe in terms of accuracy? 9

I ACTIVITY 3 Approximate Distance Cart Range Distance Measurements Measured Distance [Meter-stick] Measured Distance [Motion Sensor] (m) (m) (m) 0.50 0.75 1.00 1.50 2.00 3.00 5.00 What is the range of the motion probe using the cart range? What are the limits of the motion probe in terms of accuracy? 10