commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

Similar documents
Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

FSK1VDRA 1G Al DPLX RCPT CVR

AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover.

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

Ground Clamps Cable Tray

Thru Wall Floor Seals For New Installation

General Information...SA1-SA4

Series 5 Die Cast Aluminum Conduit Outlet Bodies, Covers and Gaskets

BELL. RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

A-51 Incandescent Factory Sealed Luminaires Explosionproof Suitable for use in Wet Locations. UNILETS for use with Threaded Metal Conduit.

Perma-Cote Submittal Guide Contents

Industrial Areamaster Generation 2 HL LED Luminaire Floodlight for Ordinary Locations

INTERMEDIATE METAL CONDUIT

RACO Commercial Fittings

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6

Cast Iron Junction Boxes

E.M.T. Set-Screw Connectors. Technical Specifications

Polished Brass. Stainless Steel

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

RACO Commercial Fittings

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

WALL PLATES & SPECIALTIES

Floor Boxes. Flush Service Floor Boxes

Industrial Mercmaster LED Generation 3 Series Luminaires For Ordinary Locations

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

PIPE/CONDUIT SUPPORTS

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations

Class II, Division 1 and 2, Groups E, F, G Class III CSA 4X

Bullet EL Volt Die-Cast Aluminum, PAR38 Incan. / Halogen / R40 Incan. revision 8/15/11 el220.pdf

WALL PLATES & SPECIALTIES

Applications. Illustrated Features. Certifications and Compliances

Spun Copper Bullet C to 277 Volt Spun Copper LED revision 11/7/14 kl_c24led_spec.pdf

Baymaster HL LED Luminaire High Bay for Hazardous Locations

SECTION METAL FABRICATIONS

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Iberville. Commercial Grade Fittings EMT CI5410 / CI5432 CI5410IT / CI5432IT CI5404 / CI5408 CI5404IT / CI5408IT CI5004 (-IT) / CI5008 (-IT)

Specifications. S&C Cypoxy Insulators. Indoor and Outdoor Distribution (4.8 kv through 46 kv) Conditions of Sale

SECTION CABLE TRAYS

Section 2 Outdoor Voltage Transformers

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Baymaster LED Luminaire High Bay for Hazardous Locations

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

HSAF Era Stepped Aluminum Fluted Pole revision 10/6/15 kl_hasf_spec.pdf

Micro-Flood EL / 277 Volt Die-Cast Aluminum LED revision 4/11/11 el217.pdf

WALL PLATES & SPECIALTIES

APPLICATION COMMERCIAL, INDUSTRIAL AND RESIDENTIAL; SCREW MOUNTED Gen Purpose Wiring Devices - Wall Plates & Covers

WALL PLATES & SPECIALTIES

Mercmaster LED Low Profile Luminaires with Emergency Battery Backup Enclosed and Gasketed Fixtures

Polished Brass. Stainless Steel

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

Tuf-Lite II Fans 3000H Series Hub

Wall Plates & Specialties

(1) F COAXIAL CONNECTOR, (1) RJ11 MODULAR JACK. Application Telephone, CATV; Approval UL 514/1683, CSA

SECTION EQUIPMENT WIRING

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job:

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Steel City Comparison & Strategy. vs. T&B Liquidtight Fittings. Andrea Briggs. Associate Product Manager - Conduit & Fittings FOR INTERNAL USE ONLY

Bol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:

Tuf-Lite III Fans 3000K Series Hub

Tuf-Lite II Fans H Hi Temp 3000HT Series Hub

U CON DUIT CODEGUARD. 10-IN-1 UNIVERSAL CONDUIT BODY for RIGID/IMC or EMT. Service Truck Solutions

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

Polished Brass. Stainless Steel

SECTION SWINGING AUTOMATIC ENTRANCES

Tuf-Lite II Fans 3000H Series Hub

WALL PLATES & SPECIALTIES

Project: Type: Qty: QH2L. Series Optics Mounting Light Engine CCT Finish Voltage Option. Options QH2L 27 3 /8" 23 3 /16" 3 1 /2" O.D. Pole.

tings fi t fl ex/mc/ac

Tuf-Lite II Fans 3000HC Series Hub

SWP26BN Brush Nickel Cover. Descriptions. Manufacturer Information PASS & SEYMOUR GTIN Manufacturers Part Number UPC

CONTINUING EDUC ATION

SECTION TRANSFORMERS

FLUORESCENT/AREA: NEC/CEC EXPLOSIONPROOF. Applications. Illustrated Features

Architectural Door Accessories. Markar Continuous Hinges

SECTION PANELBOARDS

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

Floor Boxes. Table of Contents

Overview Better by Design

Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub

A. Product Description: Stranded conductor insulated wire.

Regal Series Recessed Flatwalls

WALL PLATES & SPECIALTIES

NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

content Introduction Some good reasons to use SMARTr products Reducers, Plugs Conduit Reducer Stopping Plug

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

MAST ARMS & POLES. Ornamental Pole Top & Bases

REPAIR CLAMP PARTS H fax: MULTIPLIER

Waterpipe Ground Clamps. 1/2 in., 3/4 in., 1 or rebar /4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 AWG

Flush Round Single or Multi-Service Non-Metallic Concrete Floor Box Floor Boxes

Quarter-Turn Fasteners

Tuf-Lite III Fans 5000K Series Hub

Transcription:

UNILETS for use with Threaded Rigid Conduit and IMC. All Device Boxes have Construction. Furnished with Internal Ground Screw. Applications Accommodate wiring devices such as switches and receptacles. Provide excellent service in areas where boxes are subject to rough usage. Serve as pull boxes for conductors. Permit access to conductors for maintenance. Provide openings for making splices. Allow connections for branch conduit runs. Blank bodies for special conduit entrance arrangements. Features Corrosion-resistant ideal for indoor and outdoor installations. Weatherproof, raintight and dust-tight when used with cast gasketed covers. FS and FD boxes take standard flush wiring devices. FD boxes take devices exceeding 41.4 mm (1.63 in) in depth under fastening ears. Malleable iron for high tensile strength and ductility provides greater resistance to impact and shock. Both malleable iron and aluminum boxes have ridge top construction for positive cover/gasket/box fit. Accurately tapped, tapered threads for tight, rigid joints, ground continuity. Complete selection of covers, receptacles, plugs, gaskets and accessories. Covers have captive stainless steel screws to speed installation, prevents loss of screws. Internal grounding screws standard. Available in single, two and three gang and tandem. Smooth, rounded integral bushing in each hub protects conductor insulation. Standard Materials Boxes: malleable iron or copperfree (4/10 of 1% max.) aluminum Covers: malleable iron, steel, or copperfree (4/10 of 1% max.) aluminum Screws: stainless steel Gaskets: neoprene Standard Finishes Malleable iron boxes and covers: triple-coat (1) zinc electroplate, (2) chromate, and (3) epoxy powder coat Aluminum boxes and covers: epoxy powder coat Steel covers: zinc electroplate Options For additional corrosion protection, specify Hot Dip Galvanized. Add suffix -G to catalog number. Contact your local representative for pricing and availability. NEC/CEC Certifications and Compliances UL Standard: 514A UL Listed: E-18095, E2527 CSA Standard: C22.2 No. 18 CSA Certified: 009795 Suitable for wet locations when used with gasketed covers. Fed Spec: A-A-50563 NEMA Standard: FB-1 Illustrated Features Gasket is designed so that it wraps around ridge top of O-Z/Gedney aluminum or malleable iron device box. Result is a positive seal against moisture. Gasket construction. Cover tightens on largest perimeter of gasket and fits snugly against portion of gasket that wraps around ridge top of box. 122

UNILETS for use with Threaded Rigid Metal Conduit and IMC. Furnished with Internal Ground Screw. FS Box () 2.00 deep, FD Box () 2.69 deep, ED (Extra ) 3.06 deep Type FS FD FSC FDC FDL FDR Depth (extra deep without mounting feet) (extra deep without mounting feet) Trade Size Malleable Iron Aluminum 1/2 FS-1-50 FS-1-50-A 3/4 FS-1-75 FS-1-75-A 1 FS-1-100 FS-1-100-A 1/2 FD-1-50 FD-1-50-A 1/2 FD-1-50ED FD-1-50-AED 3/4 FD-1-75 FD-1-75-A 3/4 FD-1-75ED FD-1-75-AED 1 FD-1-100 1/2 FSC-1-50 FSC-1-50-A 3/4 FSC-1-75 FSC-1-75-A 1 FSC-1-100 1/2 FDC-1-50 FDC-1-50-A 1/2 FDC-1-50ED FDC-1-50-AED 3/4 FDC-1-75 FDC-1-75-A 3/4 FDC-1-75ED FDC-1-75-AED 1 FDC-1-100 1 FDC-1-100ED FDC-1-100-AED 1/2 FDL-1-50 3/4 FDL-1-75 1/2 FDR-1-50 3/4 FDR-1-75 1/2 FDA-1-50 FDA 3/4 FDA-1-75 FSS 1/2 FSS-1-50 3/4 FSS-1-75 FSS-1-75-A Extra deep with mounting feet. Shaded boxes include mounting feet. 123

UNILETS for use with Threaded Rigid Metal Conduit and IMC. FS Box 2.00, FD Box 2.69. Furnished with Internal Ground Screw. FS Box () 2.00 deep, FD Box () 2.69 deep, ED (Extra ) 3.06 deep Type Depth Malleable Iron Aluminum FSCC 1/2 FSCC-1-50 3/4 FSCC-1-75 FSCC-1-75A 1/2 FDCC-1-50 1/2 FDCC-1-50ED FDCC 3/4 FDCC-1-75 3/4 FDCC-1-75ED FSCT FDCT FSX 1 FDCC-1-100 1/2 FSCT-1-50 3/4 FSCT-1-75 1 FSCT-1-100 1/2 FDCT-1-50 1/2 FDCT-1-50ED 3/4 FDCT-1-75 3/4 FDCT-1-75ED 1 FDCT-1-100 1 FDCT-1-100ED 1/2 FSX-1-50 3/4 FSX-1-75 1/2 FDX-1-50 FDX 1/2 FDX-1-50ED 3/4 FDX-1-75 3/4 FDX-1-75ED Extra deep with mounting feet. 124

UNILETS for use with Threaded Rigid Metal Conduit and IMC. FS Box 2.00, FD Box 2.69. Furnished with Internal Ground Screw. FS Box () 2.00 deep, FD Box () 2.69 deep, ED (Extra ) 3.06 deep Type Depth Malleable Iron Aluminum FS Two-Gang Tandem Boxes Takes single gang covers FS 3/4 FS-2T-75 125

Steel Covers and Aluminum Covers for Boxes. Furnished with Stainless Steel Screws, Less Gasket. Description Steel Aluminum For square handle tumbler or toggle switches. FS1-SCS For round receptacles. Mounts directly on box. Hole Dia. 1-13/32. For round receptacles. Mounts directly on box. Hole Dia. 1-5/8. 3-9/32 C to C screw holes. FS1-SRCS FS1-LRCS For standard 2 or 3 wire duplex receptacles. FS1-DCS Blank FS1-BCS Blank FS1-BC (Gray iron) FS1-BC-A 126

Covers for Boxes. Description Cast Covers NEMA 3R Wet Locations Furnished with gasket and stainless steel screws Malleable Iron Aluminum Round receptacle Hole Diameter 1-7/16" FS1-WRCA FS1-WRCA For duplex flush receptacle with spring cover FS1-WDC-A For external operation of tumbler switches with square handles FS1-WPCA FS1-WPCA Operating type for square handle tumbler or toggle switches FS1-WSCA FS1-WSCA Rocker type for square handle tumbler or toggle flush switches FSK-1V-A Gasket Replacement Neoprene for use with wet location covers FS1-SG Cast Covers Dry Locations Furnished with stainless steel screws less gasket For standard 2 or 3 wire duplex receptacles FS1-DC FS1-DC-A FS1-DC Ground fault receptacle FS1-GFCA FS1-GFCA 127

Wiring Capacity Single-Gang FS Capacity dm 3 (in 3 ) Single-Gang FD Two-Gang Tandem FS 1/2 0.29 (18.00) 0.41 (25.00) 0.66 (40.00) 3/4 0.29 (18.00) 0.41 (25.00) 0.66 (40.00) 1 0.29 (18.00) 0.41 (25.00) 0.66 (40.00) Dimensions in Millimeters FS and FD Single Gang Boxes without lugs FS Tandem Boxes FS and FD Single Gang Boxes with lugs Hub Size A B C Dimensions in Millimeters D G FS FD E F FS FD 1/2 149.4 (5.88) 28.7 (1.13) 16.0 (0.63) 50.8 (2.00) 68.3 (2.69) 38.1 (1.50) 88.9 (3.50) 45.2 (1.78) 62.0 (2.44) 42.9 (1.69) 3/4 149.4 (5.88) 35.1 (1.38) 19.1 (0.75) 50.8 (2.00) 68.3 (2.69) 52.3 (2.06) 88.9 (3.50) 45.2 (1.78) 62.0 (2.44) 38.1 (1.50) 1 160.3 (6.31) 42.9 (1.69) 23.9 (0.94) 50.8 (2.00) 68.3 (2.69) 52.3 (2.06) 88.9 (3.50) 45.2 (1.78) 62.0 (2.44) 35.1 (1.38) H 128

Dimensions in Millimeters Type FD Extra 136.7 (5.38) 73.2 (2.88) 74.7 (2.94) 73.2 (2.88) 47.8 (1.88) 55.6 (2.19) 74.7 (2.94) 28.7 (1.13) 28.7 (1.13) Catalog Number All FD Type Boxes 28.7 (1.13) 7.9 (0.31) 73.2 (2.88) 136.7 (5.38) 119.1 (4.69) 119.1 (4.69) 119.1 (4.69) 100.1 (3.94) Two Gang With Mounting Lugs Single Gang 119.1 (4.69) With Mounting Lugs Dimensions in Millimeters A B C D E F 1/2 19.05 (0.75) 77.72 (3.06) 73.15 (2.88) 16.00 (0.63) 119.13 (4.69) 100.08 (3.94) 3/4 19.05 (0.75) 77.72 (3.06) 73.15 (2.88) 19.05 (0.75) 115.82 (4.56) 96.77 (3.81) 1 22.35 (0.88) 77.72 (3.06) 73.15 (2.88) 22.35 (0.88) 129

UNILETS for use with Threaded Rigid Metal Conduit and IMC. Furnished with Internal Ground Screw. FS Box () 2.00 deep, FD Box () 2.69 deep, ED (Extra ) 3.06 deep Type Depth Malleable Iron Aluminum 1/2 FS-2-50 FS 3/4 FS-2-75 FS-2-75-A 1 FS-2-100 1/2 FD-2-50 FD 3/4 FD-2-75 1 FD-2-100 1/2 FSC-2-50 FSC 3/4 FSC-2-75 1 FSC-2-100 FDC 1/2 FDC-2-50 3/4 FDC-2-75 1 FDC-2-100 Largest hub at bottom in illustration. Extension does not have a ground screw. 130

Stamped Steel and Aluminum Covers With stainless steel screws, less gasket Description Steel Aluminum For square handle tumbler or toggle flush switches FS-2-SCS For duplex flush receptacles FS-2-DCS For tumbler flush switch and duplex flush receptacles FS-2-SDCS Cast Covers Weatherproof With gasket and stainless steel screws For external operation of tumbler switches with square handles Blank Cover Gasket Replacement FS-2-BC (Gray iron) Neoprene for use with 2-gang cast covers above Malleable Iron Aluminum FS-2-WSCA FS-2-BCS FS-2-BCA FS-2-SG 131

Wiring Capacity FS Capacity dm 3 (in 3 ) FD 1/2 0.52 (32.00) 0.74 (45.00) 3/4 0.52 (32.00) 0.74 (45.00) 1 0.52 (32.00) 0.74 (45.00) Dimensions in Millimeters Dimensions in Millimeters D A B C FS FD E FS FD 1/2 149.4 (5.88) 28.7 (1.13) 16.0 (0.63) 50.8 (2.00) 68.3 (2.69) 47.8 (1.88) 45.2 (1.78) 62.0 (2.44) 3/4 149.4 (5.88) 35.1 (1.38) 19.1 (0.75) 50.8 (2.00) 68.3 (2.69) 47.8 (1.88) 45.2 (1.78) 62.0 (2.44) 1 160.3 (6.31) 42.9 (1.69) 23.9 (0.94) 50.8 (2.00) 68.3 (2.69) 52.3 (2.06) 45.2 (1.78) 62.0 (2.44) F 132