Sound Meter Type 1 840015
Sound Meter Type 1-840015 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means electronic, mechanical, or other means that do not yet exist or may be developed, including photocopying, recording, or any information storage and retrieval system without the express permission from Sper Scientific. TABLE OF CONTENTS INTRODUCTION...3 PANEL DESCRIPTION...3 OPERATING INSTRUCTIONS....4 MEASURE PROCEDURE...4 GENERAL APPLICATION SETTINGS...4 SIGNAL OUTPUT...5 PRECAUTIONS...5 CALIBRATION...5 BATTERY REPLACEMENT...6 FREQUENCY WEIGHTING (A & C) CHARACTERSITCS....6 TIME WEIGHTING (FAST & SLOW) CHARACTERSITCS...6 SPECIFICATIONS...7 WARRANTY....8 2
INTRODUCTION Your new instrument meets IEC61672 and ANSI S1.43 specifications for a Type 1 Sound Meter. It covers the 30 to 130 db range in both the A and C decibel frequency weighting scales, with 0.1 db resolution and an accuracy of ±1 db (63 Hz to 4 khz). This meter can be acoustically calibrated in compliance with OSHA, using Sper Scientific s Acoustical Calibrator 850016 (or equivalent). Features include a built-in calibration adjustment, easy to read LCD display, fast or slow time weightings, maximum hold function, low battery indicator, AC output and a reset button. CE compliant. Accessories include a windscreen, calibration tool, a carrying case, instruction manual and batteries. PANEL DESCRIPTION 1. Microphone (shown with windscreen) 1 2. Threaded Microphone Cap 3. Overload indicator 4. Display 2 5. Range selector 6. Power/Calibration selector 7. Time Weighting selector 8. Max Hold/Instant selector 9. Calibration Adjustment 10. Reset button 11. Frequency Weighting selector 12. Signal Output Terminal 3 4 5 6 7 8 9 10 11 12 3
OPERATING INSTRUCTIONS Measurement Procedures 1. Slide the POWER (6) selector to the I (on) position. 2. For general applications, slide the MAX HOLD / INSTANT (8) selector to the INSTANT position. 3. To freeze the displayed reading, slide the MAX HOLD / INSTANT (8) selector to the MAX HOLD position. 4. Press the RESET (10) button once to reset maximum hold to the current reading. 5. Slide the FREQUENCY WEIGHTING (11) selector to the A or C position. The A frequency weighting simulates human ear response. During an environmental sound level measurement, select the A weighting. The C weighting approximates a flat response. Typically, C is used to check the noise of machinery where the target sound level is already known. (See Frequency Weighting Characteristics, page 6.) 6. Slide the TIME WEIGHTING (7) selector to the F (fast) or S (slow) position. For general applications, select F which simulates the human ear s response time. The S setting is used to obtain an average of vibrating sound levels. 7. Find the appropriate measuring range using the RANGE (5) selector. If the OVERLOAD INDICATOR (3) appears in the upperleft display, slide the RANGE (5) selector to another setting. 8. Point the microphone at the sound source. The sound level will be displayed in decibels (db). 9. When finished, slide the POWER (6) selector to the O (off) position. General Application Settings 1. Set POWER / CALIBRATION (6) selector to I (on). 2. Set TIME WEIGHTING (7) to F. 3. Set MAX HOLD / INSTANT (8) selector to INSTANT. 4. Set FREQUENCY WEIGHTING (11) to A. 5. Set RANGE (5) selector to the appropriate range. 4
Signal Output The 3.5 mm diameter SIGNAL OUTPUT (12) terminal may be used to connect the unit to an external device (analyzer, recorder, controller, etc). Precautions Do not store or operate the unit in high temperatures or in a high humidity environment for long periods. Keep the microphone dry and avoid intense vibrations. CALIBRATION The meter s CALIBRATION ADJUSTMENT (9) is located on the front panel. The meter has a built-in internal standard of 94 db/1 KHz. Use the following procedures to calibrate the instrument before operating for the first time, or when the meter has not been in use for awhile. Internal Calibration 1. Slide the POWER (6) selector to the CAL. Position. 2. Slide the RANGE (5) selector to the 60 to 100 db position. 3. Slide the TIME WEIGHTING (7) selector to F. 4. Slide the FREQUENCY WEIGHTING (11) selector to A. 5. Use the calibration screw driver to turn the CALIBRATION ADJUSTMENT (9) until the display reads 94.0. External Calibration Use Sper Scientifics Acoustical Calibrator 850016 (or equivalent) to calibrate the unit, including the microphone, in compliance with OSHA. 1. Slide POWER (6) selector to the I (on). 2. Turn on the acoustical calibrator and place it onto the Sound Level Meter s MICROPHONE (1). 3. Slide the RANGE (5) selector to the 60 to 100 db position. 4. Slide the TIME WEIGHTING (7) selector to F. 5
5. Slide the FREQUENCY WEIGHTING (11) selector to A. 6. Use the calibration screw driver to turn the CALIBRATION ADJUSTMENT (9) until the display reads 94.0. BATTERY REPLACEMENT Replace the batteries when BAT is displayed. Accurate measurements may be made for several hours after the low battery indicator appears. Replace the batteries with 2 new heavy duty 9V batteries. FREQUENCY WEIGHTING (A & C) CHARACTERISTICS Frequency A Weighting C Weighting Tolerance (IEC 61672 Class 1) Tolerance (ANSI S1.43 Type 1) 31.5 Hz -39.4 db -3 db ± 2.0 db ± 1.5 db 63 Hz -26.2 db -0.8 db ± 1.5 db ± 1.0 db 125 Hz -16.1 db -0.2 db ± 1.5 db ± 1.0 db 250 Hz -8.6 db 0 db ± 1.4 db ± 1.0 db 500 Hz -3.2 db 0 db ± 1.4 db ± 1.0 db 1 khz 0 db 0 db ± 1.1 db ± 1.0 db 2 khz +1.2 db -0.2 db ± 1.6 db ± 1.0 db 4 khz +1 db -0.8 db ± 1.6 db ± 1.0 db 8 khz -1.1 db -3 db 12.5 khz -4.3 db -6.2 db 16 khz -6.6 db -8.5 db +2.1 db -3.1 db +3.0 db -6.0 db +3.5 db -17.0 db +1.5 db -6.0 db +3.0 db -6.0 db +3.0 db -no limit TIME WEIGHTING (FAST & SLOW) CHARACTERISTICS Time Weighting Max. response ref. continuous signal 6 Tolerance (IEC 61672 Type 1) F (Fast) -1.0 db + 1.0 db S (Slow) -4.1 db ± 1.0 db Tested with signal on 1000 Hz/94 db.
SPECIFICATIONS Display Function Measurement Range Resolution Accuracy (23 ± 5 ) Frequency Microphone Time weighting (Fast/Slow) Internal Calibration Output Signal Output Terminal Operating Env. Power Supply Power Consumption Dimension 18 mm (.0.7") LCD 3¼ digits db ( A and C Frequency weighting), Time weighting (Fast, Slow), Max. hold, AC Output 30-70 db, 60-100 db, and 90-130 db 40 db on each step, with overload indicator 0.1 db Frequency weighting meets ANSI S1.43 calibration input signal on 94 db 31.5 Hz to 8 khz), then the accuracy of "A" weighting is specified as: 31.5 Hz - ± 1.5 db, 63 Hz - ± 1 db 125 Hz - ± 1 db, 250 Hz - ± 1 db 500 Hz - ± 1 db, 06 khz - ± 1 db 2 khz - ± 1 db, 4 khz - ± 1 db 8 khz - + 1.5 db to - 3 db 12.5 khz - + 3dB to - 6dB 16 khz - + 3dB to - No Limit 31.5 Hz to 16 khz 1/2" standard size electric condenser microphone. Threaded microphone cap unscrews for microphone replacement. Fast (F): t = 125 ms Slow (S): t = 1000 ms Built-in internal calibration on front panel. Calibrated via internal 94 db/1khz square wave generator. AC 750 mvrms corresponding to each range step 3.5 mm diameter jack 0 to 50 C (32 to 122 F) and less than 80% RH DC 9V battery x 2PCs, 0006P, MN1604 (PP3) or equivalent, heavy duty or alkaline type Approximately DC 17mA Weight 16.1 oz (454 g) 10½" 3½" 1½" (267 89 38 mm) 7
WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will break the waterproof seal and void the warranty. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD. 8281 East Evans Road, Suite #103 Scottsdale, AZ 85260 The defective unit must be accompanied by a description of the problem and your return address. Register your product online at www.sperwarranty.com within 10 days of purchase. 05/2015 8