Sound Meter Type

Similar documents
Microwave Meter. Instruction Manual

Smartphone RH/Temperature Probe Instruction Manual

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

UVA/B Light Meter. Instruction Manual. UVA/B Light Meter Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

Mini Environmental Quality Meter

! Warning, refer to accompanying documents.

Sound Level Meter C.A 832

Simpson Model Sound Level Meter OPERATOR S MANUAL

DIGITAL SOUND LEVEL DSM8930 METER USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

instructions for Models QC-10 and QC-20 Sound Calibrators MODELS QC-10/QC-20 SOUND CALIBRATORS GENERAL DESCRIPTION

Simpson Model 899 Sound Level Meter OPERATOR S MANUAL

PIECAL Model 541 Frequency Calibrator with Totalizer Operating Instructions

MFJ Enterprises, Inc. 300 Industrial Park Rd Starkville, MS USA

7/05 FORM#352 OPERATING INSTRUCTIONS ALL WEATHER DIGITAL LEAKAGE CURRENT TESTER DSA-2417

Advanced Test Equipment Rentals ATEC (2832)

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

Advanced Test Equipment Rentals ATEC (2832)

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

AC/DC Current Oscilloscope Probe Model SL261

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Professional UHF Rechargeable Wireless Microphone System POWER ON/OFF BATTERY CHARGE. Green Light (Full) Better Music Builder DOWN VOLUME

True RMS AC / DC Power Clamp Meter Model

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

32 CHANNEL SELECTABLE CH MHZ DOWN VOLUME

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

QUICK TESTER FOR TRANSFORMERS AND CAPACITORS

WIRELESS 915 MHz TEMPERATURE STATION Instruction Manual

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Testing to IEC

SPM-50 RF Spectrum Power Meter PC Software User Manual

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

SCREENING EFFICIENCY TESTER Model 271

Model 7000 Low Noise Differential Preamplifier

DM-46 Instruction Manual

Bedienungsanleitung Instruction Manual. testo 815 Sound Level Meter

Operator s Manual. PP022 Passive Probe

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

Contents. Page English 1. French. Spanish. Reset of MIN/MAX records 915 MHz Reception Mounting Care and Maintenance Warranty Information

BM22s, BM25s, BM25a & BM27s USER'S MANUAL

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

Random & Sinusoidal Jitter Injector. Main Unit Operation Manual

PA WATT PORTABLE PA SYSTEM PRODUCT MANUAL

User s Guide ASSISTIVE LISTENING SYSTEMS

2000 A DCA/ACA CLAMP + DMM,

User s Manual. Ground Resistance Clamp On Tester MODEL

Process Calibrator. TechChek 820

WIRELESS 915 MHz TEMPERATURE STATION Instruction Manual

MiniFlex MF HF MF HF FLEXIBLE AC CURRENT SENSOR. User Manual. High Frequency Response for Oscilloscopes

TA MHz oscilloscope probe TA MHz oscilloscope probe

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

spy pig Tracking systems

Non-contact Forehead IR Thermometer

Assembly Instructions flipforms

MiniFlex MF MF FLEXIBLE AC CURRENT SENSOR. User Manual

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

Contents. English 1. French 29. Spanish. FEATURES: The Temperature Station

DDM350 Pen-Type Digital Multimeter User s Manual

DM-46 Instruction Manual

INSTRUCTION MANUAL Vibration Meter

SAS-563B Active Loop Antenna Operation Manual

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

Visit us at

INSTRUCTION MANUAL UTL260

Josephson Engineering, Inc. 329A Ingalls Street Santa Cruz, California Josephson Engineering Rev B

CLAMP-ON METER 670. User Manual

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

FlexProbe FLEXIBLE AC CURRENT PROBE. User Manual. FlexProbe ON OL 1000V CAT III 300A 3000A OFF

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

RU210. Dual Multi-UHF Wireless System. Item ref: UK, UK User Manual. Version 1.0

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

Safety Warnings Features Specifications Instrument Layout Operation Preparation AC Current Measurement How to Use Peak Hold Function How to Use The

14 Piece Slide Hammer and Puller Set

Instruction Manual for Digital Grounding Resistance Meter

200Amp AC Clamp Meter + NCV Model MA250

Planishing hammer stand For use with SKU Planishing hammer

Milliamp Calibrator. Model 434. General description. Calibrate with laboratory accuracy. All 4 to 20 ma loop functions

Digital Wireless Weather System

High Performance Microphone Splitter. Artcessories. User's Manual

Technical Documentation

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Operator s Manual. PP016 Passive Probe

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

AC/DC Current Probes Model MR411 Model MR521

Model 228 Current Leakage Tester INSTRUCTION MANUAL

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

DM-45 Digital Multimeter

INSTRUCTION MANUAL DL49

Owner s Manual DKW-3 HT. Wireless VHF Microphone System

Wilcom MODEL T336B CIRCUIT TEST SET. Operating Instructions

HQ-31 HQ-15 USER S GUIDE SINGLE CHANNEL 31 BAND 1/3 OCTAVE GRAPHIC EQUALIZER DUAL CHANNEL 15 BAND 2/3 OCTAVE GRAPHIC EQUALIZER

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

INSTRUCTION MANUAL LKG

Transcription:

Sound Meter Type 1 840015

Sound Meter Type 1-840015 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any form or by any means electronic, mechanical, or other means that do not yet exist or may be developed, including photocopying, recording, or any information storage and retrieval system without the express permission from Sper Scientific. TABLE OF CONTENTS INTRODUCTION...3 PANEL DESCRIPTION...3 OPERATING INSTRUCTIONS....4 MEASURE PROCEDURE...4 GENERAL APPLICATION SETTINGS...4 SIGNAL OUTPUT...5 PRECAUTIONS...5 CALIBRATION...5 BATTERY REPLACEMENT...6 FREQUENCY WEIGHTING (A & C) CHARACTERSITCS....6 TIME WEIGHTING (FAST & SLOW) CHARACTERSITCS...6 SPECIFICATIONS...7 WARRANTY....8 2

INTRODUCTION Your new instrument meets IEC61672 and ANSI S1.43 specifications for a Type 1 Sound Meter. It covers the 30 to 130 db range in both the A and C decibel frequency weighting scales, with 0.1 db resolution and an accuracy of ±1 db (63 Hz to 4 khz). This meter can be acoustically calibrated in compliance with OSHA, using Sper Scientific s Acoustical Calibrator 850016 (or equivalent). Features include a built-in calibration adjustment, easy to read LCD display, fast or slow time weightings, maximum hold function, low battery indicator, AC output and a reset button. CE compliant. Accessories include a windscreen, calibration tool, a carrying case, instruction manual and batteries. PANEL DESCRIPTION 1. Microphone (shown with windscreen) 1 2. Threaded Microphone Cap 3. Overload indicator 4. Display 2 5. Range selector 6. Power/Calibration selector 7. Time Weighting selector 8. Max Hold/Instant selector 9. Calibration Adjustment 10. Reset button 11. Frequency Weighting selector 12. Signal Output Terminal 3 4 5 6 7 8 9 10 11 12 3

OPERATING INSTRUCTIONS Measurement Procedures 1. Slide the POWER (6) selector to the I (on) position. 2. For general applications, slide the MAX HOLD / INSTANT (8) selector to the INSTANT position. 3. To freeze the displayed reading, slide the MAX HOLD / INSTANT (8) selector to the MAX HOLD position. 4. Press the RESET (10) button once to reset maximum hold to the current reading. 5. Slide the FREQUENCY WEIGHTING (11) selector to the A or C position. The A frequency weighting simulates human ear response. During an environmental sound level measurement, select the A weighting. The C weighting approximates a flat response. Typically, C is used to check the noise of machinery where the target sound level is already known. (See Frequency Weighting Characteristics, page 6.) 6. Slide the TIME WEIGHTING (7) selector to the F (fast) or S (slow) position. For general applications, select F which simulates the human ear s response time. The S setting is used to obtain an average of vibrating sound levels. 7. Find the appropriate measuring range using the RANGE (5) selector. If the OVERLOAD INDICATOR (3) appears in the upperleft display, slide the RANGE (5) selector to another setting. 8. Point the microphone at the sound source. The sound level will be displayed in decibels (db). 9. When finished, slide the POWER (6) selector to the O (off) position. General Application Settings 1. Set POWER / CALIBRATION (6) selector to I (on). 2. Set TIME WEIGHTING (7) to F. 3. Set MAX HOLD / INSTANT (8) selector to INSTANT. 4. Set FREQUENCY WEIGHTING (11) to A. 5. Set RANGE (5) selector to the appropriate range. 4

Signal Output The 3.5 mm diameter SIGNAL OUTPUT (12) terminal may be used to connect the unit to an external device (analyzer, recorder, controller, etc). Precautions Do not store or operate the unit in high temperatures or in a high humidity environment for long periods. Keep the microphone dry and avoid intense vibrations. CALIBRATION The meter s CALIBRATION ADJUSTMENT (9) is located on the front panel. The meter has a built-in internal standard of 94 db/1 KHz. Use the following procedures to calibrate the instrument before operating for the first time, or when the meter has not been in use for awhile. Internal Calibration 1. Slide the POWER (6) selector to the CAL. Position. 2. Slide the RANGE (5) selector to the 60 to 100 db position. 3. Slide the TIME WEIGHTING (7) selector to F. 4. Slide the FREQUENCY WEIGHTING (11) selector to A. 5. Use the calibration screw driver to turn the CALIBRATION ADJUSTMENT (9) until the display reads 94.0. External Calibration Use Sper Scientifics Acoustical Calibrator 850016 (or equivalent) to calibrate the unit, including the microphone, in compliance with OSHA. 1. Slide POWER (6) selector to the I (on). 2. Turn on the acoustical calibrator and place it onto the Sound Level Meter s MICROPHONE (1). 3. Slide the RANGE (5) selector to the 60 to 100 db position. 4. Slide the TIME WEIGHTING (7) selector to F. 5

5. Slide the FREQUENCY WEIGHTING (11) selector to A. 6. Use the calibration screw driver to turn the CALIBRATION ADJUSTMENT (9) until the display reads 94.0. BATTERY REPLACEMENT Replace the batteries when BAT is displayed. Accurate measurements may be made for several hours after the low battery indicator appears. Replace the batteries with 2 new heavy duty 9V batteries. FREQUENCY WEIGHTING (A & C) CHARACTERISTICS Frequency A Weighting C Weighting Tolerance (IEC 61672 Class 1) Tolerance (ANSI S1.43 Type 1) 31.5 Hz -39.4 db -3 db ± 2.0 db ± 1.5 db 63 Hz -26.2 db -0.8 db ± 1.5 db ± 1.0 db 125 Hz -16.1 db -0.2 db ± 1.5 db ± 1.0 db 250 Hz -8.6 db 0 db ± 1.4 db ± 1.0 db 500 Hz -3.2 db 0 db ± 1.4 db ± 1.0 db 1 khz 0 db 0 db ± 1.1 db ± 1.0 db 2 khz +1.2 db -0.2 db ± 1.6 db ± 1.0 db 4 khz +1 db -0.8 db ± 1.6 db ± 1.0 db 8 khz -1.1 db -3 db 12.5 khz -4.3 db -6.2 db 16 khz -6.6 db -8.5 db +2.1 db -3.1 db +3.0 db -6.0 db +3.5 db -17.0 db +1.5 db -6.0 db +3.0 db -6.0 db +3.0 db -no limit TIME WEIGHTING (FAST & SLOW) CHARACTERISTICS Time Weighting Max. response ref. continuous signal 6 Tolerance (IEC 61672 Type 1) F (Fast) -1.0 db + 1.0 db S (Slow) -4.1 db ± 1.0 db Tested with signal on 1000 Hz/94 db.

SPECIFICATIONS Display Function Measurement Range Resolution Accuracy (23 ± 5 ) Frequency Microphone Time weighting (Fast/Slow) Internal Calibration Output Signal Output Terminal Operating Env. Power Supply Power Consumption Dimension 18 mm (.0.7") LCD 3¼ digits db ( A and C Frequency weighting), Time weighting (Fast, Slow), Max. hold, AC Output 30-70 db, 60-100 db, and 90-130 db 40 db on each step, with overload indicator 0.1 db Frequency weighting meets ANSI S1.43 calibration input signal on 94 db 31.5 Hz to 8 khz), then the accuracy of "A" weighting is specified as: 31.5 Hz - ± 1.5 db, 63 Hz - ± 1 db 125 Hz - ± 1 db, 250 Hz - ± 1 db 500 Hz - ± 1 db, 06 khz - ± 1 db 2 khz - ± 1 db, 4 khz - ± 1 db 8 khz - + 1.5 db to - 3 db 12.5 khz - + 3dB to - 6dB 16 khz - + 3dB to - No Limit 31.5 Hz to 16 khz 1/2" standard size electric condenser microphone. Threaded microphone cap unscrews for microphone replacement. Fast (F): t = 125 ms Slow (S): t = 1000 ms Built-in internal calibration on front panel. Calibrated via internal 94 db/1khz square wave generator. AC 750 mvrms corresponding to each range step 3.5 mm diameter jack 0 to 50 C (32 to 122 F) and less than 80% RH DC 9V battery x 2PCs, 0006P, MN1604 (PP3) or equivalent, heavy duty or alkaline type Approximately DC 17mA Weight 16.1 oz (454 g) 10½" 3½" 1½" (267 89 38 mm) 7

WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of five (5) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will break the waterproof seal and void the warranty. To obtain warranty service, ship the unit postage prepaid to: SPER SCIENTIFIC LTD. 8281 East Evans Road, Suite #103 Scottsdale, AZ 85260 The defective unit must be accompanied by a description of the problem and your return address. Register your product online at www.sperwarranty.com within 10 days of purchase. 05/2015 8