Monitoring Solutions For Power Transformers, Reactors, Bushings and Instrument Transformers

Similar documents
Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

- Continuous real-time measurement and PD trend analysis; not multiplexed data collection.

RESIDUAL LIFE ASSESSMENT OF GENERATOR TRANSFORMERS IN OLD HYDRO POWER PLANTS

DEFERRING REPLACEMENT OF A 600 MVA, 345GRD Y/138GRD Y/ 13.8 kv SHELL TYPE WESTINGHOUSE AUTOTRANSFORMER

TECHIMP Power Transformer Monitoring

Hands-On Transformer Testing and Maintenance

TECHIMP Technologies & Services for Diagnostics and Monitoring of High Voltage Assets

Detecting and Managing Geomagnetically Induced Currents With Relays

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

Autotransformer Condition Monitoring Systems

Transformer Factory Testing

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

Specialists in HV and MV test and diagnostics. Testing in Substations

A New Approach for Transformer Bushing Monitoring. Emilio Morales Technical Application Specialist Qualitrol

Končar TMS - Bushing monitoring

Basic Principles and Operation of Transformer

ABB Power Products Service

CASE STUDY- FAULT IN POWER TRANSFORMER AT LOKTAK POWER STATION. - S K Mishra & S K Das NHPC Ltd O&M Division

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

The importance of partial discharge testing throughout the development and operation of power transformers

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

Primary Test Manager (PTM) Testing and management software for primary assets

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY

7. INSPECTION AND TEST PROCEDURES

Onsite Mobile AC High Voltage Test System

Field Measurement of Transmission Cable Dissipation Factor

Substation Preventive Maintenance

Improve asset protection and utilization

FIELD ELECTRICAL TESTING SPX TRANSFORMER SOLUTIONS, INC.

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser - OMICRON

EI HIGH VOLTAGE INSULATION TESTING POLICY

High Voltage Diagnostics Sarl 4, Rue de Lac CH 1897 Le Bouveret Switzerland

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

Welcome to the Session on. HT Distribution Network

Cholla T809 Condition Assessment Report Provided by students of Northern Arizona University with the support of Arizona Public Service

Maintenance & Diagnosis Strategies. for. High Voltage Substations

Automatic Transformer Winding Analyser

Mots clés Power Transformer, Condition Assessment, On-line Monitoring Internet. Par S. Tenbohlen *, T. Stirl, M. Rösner * * ALSTOM T&D, Germany

Fixed Series Compensation

CIGRE General Session, Paris 2014 Group Meeting SC B1 Insulated Cables, 27th August, 2014 Results of CAG Questionnaire

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

Transformer Protection Principles

CHAPTER 3 REVIEW OF POWER TRANSFORMER PROTECTION SCHEMES

Acoustic Emission in power transformers. Ajusco 15, Colonia Portales, Delegación Benito Juárez, C.P , México, D.F.

ECP HV INSULATION TESTING

Electrical Equipment Condition Assessment

Advanced, accurate and intelligent monitoring for your transformer

EFFECETIVE TRANSFORMER CONDITION ASSESSMENT

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Power transformer failure management on the Eskom distribution network in Limpopo

ECP HV INSULATION TESTING

TRANSFORMER SERVICES OUR KNOWLEDGE. YOUR EXPERTS.

Cable testing and diagnostics

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

Doble Solutions for Partial Discharge. Greg Topjian Solutions Manager

Understanding and Extracting Valuable Information from Basic and Advanced Power Transformer Testing Techniques

POWER TRANSFORMER. Failure Analysis & Troubleshooting. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

New Laboratory Stand and Teaching Program Transformer Monitoring System

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Application Note. Detection of Partial Discharge Using Ultrasound. Detection of Partial Discharge Using Ultrasound. Problem. iriss.

EE059: Transformer Operation, Maintenance, Diagnosis & Testing

Case Studies of Electric Power Equipment Diagnostics Using Acoustic Emission

1. Introduction. 3. Reasons for Investing in Dynamic Rating Dynamic rating is touted as a transformer management feature of value. Let us examine why.

On-line Partial Discharge Assessment and Monitoring of MV to EHV Cables

Transformer Protection

Transformer Testing & Maintenance Fundamentals. AVO Training Institute, Inc. 2018

MEDIUM & HIGH VOLTAGE

HVI - The World s Source For High Voltage Test Equipment

TRANSFORMER OPERATIONAL. Principles, Selection & Troubleshooting

IDAX 300 Insulation Diagnostic Analyzer. Dielectric Frequency Response Also known as: Frequency Domain Spectroscopy

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

UTILITY & SUBSTATION TESTING

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

MONTRANO. Continuous monitoring system for power transformers

Magnetization System of Magnetically Controlled Shunt Reactors

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

A Comparative Diagnosis Approach on Transformer s Insulating Oil Ming-Jong Lin

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

N S Sodha, Former Executive Director, POWERGRID Corpn, Gurgaon

Partial Discharge Theory, Modeling and Applications To Electrical Machines

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

Notes 1: Introduction to Distribution Systems

Transformers TRANS FORM ERS

MODEL INFORMATION. Model AWRMS TM 200. Automated Winding Resistance Measurement System

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

REPORT ON INVESTIGATION OF FAILURE OF 100 MVA, 220/66-33/11 KV POWER TRANSFORMER AT 220KV GEETA COLONY SUBSTATION OF DELHI TRANSCO LTD.

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

The Weidmann Conference The Aging of America s Transformers

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN

The Generators and Electric Motor Monitoring and Diagnostics Systems

Transformer Design: Economics & Reliability

Power Measurements and Basic Electrical Diagnostic Tests

For Medium Voltage Motors, Generators, Switchgear, Bus Duct and Cable Terminations

AccuSolar SOLAR POWERED SYSTEM

Transcription:

in cooperation with Monitoring Solutions For Power Transformers, Reactors, Bushings and Instrument Transformers BZ-MS/1 pazifik power Complete Transformer Monitoring System (TMS) ZVCM-1001 Bushing Monitoring System Hydrocal Dissolved Gas-In-Oil Monitoring System Continuous On-Line Transformer Health Monitor www.ppi.ph

Complete Transformer Monitoring System (TMS) Critical power transformers and reactors are the backbone of any power system. On-line monitoring enables asset managers to check the condition of critical equipment without the need for costly or difficult-to-schedule outages. When developing equipment problems can be detected before failures occur, maintenance and repairs can be performed on a condition-based, rather than time-based schedule, reducing maintenance costs and the risk of workmanship errors. The TMS combines all of our monitoring devices to provide continuous on-line monitoring of: Dissolved gas-in-oil levels for hydrogen, carbon monoxide, carbon dioxide, methane, ethane, ethylene, acetylene and moisture Bushing power factor, capacitance and leakage current Partial discharge inside the transformer and bushings Top oil and hot-spot temperatures Transformer aging and loss-of-life Also available with optional LTC monitoring. Our software provides alarm setpoints, graphical displays and algorithm-based alarms that maximize response without nuisance alarms. Our software engineers can design custom applications for any type of system. TMS continuous on-line monitoring system for Generator step up transformers SST and UAT transformers Wind Farm step up transformers HVDC transformers Autotransformers Substation power transformers Shunt and series reactors ZVCM continuous monitoring system for Condenser bushings Capacitance Coupled Voltage Transformers (CCVT s) Potential transformers EHV current transformers

ZVCM-1001 Bushing Monitoring System Made in the USA, the ZVCM system is a 6-channel, continuous monitoring system that can be connected on any type of condenser bushing as well as Capacitor Coupled Voltage Transformers (CCVT s), potential transformers or EHV current transformers. The ZVCM system allows the user to utilize a combination of analysis methods to provide fast and reliable determination of bushing condition. Other bushing monitoring systems only use the sum-ofthree-currents and adjacent analysis methods to identify changes to bushing condition and to calculate bushing power factor and capacitance values, but these methods are subject to substantial dynamic changes in power factor and capacitance values due to power system fluctuations in system voltage magnitudes and phase angles as well as transformer temperatures. For installations where more stable power factor and capacitance values are desired without data smoothing, the ZVCM-1001 can be configured for comparison or reference mode analysis and can also provide full leakage current magnitude and phase angle data for custom algorithm applications. ZVCM software employs proprietary algorithms that evaluate all available analysis modes to eliminate false alarms and ensure that bushing deterioration is detected early on. Hydrocal Dissolved Gas-In-Oil Monitoring System 1001+ 1003 1005 1008 100x-3/-2/-1 HYDROTAP The Hydrocal 1005 and 1008 use a microelectronic gas sensor for with vacuum headspace and near infrared technology to measure the other individual gas concentrations in oil. Moisture is measured with a thin film capacitive moisture sensor. The 1003 model use individual gas and moisture sensors to measure individual concentrations. The model 1001+ uses membrane technology and fuel cell gas sensor technology to measure a total composite gas level and moisture. Gas-in-oil analysis Moisture in oil analysis (O) Transformer monitoring inputs / outputs Offshore suitable 1) MS-7 2) Bushing Monitor ZVCM-1001 2) Monitoring of multiple transformers 4 (composite) 4 1) Special version with corrosively protection for the installation on offshore platforms 2) Extension packages (options) 2 4 2 4 2 4

Continuous On-Line Transformer Health Monitor The new PPI THM transformer health monitoring system utilizes multiple current, voltage, temperature, and pressure inputs in an integrated system to provide monitoring of up to 7 critical areas of transformer performance as well as control cooling operation.

Partial discharge monitor Partial discharge (PD) is an indication of excessive insulation stress. Increasing levels of PD can be a sign of movement inside the transformer or insulation damage. PD is monitored with inputs from the bushing test taps, filtered to collect the high frequency currents. Bushing monitor Condensor-type bushings can deteriorate with age and adverse service conditions. Evolving problems can be detected by increases in power factor and/or capacitance as well as imbalance current magnitude. Bushing power factor and capacitance is measured as well as imbalance current phase angle and magnitude, utilizing the power frequency current inputs from the bushing test taps. Our 12-channel THM enables the user to measure bushing parameters with multiple methods, minimizing the risk of false alarms. When inputs from CCVT s or potential transformers (PT s) are available, both the transformer bushings and the CCVT s or PT s can be monitored. Geomagnetic induced current (GIC) monitor Solar activity can have a dramatic impact on transmission line voltages which can cause damaging levels of DC offset and resulting damage to power transformers. Our system detects ground currents and power system harmonics to provide an early warning when GIC events occur. The monitor utilizes voltage inputs from the bushing sensors and ground current magnitude from a DC current transducer around the transformer tank ground. Leakage impedance monitor Transformer impedance is a key indicator of the physical clearances in the active part of the transformer and a change in impedance indicates a likely movement in the windings or other critical parts of the transformer. Our monitor utilizes voltages from the bushing sensors with load currents from the transformer s bushing CT s to regularly measure the transformer impedance. Thermal monitor and cooling controller Proper cooling operation is critical to prevent accelerated aging of transformer insulation. The system utilizes oil and ambient temperature RTD s and load current auxiliary CT s to determine oil and winding temperatures. These temperatures are used as inputs to switch transformer cooling stages on and off, as needed. Electronic oil level monitor The oil level in power transformers varies as a function of temperature and the temperature varies as a function of loading. Transformers are designed to operate safely over the normal range of thermal oil expansion, but when transformers are not properly filled, or when excessive leaks occur, energized parts can become exposed which can lead to internal flashover and catastrophic failure. Our float-less electronic oil level monitor uses oil pressure and temperature telemetry with tank geometry to accurately determine oil level and volume. The display can be mounted in easy to read locations unlike float-type gauges and the system can also detect high tank pressure conditions before the pressure relief device activates and spills oil, and other abnormal operating conditions such as a clogged breather. The monitor works on both conservator and gas-blanketed transformer designs. Dissolved Gas-in-oil Analysis (DGA) monitor DGA is the most widely used method to assess transformer condition. The standard DGA monitor for our system is the Hydrocal 1005 or 1008 on-line DGA monitor which utilize near-infrared measurement technology for measurement of dissolved hydrocarbon gasses plus hydrogen and moisture sensors. Other types of DGA monitors can be incorporated into the THM system, if needed. Central processing and communications The THM central processor routes all of the inputs to the monitoring modules and accepts the outputs from each module. It also stores the settings and algorithms and makes the calculations for all of the functions. The system has digital and analog outputs to provide alarms and streaming data. The required analog outputs must be specified, and are available in Ethernet or RS-485, using Modbus, DNP 3.0 or IEC61850 protocol over hardwire, fiber optic, wireless or cellular communications networks. TraMos Software Our TraMos software is a Windows-based database that can download, store and analyze data for all monitors on each transformer at each user s site. The program is compatible with Windows 95 through Windows 8 and provides tabular and graphical data interfaces for easy analysis of transformer condition. Special graphical functions are also included such as PD waveform location and Duval triangles for Hydrocal 1008 and similar system DGA analysis.

Efficient Electricity Solutions In a span of two decades, PPI Pazifik Power, Inc. successfully supplied the Philippine market a wide range of high quality innovative power and infrastructure equipment from the best manufacturers in Europe and from its own automated design concept to more than 200 customers who are at the forefront of the country s engines of industrial growth. Among PPI s most sought after power product lines are: Turnkey projects for Supply of Substations rated voltage of up to 230kV, Electricity Meters, Transformers, Switchgears, Disconnectors, Fault Indicators, Surge Arresters, Protective Relays, Diagnostic and Testing Equipments, Batteries, Harmonic Filters, UPS and AVR systems. PPI s seasoned Electrical Engineers deliver the unique support tailored fit for each customer s needs. PPI s cutting edge is its high product quality with an unparalleled delivery of after- service performance. DIAGNOSTIC AND TESTING EQUIPMENT Liona Automatic online PD detection and localization on XLPE cables PD Portable Partial Discharge localization and measurement on cable segments, joints and cable terminations Frida For testing of medium-voltage cables using VLF technology. Integrated tan delta (TD) measurements for cable diagnostics Insulating Fluids Tester Automatic measurement of dieletric strength, dissipation factor TD, specific resistance of insulating liquid PRS 600.3 Three-phase Portable Reference Standard and Power Quality Analyzer Hydrocal 1008 Multi-Gas-Oil Analysis System with Transformer Monitoring Functions Protection Relay Testing Automatic Relay Tester and Analyzing System for all types of Relays Digital Recorder System Combine the monitoring function of digital fault recorder with the features of power quality analyzer in a single system AFFILIATES 4/F South Park Plaza, Santiago Street Paseo de Magallanes Commercial Center 1232 Makati City, Metro Manila, Philippines Tel. : +63 2 511 88 88 Fax : +63 28 80 81 E-mail : info@ppi.ph www.ppi.ph/dlfiles/bz-tms.pdf