B 80.en. Single pole cam contactors for DC and AC applications C160, C162 Series. Connect - Contact - Control max. ED: 100% U 14,4V.

Similar documents
Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Connect - Contact - Control. DC Contactors 600V / 750V / 1000V. F 215e

Connect - Contact - Control. Connectors. Short Form Catalogue

Capacitor Switching Contactors

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Output of three-phase motors at 50 Hz and 400 V

Controls Contactors and Contactor Assemblies Special Applications

Description Basic devices with positive operation contacts

COMPONENTS. Power contactor Type BMS09.08 / BMS18.08

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Type: DILEM 10 G(24VDC) Article No.:

Safety switches with slotted hole lever

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Relay interface modules A

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

CI-tronic Soft start motor controller

RELOG. All-or-nothing Relay

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

XXXX e. X d.. X X X a

High-Speed DC Circuit-Breakers for Fixed Installation Type UR26, UR36, UR40 & UR46

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Characteristics 5 TeSys k contactors and reversing contactors

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

XXXX e. X d.. X X X a

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Limit switch set BOA-H DN PN 16/25 Material variant EN-GJS LT

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Position switches FM series

Electronic Circuit Breaker ESS1 for System SVS1

20 Series Power Relays

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

FM series position switches

Solid-State Switching Devices

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Electronic Circuit Breaker ESS1 for System SVS1

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Pluggable interface relays CR-U Universal relays

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Electronic timer CT-SDS.22

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Instruction manual for STA 1 sectional door operator

Rotary Measurement Technology Incremental Encoders

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Rotary Position Technology Incremental Encoders

Installation and Operating Instructions for Phase Demodulator Type _.2

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

Detecting Devices. 8/2 Introduction

COMPONENTS. High power contactor Type BMS09.15 / BMS18.15 BMS09.18 / BMS18.18

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Operating Manual MU2000K

Instruction manual for STA 1 sectional door operator

Directional valves Electrically operated Series 563, 565, 567. Brochure

CX-Series. Circuit Breaker

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Precision and High Reliability Thermostats Issue 3. Datasheet. Table of Contents

The frequency inverter continues to carry hazardous voltages for up to 5 minutes after it was switched off.

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Electronic timer CT-TGD.22

Three-phase monitoring relays CM-PFE and CM-PFE.2

Transcription:

Connect - Contact - Control Single pole cam contactors for DC and AC applications 10 7 120 M ED: % U 1,V Uiso. 0V 200A U 12V Art.:x-xxxx-xxxxxx Bj: xxwyy U 8,V 155 165 max. 60 B 80.en

2 Single pole C160/C162 Series cam contactors for DC and AC operation Schaltbau C160 and C162 Series cam contactors are supplied as single pole NO contactors. Cam switch elements are used as main contacts for DC and AC operation together with magnetic blowout for DC applications and auxiliary contacts. The contactors are of compact design, feature double-break main contacts, and are known for their reliabilty. Schaltbau cam contactors are used in large numbers in industrial and railway applications. Ordering code Example: Series + Version C160 K/ C160; cam switch element S06 K I th = 160 A, no blowout * 1 C160 M/ C160; cam switch element S06 M I th = 160 A, with blowout * 1 C160 A/ C160; cam switch element S06 A I th = 200 A, no blowout * 1 C160 C/ C160; cam switch element S06 C I th = 200 A, with blowout * 1 C162 E/ C162; cam switch element S07 E I th = 250 A, no blowout * 1 C162 G/ C162; cam switch element S07 G I th = 250 A, with blowout * 1 C162 N/ C162; cam switch element S07 G/N I th = 250 A, U n = 00 V, with blowout * 2 Coil voltage 12 / 2 / 6 / 8 / 60 / 80 / 96 / 110 Coil voltage in V DC Tolerance E +25%... -0% at T a = 70 C (special coil) N +20%... -0% at T a = 50 C Suppression V Varistor X none Aux. contacts (Number of, Configuration) H1 1 SPDT, S80 b Series (single auxiliary contact) P1 1 SPDT, S826 b Series (single auxiliary contact) B02 2 (auxiliary switch block) B20 2 (auxiliary switch block) C22 2, 2 (auxiliary switch block) C0 (auxiliary switch block) D2 2, (auxiliary switch block) D2, 2 (auxiliary switch block) Arc chamber/chute L Arc chamber for S06 M Arc chamber for S07 N Arc chamber for S07, with mounting screw P Arc chute for S07 G/N C160 C/ 2EV-H1-L Note: Presented in this catalogue are only stock items which can be supplied in short delivery time. Special variant If you need a special variant feel free to contact us. Maybe the type of contactor you are looking for is among our many special designs. If not, we also supply customized designs. In this case, however, minimum order quantities apply. Cam switch elements C160 Series Identification Cam switch element Conv. thermal current I th Magnetic blowout K S06 K 160 A none M S06 M 160 A existent A S06 A 200 A none C S06 C 200 A existent C162 Series Identification Cam switch element Conv. thermal current I th Magnetic blowout E S07 E 250 A none G S07 G 250 A existent N S07 G/N 250 A existent Arc chamber Identification used for cam switch element Mounting LK-S06 S06 A, S06 C, S06 M, S06 K slip on LK-S07 S07 E, S07 G slip on LK-S09 S07 E, S07 G slip on/screw on Arc chute C162 Series Auxiliary contacts Identification used for cam switch element Mounting LK-S07-DC S07 G/N slip on/screw on Auxiliary switch blocks for C160, C162 (see page 6) Unlike single auxiliary contacts, auxiliary switch blocks cannot be retrofitted. You must, therefore, order the corresponding version designed for use with auxiliary switch blocks beforehand, see ordering code. Single auxiliary contacts for C160, C162 (see page 7) Identification Ordering code Single aux. contact Auxiliary switch H1 HK-C160/C162-H1 1 SPDT, S80 b P1 HK-C160/C162-P1 1 SPDT, S826 b * 1 Arc chamber, detachable, see also table Cam switch elements * 2 Arc chute slip-on/screw-on, see also table Cam switch elements

Standards Contactors meet requirements for industrial applications to: IEC 6097-1 Low-voltage switchgear and controlgear - Part 1: General rules IEC 6097--1 Low-voltage switchgear and controlgear - Part -1: Contactors and motor starters - Electromechanical contactors and motor starters. Contactors meet requirements for railway applications to: IEC 60077-1, Railway applications - Electric equipment for rolling stock - Part 1: General service conditions and general rules. IEC 60077-2, Railway applications - Electric equipment for rolling stock - Part 2: Electrotechnical components; General rules. Specifications Series C160 C162 Type of voltage DC, AC DC, AC Main contacts, Number of, Configuration 1x 1x Nominal voltage U n 50 V / 750 V * 1 50 V / 750 V * 1 Rated insulation voltage U i to IEC 6097-1 60 V / 1,000 V * 1 60 V / 1,000 V * 1 Pollution degree Overvoltage category PD OV PD OV Conventional thermal current I th Cam switch elements * 2 S06 K, S06 M S06 A, S06 C S07 E, S07 G, S07 G/N Making capacity, resistive, T = 0 ms Cam switch elements * 2 S06 K, S06 M S06 A, S06 C S07 E, S07 G, S07 G/N 160 A 200 A 600 A 800 A 250 A 1,000 A Maximum breaking capacity see diagram, page 5 see diagram, page 5 Short-circuit current 900 A 1,00 A Switching off, no motor reversing circuits (only DC) only in one direction only in one direction Arc chute for DC operation (LK-S07-DC for S07 G/N) Blowout, magnetic (only DC) Arc chamber Main contacts: Material Main terminals Auxiliary contacts: Number of, Configuration Conv. thermal current I th Rated insulation voltage U i Terminals Magnetic drive: Rated control supply voltage U s Operating range of U s Coil power dissipation (T a =20 C / U s ) Coil temperature Suppression Terminals Degree of protection (IEC 60529) Mechanical endurance AgSnO 2 M8, tightening torque 6 Nm AgSnO 2 M10, tightening torque 10 Nm Single aux. contact or assembly with 2, or 6 aux. contacts * Single aux. contact 10 A, aux. contact assembly 6 A 00 V Screw-type with washer disc, or quick-connect 6. x 0.8 mm 12 / 2 / 8 / 60 / 80 / 96 / 110 V DC -0 %... +20 % at T a = 50 C * max. approx. 18 W 155 C at T a max and U s max Varistor Screw-type M IP00 5 million operating cycles Duty cycle % Mounting position Temperature Operating temperature Storage temperature preferably suspended upright -25 C... +50 C -0 C... +80 C Weight 2.0 kg 2.0 kg * 1 Special design * 2 See catalogue B0.en * See also Auxiliary contacts, page 6f. * Others on request

Mode of operation, Maximum breaking capacity DC operation: For voltages below 2 V or small loads at higher voltages cam switch elements without arc chamber and blowout are used. For voltages up to 0 V and corresponding high breaking capacity a cam switch element with magnetic blowout but without arc chamber is required. For voltages over 0 V an arc chamber should be used along with the cam switch element fitted with magnetic blowout. For use with 00 V or higher the S07 G/N Series cam switch element must be fitted with arc chute LK-S07-DC. Maximum breaking capacity: The breaking capacity of a switching element is a relative value which is influenced by a number of interactive factors like the kind of current (AC or DC), voltage, amperage, switching speed, frequency of operating cycles and design life. So if the maximum is required for one of those conditions, it means that all other conditions must be reduced correspondingly. The exact values can only be determined in several test series. As a guideline for choosing the right type of switching element that suits your application the below diagrams show the maximum breaking capacity of the switching element. AC operation: Depending on the required breaking capacity cam switch elements can be used with arc chambers or do without. Principally no magnetic blowouts are used with AC operation. A similar effect have the alternate current loops that form between the S-shaped stationary contacts and the movable contact bridge. For detailed information on the cam switch elements used in Schaltbau cam contactors refer to catalogue B0.en. For use under normal operating conditions these values are to be reduced for reasons of safety and in order to enhance the electrical endurance of the switching element. Based on our experience, it is, therefore, recommendable to limit the actual breaking capacity to 20% up to 60% of the maximum breaking capacity as shown in the diagrams. The value of the maximum breaking capacity reflects the capacity at which the arc is still being extinguished. The making capacity depends on both the welding strength of the contact material and the speed of actuation (bouncing). DC operation: AC operation: 1600 Maximum breaking capacity [A] 1800 1600 Maximum breaking capacity [A] 1500 1200 1 1200 0 0 = 1 ms 900 at 220 V 800 800 600 = ms 700 600 500 at 80 V 00 00 00 200 = 6 ms 200 at 0 V 200 00 00 0,9 0,8 0,7 0,6 0,5 0, 0,7 0,6 0,5 0, Switching voltage [V] cos Maximum breaking capacity of cam switch elements S06 and S07 fitted with permanent magnet blowouts and arc chamber. Maximum breaking capacity of cam switch elements S06 and S07 without blowout, with arc chamber. For use with 00 V or higher the S07 G/N Series cam switch element must be fitted with arc chute LK-S07-DC. Maximum breaking capacity: In order to make choosing the right cam switch element easier the diagrams also show values which exceed the maximum breaking capacity.

5 60 26 165 max. A Dimension diagram, Circuit diagram C160 and C162 (without auxiliary contact): Arc chamber optional slip-on/screw-on Coil terminal Thread M Area for mounting aux. contact assembly with 2, or 6 auxiliaryswitches, see also page 6 28 Main contact (1+) Tightening torque: C160: M8 = 6 Nm C162: M10 = 10 Nm ED: % U max : 1,V Uiso. 0V I th : 200A U Nenn : 12V 5,5 Art.:x-xxxx-xxxxxx Bj: xxwyy U min : 8,V Typ: C162 G/ 12NV-L Main contact (2) Tightening torque: C160: M8 = 6 Nm C162: M10 = 10 Nm 115 155 7 10 120 2 50 Maximum lenght without aux. contacts Area for mounting single aux. contact optional, here mountable, see also page 7 Clearance towards live or earthed parts Mounting borings: Ciruit diagram: 1 (+) A 2 ±0.2 Varistor (coil suppression, optional) 2 Safety instructions: Clearance towards plasma exit A P < rated power 70 mm P rated power mm 115 ±0.2 Ø5.8 or M5 Mounting position: Any, preferably upright with return spring pointing downwards. The user has to see to it that there are no exposed electrical parts of the contactor when live or under load. The way you mount the contactor has no less an impact on the rise of temperature and the insulation of the switching device. So please observe the clearance between live or earthed parts and comply with the safety regulations of the applicable standards. No liability will be accepted by Schaltbau in any circumstances for indirect damage resulting from clearances not being observed, devices not mounted properly, or products tampered with in any way. Reduced scale diagrams / dimensions in mm

6 Auxiliary switch block fitted with 2, or 6 switching elements For carrying out additional control and interlocking functions switch blocks are available fitted with two, four or six auxiliary contacts. How to order: Auxiliary switch blocks are pre-assembled at the factory and mounted to the contactor. That is why a certain switch block must be ordered together with the contactor and, unlike a single auxiliary contact, cannot be retrofitted at a later time. For exact ordering information please refer to Ordering code on page. Specifications of auxiliary switch block C160, C162 contactor with mounted auxiliary switch block C22 (comprising 2 and 2 contacts). Auxiliary switch Number of contacts, Material Conv. thermal current l th Rated insulation voltage U i Terminal Wire cross-section Momentary contact ( or ) 1... 6, hard silver (AgCu) 6 A 00 V M for 1... 2 wires 1.0 mm 2... 2.5 mm 2 Dimension and circuit diagrams Auxiliary switch blocks for Dimension diagrams: Circuit diagrams: Aux. contacts Length Circuit diagrams Auxiliary switch block D2 2 Identification B02 L=1 10 120 Identification B20 L=1 ED: % U max : 1,V Uiso. 0V I th : 250A U Nenn : 12V Art.:x-xxxx-xxxxxx Bj: xxwyy U min : 8,V Typ: C162 G/ 12NV-D2-P C160: M8 / C162: M10 Identification C22 L=6 6 5 8 7 50 L Identification C0 L=6 6 5 8 7 Identification D2 155 22 max. 112 L=85 6 5 8 7 10 9 12 11 Note: 1. With the auxiliary switch block mounted, the coil terminal of the contactor is shifted to the dummy switch in the middle of the switch block marked in the circuit diagram. 2. The individual switches as shown in the circuit diagrams are pre-assembled as an auxiliary switch block at the factory and mounted to the contactor. Other switch block versions are not possible in order to maintain the symmetry of power of the assembly. Identification D2 L=85 2 Reduced scale diagrams / dimensions in mm 1 6 5 8 7 10 9 12 11

7 Auxiliary contacts Single auxiliary contacts For carrying out additional control and interlocking functions an auxiliary contact will normally do. For this purpose our single auxiliary contact which can also be retrofitted is suited best. Features: Form Z circuitry SPDT with double-break contacts Snap-action switch with positive opening operation Solid contact bridge Wiping, self-cleaning contacts (only S826) Specifications of single auxiliary contact contactors with mounted snap-action switches as single auxiliary contact (left S80, right S826 Series). Auxiliary contact Number of contacts, Material Conventional thermal current l th Rated insulation voltage U i Terminal Wire cross-section Snap-action switch S80 (see cat. D20e) Snap-action switch S826 (see cat. D26e) 1, hard silver (AgCu) 10 A 00 V M for 1... 2 wires 0.75 mm 2... 2.5 mm 2 Dimension and circuit diagrams Single auxiliary contact for Dimension diagrams: Circuit diagram: 1 (+) 1 11 Single aux. contact Snap-action switch S80 b Series Single aux. contact Snap-action switch S826 b Series 2 1 12 10 120 M Single aux. contact Snap-action switch S80 b Series S826 b Series ED: % Uiso. 0V I th : 250A I Art.:x-xxxx-xxxxxx Bj: xxwyy Typ: C162 G/ 12NV-D2-P ED: % U max : 1,V Uiso. 0V I th : 250A U Nenn : 12V Art.:x-xxxx-xxxxxx Bj: xxwyy U min : 8,V Typ: C162 G/ 12NV-D2-P C160: M8 / C162: M10 C160: M8 / C162: M10 50 Scope of delivery: Single auxiliary contact comprising supporting bracket and snap-action switch together with spring plate (spring Ø: 0 mm) for retrofitting. See Ordering code, page 2. 178 max. 178 max. Mounting Single auxiliary contacts Mounting is easy and when done properly there is no need of adjusting the contactor anew. Pull off the existent slotted spring plate and remove the return spring. Push the supporting bracket together with the switching element over the cylinder of the magnetic drive and replace the return spring. While pretensioning the return spring a little, fit in the new spring plate together with the actuator angle. The operating position of the auxiliary switch can be adjusted either by moving the switch on its supporting bracket or by slightly bending of the actuator angle. For the exact ordering code of single auxiliary contacts refer to page 2. Reduced scale diagrams / dimensions in mm

8 RoHS 2002/95/EC Schaltbau GmbH manufactures in compliance with RoHS. Schaltbau GmbH has an environment management system that has been certified since 2002. Schaltbau GmbH has a quality management system that has been certified since 199. Electrical Components and Systems for Railway Engineering and Industrial Applications Connectors Connectors manufactured to industry standards Connectors to suit the special requirements of communications engineering (MIL connectors) Charging connectors for battery-powered machines and systems Connectors for railway engineering, including UIC connectors Special connectors to suit customer requirements Snap-action switches Snap-action switches with positive opening operation Snap-action switches with self-cleaning contacts Enabling switches Special switches to suit customer requirements Contactors Single and multi-pole DC contactors High-voltage AC/DC contactors Contactors for battery powered vehicles and power supplies Contactors for railway applications Terminal bolts and fuse holders DC emergency stop switches Special contactors to suit customer requirements Electrics for rolling stock Equipment for driver s cab Equipment for passenger use High-voltage switchgear High-voltage heaters High-voltage roof equipment Equipment for electric brakes Design and engineering of train electrics to customer requirements Schaltbau GmbH Klausenburger Strasse 6 81677 Munich Germany Phone +9 89 9 0 05-0 Fax +9 89 9 0 05-50 e-mail contact@schaltbau.de Internet www.schaltbau.com B1886/0711/1.0 Printed in Germany with compliments: We reserve the right to make technical alterations without prior notice. For updated product information visit www.schaltbau-gmbh.com. Issued November 2007