Doppler Radar for Heartbeat Rate and Heart Rate Variability Extraction

Similar documents
Touch-less Heartbeat Detection and Measurement-based Cardiopulmonary Modeling

Microwave Doppler Radar for Heart Beat Detection Versus Electrocardiogram: A Validation Approach

Microwave Doppler Radar for Heartbeat Detection Vs Electrocardiogram

Remote Monitoring of Heart and Respiration Rate Using a Wireless Microwave Sensor

Wireless Energy Transfer Using Zero Bias Schottky Diodes Rectenna Structures

Indoor Channel Measurements and Communications System Design at 60 GHz

Indoor MIMO Channel Sounding at 3.5 GHz

Enhancement of Directivity of an OAM Antenna by Using Fabry-Perot Cavity

SUBJECTIVE QUALITY OF SVC-CODED VIDEOS WITH DIFFERENT ERROR-PATTERNS CONCEALED USING SPATIAL SCALABILITY

Simulation Analysis of Wireless Channel Effect on IEEE n Physical Layer

BANDWIDTH WIDENING TECHNIQUES FOR DIRECTIVE ANTENNAS BASED ON PARTIALLY REFLECTING SURFACES

Reconfigurable antennas radiations using plasma Faraday cage

A 180 tunable analog phase shifter based on a single all-pass unit cell

A New Approach to Modeling the Impact of EMI on MOSFET DC Behavior

A design methodology for electrically small superdirective antenna arrays

Analysis of the Frequency Locking Region of Coupled Oscillators Applied to 1-D Antenna Arrays

3D MIMO Scheme for Broadcasting Future Digital TV in Single Frequency Networks

Dual Band Meander Line Antenna for Wireless LAN Communication

Antenna Ultra Wideband Enhancement by Non-Uniform Matching

NOVEL BICONICAL ANTENNA CONFIGURATION WITH DIRECTIVE RADIATION

Power- Supply Network Modeling

Gis-Based Monitoring Systems.

An improved topology for reconfigurable CPSS-based reflectarray cell,

INVESTIGATION ON EMI EFFECTS IN BANDGAP VOLTAGE REFERENCES

QPSK super-orthogonal space-time trellis codes with 3 and 4 transmit antennas

On the De-embedding of Small Value Millimeter-wave CMOS Inductor Measurements

QPSK-OFDM Carrier Aggregation using a single transmission chain

Small Array Design Using Parasitic Superdirective Antennas

STUDY OF RECONFIGURABLE MOSTLY DIGITAL RADIO FOR MANET

High efficiency low power rectifier design using zero bias schottky diodes

Optical component modelling and circuit simulation

Design of an Efficient Rectifier Circuit for RF Energy Harvesting System

A notched dielectric resonator antenna unit-cell for 60GHz passive repeater with endfire radiation

Concepts for teaching optoelectronic circuits and systems

RFID-BASED Prepaid Power Meter

Direct optical measurement of the RF electrical field for MRI

Coupled optoelectronic oscillators: design and performance comparison at 10 GHz and 30 GHz

UML based risk analysis - Application to a medical robot

Compound quantitative ultrasonic tomography of long bones using wavelets analysis

DUAL-BAND PRINTED DIPOLE ANTENNA ARRAY FOR AN EMERGENCY RESCUE SYSTEM BASED ON CELLULAR-PHONE LOCALIZATION

Enhanced spectral compression in nonlinear optical

Linear MMSE detection technique for MC-CDMA

Reconfigurable Patch Antenna Radiations Using Plasma Faraday Shield Effect

L-band compact printed quadrifilar helix antenna with Iso-Flux radiating pattern for stratospheric balloons telemetry

A 2.4GHz to 6GHz Active Balun in GaN Technology

The Galaxian Project : A 3D Interaction-Based Animation Engine

A Wideband Single-balanced Down-mixer for the 60 GHz Band in 65 nm CMOS

A 100MHz voltage to frequency converter

Wireless Bio- medical Sensor Network for Heartbeat and Respiration Detection

Towards Decentralized Computer Programming Shops and its place in Entrepreneurship Development

Electronic sensor for ph measurements in nanoliters

Dynamic Platform for Virtual Reality Applications

Position-Free Vital Sign Monitoring: Measurements and Processing

Hardware Simulator for MIMO Radio Channels: Design and Features of the Digital Block

A Passive Mixer for 60 GHz Applications in CMOS 65nm Technology

Floating Body and Hot Carrier Effects in Ultra-Thin Film SOI MOSFETs

High finesse Fabry-Perot cavity for a pulsed laser

Millimeter-Wave System for High Data Rate Indoor Communications

Study on a welfare robotic-type exoskeleton system for aged people s transportation.

A Low-Profile Cavity-Backed Dual-Polarized Spiral Antenna Array

Helical antenna characterization using the singularity expansion method

An High Performance Integrated Balun for 60 GHz Application in 65nm CMOS Technology

Two Dimensional Linear Phase Multiband Chebyshev FIR Filter

MODELING OF BUNDLE WITH RADIATED LOSSES FOR BCI TESTING

Long reach Quantum Dash based Transceivers using Dispersion induced by Passive Optical Filters

Signal and Noise scaling factors in digital holography

Miniaturized Passive Two-Path Notch Filter For UWB receiver

Foam Based Luneburg Lens Antenna at 60 GHz

On the Use of Vector Fitting and State-Space Modeling to Maximize the DC Power Collected by a Wireless Power Transfer System

New Structure for a Six-Port Reflectometer in Monolithic Microwave Integrated-Circuit Technology

Measures and influence of a BAW filter on Digital Radio-Communications Signals

Wireless Remote Monitoring of Packaged Passive Sensor for In-situ Pressure Measurement in Highly Reflective Environments

On the role of the N-N+ junction doping profile of a PIN diode on its turn-off transient behavior

Characterization of Few Mode Fibers by OLCI Technique

An image segmentation for the measurement of microstructures in ductile cast iron

Ironless Loudspeakers with Ferrofluid Seals

Passive UWB Beamforming: a N to M Compression Study

Improvement of The ADC Resolution Based on FPGA Implementation of Interpolating Algorithm International Journal of New Technology and Research

Slotted waveguide antenna with a near-field focused beam in one plane

Nonlinear Ultrasonic Damage Detection for Fatigue Crack Using Subharmonic Component

Performance of Frequency Estimators for real time display of high PRF pulsed fibered Lidar wind map

Wireless and Passive Nuclear Radiation Sensors

Towards Cognitive Radio Networks: Spectrum Utilization Measurements in Suburb Environment

Low-Cost Differential Front-End for Doppler Radar Vital Sign Monitoring

Gate and Substrate Currents in Deep Submicron MOSFETs

A technology shift for a fireworks controller

Benefits of fusion of high spatial and spectral resolutions images for urban mapping

Design of Cascode-Based Transconductance Amplifiers with Low-Gain PVT Variability and Gain Enhancement Using a Body-Biasing Technique

S-Parameter Measurements of High-Temperature Superconducting and Normal Conducting Microwave Circuits at Cryogenic Temperatures

PANEL MEASUREMENTS AT LOW FREQUENCIES ( 2000 Hz) IN WATER TANK

Stewardship of Cultural Heritage Data. In the shoes of a researcher.

Design Space Exploration of Optical Interfaces for Silicon Photonic Interconnects

Influence of ground reflections and loudspeaker directivity on measurements of in-situ sound absorption

Electrical model of an NMOS body biased structure in triple-well technology under photoelectric laser stimulation

A high PSRR Class-D audio amplifier IC based on a self-adjusting voltage reference

Augmented reality as an aid for the use of machine tools

analysis of noise origin in ultra stable resonators: Preliminary Results on Measurement bench

Low temperature CMOS-compatible JFET s

FeedNetBack-D Tools for underwater fleet communication

Equivalent circuit of a reconfigurable triple-slot reflectarray cell

Transcription:

Doppler Radar for Heartbeat Rate and Heart Rate Variability Extraction Dany Obeid, Sawsan Sadek, Gheorghe Zaharia, Ghaïs El Zein To cite this version: Dany Obeid, Sawsan Sadek, Gheorghe Zaharia, Ghaïs El Zein. Doppler Radar for Heartbeat Rate and Heart Rate Variability Extraction. E-Health and Bioengineering Conference (EHB), 2011, Nov 2011, Iasi, Romania. pp.1-4, 2011, <10.1109/EHB.2011.127061956>. <hal-00677878> HAL Id: hal-00677878 https://hal.archives-ouvertes.fr/hal-00677878 Submitted on 10 Mar 2012 HAL is a multi-disciplinary open access archive for the deposit and dissemination of scientific research documents, whether they are published or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers. L archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

Proceedings of the 3rd International Conference on E-Health and Bioengineering - EHB 2011, Doppler Radar for Heartbeat Rate and Heart Rate Variability Extraction D. Obeid 1, S. Sadek 2, G. Zaharia 3, and G. El Zein 3 1 Kaptalia Monitoring, Prisme 2 PIBS, Vannes, France, 2 Lebanese University, IUT, Saida, Lebanon, 3 UEB, IETR UMR CNRS 6164 - INSA, Rennes, France d.obeid@kaptalia.com Abstract-This paper presents a Doppler radar system used to detect the heartbeat signal from a d istance of one meter. The proposed system is based on using a vector network analyzer and two antennas. Measurements are performed at 16 GHz for different power levels between 0 and -25 dbm. Both heartbeat rate and heart rate variability are extracted and compared to a simultaneous ECG signal. Keywords: microwave systems Doppler effect noncontact detection cardiopulmonary activity heartbeat rate I. INTRODUCTION HE utility of microwave Doppler radar has increased for Tseveral applications. These include home health care applications, urgent conditions, and hospital needs. Affixed electrodes for traditional electrocardiograms are perturbing for long-duration home-monitoring, as well as for patients with conditions such as burn victims or newly born infants. In addition, a touch-less technique is necessary to detect life signs for people under rubble. Based on the Doppler theory, a target with a quasiperiodic movement reflects the transmitted signal with its phase modulated by the time-varying position of the target [1]. When the target is the person s chest, the reflected signal contains information about the chest displacement, due to heartbeat and respiration. However, while holding breath, the reflected signal depends on the chest displacement due to heartbeat alone. At rest, the variation of the chest displacement, caused by respiration, is between 4 and 12 mm [2], and the chest displacement due to heartbeat alone ranges between 0.2 and 0.5 mm [3]. The respiration rate corresponds to a frequency that varies between 0.1 and 0.3 Hz, while the heartbeat rate (HR) corresponds to a frequency that varies between 1 and 3 Hz [4]. Previous works tend to detect life signs [5, 6], respiration rates and heartbeat rates, using fixed frequency and fixed power of the transmitted signal. Direct-conversion Doppler radars, operating at 1.6 GHz and 2.4 GHz, have been integrated in 0.25 m CMOS and BiCMOS technologies [7]. Heart and respiration activities were detected using a modified Wireless Local Area Network PCMCIA card, and a module combining the transmitted and reflected signals [8]. Other systems operating in the Ka-Band were described in [9, 10] using a low power double-sideband transmission signal. Recently, a new study shows the possibility of detecting the presence of a person through a wall using Ultra-Wideband (UWB) radar [11]. Some experiments are performed for the detection of life signs using the 4 7 GHz band with 1 mw power and around 7 db antenna gain [12]. Another system operating at 10 GHz showed the ability to detect the heart and the respiration activity of a person behind a wall [13]. In this paper, a microwave system for heartbeat detection is proposed and validated with an electrocardiogram (ECG) signal. In addition to the installation simplicity, the proposed system has the ability of tuning both frequency and power. As the transmission of a signal with minimum power would be safer for both the patient and the medical staff, the proposed system helps determining the optimal frequency with the minimum transmitted power before the implementation process. Both heartbeat rate and Heart Rate Variability (HRV) are extracted and compared to the values obtained by the ECG. The rest of the paper is organized as follows. Section II presents the proposed system and shows the heartbeat signal detected vs the ECG signal. Section III shows the heartbeat signals detected by the proposed system at 16 GHz for several trasmitted powers. Section IV shows the results for the extraction of the heartbeat rate and the Heart Rate Variability (HRV) for both original and smoothed signals. Section V concludes the work. II. PROPOSED SYSTEM The proposed system is based on using a Vector Network Analyzer (VNA) (Agilent N5230A 4-Port) operating up to 20 GHz, and two horn antennas. Many features are available by using a VNA, such as the choice of the sweep time and the number of measurement points; therefore, the sampling rate. In addition, the frequency and the radiated power of the transmitted signal can be set and modified, and the time variation of the phase of the transmission coefficient S 21 can be measured. Fig. 1 describes the proposed system. More details describing this system can be found in [14-15]. The VNA generates a Continuous Wave (CW) signal at the desired frequency. The reflected signal off the person s chest is received by the antenna and fed back into the VNA, where the phase of S 21 is computed.

Proceedings of the 3rd International Conference on E-Health and Bioengineering - EHB 2011, Fig. 2. ECG signal (a) and the phase variations due to heartbeats detected at 16 GHz and -5 dbm: original signal (b), smoothed signal (c) This phase corresponds to the difference between the phases of the received and the transmitted signal. Measurements are performed at 16 GHz for several transmitted power: 0, -5, -10, -15, -20, and -25 dbm. microwave Doppler system is to measure the heartbeat rate; this corresponds to the average of the R-R intervals. III. HEARTBEAT ACTIVITY DETECTED AT DIFFERENT POWER LEVELS One useful contribution of our work is to decrease the transmitted power. This would be safer for both patient and medical staff. A smoothing technique is used in order to improve the SNR of the detected signals. The smoothing method is based on the Newton relation: ( a + b) n = n C a k n k k b n k =0 Fig. 1. Proposed system. Fig. 2 (a) shows the heartbeat signal detected using an ECG, while Fig. 2 (b) shows the heartbeat signal detected using 16 GHz operational frequency and -5 dbm transmitted power. These two signals are obtained simultaneously for the same patient. Fig. 2 (c) shows the heartbeat signal after applying a smoothing technique. Beside that the heartbeat signal detected with an ECG represents the electrical activity of the heart, the goal of the where n+1 (n = 2m where m is an positive integer number) is the length of the smoothing window. In this case, the phase p(i) is replaced by the weighted mean of the values: p(i-m) p(i+m). The weighting coefficients are given by the Newton binomial. Fig. shows the heartbeat signal detected by our contactless microwave system at 16 GHz and for several transmitted powers: 0 dbm (a), -5 dbm (b), -10 dbm (c), -15 dbm (d), 20 dbm (e), and -25 dbm (f). It can be noticed that as the power decreases, the signal-to-noise ratio (SNR) decreases. However, the peaks of the signals can still be detected. The effects of smoothing these signals are shown in Fig. 4.

Proceedings of the 3rd International Conference on E-Health and Bioengineering - EHB 2011, Fig. 3. Phase variations due to heartbeats detected at 16 GHz for the following tranmitted power: 0 dbm (a), -5 dbm (b), -10 dbm (c), -15 dbm (d),-20 dbm (e), and -25 dbm (f) Fig. 4. Phase variations due to heartbeat signals detected at 16 GHz for different transmitted powers after applying the smoothig technique IV. RESULTS: HEARTBEAT RATE AND HEART RATE VARIABILITY Related works tend to extract the average heartbeat rate for a specific window. This does not provide information about the variation of the HR in time, i.e. the HRV. Thus, a peak detection technique is required to track the peaks of the signal. In this work, both the heartbeat rate and the HRV of the signals detected at 16 GHz for different power levels are extracted. These values, for both original and smoothed signals, are compared to HR and the HRV obtained from the ECG reference signals. Fig. 5 presents the relative errors of the heartbeat rate for both original and smoothed signals compared to the reference ECG signal.

Proceedings of the 3rd International Conference on E-Health and Bioengineering - EHB 2011, ACKNOWLEDGMENT The authors acknowledge CEDRE (project reference number: 08SciF6/L4), AUF (project reference number: G3-110/1649), and Région Bretagne for partially funding this work. REFERENCES Fig. 5. Relative error of the HR: original and smoothed signals vs ECG For different transmitted power values between 0 and -25 dbm (with a down step of 5 db), the proposed system shows the possibility of detecting the heartbeat signal with a relative HR error between 0 and 3.5%. Smoothing the signals gives a relative error less than 1.5% for low power levels less than -15 dbm). Fig. 6. Relative error of the HRV: original and smoothed signals vs ECG signal On the other hand, as shown in Fig. 6, the relative HRV error varies between 2% and 21% while smoothing the signals improves this relative error to be between 1% and 6%. V. CONCLUSION AND PROSPECTIVES The proposed system shows the possibility to detect the heartbeat activity at 16 GHz for different power levels. The Doppler radar system is tested and compared to simultaneous electrocardiogram. The heartbeat activity is detected for transmitted power between 0 and -25 dbm and for a distance of 1 m between the person and the antennas. Both heartbeat rate and heart rate variability are extracted from the proposed system and compared to the reference signal. A high accuracy is observed for the average HR: its relative error varies between 0 and 3.5%, while it varies between 2% and 21% for HRV. A smoothing technique is applied as well to the orignal signals in order to improve the detection accuracy. The relative errors decrease to 0.5 1.5% for the HR, and to 1 6% fot the HRV. Our future work will focus on measuring the heartbeat activity for different operational frequencies and different transmitted power levels. [1] J. C. Lin, Microwave sensing of physiological movement and volume change: A review, Bioelectromagnetics (1992), vol. 13, pp. 557 565. [2] A. De Groote, M. Wantier, G. Cheron, M. Estenne, and M. Paiva, Chest wall motion during tidal breathing, Journal of Applied Physiology (1997), vol. 83, no. 5, pp. 1531-1537. [3] G. Ramachandran and M. Singh, Three-dimensional reconstruction of cardiac displacement patterns on the chest wall during the P, QRS, and T-segments of the ECG by laser speckle interferometry, Medical and Biological Engineering and Computing (1989), vol. 27, no. 5, pp. 525-530. [4] F. Mohammad-Zahed, F. Taghibakhsh and B. Kaminska, Contactless Heart Monitoring, 2007 IEEE, Session 33: Biomedical Signal Processing-I, pp. 583-585. [5] K. M. Chen, Y. Huang, J. Zhang, and A. Norman, Microwave lifedetection systems for searching human subjects under earthquake rubble and behind barrier, IEEE Trans. Biomed. Eng. Jan. 2000, vol. 47, no. 1, pp. 105 114. [6] A. D. Droitcour, V.M. Lubecke, J. Lin, and O. Boric-Lubecke, A microwave radio for Doppler radar sensing of vital signs, in IEEE MTT-S Int. Microw. Symp. Dig., May 2001, pp. 175 178. [7] A. D. Droitcour, O. Boric-Lubecke, V. M. Lubecke, and J. Lin, 0.25 μm CMOS and BiCMOS single chip direct conversion Doppler radars for remote sensing of vital signs, in IEEE Int. Solid-State Circuits Conf. Tech. Dig., Feb. 2002, pp. 348 349. [8] O. Boric-Lubecke, G. Awater, and V. M. Lubecke, Wireless LAN PC Card Sensing of Vital Signs, IEEE Topical Conference on Wireless Communication Technology (2003), pp. 206-207. [9] Y. Xiao, J. Lin, O. Boric-Lubecke, and V. M. Lubecke, A Ka-band low power Doppler radar system for remote detection of cardiopulmonary motion, presented at the 27th IEEE Annu. Eng. Med. Biol. Soc. Conf., Sep. 1 4, 2005. [10] Y. Xiao, J. Lin, O. Boric-Lubecke, and V. M. Lubecke, Frequency tuning technique for remote detection of heartbeat and respiration using low-power double-sideband transmission in Ka-band, IEEE Trans. Microw. Theory Tech., vol. 54, no. 5, pp. 2023 2032, May 2006. [11] V. M. Lubecke, O. B. Lubecke, A. H. Madsen, and A. E. Fathy, Through-the-wall radar life detection and monitoring, in IEEE International Microwave Symposium, 2007, pp. 769-772. [12] C. Li and J. Lin, Random body movement cancellation in doppler radar vital sign detection, IEEE Trans. on Microw. Theory Techn., vol. 56, pp. 3143-3152, 2008. [13] M. D Urso, G. Leone, and F. Soldovieri, A simple strategy for life signs detection via x-band experimental set-up, Progress in Electromagnetics Research C, vol. 9, pp. 119-129, 2009. [14] D. Obeid, S. Sadek, G. Zaharia, and G. El Zein, Non-Contact Heartbeat Detection at 2.4, 5.8 and 60 GHz: A Comparative Study, Microwave Opt. Technol. Lett., vol. 51, no. 3, pp. 666-669, March 2009. [15] D. Obeid, S. Sadek, G. Zaharia, and G. El Zein, Multitunable Microwave System for Touchless Heartbeat Detection and Heart Rate Variability Extraction, Microwave Opt. Technol. Lett., vol. 52, no. 1, pp. 192-198, Jan. 2010.