Model ABV Pressure Independent Automatic Balancing Valve. Application: Standard Construction: Performance: Configurations Available:

Similar documents
Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.

MR Modulo Adjustable Constant Airflow Regulator

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

NK / NL series. Rectangular VAV and CAV air volume control terminals


DIBD20, 40, 60 AND DIBD230, 430, 630 CURTAIN TYPE DYNAMIC FIRE DAMPERS

LINEAR DIFFUSERS AND BAR GRILLES

IBD23 CURTAIN TYPE STATIC FIRE DAMPERS 3 HOUR UL555 RATED FOR USE IN STATIC SYSTEMS

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

SECTION MECHANICAL IDENTIFICATION

SECTION MECHANICAL IDENTIFICATION

BC-SERIES Screw-Jack Pedestal for Creative Design. Specifications text. Menu. Page 1/7

Piping & Equipment Identification

RECTANGULAR CAV AND VAV AIR VOLUME CONTROL TERMINALS NK / NL SERIES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

DIBD2 and DIBD23 CURTAIN TYPE DYNAMIC FIRE DAMPERS 1 1 /2 AND 3 HOUR UL555 RATED FOR USE IN DYNAMIC AND STATIC SYSTEMS

SECTION MECHANICAL IDENTIFICATION

APPENDIX A, UMC STANDARD 6-5 STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

MP918B UL Listed Damper Actuator

HALDEMAN, INC. BRAND: RUSKIN. Fire Dampers. IBD20 Deduct 1/4 Inch. Model:

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

300 Series Pin & Barrel Type Continuous Stainless Steel Hinges

Installation Instructions: VIBRATION ISOLATION RAIL (CPR)

B. Samples: For color, letter style, and graphic representation required for each identification material and device.

AF-4 Grooved Flange Adapter

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

11-1/4 OD at Transition Point. Microcosmic. 4th and Brannan Street Platform Station Project. Elevation. Moto Ohtake 2014

Facility Services Subgroup Preface for Divisions 21` through 28

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Ford Water Meter Couplings & Accessories

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

MANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

Important Notices. Manway Lockout Point

STOP. V00029AC Rev. 04 READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID TOOL LIST. NET-ACCESS S-Type Network Cabinets

KCR-R CONSTANT AIR VOLUME FLOW REGULATOR

Technical Development Program

25 / 35 / 45. Rectangular Duct Connection System. Strong and Virtually Leak Free. Simple to install No additional sealing required

COLIBRI Ceiling. Square ceiling diffuser with discs for supply air QUICK FACTS

Flange Dimensions Class 125 Bronze Flange Dimensions Class 300 Bronze Flange Dimensions Class 150 Bronze Flange Dimensions

SECTION COMMON WORK RESULTS FOR HVAC

Product Guide Specification

GENERAL ISOMETRIC LAYOUT

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

INSTALLATION INSTRUCTIONS PART#:17A096400MSS\17A096400MA MODULAR GRILL GUARD FOR TOYOTA TACOMA 05-09

GRILLE AND REGISTER OPTIONS AND ACCESSORIES

Product Guide Specification

SECTION LOW PRESSURE DUCTWORK

Complete O.D. Machining in One Operation

FIRE STATION NO TH STREET NORTH ST. PETERSBURG, FL M-1 SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC SYMBOL LEGEND

EBTRON a measurable difference!

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

Index. Installation and Tools. Installation and Tools... Page

The EDGE Self-Sealing Round Duct System

REVISION #1. Section. fire alarm B. C. the hot. intent of. required. manufacturer. materials. C. Warranty

INTRODUCTION. EqunioxRoof.com. Pro Tip

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JEROME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450)

Features. Continuous Duty Cycle Actuators

ICC INDUSTRIAL CHIMNEY COMPANY INC. ST-JÉRÔME, QUÉBEC, CANADA, J7Y 4B7 TEL: (450) FAX: (450) INSTALLATION AND OPERATION INSTRUCTIONS

EBTRON a measurable difference!

Submittal Transmittal

Model No: TC10. Parts Information: Tyre Changer - Automatic

INSTALLATION & OPERATION MANUAL ML-37 / ML-38 / ML-39 MLR-37 / MLR-38 / MLR-39. Redefine your comfort zone.

SunTrackerTwo Preparation

CONTROL Room. Room product for Swegon s WISE system for demand-controlled ventilation. Quick facts Room control against temperature, CO 2

M1.0 MECHNANICAL FLOOR PLAN

Post & Rail. Includes: Crossbuck, 2-Rail, 3-Rail and 4-Rail POST SUPPORT OPTIONS

19-in. Mini-Rack Cabinet, Type 1

PARTS LIST MS 2892-D

LINEAR AIR GRILLE LF - 202/LF 212 / LF / LF ACCESSORIES

PORTA-FAB Cleanroom Wall Systems

SECTION IDENTIFICATION OF HVAC PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

HOW TO INSTALL HORIZONTAL ROD RAILING TREX SIGNATURE STANDARD

Infinity 20 Min. FIRE RATED DOORS WARNOCK HERSEY INFINITY - STANDARD RAISED - 20 MIN. RATING SOFTWOOD STILE

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

NUMBER OF HORIZONTALS REQUIRED FOR 2 ON CENTER SPACING.

SECTION SWINGING AUTOMATIC ENTRANCES

SYGEF Standard SYGEF Plus PVDF Flanges

COLIBRITM. Ceiling. Square ceiling diffuser with discs for supply air. Quick guide

Standard Product. Free-Stand Cabinets 19-in. Mini-Rack Cabinet, Components and Accessories

INSTALLATION INSTRUCTIONS GRILLE GUARD CHEVY TAHOE / AVALANCHE 1500/ SUBURBAN 1500 PART # /502795

Installation Instructions

C U S TO M I Z A B L E S P E C I F I C AT I O N C L I P S AVA I L A B L E AT M I D D L E AT L A N T I C.COM

Ceiling Tile Installations Part 1. Sheetrock Installations Part 2. WolfVision Support 2055 Sugarloaf Circle, Suite 125 Duluth, GA 30097

Contemporary Collection

MANUAL INSTALLATION. Linear Bar Grille LBP. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

General Information...SA1-SA4

Volumetric flow controller

Symphony II Adaptable Table System

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Wiring ducts Easily allows for organization, pulling and separation of cables

Transcription:

Application: Tag: Project: Location: Date: Engineer: Contractor: Architect: Submitted by: The ABV Automatic maintains a constant airflow volume in HVAC applications. The highly engineered damper blade is calibrated to automatically adjust to varying pressures using physics, not electricity, making the ABV truly pressure independent. R38089 The ABV can be used in any HVAC application where a precise volume of air (CFM) is required regardless of varying static pressures. The ABV can be used in both supply and exhaust applications. Standard Construction: FRAME: Reinforced UL 94 Thermoplastic Resins BLADE: Reinforced UL 94 Thermoplastic Resins BEARINGS: Hydraulic blade dampener for extremely quiet operation OUTER SEAL: Removable rubber gasket-type around circumference of damper SPRING: Stainless steel leaf type TEMPERATURE RANGE: 2 F (-4 C) to 10 F (6 C) ANTI-MICROBIAL AGENT: Steri-Balance infused into plastic ADAPTER: Quick-connect adapter ring for square ducts included Performance: AIRFLOW ADJUSTER: Hand-operated manual set-point adjuster (no tools needed) PRESSURE OPERATING RANGE: 0.2" WC (0 Pa) to 2.0" WC (498 Pa) UL STANDARD MET: Classified by UL to UL 2043 for heat and visible smoke release (UL File R38089) ACCURACY: +/- 10% of set CFM Airflow Range by Model Size: Model Diameter* Individual Manual Set Points Airflow Range (CFM)** ABV-4 4" (102) 20 2 to 130 ABV- " (127) 20 2 to 130 ABV-6 6" (12) 24 0 to 27 *Dimensions shown in inches, parentheses () indicate millimeters. **Note: Airflow range determined through +/- 10% of average airflow over 0.2" to 1" W.C. Configurations Available: Square/Rectangular to Round Transition (see page ) Grille Mount Box with Flange (see page 6) ABV & UL Fire Damper Assembly (see page 7) ABV & Wood Truss Ceiling Radiation Damper in Rated Boot Assembly (see pages 8-9) 1 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV - 080817 AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL 3376 727.441.261 www.airflowbalancing.com

PERFORMANCE DATA - Model ABV MODEL ABV-4 140.0 120.0 100.0 80.0 SET POINTS CFM 30 CFM 3 CFM 4 CFM 0 CFM 60 CFM 7 CFM 60.0 CFM 90 CFM 10 40.0 CFM 12 20.0 0.0 0.2 0.0 0.7 1.00 1.2 1.0 1.7 2.00 PRESSURE (inches/wg) MODEL ABV- 140.0 120.0 100.0 80.0 SET POINTS CFM 30 CFM 3 CFM 4 CFM 0 CFM 60 CFM 7 CFM 60.0 CFM 90 CFM 10 40.0 CFM 12 20.0 0.0 0.2 0.0 0.7 1.00 1.2 1.0 1.7 2.00 PRESSURE (inches/wg) CFM MODEL ABV-6 300.0 20.0 200.0 10.0 100.0 0.0 SET POINTS CFM 60 CFM 7 CFM 90 CFM 10 CFM 120 CFM 13 CFM 10 CFM 180 CFM 20 CFM 240 0.0 0.2 0.0 0.7 1.00 1.2 1.0 1.7 PRESSURE (inches/wg) Performance Notes: PL-1 PL-2 PL-4 10D min. PL-Z Units tested in accordance with AMCA 00-D-12 - Figure.1. D ± 0.02D Device Being Tested To Exhaust System & Flow Measuring Section 2 As part of our continuous improvement program, we reserve the right to make further improvements without notice. P s4 Submittal - Model ABV - 080817 AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL 3376 727.441.261 www.airflowbalancing.com

Dimensional Data: Model ABV Model Length (L)* Inner Diameter (ID)* Outer Diameter (OD)* Outer Diameter w/ Gasket (ODG)* Adapter Plate Height (H)* *Dimensions shown in inches, parentheses () indicate millimeters. **Weight shown in lbs., parentheses () indicate kilograms. Adapter Plate Width (W)* Weight** ABV-4 3.48" (88.) 3.37" (8.6) 3.66" (92.96) 4.1" (104.14) 3.90" (99.06) 4.00" (99.) 0.2 (.11) ABV- 3.72" (94.49) 3.37" (8.6) 4.81" (122.17).02" (127.1) 4.91" (124.8) 4.91" (124.8) 0.43 (.20) ABV-6.29" (134.27).29" (134.28).66" (143.76) 6.1" (14.94).91" (10.2).91" (10.2) 0.48 (.22) Calibration: Each ridge of the set-point adjustment indicator has been laboratory calibrated and tested in accordance with ANSI/AMCA 00-D-12 Figure.1 (see Figures 1 and 2) Each ridge is lab proven to deliver a flow rate within 10% of the set point Please consult factory for set-point ridges that are not labeled with a value NOTE: A ridge between two values may NOT necessarily be the average of the two. Adjustment: Adjusting of the ABV can be conveniently done by sliding the setpoint indicator on the face of the damper (see Figures 1 and 2) No tools needed to adjust the set-point of the ABV All lab-calibrated intervals represent the applicable CFM that will remain constant within +/- 10% of the set CFM Operation: All ABV models are easily reversible for use in both exhaust and supply applications (see Figures 3 and 4) NOTE: Airflow direction arrows on the product must be adhered to in order to assure proper operation All ABV models are supplied with a patent pending Quick Connect Adapter Ring that allows the ABV to be quickly and easily installed in the field into square duct All ABV models are also supplied with a removable rubber gaskettype seal around the circumference of the damper for a tight fit into rigid round duct NOTE: This gasket can be removed and switched to the opposite side for a supply application Figure 1 (4" and " set points shown) Figure 2 (6" set points shown) Figure 3 Figure 4 3 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV - 080817 AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL 3376 727.441.261 www.airflowbalancing.com

Suggested Specifications: Model ABV Furnish and install as shown on plans and/or schedules Model ABV Automatic by Automatic Airflow Balancing (AAB), Clearwater, FL. Unit shall respond to changes in duct pressure automatically without the need for power supply. All units shall incorporate a hand-operated manual set-point adjustment feature that facilitates field adjustment of flow rate set point without the use of tools, and allows adjustment while the automatic balancing valve is installed. All set points shall operate within ±10% of airflow set point. Individual set points shall be laboratory calibrated and verified through testing in accordance with AMCA 00-D-12. Each ABV shall be manufactured of reinforced thermoplastic resins and shall be classified per UL 2043 and must be labeled as such. Each unit shall be rated for use in air temperature ranging from 2 F to 10 F. All automatic balancing valves shall incorporate Steri-Balance antimicrobial agent to prevent organic growth. Each ABV shall utilize a hydraulic blade dampener to prohibit blade rattle. ABV valves shall be provided with a full circumference rubber gasket to provide tight seal when inserted in round duct, or for tight sealing when used in conjunction with an accompanying quick-connect adapter ring in square duct applications. Features & Benefits: 1. Oil-filled, hermetically sealed bearings for silent blade operation 2. Detachable adapter plate for square/ rectangular duct mounting (adapter plate can be moved to opposite side for supply applications) 3. Reversible design allows for use in supply or exhaust applications (NOTE: Arrow must coincide with direction of airflow) 4. Removable rubber gasket for tight seal in round rigid duct. Anti-microbial agent Steri-Balance infused into plastic 6. Tool-free set-point adjustment 7. 20-24 (depending on model) individual set-points 2 3 4 1 6" Model shown. 6 7 4 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV - 080817 AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL 3376 727.441.261 www.airflowbalancing.com

ABV - S/R Transition: All ABV models can be supplied with a square or rectangular transition (-S/R model). This transition will allow for inserting into square/rectangular duct or sleeve. The S/R transition can be removed and flipped to the other side of the ABV using the quick adapter plate (in some cases, tabs and screws will be used in place of adapter plate due to space constraints). Models: S/R Transitions: ABV-4-S/R 4" x 4" 8" x 4" 10" x 4" Other: x ABV--S/R 6" x 4" 8" x 6" 10" x 8" ABV-6-S/R 6" x 6" 8" x 8" 10" x 10" ABV-4-S/R (Legs Turned Out) ABV-4-S/R (Legs Turned In) 4" Model with 6" x 6" transition shown. 4" Model with 6" x 6" transition shown. 1" (2) 1" (2) As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV - 080817 AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL 3376 727.441.261 www.airflowbalancing.com

GM - Grille Mount Box: Model ABV All ABV models can be supplied with a flanged Grille Mount Box. This box will allow for the insertion of a standard depth grille (see grille options on next page). The ABV can be flipped around for supply applications by removing the Quick Adapter Plate, turning the ABV around (so that the set points are on the opposite side) and re-attaching the adapter plate. NOTE: Non-flanged Grille Boxes available. Please contact an AAB representative. Models: ABV-4 with Grille Mount Box ABV- with Grille Mount Box ABV-6 with Grille Mount Box Box Size (Grille Opening) " Width x " Height ABV-4 with Grille Mount Box.7" 1.0" DIM B DIM A DIM C ABV-Model Sleeve Size Dimension A Dimension B Dimension C ABV-4 6" x 6" (12 x 12) 7.20" (182.22) 3.44" (87.38).7" (146.0) ABV- 6" x 6" (12 x 12) 7.20" (182.22) 3.72" (94.49).7" (146.0) ABV-4 8" x 8" (203 x 203) 9.20" (233.68) 3.44" (87.38) 7.7" (196.8) ABV- 8" x 8" (203 x 203) 9.20" (233.68) 3.72" (94.49) 7.7" (196.8) ABV-6 8" x 8" (203 x 203) 9.20" (233.68).22" (1.9) 7.7" (196.8) ABV-4 10" x 10" (24 x 24) 11.20" (284.48) 3.44" (87.38) 9.7" (247.6) ABV- 10" x 10" (24 x 24) 11.20" (284.48) 3.72" (94.49) 9.7" (247.6) ABV-6 10" x 10" (24 x 24) 11.20" (284.48).22" (1.9) 9.7" (247.6) ABV-4 12" x 12" (30 x 30) 13.20" (33.28) 3.44" (87.38) 11.7" (298.4) ABV- 12" x 12" (30 x 30) 13.20" (33.28) 3.72" (94.49) 11.7" (298.4) ABV-6 12" x 12" (30 x 30) 13.20" (33.28).22" (1.9) 11.7" (298.4) Dimensions shown in inches, parentheses () indicate millimeters. Note: Common Grille/Sleeve sizes shown. Contact AAB for sizes not shown. 6 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV - 080817 AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL 3376 727.441.261 www.airflowbalancing.com

ABV and Fire Damper in UL Rated Assembly: All ABV models can be supplied with a UL rated fire damper as a UL Rated and Approved assembly. This assembly will include an ABV, flanged sleeve, fire damper and optional grille (see grille options within this submittal). The ABV can be flipped around for supply applications and re-secured using supplied tabs or adapter plate (depending on the size). This assembly must be installed per the fire damper manufacturer s installation instructions. NOTE: Non-flanged Grille Boxes available. Please contact an AAB representative. Models: ABV-4 with Fire Damper Assembly ABV- with Fire Damper Assembly ABV-6 with Fire Damper Assembly Options: ABV ABV-4 with UL Fire Damper Assembly: R38089 R8218 Fire Damper: Dynamic Fire Damper (standard for models 6"x 6" or larger) Horizontal* Vertical S/R Transition (tab or adapter plate depends on size) Static Fire Damper (standard for models 6 x 6 or smaller) Horizontal* Vertical.7" (19) Sleeve: Flanged (standard) No Flange DIM C Flanged Sleeve Slimline Fire Damper DIM A DIM B Special Notes: Grille (optional) *If installing horizontally, the ABV must be below the fire damper within the assembly. ABV-4 model shown above with 4" x 4" static fire damper and grille box. ABV-Model Sleeve Size Dimension A Dimension B Dimension C¹ ABV-4 4" x 4" (102 x 102).29" (134.37) SQ 8.8" (217.88) 3.9" (100.23) SQ ABV-4 6" x 4" (12 x 102) 7.29" (18.17) x.29" (134.37) 8.8" (217.88).9" (11.13) x 3.9" (100.23) ABV-4 6" x 6" (12 x 12) 7.29" (18.17) SQ 8.8" (217.88).9" (11.13) SQ ABV- 6" x 6" (12 x 12) 7.29" (18.17) SQ 8.86" (224.99).9" (11.13) SQ ABV-6 6" x 6" (12 x 12) 7.29" (18.17) SQ 10.36" (263.09).9" (11.13) SQ ABV-4 8" x 6" (203 x 12) 9.29" (23.97) x 7.29" (18.17) 8.8" (217.88) 7.9" (201.93) x.9" (11.13) ABV- 8" x 6" (203 x 12) 9.29" (23.97) x 7.29" (18.17) 8.86" (224.99) 7.9" (201.93) x.9" (11.13) ABV-6 8" x 6" (203 x 12) 9.29" (23.97) x 7.29" (18.17) 10.36" (263.09) 7.9" (201.93) x.9" (11.13) ABV-4 8" x 8" (203 x 203) 9.29" (23.97) SQ 8.8" (217.88) 7.9" (201.93) SQ ABV- 8" x 8" (203 x 203) 9.29" (23.97) SQ 8.86" (224.99) 7.9" (201.93) SQ ABV-6 8" x 8" (203 x 203) 9.29" (23.97) SQ 10.36" (263.09) 7.9" (201.93) SQ Dimensions shown in inches, parentheses () indicate millimeters. NOTE: Common Sleeve sizes shown. Contact AAB for sizes not shown. ¹Opening for ABV and Fire Damper assembly should be framed larger than these listed dimensions (see manufacturer s installation instructions). 7 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV - 080817 AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL 3376 727.441.261 www.airflowbalancing.com

ABV and Wood Truss Ceiling Radiation in Rated Boot Assembly: All ABV models can be supplied with a UL 263 rated wood truss ceiling radiation damper and boot assembly. This assembly will include an ABV in the supply or exhaust orientation, un-insulated 90 degree or straight sheet metal boot, Warnock-Hersey approved wood truss ceiling radiation damper and optional grille (see grille options within this submittal). The ABV is bi-directional and can always be flipped around from supply to exhaust applications, or vice versa, and re-secured within the neck of the sheet metal boot. See next page for a 90 degree insulated boot assembly. This assembly must be installed per the ceiling radiation damper manufacturer s installation instructions. NOTE: Wood truss CRD boots typically supplies with flanges for boot rail installation. Non-flanged wood truss CRD boots are available. Please contact AAB representative. ABV Models: ABV-4 ABV- ABV-6 Application: Supply Exhaust WT Ceiling Radiation Damper Boot Models: See NCA Manufacturing (www.ncamfg.com) Submittals for dimensional information and approved ceiling designs on below models: CDH-S/R-90-F (90 degree un-insulated boot with boot rail flanges) CDH-S/R-90 (90 degree un-insulated boot without boot rail flanges) CDH-S/R-ST-F (Straight un-insulated boot with boot rail flanges) CDH-S/R-ST (Straight un-insulated boot without boot rail flanges) ABV-6 with Wood Truss Ceiling Radiation Damper Boot Assembly: Boot/Damper Size: " width x " height x " diameter NOTE: Width and Height dimensions are the grille opening and can be interchanged (i.e. WxH is same as HxW). NOTE: 10x6x6 CDH-S/R-90-F with 6" ABV-6 Shown in the supply orientation. If in the exhaust orientation, the setpoint ridge will be accessible from grille opening. CDH-S/R-ST- F D 1/8" (3) 2" CDH-S/R-90-F Varies - See Submittal 2" (1) D-1/8" (3) Varies - See Submittal Varies - See Submittal 6" 2-1/2" (64) 1/2" (13) 2-½" 1" (2) LISTED SIZE W x H 1" (2) 1" LISTED SIZE W x H ½" 8 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV - 080817 AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL 3376 727.441.261 www.airflowbalancing.com

ABV and Wood Truss Ceiling Radiation in Rated Boot Assembly: All ABV models can be supplied with a UL 263 rated wood truss ceiling radiation damper and boot assembly. This assembly will include an ABV in the supply or exhaust orientation, insulated 90 degree sheet metal boot, Warnock-Hersey approved wood truss ceiling radiation damper and optional grille (see grille options within this submittal). The ABV is bi-directional and can always be flipped around from supply to exhaust applications, or vice versa, and re-secured within the neck of the sheet metal boot. See previous page for a 90 degree un-insulated boot assembly. This assembly must be installed per the ceiling radiation damper manufacturer s installation instructions. NOTE: This insulated wood truss ceiling radiation damper damper boot will be supplied with flanges for boot rail installation only. ABV Models: ABV-4 ABV- ABV-6 Application: Supply Exhaust WT Ceiling Radiation Damper Boot Models: See NCA Manufacturing (www.ncamfg.com) Submittals for dimensional information and approved ceiling designs on below models: ABV-6 with Insulated Wood Truss Ceiling Radiation Damper Boot Assembly: CDH-S/R-90-IB (90 degree insulated boot with boot rail flanges) Boot/Damper Size: " width x " height x " diameter NOTE: Width and Height dimensions are the grille opening and can be interchanged (i.e. WxH is same as HxW). 3-1/2" (89) CDH-S/R-90-I B LISTED SIZE + 3" (76) NOTE: 6x10x6 CDH-S/R-90-IB with 6 ABV-6 Shown in the supply orientation. If in the exhaust orientation, the set-point ridge will be accessible from grille opening. D-1/8" (3) Varies - See Submittal 2-1/2" (64) W H 1/2" (13) 1" (2) LISTED SIZE W x H 1" (2) 9 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV - 080817 AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL 3376 727.441.261 www.airflowbalancing.com

Grille Options: MODEL: RH-1 (Return Grille - Surface Mount - Roll Formed Aluminum) GASKET Listed Size Listed Size - 3 8 GASKET 8 Listed Size + 2 Face View (RH-1 Model) MODEL: SRH-1 (Return Grille - Surface Mount - Roll Formed Steel) Listed Size*- 3 8 Ø 3 Mounting Holes 16 (Countersunk) 1 1 2 Listed Size*+ 2 8 Face View (SRH-1 Model) MODEL: CC-1 (Sidewall/Ceiling Return Grille - Surface Mount - Extruded Aluminum) Duct Size = Listed Size Listed Size - 1 4 1 3 8 Listed Size +1 3 4 ½ x ½ x ½ Cube Core ½ x ½ x ½ Cube Core 8 Face View MODEL: RHE-1 (Return Grille - Surface Mount - Extruded Aluminum) Listed Size*- 1 4 Listed Size*+ 2 Mounting Holes (Countersunk) 8 Face View (RHE-1 Model) 04 Clear Anondized 10 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV - 080817 AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL 3376 727.441.261 www.airflowbalancing.com

Grille Options: Listed Size Listed Size - 1 2 1 7 8 Mounting Holes 3/16 Diameter (Countersunk) Listed Size + 2 9 16 Face View Listed Size Listed Size - 1 2 1 7 8 Mounting Holes 3/16 Diameter (Countersunk) Listed Size + 2 9 16 Face View Listed Size Listed Size - 1 2 Listed Size + 2 9 16 1 3 4 Mounting Holes 3/16 Diameter (Countersunk) Front View (H4002-1 Model) Horizontal Blades Listed Size Listed Size - 1 2 Listed Size + 2 9 16 1 3 4 Mounting Holes 3/16 Diameter (Countersunk) Front View (V4002-1 Model) Vertical Blades 11 As part of our continuous improvement program, we reserve the right to make further improvements without notice. Submittal - Model ABV - 080817 AUTOMATIC AIRFLOW BALANCING 198 CARROLL ST. CLEARWATER, FL 3376 727.441.261 www.airflowbalancing.com