Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

Similar documents
Power IT LV Active Filters PQFA - PQFL - PQFT

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Active Harmonic Filters IPC150 AHF Series

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Power IT LV Active Filter PQFM. Installation, operation and maintenance instructions ABB

APPLICATIONS. AFQ Active Multi-Function Filter. AFQ solves thousands of problems in countless types of installations, in particular the following:

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Integra 1560 and 1580 Digital Transducer Systems

Power Meter Series PM3200 Functions and characteristics

Introduction: TAS PowerTek Ltd. MAVROS

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

ULTRA RAPID POWER QUALITY ANALYZER

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

Instructions Manual LV Active Filter PQFL

Active Harmonic Filter

ABB n.v. Power Quality Products, October 2014

LV Compensation & Filtering Products

Liebert AF2 Next Generation Active Harmonic Filter. Power Protection for Business-Critical Continuity TM

Power Processor - Series 700F 10KVA to 150KVA

Instructions Manual LV Active Filter PQFT

S11 Adjustable Speed Drive Engineering Specification

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Gutor PxW AC UPS Designed for North American Market

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Installation and Operating Instructions. Power Factor Controllers RVT

Power Factor Controller RVT Installation and Operating Instructions

Side view View from below Rear view

Data Sheet. RISH Master Record %THD

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

Metering Devices, Protective Relays, Software and Connectivity

Phoenix DX Clean Power (18 Pulse) AC Drive

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

TOSHIBA International Corp

OBICON. Perfect Harmony. Short overview. ROBICON Perfect Harmony. System Overview. The Topology. The System. ProToPS. Motors.

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

Multimeter 500CVD21 RTU500 series

Types VIS and CRE. A e. Compliance with Standards. Uses. Features

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Meduim Voltage Drives

RELIABLE SOLUTIONS in POWER ELECTRONICS VRST SERIES. Power Management Instruments ELECTRONIC STABILIZER FROM PMI & OES GROUP COMPANIES SUD

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Technical Data Sheets

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

R&D TECHNICAL SPECIFI

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

NETWORK ANALYZERS Analyzers

Installation and Operating Instructions

Active Harmonic Filter (AHF)

AccuSine PCS Active Harmonic Filter. Cruise through rough waves in your electrical network

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Three phase sine wave inverter - 3KVA to 30KVA

HAWK5000 Operators Manual

Digital Multifunction Instrument - Rish Master 3440

Fluke 40/41 Power Harmonics Analysers

Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters.

Est Static Frequency Converter. SFX 10kVA - 10MVA

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

VF-nC1 Adjustable Speed Drive Engineering Specification

N. TEST TEST DESCRIPTION

MultiCube Multi-Function Electricity Meter. Installation and Operation

Electrical Submersible Pumping Systems

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

Technical Data Sheet AMIK 300 / 301

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

Introduction DIN rail mounted electricity meters

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

AF91 Adjustable Frequency Drives Series B

E3 Adjustable Speed Drive Engineering Specification

AccuSine PCS Active Harmonic Filter. Cruising through rough waves in your electrical network

ADJUSTABLE SPEED DRIVES FS1

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

FCR 06, FCR 12. Power factor correction controller. User and service manual

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

Installation and Operating Instructions. Power Factor Controller RVT-D

Variable Frequency Drives

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

Transcription:

Power IT LV Active Filters PQFI PQFM PQFK The ABB comprehensive solution for active filtering of harmonics

Harmonics and Power Quality Power Quality relates to the amplitude, frequency and distortion of the supply system. While the amplitude and frequency of the supply is largely controlled by the utility, the distortion of the wave (voltage or ) is attributed to the user (of the power) or the loads. Linear loads like an induction motor, an incandescent bulb, resistive heating or a capacitor bank draw a which follows the wave shape of the supplied voltage (sinusoidal). On the other hand, most of the common loads nowadays are non-linear, like VSDs (Variable Speed Drives), rectifiers, UPS-systems, computers, TV sets, energy efficient (fluorescent) lamps, photocopiers etc. These loads draw a from the source which does not follow the voltage wave shape and hence introduce distortion. The distortion is introduced by harmonics generated by the non-linear devices. These harmonics are a growing problem for both electricity suppliers and users. Harmonics can lead to serious problems: overheating of cables, motors and transformers damage to sensitive equipment tripping of circuit breakers blowing of fuses premature ageing of the installation capacitor overloading and failures high in neutral conductors excitation of network resonance Typical VSD 8 UNFILTERED LINE CURRENT (1A/div) UNFILTERED LINE CURRENT (% FUNDAMENTAL) 25% 2% 15% 1% 5% -8 TIME (5ms/div) % 2 5 8 11 14 17 2 23 26 29 32 35 38 41 44 47 5 HARMONIC ORDER The ABB Solution: PQF Power Quality Filter The ABB Power Quality Filter offers unprecedented ability to clean the network from harmonics. The PQF actively eliminates the harmonics present in the supply system in a controlled way. It is insensitive to large network impedance changes due to change in network topology like paralleling of sources, or switching between mains supply and generator operation. The PQF monitors the line in real time and processes the measured harmonics as digital signals in a high-power multi-dsp (Digital Signal Processor) based system. The digital controller generates Pulse Width Modulated (PWM) signals that drive IGBT power modules which through line reactors inject harmonic s in the network with exactly the opposite phase to the components that are to be filtered. The PQF also offers communication facilities with the customer s existing communication network. This feature which uses Modbus RTU, allows the PQF to be easily monitored and controlled from a remote location. The Modbus communication feature can be used by means of an RS-232 to RS-485 converter (optional). Principle of operation Fundamental only CT Clean feeder Load Active filter PQF Load = + Harmonics only Harmonics 2

PQF : The Ultimate Step in Filtering Efficiency The PQF offers the perfect solution for harmonic filtration. The net effect of a PQF is a clean sine wave due to the elimination of the harmonic content of a distorted waveform. In other words, the feeding transformer carries a harmonic free and consequently there is no network pollution introduced by the filtered load. The closed loop control offers an added advantage of accurate filtering without any need of special measuring devices. The digital controller gives increased flexibility and accuracy in filtering. The IGBT based power units of the PQF are optimally designed to suit the requirement for each type of PQF. ABB s vast field experience with varied load types gives us added advantage for the best possible design of the PQF. Use of optical fibres ensures complete electrical isolation between the power and control circuits. The PQF-Manager allows a wide range of choice for measurement of various network parameters, programming and settings of the PQF. Our PQFs are designed to meet the limitations on harmonic pollution as per various international guidelines like G 5/4, IEEE 519 etc. The complete range of PQF is CE marked. UL recognition and CSA approval are pending for the PQFs up to 6V. PQFs up to 6V will be offered either in CE marked or UL recognised-csa approved execution. ISO 91 and ISO 141 certifications ensure best quality in the manufacturing process. Line - Filter running 8 FILTERED LINE CURRENT (1A/div) FILTERED LINE CURRENT (% FUNDAMENTAL) 25% 2% 15% 1% 5% -8 TIME (5ms/div) % 2 5 8 11 14 17 2 23 26 29 32 35 38 41 44 47 5 HARMONIC ORDER Advantages of the PQF Filters up to 2 harmonics simultaneously Filters up to the 5th harmonic Harmonic attenuation factor better than 97% Fulfilment of International Guidelines like G5/4, IEEE 519, etc Filters with closed loop control for best accuracy Is not overloadable Has a programmable filtering strategy and free choice of harmonics selection Fault and event logging with real time stamp Direct connection up to 69V Top or bottom cable entry (optional for PQFI) Easy commissioning Auto-detection of CT Polarity May filter without generation of reactive power May generate reactive power and control power factor May balance the load across the phases Has programmable task priorities Does not require detailed network analysis Does not require special CTs Is easy to extend on site Comes factory tested Auto-adaptation to network impedance changes Optical fibre isolation between power and control stages Programmable stand-by and re-start functions Programmable digital I/O interface Modbus RTU communication compatible Two sets of compensation parameters for different load type compensation. 3

PQFI: the ABB solution for active filtering of harmonics for heavy industrial loads (to be available soon) Power electronics PWM converter with DC capacitors IGBT technology PQF-Manager Versatile user interface Digital Control (DSP) Programmable filtering characteristics Perfect multi-tuning to selected harmonics Not overloadable Programmable power factor correction Load balancing feature Zero-Q filtering capability Programmable task priorities Forced air cooling Breaker and auxiliaries Description W D H PQFI The PQFI can consist of one master and up to seven slave units mounted in cubicles together with auxiliary apparatus and wiring to form a factory assembled and tested system. The standard PQFI is offered in IP21 execution. The dimensions of a single PQFI unit are 8 x 6 x 215 mm (W x D x H). Large systems consisting of several PQFI units (master + slaves) are mounted on a base frame for a total height of 225 mm. The PQFI filter is modular in design. On-site extensions are easily made by adding slave units (maximum seven) in parallel to the master unit. The PQFI is suitable for direct connection up to 69V and is offered in two voltage groups (from 28V to 48V and 48V to 69V). Each voltage group includes units of different ratings. Intermixing of units of both equal and unequal rating is allowed in the same voltage group. Typical applications Oil and gas industry Steel industry Water industry Cement industry Automotive industry Process plants Pulp and paper 4

Typical result of PQFI application (drives) 35 Harmonic without PQF 35 Harmonic with PQF 3 3 25 25 % FUND 2 15 1 % FUND 2 15 1 5 5 THD H5 H1 H15 H2 H25 HARMONIC ORDER THD H5 H1 H15 H2 H25 HARMONIC ORDER PQFI Technical specifications RMS per unit (5 or 6 Hz) CT requirement Modularity Physical mounting Tolerance Harmonics to filter Degree of filtering Harmonic attenuation factor (I H (source)/i H (load) Reactive Power Communication Programming Response time Load balancing Active filter for three-phase network with or without neutral for filtering of non zero-sequence harmonics and reactive power compensation including load balancing. 28V U 48V 48V<U 69V 25 A 18 A* 45 A 32 A* 3 CTs required (class 1. or better), 15 VA, 5 Amps secondary rating. Up to 8 units (intermixing of units of both equal and unequal rating is allowed in the same voltage group). One unit per panel. +/- 1% in voltage. +/- 5% in frequency. 2 individual harmonics selectable from 2 nd to 5 th order. Individually programmable per harmonic in absolute terms. Better than 97%. Power factor programmable from.6 (inductive) to.6 (capacitive). Using Modbus RTU. Through RS-232 Port with dedicated software (PQF-Link). Using PQF-Manager. Using optional PQF-Link software and PC (not provided). 4 ms (1-9% filtering). Programmable load balancing. Active Power Protection degree Cubicle dimension Weight (unpacked) Color Installation Environment Ambient temperature Humidity Main options * If the nominal system voltage is higher than 6V (U>6V) the rating of PQFI units in this voltage range may be derated automatically depending on the operating temperature. Losses less than 5% of the rated power per unit. IP21 (IP2 open door). For higher protection degree, please consult us. 8 x 6 x 215 mm (W x D x H). Appr. 62 kg (45A/32A) or 525 kg (25A/18A) per unit. RAL 732 (beige). Other colors on request. Floor fixation, lifting lugs provided, cable entry from bottom. Indoor installation in clean environment up to 1 m altitude. For higher altitudes, please consult us for suitable derating. -5 C to +4 C. For higher ambient temperature, please consult us for suitable derating. Maximum 95% RH; non-condensing. Base frame (1 mm). PQF-Link software. RS-232 - RS-485 converter. Modem connection. Printer (RS-232 based). MCB position status lamps. Space heaters. Cubicle for top cable entry. IP41 protection degree. Surge arresters. Temperature probes. Connection diagram L3 L2 L1 x/5a x/5a x/5a SUPPLY LOAD(S) CT1 CT2 CT3 L1 L2 L3 PQFI P.E. Modbus communication Electrical digital I/O interface 5

PQFM: the ABB solution for active filtering of harmonics for industrial loads of lower capacity Contactor and fuses PQF-Manager Versatile user interface Digital Control (DSP) Programmable filtering characteristics Perfect multi-tuning to selected harmonics Not overloadable Programmable power factor correction Load balancing feature Zero-Q filtering capability Programmable task priorities Power electronics PWM converter with DC capacitors IGBT technology Forced air cooling Top or bottom cable entry Description W D H PQFM The PQFM can consist of one master and up to seven slave units mounted in cubicles together with auxiliary apparatus and wiring to form a factory assembled and tested system. The standard PQFM is offered in IP21 execution and plate execution (IP). The dimensions of a single PQFM unit are 6 x 6 x 215 mm (W x D x H). Large systems consisting of several PQFM units (master + slaves) can be mounted on a base frame for a total height of 225 mm. The dimensions of the IP execution are 498 x 4 x 1696 mm (W x D x H). The PQFM filter is modular in design. On-site extensions are easily made by adding slave units (maximum seven) in parallel to the master unit. The PQFM is suitable for direct connection up to 69V and is offered in two voltage groups (from 28V to 48V and 48V to 69V). The 28V to 48V group includes units of different ratings. Intermixing of units of both equal and unequal rating is allowed in this voltage group. Typical applications Water industry Steel industry Oil and gas industry Cement industry Automotive industry Process plants Pulp and paper 6

Typical result of PQFM application (UPS on a three phase network) 1 Harmonic without PQF 1 Harmonic with PQF 8 8 % FUND 6 4 % FUND 6 4 2 2 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 HARMONIC ORDER 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 HARMONIC ORDER PQFM Technical specification Active filter for three-phase network with or without neutral for filtering of non zero-sequence harmonics and reactive power compensation including load balancing. RMS per unit (5 or 6 Hz) CT requirement Modularity Physical mounting Tolerance Harmonics to filter Degree of filtering Harmonic Attenuation Factor (I H (source)/i H (Load) Reactive Power Communication Programming Response time Load balancing 28V U 48V 48V<U 69V 7 A 1 A* 1 A 13 A 3 CTs required (class 1. or better), 15 VA, 5 Amps secondary rating. Up to 8 units. (intermixing of units of both equal and unequal rating is allowed in the same voltage group). One unit per panel. +/- 1% in voltage. +/- 5% in frequency. 2 individual harmonics selectable from 2 nd to 5 th order. Individually programmable per harmonic in absolute terms. Better than 97%. PF programmable from.6 (inductive) to.6 (capacitive). Using Modbus RTU. Through RS-232 Port with dedicated software (PQF-Link). Using PQF-Manager. Using optional PQF-Link Software and PC (not provided). 4 ms (1-9% filtering). Programmable load balancing. Active Power Protection degree Cubicle dimension Weight (unpacked) Color Installation Environment Ambient temperature Humidity Main options Losses less than 5% of the rated power per unit. IP21 (IP2 open door). IP plate execution. For higher protection degree, please consult us. 6 x 6 x 215 mm (W x D x H). IP21: appr. 255 kg. IP: appr. 125 kg. RAL 732 (beige). Other colors on request. Floor fixation, lifting lugs provided, cable entry from top or bottom. Indoor installation in clean environment up to 1 m altitude. For higher altitudes, please consult us for suitable derating. -5 C to +4 C. For higher ambient temperature, please consult us for suitable derating. Maximum 95% RH; non-condensing. Base frame (1 mm). PQF-Link software. RS-232 - RS-485 converter. Modem connection. Printer (RS-232 based). Main contactor position status lamps. Space heaters. IP41 protection degree. Surge arresters. Temperature probes. * If the nominal system voltage is higher than 6V (U>6V) the rating of PQFM units in this voltage range may be derated automatically depending on the operating temperature. Connection diagram L3 L2 L1 x/5a x/5a x/5a SUPPLY LOAD(S) CT1 CT2 CT3 L1 L2 L3 PQFM P.E. Modbus communication Electrical digital I/O interface 7

PQFK: the ABB solution for active filtering of harmonics for commercial loads including zero-sequence harmonics in the neutral Contactor and fuses PQF-Manager Versatile user interface Digital Control (DSP) Programmable filtering characteristics Perfect multi-tuning to selected harmonics (including zero-sequence) Not overloadable Programmable power factor correction Load balancing feature Zero-Q filtering capability Programmable task priorities Power electronics PWM converter with DC capacitors IGBT technology Forced air cooling Top or bottom cable entry Description W D H PQFK The PQFK can consist of one master and up to three slave units mounted in cubicles together with auxiliary apparatus and wiring to form a factory assembled and tested system. The standard PQFK is offered in IP21 execution and plate execution (IP). The dimensions of a single PQFK unit are 6 x 6 x 215 mm (W x D x H). Large systems consisting of several PQFK units (master + slaves) can be mounted on a base frame for a total height of 225 mm. The dimensions of the IP execution are 498 x 4 x 1696 mm (W x D x H). The PQFK filter is modular in design. On-site extensions are easily made by adding slave units (maximum three) in parallel to the master unit. The PQFK is suitable for direct connection up to 415 V. The PQFK is offered in units of different ratings. Intermixing of units of unequal rating is not allowed. Typical applications Offices and buildings, UPS sytems, HVAC, Computer centers, Lifts,... 8

Typical result of PQFK application (commercial building) Neutral harmonic without PQF Neutral harmonic with PQF 1 1 8 8 % FUND 6 4 % FUND 6 4 2 2 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 HARMONIC ORDER Note: the PQFK filters also harmonics between lines apart from the neutral conductor. 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 HARMONIC ORDER PQFK Technical specification Active filter for three-phase four-wire systems for filtering of harmonics, including zero-sequence in the neutral, reactive power compensation and load balancing. RMS per unit (5 or 6 Hz) Neutral Current CT requirement Modularity Physical mounting Tolerance Harmonics to filter Degree of filtering Harmonic Attenuation Factor (I H (source)/i H (Load) Reactive Power Communication Programming Response time Load balancing 28V U 415V 4 A 7 A 1 A 3 times the line RMS mentioned above. 3 CTs required (class 1. or better), 15 VA, 5 Amps secondary rating. Up to 4 units. One unit per panel. +/- 1% in voltage. +/- 5% in frequency. 15 individual harmonics selectable from 2 nd to 5 th order. Individually programmable per harmonic in absolute terms. Better than 97%. PF programmable from.6 (inductive) to.6 (capacitive). Using Modbus RTU. Through RS-232 Port with dedicated software (PQF-Link). Using PQF-Manager. Using optional PQF-Link Software and PC (not provided). 4 ms (1-9% filtering). Programmable load balancing between phases. Active Power Protection degree Cubicle dimension Weight (unpacked) Color Installation Environment Ambient temperature Humidity Main options Losses less than 5% of the rated power per unit. IP21 (IP2 open door). IP plate execution. For higher protection degree, please consult us. 6 x 6 x 215 mm (W x D x H). IP21: appr. 25 kg. IP: appr. 175 kg. RAL 732 (beige). Other colors on request. Floor fixation, lifting lugs provided, cable entry from top or bottom. Indoor installation in clean environment up to 1 m altitude. For higher altitudes, please consult us for suitable derating. -5 C to + 4 C. For higher ambient temperature, please consult us for suitable derating. Maximum 95% RH; non-condensing. Base frame (1 mm). PQF-Link software. RS-232 - RS-485 converter. Modem connection. Printer (RS-232 based). Main contactor position status lamps. Space heaters. IP41 protection degree. Surge arresters. Temperature probes. Connection diagram SUPPLY N LOAD(S) PQFK Modbus communication Electrical digital I/O interface 9

The PQF-Manager The PQF-Manager is the Graphical User Interface provided in all the PQF types as a standard accessory. It offers direct control, programming, monitoring capabilities without a PC, communication facilities and detailed fault and event logging with real time stamp. The PQF-Manager (144 x 144 mm), fitted in the front panel of the PQF with its large LCD screen display (64 x 132 pixel) makes operating the filter very convenient. The PQF-Manager provides the following main functions : Starting, stopping and resetting the filter Measurement, analysis, logging and printing of characteristic parameters Setting up the filter Monitoring the filter load and fault logging Providing filter identification information KEYPAD There are 5 keys which include Up, Down, OK, Escape and Help functions. Using these keys the user easily navigates through the various menus and controls the PQF. MENUS Four main menus exist: Measurements Settings PQF monitoring About PQF Measurements The PQF-Manager measures all parameters like Line voltages* (RMS and fundamental) Line s* (RMS and fundamental) Filter s* (RMS) Frequency Voltage distortion Current distortion Line imbalance Active power (kw) Reactive power (kvar) Apparent Power (kva) Displacement PF PF DC voltage indication Max. IGBT temperature As the PQF-Manager allows monitoring of temperatures using two temperature probes (optional), these two temperatures too are displayed. The PQF-Manager offers an excellent min/max logging function which can display the threshold value, the maximum value and its duration for almost all network parameters listed above and the two temperatures measured by the external temperature probes. It also displays the threshold value for network frequency (both maximum and minimum possible values). * Harmonic charts, harmonic tables and waveforms can be displayed. 1

Settings The Settings menu has various sub menus allowing a wide range of possibilities for the user to set up the PQF parameters, target values, task priorities and installation settings like CT ratio, derating factor, unit rating, network parameters like voltage and frequency, The commissioning settings are used to set the basic parameters which include the network characteristics, unit rating, derating, real time clock settings, print and communication settings. There is also an automatic CT detection program which finds wrong CT connections and proposes CT ratio. PQF Monitoring This menu allows an overview of the PQF operation including the fault and event log. The PQF loading indicates the percentage of filter capacity used. The faults and events logged have a real time stamp. About PQF This menu shows the serial number and software version of the PQF. The settings may be protected by a password. A hardware lock is also available on the rear side of the PQF-Manager to avoid any unauthorized or accidental change of PQF-Manager settings. Powerful features Full graphics display With its large dimensions and the clear positioning of information, prompts and icons, the PQF-Manager offers a high level of readability and an unprecedented level of viewing comfort. Menu navigation A simple and user friendly organization of menus and items makes the navigation easy and intuitive. Easy commissioning With automatic detection and correction of CT reversal commissioning is made easy. Main /auxiliary parameters The PQF-Manager allows two sets of parameters for harmonic filtering and reactive power compensation. Programmable electrical digital I/O The PQF-Manager has two opto-isolated digital inputs, six programmable digital outputs and two potential free alarm contacts. Min/Max logging The PQF-Manager can record the total duration any specific network parameter has exceeded the set value as well as record the extreme values measured. Communication The PQF-Manager is provided with Modbus RTU communication features. Through a Modbus RS-485 converter (optional), the PQF can be linked to a supervision system of the customer. All parameters, settings and measurements are accessible remotely. Help button The Help button gives an instant access to a comprehensive description of most of the features and functionality of the PQF. threshold % t 1 t 2 maximum recorded t 3 time total duration = t 1 + t 2 + t 3 11

The PQF-Link software (optional) The PQF-Link software offers direct control, programming and monitoring capability from a PC through the RS-232 serial port. All the features of the PQF-Link are directly accessible by clicking on the icons of the shortcut menu. According to the login level of the user, different icons are displayed. Line spectrum and waveform (3 phases) displayed simultaneously Three different access levels are defined in the login procedure. Particular features include: Detailed information on PQF status: % of filter capacity used Fault history Advanced spectrum display - bar graph and table of values in the same window: Line voltages Line s Filter s Display of the PQF and network waveforms with a variable time base: Line voltages Line s Filter s Network information (RMS, THD, ) Simultaneous waveform display for the 3 phases Continuous updating of displayed information or snapshot display Remote control and programming of the PQF On/off Mode selection Reactive power control and load balancing Harmonic requirements set up Remote installation set-up Network characteristics Filter sensors Filter hardware Display of several windows simultaneously Add/remove users and define their access level The PQF-Link works under Windows NT 4 (Service Pack 3 minimum), or Windows 2. A cable for PC connection is supplied with the PQF-Link. Simultaneous display of several windows 12

Examples of units combinations PQFI From 28V to 48V (voltage group V1) PQFM Filter Units combinations for PQFI 25 A PQFI V1 M25 45 A PQFI V1 M45 7 A PQFI V1 M45 + S25 9 A PQFI V1 M45 + S45 115 A PQFI V1 M45 + S45 + S25 135 A PQFI V1 M45 + S45 + S45 16 A PQFI V1 M45 + S45 + S45 + S25 18 A PQFI V1 M45 + S45 + S45 + S45 25 A PQFI V1 M45 + S45 + S45 + S45 + S25 225 A PQFI V1 M45 + S45 + S45 + S45 + S45 25 A PQFI V1 M45 + S45 + S45 + S45 + S45 + S25 295 A PQFI V1 M45 + S45 + S45 + S45 + S45 + S45 + S25 36 A PQFI V1 M45 + S45 + S45 + S45 + S45 + S45 + S45 + S45 M25: Master 25 A S25: Slave 25 A M45: Master 45 A S45: Slave 45 A Filter Units combinations for PQFM 7 A PQFM V1 M7 1 A PQFM V1 M1 13 A PQFM V1 M13 17 A PQFM V1 M1 + S7 2 A PQFM V1 M1 + S1 26 A PQFM V1 M13 + S13 3 A PQFM V1 M1 + S1 + S1 36 A PQFM V1 M13 + S13 + S1 4 A PQFM V1 M1 + S1 + S1 + S1 49 A PQFM V1 M13 + S13 + S1 + S1 52 A PQFM V1 M13 + S13 + S13 + S13 M7: Master 7 A S7: Slave 7 A M1: Master 1 A S1: Slave 1 A M13: Master 13 A S13: Slave 13 A PQFI From 48V to 69V (voltage group V2) PQFM Filter Units combinations for PQFI 18 A PQFI V2 M18 32 A PQFI V2 M32 5 A PQFI V2 M32 + S18 64 A PQFI V2 M32 + S32 82 A PQFI V2 M32 + S32 + S18 96 A PQFI V2 M32 + S32 + S32 114 A PQFI V2 M32 + S32 + S32 + S18 146 A PQFI V2 M32 + S32 + S32 + S32 + S18 178 A PQFI V2 M32 + S32 + S32 + S32 + S32 + S18 192 A PQFI V2 M32 + S32 + S32 + S32 + S32 + S32 21 A PQFI V2 M32 + S32 + S32 + S32 + S32 + S32 + S18 256 A PQFI V2 M32 + S32 + S32 + S32 + S32 + S32 + S32 + S32 Filter Units combinations for PQFM 1 A PQFM V2 M1 2 A PQFM V2 M1 + S1 3 A PQFM V2 M1 + S1 + S1 4 A PQFM V2 M1 + S1 + S1 +S1 5 A PQFM V2 M1 + S1 + S1 +S1 + S1 6 A PQFM V2 M1 + S1 + S1 +S1 + S1 +S1 7 A PQFM V2 M1 + S1 + S1 +S1 + S1 +S1 +S1 8 A PQFM V2 M1 + S1 + S1 +S1 + S1 +S1 +S1+S1 M1: Master 1 A* S1: Slave 1 A* M18: Master 18 A* S18: Slave 18 A* M32: Master 32 A* S32: Slave 32 A* * If the nominal system voltage is higher than 6V (U>6V) the rating of PQFI and PQFM units in this voltage range may be derated automatically depending on the operating temperature. PQFK From 28V to 415V PQFK Filter Units combinations for PQFK Filter Units combinations for PQFK 4 A PQFK M4 3 A PQFK M1 + S1+ S1 7 A PQFK M7 4 A PQFK M1 + S1+ S1 + S1 1 A PQFK M1 14 A PQFK M7 + S7 M1: Master 4 A S1: Slave 4 A 2 A PQFK M1 + S1 M2: Master 7 A S2: Slave 7 A 21 A PQFK M7 + S7+ S7 M3: Master 1 A S3: Slave 1 A Intermixing of units of unequal rating is not allowed for PQFK filters. Note: all ratings are for a max. ambient temperature of 4 C. Other ratings can be obtained by other combinations. Please consult us for best possible combinations. The PQFI range of filters will be available soon.

ABB Inc. 126 Hatton Road Wichita Falls, TX 7632 Telephone 888-385-1221; 94-397-7 Fax 94-397-785 http://www.abb-control.com Publication LV 13 No. 1SXU 982 13 C21 Printed in USA, December, 24