Active Harmonic Filter

Similar documents
APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Design Specifications Low Voltage Active Harmonic Filter

AccuSine PCS Active Harmonic Filter. Cruise through rough waves in your electrical network

AccuSine PCS Active Harmonic Filter. Cruising through rough waves in your electrical network

Liebert AF2 Next Generation Active Harmonic Filter. Power Protection for Business-Critical Continuity TM

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

Low Pass Harmonic Filters

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

Active Harmonic Filters IPC150 AHF Series

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner

TOSHIBA International Corp

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Power IT LV Active Filters PQFA - PQFL - PQFT

Active Harmonic Filter (AHF)

Type AHF Active Harmonic Filter

Phoenix DX Clean Power (18 Pulse) AC Drive

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

Power Processor - Series 700F 10KVA to 150KVA

Guide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

APPLICATIONS. AFQ Active Multi-Function Filter. AFQ solves thousands of problems in countless types of installations, in particular the following:

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

High Frequency Sinewave Guardian TM Filter

Reliable power onboard and offshore

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

LV Compensation & Filtering Products

Active Harmonic Filter (AF3)

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

Presents. Harmonics Years

Introduction: TAS PowerTek Ltd. MAVROS

PowerGard Series C 18-Pulse Enclosed Drive Controllers

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM

High Frequency SineWave Guardian TM Filter

StacoDVR-4 Digital Voltage Regulator Electromechanical three-phase kVA

ULTRA-K Series 600K - he

AF91 Adjustable Frequency Drives Series B

Power-Sure 700. Technical Data TD158001EN. Contents

P2 Power Solutions Pvt. Ltd.

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

ADJUSTABLE SPEED DRIVES FS1

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

Fluke Clamp Meters Solutions for every need

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

Distribution/Substation Transformer

LINEATOR. Advanced Universal Harmonic Filter

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

Power Quality Solutions

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

PRODUCT FEATURES TYPICAL APPLICATIONS

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

Thyristorised Automatic Power Factor

S11 Adjustable Speed Drive Engineering Specification

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

SECTION AUTOMATIC TRANSFER SWITCH

CASE STUDY. Implementation of Active Harmonic Filters at Ford Motor Company SA Silverton Plant

Power Quality Monitoring and Power Metering Tutorial

PFCC-1000 series. Powerful Flexibility Durability - Quality. Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

B9000 FXS kVA B9600 FXS kVA

Dranetz-BMI : the award-winning hand-held 3-phase power analyzer

Generator Advanced Concepts

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

Power Quality Analysers

Harmonics I Harmonics White Paper. Power Protection Products, Inc. by Dan Maxcy l 2018 Update

Harmonic mitigating transformers. Energy savings through harmonic mitigation

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

Power Conditioners product guide

Data Sheet. RISH Master Record %THD

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

LAUREL ELECTRONICS, INC.

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

Reduce harmonics in HVAC&R inverters through C-Less technology

Harmonics, its Mitigation & Result of Case study of Spinning Mill

Est Static Frequency Converter. SFX 10kVA - 10MVA

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

Harmonic mitigating transformers. Energy savings through harmonic mitigation

Harmonic Power. A VFDs.com Whitepaper Written by Ernesto Jimenez

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

60K(i) - 260K(i) THREE PHASE. SureImage IMAGING & TREATMENT SERIES

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

StacoDVR-5 60kVA to 6000kVA

Power factor correction and harmonic filtering. Harmonic filters and EMI

THE COMPREHENSIVE APPROACH TO FACILITY POWER QUALITY

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

Transcription:

Reactive Power and Harmonic Compensation Active Harmonic Filter The new StacoSine Plus active harmonic filter is available in 100, 150, 200 and 300 amp assemblies. Modules can be paralleled for a maximum capacity of 1200 amps of harmonic mitigation. When multiple units are paralleled only one controller in one of the modules is needed to assure proper harmonic mitigation. This controller has a touch screen that allows for easy onsite programming. Besides correcting up to the 51st harmonic, the unit can compensate for both lagging and leading reactive power, and can be programmed from 0.7 lagging to 0.7 leading power factor. Highlights Reduces operation and maintenance costs Variable power factor and harmonic current control gives the user more flexibility to control his power system by allowing power factor improvement without adding a capacitor bank Filters up to the 51 st harmonic so all unwanted harmonic levels are reduced to allow for compliance with the IEEE 519 Standard No need for complex site analysis means simpler application and installation assuring virtually no downtime 480 volt, 100 to 300 amp assemblies are available with paralleling capability up to 1200 amps to correct at larger facilities 7 LCD touch screen allows for easier operator interface One touch screen can control up to 8 modules (up to 1200 amps) in parallel allowing for more precise and predictable harmonic mitigation Units are UL and cul Listed Roll back feature assures that the unit will continue to operate and not overheat in a high ambient temperature environment CTs can be installed on either the source or load side of the active harmonic filter allowing for a more flexible installation www.stacoenergy.com Your Tailored Power Solutions Provider TM

Harmonic Problems With the increased presence of electronics on power distribution systems, disruptive anomalies are created and harmonics can become a problem. These problems are usually manifested as transformer overheating, motor and generator burnout, neutral heating, electronic control malfunctioning, breaker tripping and capacitor failures. Major contributors to Harmonics Fluorescent Lamps Computers and Peripherals Welding Machines Uninterruptible Power Supplies (UPS) AC/DC Variable Speed Drives Frequency Converters DC Power Systems/Chargers The StacoSine Plus Active Harmonic Filter Active harmonic filters use a DSP control system to monitor the nonlinear load and dynamically correct every harmonic order from the 2nd to the 51st. By injecting a compensating current into the load, the sine wave is restored, attenuating harmonic levels at the point of installation. StacoSine Plus meets or exceeds Total Demand Distortion (TDD) limits specified in table 10.3 of the IEEE 519 Standards. The filter can accept a signal from a CT secondary of 1 amp (standard) or 5 amps with the optional kit that will convert the signal from 5 amps to 1 amp. The StacoSine Plus high speed processor cancels high frequency output current, while it ultimately determines the precise value of injected load current. StacoSine Plus IGBT based platform has been designed to operate at levels that continuously adapt to rapid load fluctuations. With its efficient operation and small physical size, it is ideal for a wide variety of industrial and commercial environments. Typical Applications for Active Harmonic Filters Water and waste water treatment facilities Textile and paper mills Steel mills and facilities with induction furnaces Pharmaceutical facilities Petrochemical plants Data Centers, servers, printers, and other IT equipment Hospitals and medical facilities Solar and wind farms Material handling facilities A Real Solution The StacoSine Plus behaves like a harmonics current generator. It measures the harmonics generated from a nonlinear load and cancels the harmonics with a newly generated, opposite phase shifted harmonic current of the same amplitude (AC/DC/AC). This allows it to: Eliminate all harmonic currents from nonlinear loads Compensate reactive power factor of lagging or leading loads Act as a damping resistor to prevent harmonic resonance Staco Energy Products Co.

Why StacoSine Plus is A Better Choice With other harmonic mitigation solutions, expensive and time-consuming site data collection, power quality surveys and computer generated studies are usually needed. Most harmonic filters are designed to accommodate just one or a few harmonic orders. The StacoSine Plus corrects a full range of harmonic orders, and will not create a resonance condition with other existing equipment, so only minimal up-front analysis is required. The StacoSine Plus can be easily and conveniently added in parallel with other active filters, to accommodate future facility expansions or equipment additions. Virtually no time is lost for installation, supporting the important uptime operation of your facility. The rating (size) of the StacoSine Plus is based on nonlinear load requirements (corrective current), not both linear and nonlinear current like traditional filter equipment. That means that you can install a StacoSine Plus system at a reduced ampere rating, which will lower initial capital costs. While injecting current into the system to mitigate harmonics, the Staco Sine Plus also has the capability to compensate for both leading and lagging power factor. The power factor correction can be programmed to correct from 0.7 lagging to 0.7 leading. It can also be programmed for a fixed amount of kvar. The user friendly 7 color touch screen display allows for easy operation and maintenance programming of the active filter. This display can control and show the status of the main active filter and up to seven additional active filters connected in parallel with it. This allows for up to 1200 amps of harmonic current to be injected into the power system to mitigate harmonics. Each filter can be controlled from just one location saving valuable maintenance time. Up to 300 events are recorded and logged for each connected filter. To help save energy, the StacoSine Plus can be programmed to shut down when a certain minimum load current is reached and to be energized when that level is exceeded. Optional monitoring software is available to allow the StacoSine Plus to communicate remotely using USB, RS-485 or Ethernet (TCP/IP) interface. The StacoSine Plus can be set to accept either load side or source side CT signals. This is particularly useful in very tight installations or if the source side connection is at the transformer. www.stacoenergy.com

Dimensions GENERAL CHARACTERISTICS: STORAGE TEMPERATURE -20ºC ~ 70ºC OPERATING TEMPERATURE 0ºC ~ 40ºC WITHOUT DERATING #1 RELATIVE HUMIDITY < 95% OPERATING ALTITUDE <3281 FT [1000 M] WITHOUT DERATING #2 REFERENCE HARMONIC EN 61000-3-4, IEEE 519-1992 STANDARD REFERENCE DESIGN STANDARD EN60146 UL 508 SAFETY STANDARD #1 ABOVE 40 C (104 F), THE MAXIMUM OUTPUT CURRENT MUST BE DERATED BY 3.5% FOR EACH ADDITIONAL 1.8 F (1 C) UP TO 122 F (50 C) MAXIMUM LIMIT #2 OVER 3300 FT [1000M]) ABOVE SEA LEVEL, THE MAXIMUM OUTPUT CURRENT MUST BE DERATED BY 1% FOR EACH ADDITIONAL 330 FT [100M]. ELECTRICAL SPECIFICATION: INPUT VOLTAGE 480V +10%,-20% PHASE/WIRES 3 PHASE 3WIRES FREQUENCY 50/60±3 HZ MAXIMUM COMPENSATION 200 ARMS CURRENT/PHASE COMPENSATED HARMONIC ORDERS FROM 2ND TO 51 ST ORDER AND CAN BE SELECTIVE. POWER FACTOR CORRECTION COMPENSATES BOTH LAGGING AND LEADING REACTIVE POWER. POWER FACTOR CAN BE CONFIGURED FROM 0.7 LAGGING TO 0.7 LEADING. CT RATIO CAN BE SET. PRIMARY CURRENT: 100-10,000 A SECONDARY CURRENT: 1 A (STANDARD)/5 A (OPTIONAL) #1 SOURCE SIDE: CLOSED LOOP CT LOCATION CONTROL; LOAD SIDE: OPEN LOOP CONTROL RESPONSE TIME < 20 MS INRUSH CURRENT LESS THAN RATED CURRENT CURRENT LIMITATION YES, AT FULL CORRECTION MAXIMUM HEAT LOSS 5000 WATTS AIRFLOW REQUIREMENTS > 324 CFM [550 M³/H] PER ENCLOSURE NOISE LEVEL <65 DB FROM 3.28 FT [1 METER] MECHANICAL SPECIFICATION: COLOR TOTAL DIMENSIONS (W*D*H) #3 TOTAL WEIGHT RAL9011(PANTONE PROCESS BLACK C) 47.2 X 23.6 X 74.8 INCH [1200 X 600 X 1900 MM] 850 LB [386 KGS] #3 UNIT SHIPPED AS (2) SEPARATE ENCLOSURES TO BE INSTALLED AT SITE WITH (2) SEPERATE POWER DISCONNECTS (CUSTOMER SUPPLED), (3) EXTERNAL CT, (3) PARALLEL CTS, AND A (2) CONDUCTOR COMMUNICATION CABLE LOOP. HMI & COMMUNICATION INTERFACE SPECIFICATION: 7 LCD TOUCH SCREEN CONTROL LCD CONTROL PANEL OFFERS THE PANEL FOLLOWING FUNCTIONS: METER: PARAMETER, WAVEFORM, AND SPECTRUM EVENT LOG: UP TO 300 RECORDS (FIFO) CONFIGURATION: COMPENSATION SETTING, COMPENSATION LOGIC CONTROL, AND SYSTEM SETTING. MULTI-LANGUAGE DRY CONTACTS 3 OUTPUT DRY CONTACTS 1 INPUT DRY CONTACT COMMUNICATION INTERFACE USB, RS-485, ETHERNET CONFIGURATION CONFIGURABLE BY USING OUR COMPUTER SERVICE SOFTWARE OR BY USING THE LCD CONTROL PANEL MONITORING SOFTWARE STACOSINE-LINK34 (OPTIONAL) COMMUNICATION PROTOCOL J-BUS/MOD BUS PROTOCOL 200 and 300 amp 100 and 150 amp StacoSine Plus Ratings and Dimensions Part # Amps Dimensions (H"xW"xD") Weight (lbs.) AF-0100-34E-3486F1 100 74.8x23.6x23.6 425 AF-0150-34E-3486F1 150 74.8x23.6x23.6 452 AF-0200-34E-3486F1 200 74.8x47.2x23.6 850 AF-0300-34E-3486F1 300 74.8x47.2x23.6 904 StacoSine Plus 200 and 300 amp assemblies consist of two modules with one control and display. These are shipped as two assemblies which must be interconnected together in the fiel. Interconnecting control cables are included.

Specifi ations Part # AF-0100-34E-3486F1 AF-0150-34E-3486F1 AF-0200-34E-3486F1 AF-0300-34E-3486F1 Input Voltage 480V +10%,-20% Phase/Wires Frequency 3 phase, 3 wire 50/60±3 Hz (Auto Sensing) Compensating Current/Phase 100 Arms 150 Arms 200 Arms 300 Arms Compensated Harmonic Orders Power Factor Correction From 2 nd to 51 st order. Up to 12 orders active simultaneously (2 nd - 31 st ). Higher Order Compensation (32 nd - 51 st ) Disable/Enable operation. Compensates both lagging and leading reactive power. Power factor can be programmed from 0.7 lagging to 0.7 leading CT Ratio Primary Current: 100A-10000A Secondary Current: 1A(Standard)/5A (Optional) CT Location Source Side: Close Loop Control Load Side: Open Loop Control Response Time Inrush Current Current Limitation Parallel < 20 ms Less than rated current Yes, at full correcting Up to 1200 amps, 8 Units maximum Maximum Heat losses 2500 Watts 3200 Watts 5000 Watts 6400 Watts Dimensions (H"xW"xD") 74.8x23.6x23.6 74.8x47.2x23.6 Weight (lbs.) 425 452 850 904 Enclosure NEMA 1 Black Equipment Storage Temperature -20 C to + 70 C Operating Temperature +0 C to +40 C Relative Humidity <95% Operating Altitude <1000 m Reference Harmonic Standard EN61000-3-4, IEEE 519-1992 Reference Design Standard EN60146 Safety Standard UL 508 Staco Energy Products Co.

StacoSine Plus Active Harmonic Filter Open Frame Chassis Design For switchgear and motor control center manufacturers, the StacoSine Plus is available in an open frame chassis design for mounting in a cubicle. Designed and built to the same standards as the enclosed model, this unit allows a manufacturer to include active harmonic filtering inside his equipment for more precise filtering with an integrated look. This reduces the user s installation time and cost, and uses the least amount of floor space. The StacoSine Plus Open Frame design has the same characteristics and advantages as the enclosed version so you don t have to compromise on harmonic mitigation. Highlights Integration into the switchgear cabinets reduces installation and maintenance costs while saving on floor space Variable power factor and harmonic current control gives the user more flexibility to control his power system by allowing power factor improvement without adding a capacitor bank Filters up to the 51st harmonic so all unwanted harmonic levels are reduced to allow for compliance with the IEEE 519 Standard No need for complex site analysis means simpler application and installation assuring virtually no downtime 480 volt, 100 to 300 amp assemblies are available with paralleling capability up to 1200 amps to correct at larger facilities 7 LCD touch screen allows for easier operator interface One touch screen can control up to 8 modules (up to 1200 amps) in parallel allowing for more precise and predictable harmonic mitigation Units are UL and cul Listed Roll back feature assures that the unit will continue to operate and not overheat in a high ambient temperature environment StacoSine Plus Ratings and Dimensions Part # Amps Dimensions (H"x- W"xD") Weight (lbs.) AF-0100-34E-3486C1 100 59.1x17.3x17.4 242 AF-0150-34E-3486C1 150 59.1x17.3x17.4 264 Specifi ations The specifications listed above for the enclosed unit apply to the open frame unit. www.stacoenergy.com

Wall mount 25 and 50 amp StacoSine Active Harmonic Filter When only a small amount of compensating harmonic current is needed the original wall mount StacoSine 25 and 50 amp units are available. These units correct the same harmonic spectrum while offering a fixed amount of kvar for power factor correction. A door mounted LCD graphic multifunctional display/analyzer with 8 function keypad means easy operation and maintenance programming. While correcting up to the 51st harmonic, the display shows the data up to the 31st order. The StacoSine wall mount active harmonic filter is an excellent solution for one or a few variable frequency drives or for a smaller facility. Specifi ations Part # AF-0025-00E-3486W1 AF-0050-00E-3486W1 Input Voltage 208-480V +/-15% Phase/Wires 3 phase, 3 wire Frequency 50/60±3 Hz (Auto Sensing) Compensating Current/Phase 25 Arms 50 Arms From 3rd to 51st order. Up to 12 orders active simultaneously (3rd-31st). Compensated Harmonic Orders Higher Order Compensation (32nd-51st) Disable/Enable operation. Power Factor Correction 15.6 kvar at 480 volts 31.3 kvar at 480 volts CT Ratio 2000:1 CT Location Source Side: Close Loop Control Load Side: Open Loop Control Response Time < 40 ms Inrush Current Less than rated current Current Limitation Yes, at full correcting Maximum Heat losses 550 Watts 950 Watts Dimensions (H xw"xd") 34.65x16.14x15.35 Weight (lbs.) 121 154 Enclosure NEMA 1 gray Equipment Storage Temperature -20 C to + 70 C Operating Temperature +0 C to +40 C Relative Humidity <95% Operating Altitude <1000 m Reference Harmonic Standard EN61000-3-4, IEEE 519-1992 Reference Design Standard EN60146 Safety Standard UL 508 Audible Noise from 1 meter 60 db from 1 meter (3.28 ft) StacoSine Plus Ratings and Dimensions Part # Amps Dimensions (H"xW"xD") Weight (lbs.) AF-0025-00E-3486W1 25 34.65x16.14x15.35 121 AF-0050-00E-3486W1 50 34.65x16.14x15.35 154 Staco Energy Products Co.

Service Options Staco specializes in providing choice and flexibility by developing tailored solutions for preventive and remedial maintenance services, as well as emergency repairs for all of our products. Staco Service is built upon a nationwide network of highly trained and motivated customer support engineers and technicians who can provide professional services and care throughout the life of your equipment. Start-Ups Preventive Maintenance Spare Parts Battery Analysis/Refresh/Replacement On-Site Training Time & Material Services About Staco Energy Products Since 1937, customers worldwide have been relying on Staco Energy Products Company to deliver voltage control and power quality solutions tailored to their needs. As a leading power quality resource, we offer our cus omers world-class support; from our thorough applications assessment, to our ability to design and deliver a solution that is tailored to the specific needs of our cus omers; through delivery and commissioning. Our professional, factory trained service team is in place to ensure that our customers revenues are protected, and their investment provides them with many years of trouble free operation. Staco develops total power solutions for OEM and end user applications. In addition to the StacoSine products we offer a wide rray of power quality products, including: Uninterruptible Power Supplies Power Conditioners Voltage Regulators Power Factor Correction and Harmonic Mitigation Active Harmonic Filters Variable Transformers Custom Engineered Test Sets Represented locally by: Contact Us: US Toll Free: 866-261-1191 Phone: 937-253-1191 E-mail: sales@stacoenergy.com ISO 9001 : 2008 CERTIFIED Your Tailored Power Solutions Provider TM 2014, Staco Energy Products Co. Staco-Sine-Plus_bro-042514 For more information about StacoSine AHF www.stacoenergy.com