Remote Sensing Calibration Solutions

Similar documents
Full Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions

Solid State Luminance Standards

ENMAP RADIOMETRIC INFLIGHT CALIBRATION, POST-LAUNCH PRODUCT VALIDATION, AND INSTRUMENT CHARACTERIZATION ACTIVITIES

White Paper on SWIR Camera Test The New Swux Unit Austin Richards, FLIR Chris Durell, Joe Jablonski, Labsphere Martin Hübner, Hensoldt.

Comprehensive Vicarious Calibration and Characterization of a Small Satellite Constellation Using the Specular Array Calibration (SPARC) Method

DEFENSE APPLICATIONS IN HYPERSPECTRAL REMOTE SENSING

The Hyperspectral UAV (HyUAV) a novel UAV-based spectroscopy tool for environmental monitoring

Compact High Resolution Imaging Spectrometer (CHRIS) siraelectro-optics

Ground Truth for Calibrating Optical Imagery to Reflectance

Company synopsis. MSU series

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

BASLER A601f / A602f

Signal-to-Noise Ratio (SNR) discussion

MR-i. Hyperspectral Imaging FT-Spectroradiometers Radiometric Accuracy for Infrared Signature Measurements

Radiometric performance of Second Generation Global Imager (SGLI) using integrating sphere

MR-i. Hyperspectral Imaging FT-Spectroradiometers Radiometric Accuracy for Infrared Signature Measurements

Hyperspectral goes to UAV and thermal

A Kalman-Filtering Approach to High Dynamic Range Imaging for Measurement Applications

Basler. Line Scan Cameras

LED Lighting Flux and Color Measurement System (LFC)

A simulation tool for evaluating digital camera image quality

Improving the Collection Efficiency of Raman Scattering

OPAL Optical Profiling of the Atmospheric Limb

Module 3 Introduction to GIS. Lecture 8 GIS data acquisition

NIST Agency Report May 2012 OUTLINE. The case for traceability NMI capabilities A view to the future the HIP Current/recent NIST activities

PEGASUS : a future tool for providing near real-time high resolution data for disaster management. Lewyckyj Nicolas

EMVA 1288 Data Sheet m0708

INNOVATIVE SPECTRAL IMAGING

PRODUCT OVERVIEW FOR THE. Corona 350 II FLIR SYSTEMS POLYTECH AB

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Wind Imaging Spectrometer and Humidity-sounder (WISH): a Practical NPOESS P3I High-spatial Resolution Sensor

A collection of hyperspectral images for imaging systems research Torbjørn Skauli a,b, Joyce Farrell *a

On the use of water color missions for lakes in 2021

Microscope-Spectrometer

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

LED Tester BTS256-LED

CMOS Star Tracker: Camera Calibration Procedures

Basler aca km. Camera Specification. Measurement protocol using the EMVA Standard 1288 Document Number: BD Version: 03

Hyperspectral Systems: Recent Developments and Low Cost Sensors. 56th Photogrammetric Week in Stuttgart, September 11 to September 15, 2017

RADIOMETRIC CALIBRATION

Basler aca gm. Camera Specification. Measurement protocol using the EMVA Standard 1288 Document Number: BD Version: 01

Basler ral km. Camera Specification. Measurement protocol using the EMVA Standard 1288 Document Number: BD Version: 01

Basler aca640-90gm. Camera Specification. Measurement protocol using the EMVA Standard 1288 Document Number: BD Version: 02

Learning the image processing pipeline

Kazuhiro TANAKA GCOM project team/jaxa April, 2016

A scientific HDR Multi-spectral imaging platform. B. Dupont, Pyxalis, France.

THE HYMAP TM AIRBORNE HYPERSPECTRAL SENSOR: THE SYSTEM, CALIBRATION AND PERFORMANCE

remote sensing? What are the remote sensing principles behind these Definition

Characterization results DR-8k-3.5 digital highspeed linescan sensor. according to. EMVA1288 Standard Revision 2.0

Norsk Elektro Optikk AS (NEO) HySpex Airborne Sensors System Overview

Our Quality Promise WHITE PAPER

Remote Sensing Platforms

Visibility of Uncorrelated Image Noise

Pre-Launch Radiometric Calibration of the S-NPP and JPSS-1 VIIRS Day/Night Bands

We bring quality to light. LumiCam 1300 Imaging Photometer/Colorimeter

Imaging Photometer and Colorimeter

GEO-SolarSIM-D2 and SunTracker-2000/3000

Pulsed Laser Power Measurement Systems

Compact Dual Field-of-View Telescope for Small Satellite Payloads

An Introduction to Remote Sensing & GIS. Introduction

How Farmer Can Utilize Drone Mapping?

The CarbonSat candidate mission - Radiometric and Spectral Performances over Spatially Heterogeneous Scenes

ARMY RDT&E BUDGET ITEM JUSTIFICATION (R-2 Exhibit)

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

Introduction to Remote Sensing

Test Equipment and Method to Characterize a SWIR Digital Imaging System

REVIEW OF ENMAP SCIENTIFIC POTENTIAL AND PREPARATION PHASE

Radiometric Use of WorldView-3 Imagery. Technical Note. 1 WorldView-3 Instrument. 1.1 WorldView-3 Relative Radiance Response

Chapter 5 Nadir looking UV measurement.

Calibration of a Multi-Spectral CubeSat with LandSat Filters

Enhanced LWIR NUC Using an Uncooled Microbolometer Camera

VICARIOUS CALIBRATION SITE SELECTION FOR RAZAKSAT MEDIUM-SIZED APERTURE CAMERA (MAC)

DBSP Observing Manual

Program for UV Intercomparison 2014 in Davos:

ISIS TC Meeting. International Spaceborne Imaging Spectroscopy (ISIS) GRSS Technical Committee Meeting, 16/07/2014, IGARSS 2014

Acquisition and representation of images

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

Challenges in Imaging, Sensors, and Signal Processing

illumia Plus Temperature Controlled Light Measurement Systems

Results of J1 VIIRS testing using NIST s Traveling SIRCUS

OFFensive Swarm-Enabled Tactics (OFFSET)

LWIR NUC Using an Uncooled Microbolometer Camera

Aerial photography and Remote Sensing. Bikini Atoll, 2013 (60 years after nuclear bomb testing)

Calibration considerations for a reduced-timeline optimized approach for VNIR earthorbiting

High Resolution Spectral Video Capture & Computational Photography Xun Cao ( 曹汛 )

Acquisition and representation of images

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

FLEA 3 GigE Vision FLIR IMAGING PERFORMANCE SPECIFICATION. Version 1.1 Revised 1/27/2017

NASTER System Definition Proposal

REPLICATING HUMAN VISION FOR ACCURATE TESTING OF AR/VR DISPLAYS Presented By Eric Eisenberg February 22, 2018

The studies began when the Tiros satellites (1960) provided man s first synoptic view of the Earth s weather systems.

Web of Things for Connected Vehicles. Soumya Kanti Datta Communication Systems Department

Camera Calibration Certificate No: DMC III 27542

Automated Testing of Ultraviolet, Visible, and Infrared Sensors Using Shared Optics

Remote Sensing of the Environment An Earth Resource Perspective John R. Jensen Second Edition

Hyperspectral Sensor

Hyperspectral Image capture and analysis of The Scream (1893)

Int n r t o r d o u d c u ti t on o n to t o Remote Sensing

Remote Sensing Platforms

Transcription:

Remote Sensing Calibration Solutions Cameras, Sensors and Focal Plane Arrays Multispectral and Hyperspectral Imagers Small Satellite Imagers Earth Observation Systems SWIR Band Science and Imaging Reconnaissance and Security Unmanned Aerial Vehicles (UAV) Automotive and Autonomous Vehicles Ground Truth and Vicarious Calibration

HELIOS Uniform Sources for Luminance and Radiance The Remote Sensing industry is technologydriven with rapidly evolving applications. This growing market relies on innovative hardware and software architectures that can work with existing infrastructures, but this is not a one-size-fits-all industry. Customers require scalable solutions that can meet their individual needs and budgets. Scalable, rugged solutions for R&D, production or field applications Unparalleled built-in characterization and performance LabVIEW and many software options with intelligent components for active system configuration Labsphere s HELIOS line of uniform sources for luminance and radiance offers a flexible foundation to meet the challenges for rapidly changing remote sensing needs. The dynamic HELIOS product family combines the best features from Labsphere s 35 years of uniform source product innovation.

D Family Dynamic Range Systems Used in R&D by the satellite community and other applications with the most demanding imaging requirements. Cameras and sensors >16bit, Actual -27bit (167dB) Full day light down to night vision radiances High, medium and low resolution options Remote access and maximum automation Low uncertainty and high precision Tungsten halogen spectrum A Family Air Mass-Albedo-Sunlight Systems Solar spectrums for use in R&D by the satellite, airborne, field imaging and sensing systems. Test as You Fly: Solar Spectrum Cameras and sensors >16bit, Actual -23bit (150dB) Albedo 1 (AM 1) down to night vision light levels UV ranges Resolution and adjustability to meet customer s application and budget High level of absolute characterization

L Family Low Level Systems Specially designed for night vision systems, security cameras, and imagers and sensors with sensitivity. Automated solutions to allow remote use in dark environments Meets MIL Specifications for low level sensing 2856K radiance temperatures and filter options available Accurate, repeatable, high resolution at low light levels Spectralon sphere for best spectral shaping V Family Variable Modular Systems Dynamic manual systems with variable levels based on single lamp and attenuator configurations. Good combination of levels, sizes and range performance for most 12-bit cameras and sensor systems. S Family Static Modular Systems Basic systems with single level or multiple level outputs based on one or multiple lamps. Choose size and light levels to meet your needs and budget. Modular, design driven systems configured for common testing tasks with flexible options to meet your specific needs and budget

Configurable software built on the Integral API foundation with a LabVIEWTM user interface Complete control of all HELIOS modular components State functions that can be set up for system configurations, saved and re-accessed or password protected Scripting functions for simple programs inside and outside HELIOSense GUI TCP enabled scripting and communication functions Hunt & Seek functions using attenuators, detectors and spectrometers Continuous real-time asynchronous data logging with time stamps on all data parameters Infinite Scrolling Display & Data Session Logging Access to control settings and measured parameters SQLite database with export functions Calibration data interface for loading characterization files ser-definable non-linear detector response U tables for external Devices Under Test (DUTs) Standardized tests for your camera or sensor performance with HELIOS Easy to use GUI for the calibrated control of HELIOS systems Automated test and calibration capability for imaging sensors operating in the 0.35 to 2.5 micron region Creation of test configurations and test sequences Creation of test reports Store and apply calibration tables PhotonLAB Standard Test Sets Device Test Type Compliance Linearity & Sensitivity EMVA 1288 (6) Dark Current EMVA 1288 (7) Spatial NU EMVA 1288 (8) 3D Noise NVESD Responsivity Common Practice Spatial NEInp Common Practice Temporal NEInp Common Practice Gain Offset Bad Pixel Common Practice (GOBP) Output Reports/Values Dynamic Range, SNR, Saturation & Other Values Dark Current, Doubling Temperature DSNU, PRNU, NUC or Flat-Fielding 3D Noise Table Responsivity Value NEInp Value Temporal NEInp Value Bad Pixel List

Uniform Sources for Luminance and Radiance RADIANCE SPECTRUM & RADIANCE TEMPERATURE UNCERTAINTY k=2 Find the HELIOS system that best meets your need with solutions based on these critical parameters DYNAMIC RANGE & RESOLUTION FIELD OF VIEW UNIFORMITY & APERTURE SIZE PB-60014-000 Rev.00 sales@labsphere.com www.labsphere.com 2017 Labsphere, Inc. All Rights Reserved