Keysight Technologies M8290A Optical Modulation Analyzer and High-Speed Digitizer Test Solution. Data Sheet

Similar documents
Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies N9310A RF Signal Generator

Keysight N9310A RF Signal Generator

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Keysight Technologies

Keysight Technologies N4985A System Amplifiers

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Keysight Technologies

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Keysight Technologies Migrating Balanced Measurements from the

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight Technologies USB Preamplifiers

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Introduction. Part 1. Introduction...2

Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.

Keysight Technologies Overcoming LTE-A RF Test Challenges. Application Note

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight Technologies N4392A Optical Modulation Analyzer Compact, Portable, Affordable

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

Keysight E5063A ENA Vector Network Analyzer

Keysight M9485A PXIe Multiport Vector Network Analyzer

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300. Application Brief

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

Keysight Technologies 89601B-SSA/89601BN-SSA Spectrum Analysis VSA Software

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies FFT and Pulsed RF Measurements with 3000T X-Series Oscilloscopes. Application Note

Keysight Technologies 8160xx Family of Tunable Laser Sources. Data Sheet

Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note

Keysight Technologies How to Easily Create an Arbitrary Waveform Without Programming. Application Note

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes. Data Sheet

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Keysight Technologies M8196A 92 GSa/s Arbitrary Waveform Generator

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies VSA Software for Simulation Environments BE/89601 BNE

Keysight Technologies 81980A, 81960A, 81940A, 81989A, 81949A, and 81950A Compact Tunable Laser Sources. Data Sheet

Keysight Quickly Generate Power Transients for Testing Automotive Electronics. Application Note

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight N9320B RF Spectrum Analyzer

Keysight Technologies HMMC GHz High-Gain Amplifier

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Keysight Technologies MATLAB Data Analysis Software Packages

Keysight Technologies High Frequency Probing Solutions for Time and Frequency Domain Applications. Application Note

Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight Technologies VOR and ILS Radio Navigation Receiver Test Using Option 302 for Keysight Signal Sources. Application Note

Keysight Technologies Characterizing High-Speed Coherent Optical Transmission Systems

Keysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz. Technical Overview

Keysight Technologies Satellite Signal Monitoring, Reference Solution

Keysight Technologies Isolating Problems and Optimizing Wireless Designs with Digital Demodulation and EVM

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies PXI Programmable Step Attenuator Module

Keysight Technologies PXI Vector Network Analyzer Series. Drive down the size of test

Keysight Technologies Make Better AC RMS Measurements with Your Digital Multimeter. Application Note

Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.

Keysight N8803C CAN, LIN, FlexRay, and CAN-FD Protocol Triggering and Decode Software. Data Sheet

Keysight Technologies Phase Noise X-Series Measurement Application

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight Technologies Wavelength and polarization dependence of 100G-LR4 components. Application Note

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies Power of Impedance Analyzer

Keysight Technologies UXG X-Series Agile Signal Generator, Modified Version N5191A

Keysight Technologies U9400A/C Solid State FET Transfer Switches

Keysight Technologies M8196A 92 GSa/s Arbitrary Waveform Generator

Keysight Technologies A Flexible Testbed to Evaluate Potential Co-Existence Issues Between Radar and Wireless

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight Technologies Achieving Accurate RF and Microwave Power Measurements for Satellite Thermal Vacuum Test. Application Note

Keysight Technologies Enhancing Measurement Performance for the Testing of Wideband MIMO Signals

Keysight U9397A/C FET Solid State Switches (SPDT)

Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview

Keysight Technologies How to Read Your Power Supply s Data Sheet. Application Note

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Keysight Technologies InfiniiScan Event Identification Software

Keysight Technologies Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes.

Keysight Technologies RS-232/UART Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes. Data Sheet

Keysight Technologies

Transcription:

Keysight Technologies M8290A Optical Modulation Analyzer and High-Speed Digitizer Test Solution Data Sheet

02 Keysight M8290A Optical Modulation and High-Speed Digitizer Test Solution - Data Sheet Table of Contents M8290A Modular Coherent Test Solution...03 Turn-key ICR Test Solution...04 Test Solution for Coherent Optical Transmit & Receive Devices...05 M8292A Modular Optical Modulation Analyzer Specifications...06 M8296A Electrical High-Speed Digitizer Specifications...08 General Characteristics...09 Definitions...10 Configure Your M8290A Coherent Test Solution...11

03 Keysight M8290A Optical Modulation and High-Speed Digitizer Test Solution - Data Sheet M8290A Modular Coherent Test Solution Optical coherent transmission technology, initially used in long-haul transmission, is evolving into metro networks and expanding to data center interconnects. Each product generation increases transmission speed by moving to higher symbol rates and higher-order QAM constellations. Today s 100G systems that use quadrature phase shift keying (QPSK) at 32 GBd will evolve to 400G by doubling both the bits per symbol and the symbol rate; i.e., using 16-state quadrature amplitude modulation (16QAM) at 64 GBd. At the same time, the industry s target is to reduce size, cost, and power consumption of the transceiver hardware. Higher complexity transmission schemes, combined with new challenges that result from dense electronic and photonic integration, lead to tighter requirements and lower performance margins for all components as well as the assembled transceivers. Increasing data throughput while reducing size, cost and power consumption requires rigorous testing during development, NPI, and production phases. The M8290A rack-mountable modular coherent test system for the AXIe platform addresses the 400G speed class in a significantly narrower form factor and a more attractive price point than today s oscilloscope-based solutions for this speed class. For coherent transmitter and receiver testing, the M8292A compact optical modulation analyzer and M8296A high-speed digitizer fill the gap between the portable N4392A integrated optical modulation analyzer for 100G and the real-time oscilloscope-based N4391A optical modulation analyzer supporting speed classes of 400G, 600G and 1 Terabit per second. The compact and modular approach makes the M8290A optical modulation analyzer and highspeed digitizer test solution an ideal system for coherent transmitter signal qualification for EVM and related parameters as well as for coherent optical device characterization including assemblies like ICR, PMQ, CDM, IC-TROSA or ACO. The modular concept addresses the needs of development teams, new product introduction groups and production test engineers looking for affordable test equipment for 400G. The M8290A optical modulation analyzer and high-speed digitizer test solution provides a combination of compactness, affordability and performance that cannot be achieved with current oscilloscope-based solutions in this speed class. Figure 1. Configuration with optical and electrical modules (left), and configuration with electrical module only (right).

04 Keysight M8290A Optical Modulation and High-Speed Digitizer Test Solution - Data Sheet In the M8290A system configuration, the M8292A optical modulation analyzer module (a 2-slot AXIe module) and a 4-channel single-slot electrical digitizer module are available, both operating at 92 GSa/s sampling rate. A 5-slot AXIe chassis has room to plug in an additional electrical source module like the M8195A or M8196A arbitrary waveform generator. The modular architecture enables stimulus and analyzer capabilities in one mainframe to form a very compact stimulus-response test solution at an unmatched price/performance level. Turn-key ICR Test Solution Integrated Coherent Receiver (ICR) modules are key components in coherent transmission systems and are more challenging to test than direct-detection receiver optical sub-assemblies (ROSAs), as the ICRs have phase-sensitive signal detection and provide four electrical outputs and two optical inputs. The test instruments used in ROSA S21 testing cannot be used in a similar way for S-parameter testing of ICRs, making S-parameter testing very challenging. To help users set up S-parameter tests for ICRs in significantly less time than developing their own solution, the M8290A provides an optionally-available ICR test software that measures: S21 magnitude responses IQ skew, XY skew IQ angle IQ and XY gain imbalance EVM noise floor Image suppression RX X-Pol XI XQ Y-Pol YI YQ LO input N7714A Multiport tunable laser N7786B Polarization synthesizer PM fiber M8296A Digitizer SM fiber Figure 2. Test setup for ICR modules

05 Keysight M8290A Optical Modulation and High-Speed Digitizer Test Solution - Data Sheet Test Solution for Coherent Optical Transmit & Receive Devices Coherent optical devices such as dual-polarization IQ modulators and intradyne coherent receivers need to be tested in their different development stages as well as qualified by the system integrators. The optionally available coherent optical device test software provides a turn-key solution for the characterization of these devices. One user interface provides control of all instruments through a single software package. None of the tests requires reconnecting the DUT, saving test time and reducing the uncertainty introduced by connecting and reconnecting the device. The coherent optical device test license provides: S21 magnitude and phase responses IQ skew, XY skew The setup can be customized in three different ways for transmit device testing, receive device testing and sequential testing of both, transmit and receive devices. Furthermore, it can be extended to perform system-level tests as well as wavelength and power calibration of the laser. N7786B Polarization synthesizer RX X-Pol XI XQ YI N7731A Optical switch SM fiber Y-Pol YQ M8296A Digitizer M8292A OMA M8196A AWG TX π/2 Quadrature modulator Quadrature modulator Figure 3. Example test setup for coherent optical transmit & receive devices.

06 Keysight M8290A Optical Modulation and High-Speed Digitizer Test Solution - Data Sheet M8292A Modular Optical Modulation Analyzer Specifications Table 1. M8292A Modular Optical Modulation Analyzer specifications M8292A Modular optical modulation analyzer Maximum detectable symbol rate Sample rate range Typical values 74 GBd 83 to 92 GSa/s Maximum record length per channel 512 ksa 1 ADC resolution Operating frequency range 4 Analog bandwidth, uncorrected Optical wavelength operating range Average input power monitor accuracy 8 bit 1 MHz to 40 GHz 37 GHz (3 db) 1527.60 to 1570.01 nm (196.25 to 190.95 THz) ±0.4 db Optical phase angle of I-Q mixer after correction 90 ±0.5 Relative skew after correction Image suppression 5 < ±1 ps > 30 db Error vector magnitude noise floor < 2.4% EVM rms at 2.5 GHz freq. offset 5 Sensitivity 2 Internal local oscillator (built-in) Wavelength settling time Wavelength uncertainty Sidemode Suppression Ratio (SMSR) Relative Intensity Noise (RIN) 3 External local oscillator input and output (Option 800) LO input wavelength range LO input power range LO output power < 3.5% EVM rms at 10 GHz freq. offset 6 20 dbm 14 dbm (with Option 800) < 30 s ±4.5 pm (±560 MHz), guaranteed ±2.5 pm (±310 MHz), typical 50 db 145 db/hz (10 MHz to 40 GHz) 1527.60 to 1570.01 nm 3 dbm to +17 dbm > +9 dbm 1. 128 samples are unavailable, resulting in 511872 samples per channel effectively available. 2. Valid at EVM = 32.5% for 32 GBd DP-QPSK corresponding to raw BER = 1E-3, boost mode off. 3. At maximum laser power. 4. Adjusted baseband frequency range available for signal analysis. 5. Valid at the following reference conditions Sampling rate 92 GSa/s Optical continuous wave signal at optical input port Signal power > 0 dbm Optical frequency is offset by 2.5 GHz from local oscillator frequency Vector analyzer I-Q spectrum span set to 12.5 GHz QPSK demodulation 10 GBd symbol rate PolStokesAlign set to Single Polarization KFPhaseTrack with carrier phase variance set to 1E-4 Result length set to 500 symbols Raised cosine filter selected as reference filter 25 C ±5 K environmental temperature 6. Valid at reference conditions as stated above, except for: Optical frequency is offset by 10 GHz from local oscillator frequency Vector analyzer I-Q spectrum span set to 50 GHz 40 GBd symbol rate

07 Keysight M8290A Optical Modulation and High-Speed Digitizer Test Solution - Data Sheet M8292A Modular Optical Modulation Analyzer Specifications (continued) Trigger input Typical value Input range 4 V to +4 V Threshold Range 4 V to +4 V Resolution 10 mv Sensitivity 100 mv Polarity Selectable: positive, negative, either edge Timing uncertainty 8 ns Reference clock input Input frequency range 10 MHz to 17 GHz Amplitude range 500 mv pp to 2 V pp Impedance 50 Ω (nominal) Connector type SMA (female) Reference clock output Frequency with respect to sample rate f Sa / 512 Amplitude 0.9 V pp (nominal) Impedance 50 Ω (nominal) Connector SMA (female) Table 2. M8292A maximum ratings Maximum ratings Maximum signal input power Signal input damage level External LO input power Maximum Damage level Reference clock input damage level +14.5 dbm +15 dbm +17 dbm +18 dbm 3 V pp Laser safety information All laser sources listed above are classified as Class 1M according to IEC 60825-1/2014. All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2007-06-24.

08 Keysight M8290A Optical Modulation and High-Speed Digitizer Test Solution - Data Sheet M8296A Electrical High-Speed Digitizer Specifications Table 3. M8296A electrical high-speed digitizer specifications M8296A Electrical high-speed digitizer Maximum detectable symbol rate Sample rate range Typical value 74 GBd 83 to 92 GSa/s Maximum record length per channel 512 ksa 1 ADC resolution Operating frequency range 2 Analog bandwidth, uncorrected Skew between different input channels Skew between normal and complement Input amplitude ranges Input impedance Number of input channels 4 Trigger input Input range Threshold Range Resolution Sensitivity Polarity Timing uncertainty Reference clock input Input frequency range Amplitude range Impedance Connector type Reference clock output 8 bit 50 khz to 42 GHz 37 GHz (3 db), guaranteed³ < ±250 fs < ±1 ps 150 mv pp,diff 300 mv pp,diff 500 mv pp,diff 800 mv pp,diff 50 Ω (nominal) 4 V to +4 V 4 V to +4 V 10 mv 100 mv Selectable: positive, negative, either edge 8 ns 10 MHz to 17 GHz 500 mv pp to 2 V pp 50 Ω (nominal) SMA (female) Frequency with respect to sample rate f Sa / 512 Amplitude Impedance Connector 0.9 V pp (nominal) 50 Ω (nominal) SMA (female) 1. 128 samples are unavailable, resulting in 511872 samples per channel effectively available. 2. Adjusted baseband frequency range available for signal analysis. 3. Determined from a 9th order polynomial fit to the measured amplitude response. Table 4. M8296A maximum ratings Maximum ratings Damage level (single ended) Damage level 0.9 V pp / 3 VDC 3 V pp

09 Keysight M8290A Optical Modulation and High-Speed Digitizer Test Solution - Data Sheet General Characteristics Table 5. General characteristics M8292A Modular 92 GSa/s optical modulation analyzer M8296A Modular 92 GSa/s 4-channel electrical high-speed digitizer Dimensions (W x H x D) 322.25 mm x 60 mm x 281.5 mm 322.25 mm x 30 mm x 281.5 mm Weight 3.6 kg 3.3 kg Storage temperature range Operating temperature range Humidity Operating altitude Power consumption Safety designed to EMC tested to 40 C to +70 C +5 C to +35 C 15% to 80% relative humidity, non-condensing 0 to 2000 m 100 W at 92 GSa/s IEC61010-1, UL61010, CSA22.2 61010.1 tested IEC61326-1 Form factor 2-slot AXIe 1-slot AXIe Warm-up time Recommended re-calibration interval Shipping contents Connectors Signal input Local oscillator input and output Trigger input, reference clock input and output 1 x Optical modulation analyzer module M8292A 1 x 81000xI FC/APC connector interface (3 x 81000xI for option 800) 30 minutes 2 years 1 x UK6 report 1 x UK6 report 1 x 4-channel electrical digitizer module M8296A 1 x getting started guide for the M8290A 1 x getting started guide for the M8290A 1 x RoHS addendum for photonic test and measurement products 9320-6654 1 x RoHS addendum for photonic test and measurement products 9320-6654 1 x calibration certificate 1 x calibration certificate 1 x entitlement certificate for M8290400A software package 9 μm single-mode angled 81000xI connector interface 9 μm single-mode angled 81000xI connector interface 1 x entitlement certificate for M8290400A software package 2.4 mm (female) n/a SMA (female)

10 Keysight M8290A Optical Modulation and High-Speed Digitizer Test Solution - Data Sheet Definitions Generally, all specifications are valid at the stated operating and measurement conditions and settings, with uninterrupted line voltage and in "normal mode" (boost mode off). Specifications (guaranteed) Describes warranted product performance that is valid under the specified conditions. Specifications include guard bands to account for the expected statistical performance distribution, measurement uncertainties changes in performance due to environmental changes and aging of components. Typical values (characteristics) Characteristics describe the product performance that is usually met but not guaranteed. Typical values are based on data from a representative set of instruments. General characteristics Give additional information for using the instrument. These are general descriptive terms that do not imply a level of performance.

11 Keysight M8290A Optical Modulation and High-Speed Digitizer Test Solution - Data Sheet Configure Your M8290A Coherent Test Solution Step 1: Choose OMA and digitizer modules Table 6. Module selection M8290A modules M8292A M8296A Optional modules (orderable as separate items) M8195A M8196A Step 2: Select appropriate chassis Table 7. Chassis selection Chassis M9502A M9505A Controller (mandatory) M9537A 1 Description Modular 92 GSa/s optical modulation analyzer, 2-slot AXIe Modular 92 GSa/s digitizer, 1-slot AXIe 65 GSa/s arbitrary waveform generator, 1-slot AXIe 92 GSa/s arbitrary waveform generator, 1-slot AXIe Description 1. Please reserve one slot for the embedded controller. 2-slot AXIe-1 mainframe 5-slot AXIe-1 mainframe Embedded controller, 1-slot AXIe Step 3: Add required and optional software Table 8. Software selection Software (mandatory) M8290400A 89601B-200 Description Optical modulation analyzer software Basic vector signal analysis and hardware connectivity, transportable license 1 89601B-AYA Vector modulation analysis, transportable license 1 Software add-ons (optional) M8290430A M8290440A 89601B-BHF 89601B-BHK 81195A ICR test license Coherent optical device test license Proprietary and pre-standard OFDM formats Proprietary and pre-standard, customized IQ constellation signals. Optical modulation generator software 1. Other license models are available. For details, see https://www.keysight.com/de/de/software/application-sw/89600-vsa-software/family-options.html

12 Keysight M8290A Optical Modulation and High-Speed Digitizer Test Solution - Data Sheet Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. http://www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument s lifecycle. Our comprehensive service offerings onestop calibration, repair, asset management, technology refresh, consulting, training and more helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) www.keysight.com/find/oma www.keysight.com/find/m8290a DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. Keysight Technologies, 2017 Published in USA, November 27, 2017 5992-2480EN www.keysight.com