An innovative salinity tracking device for Multiphase and Wet Gas Meter for any GVF and WLR

Similar documents
A Methodology for Efficient Verification of Subsea Multiphase Meters used in Fiscal Allocation

The Use Of Innovative Multi-Phase Flow Meters to Achieve Superior Measurement Accuracy and Reliability, While Lowering Overall Cost of Facility

Integrating & Operating A New Salinity Measurement System As Part of A Wet Gas Meter. Svein Eirik Monge Product Manager, Emerson Subsea Flow Metering

Solutions for Reliable and Accurate Measurement of Water Production in Subsea Wet Gas Fields

SUBSEA MULTIPHASE FLOW METER

R&D - Technology Development November Conference RJ, 3-4 November by Innovation Norway

Representative Subsea Sampling: A Key Enabler for Flow Assurance and Better Metering Uncertainty

Challenges with salinity measurements in multiphase flow metering

Pumps and Subsea Processing Systems. Increasing efficiencies of subsea developments

33 rd International North Sea Flow Measurement Workshop October 2015

Linear Polarisation Noise for Corrosion Monitoring in Multiple Phase Environments. (Patent Pending)

Project Experience, April 2009

Water Fraction Measurement Using a RF Resonant Cavity Sensor

Subsea Production Water Management

Mirmorax Subsea Technologies -Oil in Water Measurements for subsea applications Eivind Gransæther CEO. Mirmorax AS

Application Note 221. A New Coaxial Flow Calorimeter for Accurate RF Power Measurements up to 100 Watts and 1 GHz

A New Noise Parameter Measurement Method Results in More than 100x Speed Improvement and Enhanced Measurement Accuracy

Manual of Petroleum Measurement Standards Chapter 20.3 Measurement of Multiphase Flow

Non Invasive Electromagnetic Quality Control System

Practical Introduction to Multiphase Flow Metering

Coaxial Flow Calorimeter for Accurate RF Power Measurements up to 100 Watts and 1 GHz

Slug Flow Loadings on Offshore Pipelines Integrity

API COPM CPMA Chapter 20.X

Oil&Gas Subsea Production

Microwave Circuit Design and Measurements Lab. INTRODUCTION TO MICROWAVE MEASUREMENTS: DETECTION OF RF POWER AND STANDING WAVES Lab #2

OneSubsea Pumps and Subsea Processing Systems

The Metrology Behind Wideband/RF Improvements to the Fluke Calibration 5790B AC Measurement Standard

ClampOn, Inc. Ultrasonic Intelligent Sensors. Presented by Hans A. Wagner

Implementing FPSO Digital Twins in the Field. David Hartell Premier Oil

SPRAY DROPLET SIZE MEASUREMENT

STATUTORY INSTRUMENTS SUPPLEMENT No th June, 2016 STATUTORY INSTRUMENTS SUPPLEMENT

PRODUCTION OmniWell SUBSEA PERMANENT RESERVOIR MONITORING SYSTEM Acquire real-time data for more informed reservoir decisions and enhanced production

Design and Performance Testing of an Integrated, Subsea Compact Separation System for Deep-water Applications

Applied Technology Workshop Twin Screw Multiphase Pump. Ove Jahnsen 08 February 2005

The use of CFD to assess valve performance and operation in extreme conditions. BVAA Conference Tuesday 12 th May Alex Roff Engineering Director

OneSubsea Subsea Sampling System

Verification / validation of sub sea multiphase meters

Subsea Sampling on the Critical Path of Flow Assurance

Subsea Asia Subsea Processing. June 2008 Dennis Lim Senior Field Development Engineer

TOP OF THE LINE CORROSION COMPARISON OF MODEL PREDICTIONS WITH FIELD DATA

queensgate a brand of Elektron Technology

A Centre of Research-based Innovation Bridging Industry and Science. Erling Kolltveit, Manager

Development and Testing of an ROV-Deployed Deepwater Subsea Sampling System

ADCHEM International Symposium on Advanced Control of Chemical Processes Gramado, Brazil April 2-5, 2006

ACOUSTIC BEHAVIOR OF MULTIPHASE FLOW CONDITIONS IN A VERTICAL WELL

Fibre optic interventions enable intelligent decision making in any well. Frode Hveding VP Reservoir

AGRON / E E / MTEOR 518 Laboratory

DATASHEET SMT172. Features and Highlights. Application. Introduction

Thermodynamic Modelling of Subsea Heat Exchangers

OIL AND WATER SEPARATION AT ITS BEST

7. Experiment K: Wave Propagation

Mauro CAPPELLI Francesco CORDELLA Massimo SEPIELLI

Radiofrequency Power Measurement

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

PEOPLE PROCESS EQUIPMENT TECHNOLOGY VALUE. Cased-Hole Services Optimize Your Well Production

Active Heating Potential Benefits to Field Development

Testing 320 kv HVDC XLPE Cable System

Wireless Ad hoc and Sensor Network Underground with Sensor Data in Real-Time

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

New measuring sensor for level detection in subsea separators

9 Moisture Monitoring

RF and Microwave Power Standards: Extending beyond 110 GHz

DavidsonSensors. Fiber Optic Sensing System Definitions. Davidson Fiber Optic Sensing System

Flow Assurance. Capability & Experience

Kit for building your own THz Time-Domain Spectrometer

eye in hell CD 3002 Sensor Manual

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

Nano Beam Position Monitor

CALYS 100. Field precision documenting multifunction calibrator

2-10 µm Diameter Water Droplets in Mineral Oil Emulsion Production

Acoustic Velocity Independent Ultrasonic Flow-Meter

Mm-wave characterisation of printed circuit boards

Subsea Processing. Largest contributor to Increased Recovery Enabler for difficult production regimes:

CALYS 75. Field documenting multifunction calibrator

Standard Horizontal Subsea Trees. Integrated offshore offering for reliable, high-quality, and capitalefficient

Developments in Electromagnetic Inspection Methods I

Interface Measurement Technology

PLANAR R54. Vector Reflectometer KEY FEATURES

EE 3324 Electromagnetics Laboratory

MICROWAVE ENGINEERING-II. Unit- I MICROWAVE MEASUREMENTS

Testo SuperResolution the patent-pending technology for high-resolution thermal images

New Detectors for X-Ray Metal Thickness Measuring

Position Accuracy Machines for Selective Soldering Fine Pitch Components Gerjan Diepstraten Vitronics Soltec B.V. Oosterhout, Netherlands

FIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 22.

International Journal of Engineering & Computer Science IJECS-IJENS Vol:13 No:03 1

Analysis of Multiphase Flow Instabilities in the Girassol Deep Offshore Production System

MICROWAVE AND RADAR LAB (EE-322-F) LAB MANUAL VI SEMESTER

AC Resistance Thermometry Bridges and their Advantages By Peter Andrews

Use of fibre sensors for temperature measurement in subsea infrastructure to monitor flow-loop cooldown

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Background Why? What are the business drivers? Subsea, Surface or FLNG? Subsea Dehydration & The SubCool Hybrid Concept

Multiphase Metering and Well Rate Estimation Methods for Field Allocation

PRECISION TEMPERATURE SYSTEMS. Compact Modular and Upgradeable Thermometry Measurement Systems

LECTURE 10. Dr. Teresa D. Golden University of North Texas Department of Chemistry

LM1042 Fluid Level Detector

DIELECTRIC RESONATORS

Goals of the Lab: Photodetectors and Noise (Part 2) Department of Physics. Slide 1. PHYSICS6770 Laboratory 4

Design and experimental realization of the chirped microstrip line

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

Transcription:

An innovative salinity tracking device for Multiphase and Wet Gas Meter for any GVF and WLR D r Bruno PINGUET, Schlumberger D r Cheng Gang XIE, Schlumberger D r Massimiliano FIORE, Schlumberger 1 INTRODUCTION In the multiphase metering business, there is an increasing market need to monitor changes in the produced water salinity - taking place due to formation water breakthrough and/or water injection, or commingled oil-gas production, posing challenges to some multiphase flow meters with technologies which are more prone to salinity change than others. Nucleonic fraction measurement has weak sensitivity to salinity change specifically when the WLR is below 30%. Meanwhile there are some needs of salinity tracking for watery wells to improve water cut measurement and flow rate performance in some limited and specific cases. Extensive experimental testing carried out in 2002 and redesign and re-evaluation for current topside market have demonstrated that microwave sensors, based on open coaxial probe operating in the GHz-range, are able to detect rapidly early-water production and track salinity changes by measuring electrical conductivity of the water contained in a flowing mixture of oilgas-water fluid. This paper presents the results of this innovative Topside Conductivity Probe deployed and tested in very controlled flowloop facilities over a wide range of multiphase and wet gas flow conditions at different salinities. The performance is stated in terms of online brine conductivity and salinity detection accuracy. The technical part of the paper will explain that the innovation comes from a new way to process the simultaneously measured conductivity and the permittivity data of multiphase-flow mixture in the vicinity/path of the sensing probe. The interpretation of unique combination of both measurements allows the sensor to work even in what is called oil continuous phase and presents a breakthrough in the salinity monitoring business by allowing to detect the first water droplet production when the well was only producing hydrocarbon (liquid and gas) earlier. Additionally, the measurement is enhanced by a unique environmental correction (ambient temperature change, electronic drift, and other ) and a way to compensate it for this fluctuation. 2 Vx TECHNOLOGY The Vx Technology is the simplest multiphase flow meter (MPFM) combination on the market and is composed of a Venturi section and a fraction meter based on multi-energy gamma-ray source with a dedicated detector on the opposite side of the pipe. Each element has a specific role in the flow rate calculations process and all measurements are taken at the throat of the Venturi (the smallest section of the pipe, Fig.1). 1

Fig. 1 The Representation of the Vx technology with Venturi, gamma rays source, and the nuclear detector. 2.1 The True Problem about Salinity Measurement versus Vx technology The Vx technology robustness in the nucleonic fraction measurement is based on the weak sensitivity to salinity change specifically when the WLR is below 30-50%. Fig.2 shows the effect of salinity change on the WLR measurement without applying any salinity correction. Fig. 2 Effect of the salinity change [%] on the WLR measurement if no correction is applied for any GVF The strong argument about the robustness of the fraction measurement is nowadays balanced by some specific needs. Schlumberger has been looking into how to handle such situation and what have been the real market needs since 2002. It came out that the interest 2

was to detect the first droplets of water in wet gas conditions (e.g. for meeting subsea flowassurance needs). This poses a measurement challenge when the flow is essentially hydrocarbon (gas). Additionally, the monitoring of salinity change could have some interests for the need of tracking for formation/injection water breakthrough in wells, or cleanup and improving water cut measurement and flow rate performance. 3 SALINITY MEASUREMENT & THE WAY TO ADDRESS IT 3.1 Background Experience To be very sensitive to the presence of water, changes in water fraction and in water salinity it is then necessary to use electromagnetic measurement in the GHz (microwave) range. Xie and Pinguet [1] have shown the impact of salinity change with such technique of measurement and then the difficulty to guarantee accurate WLR. On the other hand, electromagnetic sensing could be used as a complementary method to the standard Vx meter to provide correction to the Vx technology, if the salinity change is not detectable with the Vx technology but can affect the measurement quality with the standard Vx data processing. Schlumberger has been patenting in the measurement methods based on electromagnetism since the early days of the company and then has constantly been using it for the downhole tools. The main issue for multiphase flow measurement at surface (seabed or topside) is to find an adequate location for this measurement to be sensitive to the presence of water in any conditions (very high GVF >95%, low WLR range in the oil continuous phase, and capture the first droplet of water co-produced from oil or gas well). The key element is then to position at the right place for this additional sensor. It is also necessary to be cost effective and be capable of either providing a standalone solution or an add-on retrofittable to the multiphase flowmeter. Schlumberger, as early as 1996, has looked at few solutions in multiphase domain and took several patents. All main multiphase flowmeter on the market today use a blind tee for several reasons and the main one to be independent of the upstream flow configuration and condition the flow to achieve high accuracy measurement. It was also demonstrated by E. Vethe et al. [2] that the blind tee is a relevant place for fluid sampling. Videos and CFD were used to position carefully a sampling device taking representative liquid and gas samples from a multiphase flow. It was naturally the relevant place to focus a bit more in details on the possibility to set additional sensors. The pictures in Fig.3 show clearly that even with extremely high GVF in average there is a liquid-rich region present either in the bottom a blind tee or at the end of the blind tee. Fig. 3 Blind Tee: A compulsory element of the 3-phase Multiphase and Wet gas Meter One of the main discovery of the extensive study of the blind tee functionality was to identify places were high liquid enrichment is present for any GVF. The figure 4 below shows the 3

liquid enrichment efficiency versus GVF - a logarithmic scale has been selected on the y-axis. At low GVF, more than 60% of liquid are added inside a sampling bottle versus the line conditions, and this goes above 5,000% at extremely high GVF (98%). This highlights that the design to collect the liquid is extremely robust and works on the full range of GVF. Fig. 4 Results showing the performance of collecting enriched liquid sample at different GVF Focusing on the liquid sample and looking at the representativeness of the WLR within the limit given show that most of the data are well within a standard deviation of 2.5% (Fig.5). The uncertainty on the WLR is independent of the GVF. This means it is possible to verify the performance with a relevant WLR/BSW reference from this sample. Fig. 5 Subset of data showing the comparison of the local WLR measurement versus global WLR measurement (also called Reference) 4

3.2 A local measurement of the permittivity and conductivity To make a differentiation between condensed and formation water (Water Breakthrough) requires a technique of measurement capable of having a large contrast between water and hydrocarbon. The use of the electromagnetic measurement is based on the large contrast between water and hydrocarbon (gas or liquid) from permittivity and conductivity point of view. The main drivers for the development of the brine conductivity measurement is to measure in terms of a complex permittivity in GHz range which leads to mixture conductivity and permittivity and their ratio (indicative of flow-mixture loss factor), then assuming a given salt composition it will provide an equivalent salinity. The right way to progress in the detection of the water is then not to try to measure the complex permittivity or attenuation of the electromagnetic wave over the full pipe cross section. Indeed, going in this direction of a global measurement does not help to solve the problem when there is a large amount of gas present with tiny amount of liquid; the resulting complex permittivity output is still very low due to the presence essentially of gas, leading to an improper complex permittivity measurement of the liquid and its water-phase conductivity. Again, it is the position of the probe in a relevant place which is instrumental to the success in such conditions. The measurement concept with electromagnetism put in practical industrial application is based on a patent established more than 10 years ago and on the use of reflection signal on an open-ended coaxial probe of an electromagnetic wave. There are several advantages to this system, first it is a compact solution and then it is well known in the literature. The specially designed high-pressure and high-temperature withstanding probe is compact and has a diameter of less than 10 mm. The front aperture of the probe will be in contact with and face the incoming flow, and has an investigation depth of a few millimeters ahead of the probe (Fig. 6). ~2mm Fig. 6 Electromagnetic Probe for TOPSIDE Solution (left side) and some dimensions with a probe slightly inside the main pipe with a depth of investigation of a few mm and the concept of measurement by reflection (right side) The electrical field created by the coaxial probe will be modified by any droplet of oil and water and will create a reflected electromagnetic wave that contain the electrical impedance (hence complex permittivity) information about the type of fluids present at that time in front of the probe. Measuring the incident wave and the reflected one by using a thermally stablized 5

microwave electronics circuit it is possible to calculate their ratio - the complex reflection coefficient. The flow-mixture complex permittivity (and their ratio or loss factor) used to determine brine electrical conductivity (salinity) can be derived from the measured reflection coefficient. A classical calculation based on a a bilinear model (relating complex permittivity and reflection coefficient) is made with some additional factory calibration with few known fluids, the complex permittivity can be calculated under the following form: ' " m i : The real part is known as the permittivity (or to simplify here to a dielectric constant) : The imaginary part is largely proportional to the electrical conductivity given the microwave measurement frequency 3.3 Local Measurement & the Innovative Data Processing Based on the above explanation, it is then possible to produce in real-time a signal to spot the water presence inside the flow. This is presented on the Fig. 7 versus time (30 seconds recording), where the GVF is equal to 99.5% or only 0.5% of liquid, with a WLR ~ 25% and the Water Volume fraction (WVF) is equal to 0.125%=1250ppm. The spikes seen on both graphs represent the water passing in the vicinity of the probe or hitting the probe. Fig. 7 Permittivity (left) and Conductivity (right) Measurement versus time (30 seconds) with GVF=99.5%, WVF=1250ppm, and WLR=25% The same recording is presented with now WVF=0.0337%=337ppm but a WLR~34% and a GVF=99.9%. It can be noted that more droplets are present in this flow now. Fig. 8 Permittivity (left) and Conductivity (right) Measurement versus time (30 seconds) with GVF=99.9%, WVF=337ppm, and WLR=33.7% 6

The innovative way to handle the microwave measurement data is to look at them not versus time but in terms of cross-plotting conductivity vs. permittivity (see Fig. 9). The ratio of mixture conductivity over permittivity (indicative of the loss factor) is constant for a fixed salinity (at a fixed temperature). Through the use of an interpretation algorithmic method not explained here it is capable of providing the ratio of water conductivity over water permittivity (i.e. 100% of water) and then access to the salinity, over a wide range of multiphase-flow GVFs and WLRs. The originality of the solution is due to the local measurement at the blind-tee location of the fluids close to the probe aperture and the fact that the system is not looking into the entire flow but a subset which is full of liquid-rich fluids. Even though the pipe-averaged liquid holdup is probably very low (and with oil being the continuous phase), the local liquid (water) holdup is much higher with less presence of the gas phase. Fig. 9 Data processing to get access to the salinity in real-time by looking into cross-plot of conductivity and permittivity (upper), and below showing the varation of mixture conductivity recorded versus time. 3.4 Local Measurement & Blind Tee The last need to solve our initial problema was to find a way to see the first droplets. As we know in Wet gas conditions the Froude number is usually high and then the liquid droplets are most of the time suspended in the gas flow, if this is not the case then by gravity the liquid will be in the bottom of the horizontal pipe and then the problem to handle is much easier based on the know-how from CFD and high speed flow-visualization camera video recording collected over the years about the blind tee effect. The appropriate way for early water droplet detection is then to have the open-coaxial probe facing the incoming flow and set in a relevant place at the back-flange of the blind-tee inlet (Fig.10 right). Fig. 10 (left) shows the Topside Conductivity Probe module upgraded on a Vx Spectra meter with its own acquisition system (modular in the final offering to customers). 7

Fig. 10 Right: the typical probe setting inside the blind-tee; left: upgrade of an MPFM with the modular conductivity probe system. 4 SALINITY MEASUREMENT AND THE TRUE PROBLEM 4.1 Salinity measurement in stable flow conditions The variation in the water-rich multiphase-flow mixture complex-permittivity ratio is dominated by the water-conductivity change. This is presented, Fig. 11, based on the DNV-GL flow loop test results as the cross-plot of the measured (time-averaged) mixture-conductivity vs mixtureconductivity. We can observe a very stable mixture conductivity-to-permittivity ratio for each fixed brine salinity (brine conductivity), at least down to conductivity of 0.5 S/m or permittivity of 8. This is the key to obtain robust brine-conductivity/salinity estimate even in bulk oil continuous phase or reaching wet-gas phase flow conditions. Fig. 11 Cross-plot of time-averaged (between 10 to 25 minutes) mixtureconductivity vs mixture-permittivity for all tested three salinities at DNV-GL. The typical GVF-WLR phase diagram is presented in Fig.12 with the same color coding as those shown on the Fig. 11 to give an idea about the flow conditions. 8

Fig. 12 DNV-GL test matrix in terms of GVF vs WLR, and NaCl brine salinity range. In Fig. 13, the measured salinities are plotted vs. the average WLR, superimposed with the calculated (for Vx) brine-salinity error bands of equivalent ±2%-WLR-error. We can observe that there is a decreasing sensitivity, with decreasing WLR, of the Vx WLR measurement accuracy to the changes in the (NaCl) brine salinity but way within 2% target. Fig. 13 The time-average of brine salinity vs WLR for all 3 tested salinities, with calculated (for Vx) brine-salinity error bands shown of equivalent ±2%-WLR-error (absolute). 9

4.2 Salinity measurement in dynamic change conditions The demonstration of the salinity tracking during the change of salinity was the next step to ensure the entire solution was satisfactory in dealing with dynamic change. Among the multiple tests made on flowloops, it is presented in Fig. 14 the tracking of the water salinity change from fresh water to salinity close to 6kppm. It can be seen clearly that the measurement is close to 0 most of the time, then the injection of salty water is made, this is done when the flowloop is still running and then a breakthrough of high salinity is detected before the mix of the fresh and salty water is stabilizing through recirculation inside the flowloop and stabilizing around 6kppm. Fig. 14 CEESI salinity change from 0 to 6kppm over few minutes. Another recording with a salinity change this time from 6kppm, to 27kppm and to 55kppm. The two steps in salinity introduction can be seen in Fig. 15 and the decay from the peak value on the last part is when the entire flowloop and all section with still fresh water trapped inside have been opened to mix entirely the water to a stable salinity. Fig. 15 CEESI salinity change from 6 to 30 to 55kppm over few minutes. 10

5 CONCLUSION South East Asia Flow Measurement Conference The microwave open-coaxial probe used to provide brine conductivity is based on the simultaneously measurement of the mixture conductivity and the (dielectric) permittivity of multiphase-flow mixture in the vicinity of probe s front aperture, by measuring the amplitudeattenuation and phase-shift of reflected microwave signals. The probe is mounted in a welldefined place inside a blind-tee to ensure the early water detection (first droplet of water) and with a place collecting enough liquid even when the GVF is extremely high (>99%) From the multiples flow loop tests, we can conclude that stable and accurate multiphase-flow fluid property measurements have been achieved to meet brine conductivity (salinity) accuracy requirement. The brine conductivity is quantitatively measured within ±5% (or ±0.5 S/m) for WLR>~25%, GVF up to 99%. The corresponding brine-salinity calculation is also within ±5%. A mix of quantitative and qualitative measurement for lower WLR (as low as 2%) was achievable but as indicated earlier in this low WLR range the nucleonic fraction meter is weakly sensitive to salinity variation and provide good performance already as a standalone solution. The use of a unique environmental (thermal-drift) correction based on a stablised measurement is an enabler of high accuracy. In this challenging condition of GVF above 95% and WLR in the oil continuous phase (WLR <40%) the Vx technology is proposing a unique solution. A careful evaluation of the performance is ongoing to state the right value at such very low WLR. The brine conductivity probe solution is proposed either as a standalone solution or for enabling higher accuracy Vx WLR measurement by using Conductivity probe salinity-tracking input to the Vx technology. 6 REFERENCES [1] Xie CG., PINGUET B.: Emulsion and Impact on Multiphase Flow Meter technologies 5 th Americas Workshop (Kuala Lumpur, March 2010). [2] VETHE E., PINGUET E., SMITH M., SMITH G., SBORDONE A., NIGHSWANDER J.: Reducing Uncertainty from PVT by Representative Sampling Subsea OTC 23340 Offshore Technology Conference Houston, April 2012. 11