Data sheet Energy meter with integrated S-Bus interface

Similar documents
3-Phase Energy meter for high current measurement converter with Serial S-Bus interface

3-Phase Energy meter with Serial S-Bus interface

3-Phase Energy meter with serial S-Bus interface

3 phase energy meters with integrated Serial Modbus interface

Single phase energy meter with Serial Modbus interface

Three-phase energy meter for transformer connection with S0 pulse output

Data sheet AWD3 3-phase, bidirectional energy meter for current converter metering with integrated S0-output Controls Division

S0 pulse counter. with S-Bus interface. Main features: Order number. Technical Data. Mounting

3-phase energy meters with S0 pulse output

EMU Electronic AG. Jöchlerweg 4 CH-6340 Baar Switzerland Telefon +41 (0) Fax +41 (0)

Energy Management Energy Meter Type EM340

Energy Management Energy Meter Type EM111

Energy Management Energy Analyzer Type EM111

Energy Management Energy Meter Type EM112

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

MID energy meter B21 Single-phase energy meter, 65 A

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

Energy Management Energy Analyzer Type EM112

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

3-phase meter with direct connection and pulse or Modbus RS485 output

INDUSTRIAL+COMMERCIAL ZMD310AT/CT TECHNICAL DATA. Measurement Accuracy. Measurement Behaviour. MID-specific data. Current (for Class B) General

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Energy Management Energy Meter GM3T E GM3T-RS485 E

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

INDUSTRIAL+COMMERCIAL ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA. IEC-specific data. Current. Measurement Accuracy. Measurement Behaviour.

Energy Management Energy Meter GM3D

7E Series - Energy meter. Features PTB 1

Power-meters three-phase

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

Energy Management Energy Meter Type EM21 72R Retro-Fit

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Single phase meter with direct connection and pulse or Modbus RS485 output

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

Environmental Influences. Display. Inputs and Outputs. Electromagnetic Compatibility. Communication Interfaces. Insulation Strenght.

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR. Technical Data

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

COUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual. en/countis-e2x

Power Meter Series PM3200 Functions and characteristics

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG310AR/CR. Technical Data

Energy Management Energy Meter Type EM110

Energy Management Energy Analyzer Type EM270-72D

EM-72 Electricity Meters for Current Transformers

Introduction DIN rail mounted electricity meters

KE-N80. Item: kg/pc unit Item No. KE-N80 three phase Energy Meter for direct connection 80A 0, DIN rail 35mm

C series Product brief

Energy Management Energy Meter Type EM110

Energy Management Energy Analyzer Type EM210 MID

Assembly of Contacts 700-FS A 3 A U23. Function Contact Outputs Time Ranges Supply Voltages All functions: Z12 12V DC

Energy Management Energy Analyzer Type EM280-72D

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

Measuring Instruments. Measuring Instruments

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Energy Management Energy Analyzer Type EM210

HVR. Lead Wire Length (H, mm)

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Multimeter 500CVD21 RTU500 series

COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

INDUSTRIAL+COMMERCIAL ZMD400AR/CR, ZFD400AR/CR TECHNICAL DATA. Frequency. IEC-specific data. Current. Measurement Accuracy.

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

Electronic timer CT-TGD.22

Technical features table for miniature circuit-breakers SH 200 Series

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Technical Data Sheet AMIK 300 / 301

Sunways Solar Inverters NT 2500, NT 3000, NT 3700, NT 4200 and NT 5000 AC output: 2.5 to 5.0 kw

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Type: DILM40(RDC24) Article No.:

AMIK 200 / 201 Technical Data Sheet

Technical Data Sheet. x1000. kwh R Y B

38 Series - Relay Interface Modules A

Solid-state Twin Timer

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Accessories. Accessories

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

MT372 Three-phase electronic meter with built-in modem or RS485 communication interface

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

Electronic timer CT-SDD.22

Solid-state Timer H3DS

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Current Transducer CTSR 1-P = 1A

Transcription:

Data sheet Energy meter with integrated S-Bus interface Controls Division Bus AWD3 Energy meters with an integrated S-Bus interface allow direct reading of all relevant data, such as energy (Total and partial), current and voltage for every phase and active and reactive power for every phase and for the three phases. Main features: 3-phase energy meter, 3 230 / 400 VAC 50 Hz Measurement through a current transformer up to 1 500 A Display of active power, voltage and current for every phase Display of active power for all phase S-Bus Interface to query the data Reactive power for every and/or all Phase available through interface Up to 254 meter can be connected to the S-Bus Interface 7-digit display Lead seal possible with cap as accessory Accuracy class B according to EN50470-3, accuracy class 1 according to IEC62053-21 Order Number: Standard Version: AWD3D5WS00C2A00 MID Version: AWD3D5WS00C3A00 Technical data Precision class Operating voltage Power consumption Counting range Display Display without mains power B according to EN50470-3, class 1 according to IEC62053-21 3 230 / 400 VAC, 50 Hz Tolerance 20% /+15% Active 0.4 W per phase 00 000.00 99 999.99 100 000.0 999 999.9 LCD backlit, digits 6 mm high Capacitor based LCD max. 2 times over 10 days Mounting Mounting Terminal connections main circuit Terminal connections control circuit Insulation characteristics On 35 mm rail, according to EN60715TH35 Conductor cross-section 1.5 16 mm 2, screwdriver Pozidrive no. 1, slot no. 2, torque 1.5 2 Nm Conductor cross-section max. 2.5 mm 2, screwdriver Pozidrive no. 0, slot no. 2, torque 0.8 Nm 4 kv / 50 Hz test according to VDE0435 6 kv 1.2 / 50 µs surge voltage according to IEC255-4 2 kv / 50 Hz test for interface Device protection class II Ambient temperature 25 +55 C Storage temperature 30 +85 C Relative humidity EMC/interference immunity 95 % at 25 +40 C, without condensation Surge voltage according to IEC61000-4-5 at main circuit 4 kv at S-Bus interface 1 kv Burst voltage according to IEC61000-4-4, at main circuit 4 kv at S-Bus interface 1 kv ESD according to IEC61000-4-2, contact 8 kv, air 15 kv measurement Reference/max. current Starting/minimum current Converter ratio Pulses per Standard Version: LCD Display MID Version: LED 5 1500 A I ref = 5 A, I max = 6 A I st = 10 ma, I min = 0.05 A 5 : 5 50 : 5 100 : 5 150 : 5 200 : 5 250 : 5 300 : 5 400 : 5 500 : 5 600 : 5 750 : 5 1000 : 5 1250 : 5 1500 : 5 10 Imp/ 10 Imp/

82 Error indication Example: connection error at L3 Example: connection error at L1 and L3 10 10 Dimensioned drawings 70 70 57,7 57.7 22.7 22,7 31 62 30.5 30,5 9 9 4,5 4.5 27 68 AWD3D5WS10 69,5 69.5 82 45 35 11 4.5 4,5 6 7 55 x 11.7 11,7 = (58,5) [58.5] 6 Display elements, direct measurement *10 imp/ only for standard version * T1 total Indicates total consumption T1 part Indicates partial consumption This value can be reset Indicates the setting for the current transformer ratio When bridge Z1-Z2 is open, the transformer ratio can be adjusted under menu item: P (kw) Indicates the instantaneous output per phase or for all phases U (V) Indicates voltage per phase I (A) Indicates current per phase 10 Imp/ Pulsates according to the amount of used power Indicates the unit for display of consumption (only for standard version) L1 / L2 / L3 Whenever the display shows P, U, I or Error, the corresponding phase will be indicated Error When phase is absent or current direction is wrong. The corresponding phase will also be indicated. 2

Wirings Diagram D /D Saia S-Bus, pair of wires, twisted max. 1200 m L1 L2 L3 N (PEN) Fuse: T 250 ma (3 ) Technical data S-Bus Bus system Saia S-Bus Transmission rate 1 200-2 400-4 800-9600-19 200-38 400-57 600-115 200. The transmission Baud rate is automatically detected Transmission mode Data Bus length (max.) 1200 m (without repeater) Response time: (to system response) Write: 60 ms Read: 60 ms The secondary, mains current transformer connection has to be connected to the phase to be measured and therefore the transformer don t have to be grounded. The Interface works only if the Phase 1 is connected. The communication is ready 30 s after the Power On The use of Energy meter in Bus with intensive communication could reduce the performance of the Bus Refresh Time for the Data is 10 s. For this reason one energy meter should be not polled faster as 10 s. 254 Devices could be connected to the S-Bus. Over 128 Devices, a repeater should be used. The Interface don t have a terminal resistor, this should be provided external. For a description of the used Registers please look at the Register Page Data transmission: Only «read/write» register instructions are recognized. Only one register can be written at a time. The device will respond «NAK» if more than 1 register is written. Up to 10 Registers could be read at a time. The device will respond «NAK» if more than 10 registers are read. The device will not respond to any unknown query. The device has a voltage monitoring system. In case of voltage loss, registers are stored in EEPROM (transmission rate» etc.) Change the S-Bus address direct on device: To modify the S-Bus address, press 3 sec. on touch In menu, increase address by 10, increase by 1 Once the address is selected wait for the root menu to come back 3

Menu to display the value on LCD Start T1 total T1 partial (T1 part) Ratio Current Transformer () >3s 5:5 250:5 750:5 50:5 300:5 1000:5 AWD3D5WS00C_A00 Instan. Power (P) >3s 100:5 400:5 1250:5 5 1500 A 150:5 500:5 1500:5 200:5 600:5 Voltage (U) Current (I) Start 4

Register The following Registers are available. For The pilot, different Register are not implemented and will give 0 as answer. All values are in HEX. R Read Write Description Unit or Value 0 X Firmware-Version Ex: «11»= FW 1.1 1 X S-Bus com. number of supported registers will give «41» 2 X S-Bus com. number of supported flags will give «0» 3 X Baudrate BPS 4 X Not used will give a «0» 5 X Type/ASN Funktion will give «AWD3» 6 X Type/ASN Funktion will give «D5WS» 7 X Type/ASN Funktion will give «00C» 8 X Type/ASN Funktion will give 9 X HW Vers. Modif Ex: «11»= FW 1.1 10 X Not used will give a «0» 11 X Not used will give a «0» 12 X X Not used will give a «0» 13 X X Not used will give a «0» 14 X Status/Protect 15 X S-Bus Timeout ms 16 X X S-Bus Address «0» = no Problem «1» = Problem with last communication request 17 X Error Flags 0: No error 1: Error Phase 1 2: Error Phase 2 3: Error Phase 1 and 2 18 X Current transformer ratio Ex: Transformer 100/5 give 20 19 X Tariff flag 20 X WT1 total Counter Energy Total Tarif 1 21 X X WT1partial Counter Energy partial Tarif 1 Any value written reset the counter 0 is Tariff 1 4 is Tariff 2 22 X Not used will give a «0» 23 X X Not used will give a «0» 24 X 25 X 26 X 27 X URMS phase 1 Effective Voltage of Phase 1 IRMS phase 1 Effective Current of phase 1 28 X cos phi phase 1 29 X 30 X 31 X 32 X PRMS phase 1 Effective active Power of phase 1 QRMS phase 1 Effective reactive power of phase 1 URMS phase 2 Effective Voltage of Phase 2 IRMS phase 2 Effective Current of phase 2 33 X cos phi phase 2 34 X 35 X 36 X 37 X PRMS phase 2 Effective active Power of phase 2 QRMS phase 2 Effective reactive power of phase 2 URMS phase 3 Effective Voltage of Phase 3 IRMS phase 3 Effective Current of phase 3 38 X cos phi phase 3 39 X 40 X PRMS phase 3 Effective active Power of phase 2 QRMS phase 3 Effective reactive power of phase 3 PRMS total Effective active Power of all phase QRMS total Effective reactive power of all phase 10-1. (multiplier 0,1) Ex: 00912351= 0091235,1 10-1. (multiplier 0,1) Ex: 00912351= 0091235,1 V Ex: 230 = 230 V A / Except. 5/5 = 10-1 A Ex: 145 = 145 A 10-2 (multiplier 0.01) Ex: 67 = 0.67 V Ex: 230 = 230 V A / Except. 5/5 = 10-1 A Ex: 145 = 145 A 10-2 (multiplier 0.01) Ex: 67 = 0.67 V Ex: 230 = 230 V A / Except. 5/5 = 10-1 A Ex: 145 = 145 A 10-2 (multiplier 0.01) Ex: 67 = 0.67 4: Error Phase 3 5: Error Phase 1and 3 6: Error Phase 2 and 3 7: Error Phase 1, 2 and 3 5

Contact Switzerland and international Saia-Burgess Controls AG Bahnhofstrasse 18 CH-3280 Murten / Switzerland T +41 (0)26 672 72 72 F +41 (0)26 672 74 99 pcd@saia-burgess.com Supplied by: Product Support, Technical reference website: www.saia-support.ch P+P26/512 EN03 12. 2012 Subject to changes to technical details and figures.