Non-Contact Sensing Reduces Wear, Breakage, Downtime, and Ultimately, Cost

Similar documents
955C BRIK for Pneumatic Cylinders

Linear Measurement Solutions

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

Input Voltage. Current Draw. Output. Resolution Internal Analog Output. Linearity. Repeatability. Hysteresis +/-.02% of Full Scale. Operating Pressure

Reliable Ultrasonic Sensors

Reliable Ultrasonic Sensors

Series 957D Brik. Linear Displacement Transducer. Installation Manual. 957D-Digital Brik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE...

A02H Encoder for Vector Motor Application

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

Temposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet

Inductive linear position sensor LI400P0-Q25LM0-LIU5X3-H1151

Temposonics. Magnetostrictive Linear Position Sensors. EP2 IO-Link Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

Inductive Linear Position Sensor LI800P0-Q25LM0-LIU5X3-H1151

Temposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet

Rotary Measurement Technology Absolute Encoders, Multiturn

MS Connector: (Voltage or Current Output) Pin No. Extension Cable Function. Wire Color. MS Connector: (Start/Stop or PWM) Wire Color WIRING: + A

Temposonics. Magnetostrictive Linear Position Sensors. EP2 SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

Inductive Linear Position Sensor LI200P0-Q25LM0-HESG25X3-H1181

Temposonics. Magnetostrictive Linear Position Sensors. EP2 CANopen Data Sheet

INCLINOMETERS.

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL IO-Link Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Start / Stop Data Sheet

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable)

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

should have. The new LI series of inductive linear position

I am the new generation. Temposonics. Magnetostrictive Linear Position Sensors. R-Series V RP Profinet RT & IRT Data Sheet

Inductive Linear Position Sensor IO-Link LI100P0-Q25LM0-ELIUPN8X3-H1151

Temposonics. Magnetostrictive Linear Position Sensors. ER IO-Link Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

J1 Line APPLICATION FEATURES DESCRIPTION RUGGED-DUTY SHAFTED ENCODERS

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Temposonics. Magnetostrictive Linear Position Sensors. ER IO-Link Data Sheet

Section 11 Electronic Position Controls & Encoders

OBSOLETE A. For 24-hour Technical Assistance Call

Temposonics. Magnetostrictive Linear Position Sensors. EH Analog Data Sheet

ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS

How to Select the Right Positioning Sensor Solution A WHITE PAPER

Temposonics. Magnetostrictive Position Sensors. G-Series Linear Position Sensor Analog and Digital Pulse Outputs. Product Specification E

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Diameter (mm) Sinking. Sourcing. Drawing # Wiring Diagram # of LEDs. Ni75U-CP80-AN6X A M

Micropulse position measuring Micropulse

Temposonics. Magnetostrictive Linear Position Sensors. ER Start / Stop Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EH IO-Link Data Sheet

EMSPA LINEAR MAGNETOSTRICTIVE TRANSDUCER WITH ANALOG OUTPUT. Magnetostrictive transducer. Main characteristics. Ordering code EMSPA 1000 S 10S 10 P A

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

Sense it! Connect it! Bus it! Solve it!

Magnetically Actuated Linear Position Sensor WIM100-Q25L-LIU5X2-H1141

Temposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet

GEMCO Series Displacement Transducer

26 Endevco Isotron accelerometers

TECHNICAL DATASHEET #TDAX021901

ph or ORP Transmitter

Ultrasonic Displacement Sensor E4DA

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

Inductive angle sensor. 4-wire, analog output. Ri360P1-QR14-ELiU5X2-0,3-RS5. Rectangular, plastic Many mounting possibilities

Magnetostrictive Level Transmitter

Temposonics LF & RF Summary

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

user leaflet ABSOLUTE TTL MODULE

Measurement range. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Sensors for Vibration, Acceleration, and Shock Measurement. Product Catalog

CSG110 Strain Gauge Universal Amplifier

Operating instructions Measured signal converter for temperature sensors TP / / 2010

Thru-beam Sensors. Model SM800 Series. Ideal for small object detection

Temperature Transmitters - DIN Rail Mounted

housing length L2 mm -U B (pole reversal protection)

Temposonics. Magnetostrictive Linear Position Sensors. GB Analog Data Sheet

SMART Position Sensor, 100 and 180 Arc Configurations

Operating instructions Measured signal converter for temperature sensors. TP323x / / 2010

SHAFTED ROTARY POSITION SENSORS

Temposonics GENERATION THE NEW I AM. Magnetostrictive Linear Position Sensors. R-Series V RH EtherNet/IP Data Sheet

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

BTL-5- -M -J-DEXC-KL20

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Rotary Measurement Technology Incremental Encoders

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

HX-EP SERIES DIGITAL OUTPUT

ULTRASTAB I U Precision

MYLES-3 MAGNETIC LINEAR ENCODER SYSTEM

Online data sheet. MLG05S-0895A10802 MLG-2 Prime MEASURING AUTOMATION LIGHT GRIDS

DVC700 Series Programmable System Controller

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm. Perfect data processing I 7 I

RPE Parallel Gripper- Electric Gripper Series

Temperature Transmitters - Head Mounted

This kind of information is useful to make reliable automatic control diagnostic and supervision systems. IS VS. Diameter of cylindrical types

Penny & Giles No-Contact, Rotary Position Sensor NRH271 & NRH272

9330 Vibration Transmitter

Solid State Pressure Sensors D8M

Temposonics. Magnetostrictive Linear Position Sensors. RT4 SSI Data Sheet. Redundant SSI output High temperature rod IP68 ingress protection

Transcription:

TURCK Linear Displacement Transducers TURCK introduces a new line of linear displacement transducers (LDTs) called EZ-Track. EZ-Track is the latest offering in TURCK s continuous effort to change the shape of sensing. Based on magnetostrictive technology, the EZ-Track line will reliably operate in the harsh conditions for which TURCK products are known. With its unique features, IP 67 environmental rating, 4 to 180 inch measurement span and absolute positioning, the EZ-Track line will be sure to fit into your tough linear sensing applications. Features and Benefits Non-Contact Sensing Reduces Wear, Breakage, Downtime, and Ultimately, Cost The Q21 Series from TURCK is a line of magnetostrictive linear displacement transducers. These non-contact devices detect the position of an external magnet along the active stroke of the sensor without causing any wear on the sensor parts. Because there are no parts to wear or break, the sensors can offer better performance over a longer life than competing technologies. They offer an alternative when a continuous, absolute reading is necessary in the application. The absolute reading allows the sensor to accurately know the position at power on without the need to set up a home position. With this technology, an accuracy of +/- 0.1% of the stroke and a repeatability of +/- 0.01% of full stroke can be achieved. Fast Connections As a leading supplier of connection products, TURCK delivers the complete package. Standard, shielded 4-pin, M12x1 eurofast cables are always available from TURCK for quick connection to EZ-Track. Reliable Accurate Technology Magnetostrictive technology is when a mechanical impulse is applied to the magnetostrictive waveguide that travels the length of the sensor. The traveling pulse encounters the magnetic field produced by the slide or floating magnet assembly. The interaction of the mechanical pulse with the magnetic field produces a current pulse that is picked up by the electronic circuitry. A high speed timer measures the time between the applied mechanical pulse and the induced current pulse. This time, proportional to position, is compared to the zero and span positions established during the calibration process to scale the output. Once the position has been scaled accordingly, it is converted to an analog signal in the form of a voltage or current output. Thus giving you highly accurate, non-contact position sensing with absolutely no wear on the sensing element.

Low Profile Extrusion Housing Low Profile Housings Reduce Mounting Restrictions and Eliminate Special Mounting Fixtures The Q21 Series are housed in low profile, environmentally sealed, anodized aluminum housings. The electronics and the sensing element are incorporated into a housing that is less than 1 inch tall without the need for a can or head on the sensor to house the electronics (typical competitive devices are 2.5 times larger). By reducing the profile of the sensor, less thought has to be put into the mounting of the sensor. The Q21 Series will fit into applications where others are too bulky. Diagnostic LED An LED Indicating the Status of the Sensor Simplifies Troubleshooting and Reduces Maintenance The Q21 Series utilizes a diagnostic LED that enables the operator to understand the state of the sensor dependent upon the position of the target magnet. The LED is green when the power is on and the magnet is in an active programmed area. The LED turns yellow when the magnet moves out of the programmed area, but is still within the active stroke. The LED turns red when there is no magnet present or it is in the null or dead zones. This feature simplifies programming and troubleshooting, effectively reducing setup and maintenance time. IP 67 The Q21 Series will stand up in the harsh environments for which TURCK products are known. Downtime situations due to environmental conditions can be reduced.

Programable Stroke Programmable Zero and Span Allow Standard Sensors to Have Customized Stroke Lengths, Eliminating the Need to Stock Numerous Models The analog output of the Q21 Series is not limited to the entire length of the sensor. The zero and span settings can be programmed anywhere along its active stroke. By utilizing this feature, the user can reduce stock of the various length LDTs used in the plant by replacing them with standard sizes and programming to the specific applications. Stroke lengths are available from 4 to 180 inches. To Program the EZ-Track Sensor: 1 inch Zero setting 30 inch Span setting Short pin 2 to pin 3 to obtain Zero setting and short pin 2 to pin 1 to obtain Span setting or use TURCK s TB-LDT Programmer. 3 inch Zero setting Null Zone 3 inches 3 Foot Stroke Dead Zone 1.5 inches 26 inch Span setting Dead Zone 1.5 inches Null Zone 3 inches 3 Foot Stroke Note: When ordering a sensor, total length will be 4.5 longer to accommodate the null and dead zones. Example: LT36E will be 40.5 in total length. Various Outputs Available The Q21 Series can be ordered in a variety of analog outputs. Voltage: Current: 0 to 10 V 4 to 20 ma 10 to 0 V 20 to 4 ma 10 to 10 V 10 to 10 V Although sensors can be ordered with any of the above outputs, the units can easily be changed in the field to reverse the analog signal. Thus, one model can be used for two applications by programming the zero and span appropriately. For Quadrature outputs, consult factory.

TURCK Linear Displacement Transducers TURCK Linear Displacement Transducers Part Number Key LT 12 E - Q 21 - LU 0 X3 - H1141 Cable Type Sensor Family LT = Linear Transducer Measurement Span In inches of stroke Length Units E = Inches Housing Style Q = Low Profile Housing Height Height in millimeters Number of LEDs Output Type Voltage: 0 = 0 to 10 V 1 = 10 to 0 V 2 = -10 to 10 V 3 = 10 to -10 V Current: 0 = 4 to 20 ma 1 = 20 to 4 ma H1 = eurofast, M12x1, Metal or Plastic, Male Examples: Blank = No LEDs X3 = 3-way diagnostic LED Output Configuration LU = Voltage LI = Current LQ = Quadrature (Consult Factory) Note: Standard Lengths are 6 to 36 inch in 6 inch increments, consult factory for other lengths. Specifications Input Voltage: 10-30 VDC Current Draw: Voltage Units Current Units 80 ma max @ 10 VDC 90 ma max @ 10 VDC 35 ma max @ 30 VDC 55 ma max @ 30 VDC Output: 0 to 10 VDC 10 to 0 VDC -10 to 10 VDC 10 to -10 VDC 4 to 20 ma 20 to 4 ma Current Output - Load Impedance: (Voltage in - 4).02 (example: 10V 300 Ω) Voltage Output -Load Impedance: 1000 Ω Linearity: +/- 0.05% of stroke or +/- 0.028 inches, whichever is greater Accuracy: +/- 0.1% of stroke or +/- 0.050 inches, whichever is greater Repeatability: +/- 0.01% of full stroke or +/- 0.014 inches, whichever is greater Operating Temperature: -20 to +70 C (-4 to +158 F) Span Length: 4 to 180 inches Null Zone: 3.00 inches Dead Zone: 1.50 inches LED: Green = Power is applied and magnet is present in the programmed range Red = Fault, magnet is in the Null Zone, Dead Zone, or lost Yellow = Magnet is out of the active programmed range, but still within the active stroke area Connector: Standard 4-pin, M12x1 eurofast Agency Approvals: CE Approved Enclosure: IP 67 Shock: 40 g, 11 ms Vibration: 20 Hz to 2 khz at 10 g RMS Response Time: 50 inches or less: 1 ms updates with 5 ms setting time 50 inches or greater: 2 ms updates with 4 ms setting time

LDT Assembly and Accessories TB-LDT Programming/Test Box FM-Q21 Floating magnet: Slide magnet: Mounting brackets: Programmer/Test Box: Straight: Right angle: FM-Q21 SM-Q21 MB-Q21 TB-LDT RK 4.4T-2/S618 WK 4.4T-2/S618 TURCK USA TURCK Canada TURCK Mexico TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Phone: (763) 553-7300 FAX: (763) 553-0708 Application Support: 1-800-544-PROX (7769) CHARTWELL ELECTRONICS, INC. 140 Duffield Drive Markham, Ontario Canada, L6G 1B5 Phone: (905) 513-7100 FAX: (905) 513-7101 ICESA - MODICON Ant. Camino a Sta. Monica No. 7 San Lucas Tepetlacalco 54050 Tlalnepantla Edo. de Mexico Phone: (52) 5-397-8644 FAX: (52) 5-398-9888 Printed in USA B0310 11/01