Vector Network Analyzer Application note

Similar documents
Network Analysis Basics

For EECS142, Lecture presented by Dr. Joel Dunsmore. Slide 1 Welcome to Network Analyzer Basics.

Understanding the Fundamental Principles of Vector Network Analysis. Application Note

EXPERIMENT EM3 INTRODUCTION TO THE NETWORK ANALYZER

EE 3324 Electromagnetics Laboratory

Agilent ENA Series 2, 3 and 4 Port RF Network Analyzers

Preliminary Users Manual for the Self Contained Return Loss and Cable Fault Test Set with Amplified Wideband Noise Source Copyright 2001 Bryan K.

Agilent AN Applying Error Correction to Network Analyzer Measurements

FieldFox Handheld Education Series Part 3: Calibration Techniques for Precise Field Measurements

Vector Network Analyzer

Introduction to VNA Basics PRIMER

VSWR MEASUREMENT APPLICATION NOTE ANV004.

Vector Network Analyzers (VERY) Basics. Tom Powers USPAS SRF Testing Course 19 Jan. 2014

LA Techniques Ltd

Configuration of PNA-X, NVNA and X parameters

Radio ETI031 Laboratory Experiments 2: VECTOR NETWORK ANALYSER, ANTENNA and RECEIVER MEASUREMENTS

Vector Network Analyzers T - Series

Impedance 50 (75 connectors via adapters)

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES

Department of Electrical and Computer Engineering ECE332. Lab 3: High Frequency Measurements

Overcoming Mixer Measurement Challenges

What Makes a Good VNA?

Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

Application Note: Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

TEST & MEASURING INSTRUMENTS. Analyzer. (4 Ports) 4 Ports

ElecEng 4/6FJ4 LABORATORY MODULE #4. Introduction to Scattering Parameters and Vector Network Analyzers: Measurements of 1- Port Devices

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

Circuit Characterization with the Agilent 8714 VNA

Signal Integrity Testing with a Vector Network Analyzer. Neil Jarvis Applications Engineer

Expanding Impedance Measurement to Nanoscale:

New Ultra-Fast Noise Parameter System... Opening A New Realm of Possibilities in Noise Characterization

Experiment 10 - Power Amplier Measurements Using Vector Network Analyzer

Vector-Receiver Load Pull Measurement

PLANAR 814/1. Vector Network Analyzer

Fast network analyzers also for balanced measurements

Amplifier Characterization in the millimeter wave range. Tera Hertz : New opportunities for industry 3-5 February 2015

Advanced Signal Integrity Measurements of High- Speed Differential Channels

Keysight Technologies In-Fixture Measurements Using Vector Network Analyzers. Application Note

ME1000 RF Circuit Design. Lab 4. Filter Characterization using Vector Network Analyzer (VNA)

(a) The insertion loss is the average value of the transmission coefficient, S12 (db), in the passband (Figure 1 Label A)

PLANAR S5048 and TR5048

THz Vector Network Analyzer Development & Measurements

MEASUREMENT OF LARGE SIGNAL DEVICE INPUT IMPEDANCE DURING LOAD PULL

Network Analyzers. R3765G/3767G Series. R3765G/67G Series Network Analyzers. 300 khz to 3.8 GHz/300 khz to 8 GHz

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

application In-Fixture Measurements Using Vector Network Analyzers Network Analysis Solutions Application Note

RF Characterization Report

AV3672 Series Vector Network Analyzer

Vector Network Analyzers. Paul Coverdale VE3ICV

VSWR AND ANTENNA SYSTEMS Copyright by Wayne Miller 2018 Revision 4 page 1 of 6

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Compact Series: S5048 & TR5048 Vector Network Analyzers KEY FEATURES

What are S-parameters, anyway? Scattering parameters offer an alternative to impedance parameters for characterizing high-frequency devices.

SHF Communication Technologies AG

Agilent Technologies Gli analizzatori di reti della serie-x

NATIONAL UNIVERSITY of SINGAPORE

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B / USB-TG44A. Application Note 1: The Smith Chart. Rev. 0

CHAPTER 4. Practical Design

EXTEND YOUR REACH GHz 60-90GHz GHz

A Walk Through the MSA Software Vector Network Analyzer Reflection Mode 12/12/09

Measurements 2: Network Analysis

Hot S 22 and Hot K-factor Measurements

A Comparison of Harmonic Tuning Methods for Load Pull Systems

Advanced Test Equipment Rentals ATEC (2832)

Agilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz. Data Sheet

Bird Model 7022 Statistical Power Sensor Applications and Benefits

Power Flow and Directional Couplers

S3602C Vector Network Analyzer Datasheet

Challenges and Solutions for Removing Fixture Effects in Multi-port Measurements

Measurements with Scattering Parameter By Joseph L. Cahak Copyright 2013 Sunshine Design Engineering Services

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

PLANAR R54. Vector Reflectometer KEY FEATURES

PXIe Contents CALIBRATION PROCEDURE. Reconfigurable 6 GHz RF Vector Signal Transceiver with 200 MHz Bandwidth

Scattered thoughts on Scattering Parameters By Joseph L. Cahak Copyright 2013 Sunshine Design Engineering Services

LXI -Certified 2.4mm & 1.85mm Automated Tuners

Transmit Power Extension Power Combiners/Splitters Figure 1 Figure 2

BIRD ELECTRONIC CORPORATION

PNA Family Microwave Network Analyzers (N522x/3x/4xB) CONFIGURATION GUIDE

University of New Hampshire InterOperability Laboratory Gigabit Ethernet Consortium

MWA REVB LNA Measurements

There is a twenty db improvement in the reflection measurements when the port match errors are removed.

LXI -Certified 3.5mm, 2.4mm & 1.85mm Automated Tuners

SWR/Return Loss Measurements Using System IIA

MAKING TRANSIENT ANTENNA MEASUREMENTS

Agilent PNA Microwave Network Analyzers

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

LXI -Certified Multi-Harmonic Automated Tuners

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Attenuators, Couplers and Filters

Agilent PNA Microwave Network Analyzers

ASSIGNMENT: Directional Coupler

Application Note 5525

772D coaxial dual-directional coupler 773D coaxial directional coupler. 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler

1000BASE-T1 EMC Test Specification for Common Mode Chokes

DESCRIPTION OF THE OPERATION AND CALIBRATION OF THE MILLIMETER I/Q PHASE BRIDGE-INTERFEROMETER

Lightning D Vector Network Analyzers. Network Analysis Solutions for Design and Manufacturing. 40 MHz to 65 GHz

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

Reflectometer Series:

Experiment 12 - Measuring X-Parameters Using Nonlinear Vector Netowrk Analyzer

Microwave Circuit Design and Measurements Lab. INTRODUCTION TO MICROWAVE MEASUREMENTS: DETECTION OF RF POWER AND STANDING WAVES Lab #2

Transcription:

Vector Network Analyzer Application note Version 1.0

Vector Network Analyzer Introduction A vector network analyzer is used to measure the performance of circuits or networks such as amplifiers, filters, attenuators, cables and antennas. It does this by applying a test signal to the network to be tested, measuring the reflected and transmitted signals and comparing them to the test signal. The vector network analyzer measures both the magnitude and phase of these signals. Basic Need to Test RF Components R&D engineers need to measure these components to verify their simulation models and their actual hardware prototypes. For component production a manufacturer must measure the performance of their products so they can provide accurate specifications. This is essential so prospective customers will know how a particular component will behave in their application. Types of Devices which needs to be tested The devices which can be tested by Transcom Network Analyzer include both passive and active devices. Network analyzers can measure both linear and nonlinear behaviour of devices. Some of the devices which are being tested by our network analyzer are:

Passive Devices: Duplexers, Diplexers, Filters, Couplers, Splitters, combiners, Isolators, Circulators, Attenuators, Adaptors, Loads, Cables, Transmission Lines, Antennas and Multiplexers etc. Active Devices: RFICs, Transceivers, Tuners, Convertors, Amplifiers, Modulators and Oscillators etc. Basic Concept: Light wave Analogy to RF Energy One of the most fundamental concepts of RF network analysis involves incident, reflected and transmitted waves traveling along transmission lines. It is helpful to think of traveling waves along a transmission line in terms of a light wave analogy. We can imagine incident light striking some optical component like a clear lens. Some of the light is reflected off the surface of the lens, but most of the light continues on through the lens. If the lens were made of some lossy material, then a portion of the light could be absorbed within the lens. If the lens had mirrored surfaces, then most of the light would be reflected and little or none would be transmitted through the lens. This concept is valid for RF signals as well, except the electromagnetic energy is in the RF range instead of the optical range, and our components and circuits are electrical devices and networks instead of lenses and mirrors. Structure of Vector Network Analyzer A typical vector network analyzer contains a signal source, signal separation devices and a set of receivers. The signal source is used for generating incident signal. Signal separation devices are used for separating reference and incident signals. The incident signal stimulates Device-Under-Test (DUT), then receivers is used for receiving transmitted signal and reflect signal. With processor unit, S parameters could be obtained by calculation.

Transmission / Reflection and S-Parameter Test Sets for Measurement There are two basic types of test sets that are used with network analyzers. For transmission/reflection (T/R) test sets, the RF power always comes out of test port one and test port two is always connected to a receiver in the analyzer. To measure reverse transmission or output reflection of the DUT, we must disconnect it, turn it around, and re-connect it to the analyzer. T/R-based network analyzers offer only response and one-port calibrations, so measurement accuracy is not as good as that which can be achieved with S-parameter test sets. S-parameter test sets allow both forward and reverse measurements on the DUT, which are needed to characterize all four S-parameters. RF power can come out of either test port one or two, and either test port can be connected to a receiver. S-parameter test sets also allow full two-port (12-term) error correction, which is the most accurate form available. S-parameter network analyzers provide more performance than T/R-based analyzers, but cost more due to extra RF components in the test set. There are two different types of transfer switches that can be used in an S-parameter test set: solidstate and mechanical. Solid-state switches have the advantage of infinite lifetimes (assuming they are not damaged by too much power from the DUT). However, they are lossier so they reduce the maximum output power of the network analyzer. Mechanical switches have very low loss and therefore allow higher output powers. Their main disadvantage is that eventually they wear out (after 5 million cycles or so). When using a network analyzer with mechanical switches, measurements are generally done in single-sweep mode, so the transfer switch is not continuously switching.

Measurement by Vector Network Analyzers Vector network analyzers have the capability to measure phase as well as magnitude. This is important for fully characterizing a device or network either for verifying performance or for generating models for design and simulation. Knowledge of the phase of the reflection coefficient is particularly important for matching systems for maximum power transfer. Basic measurement which are performed by a Network Analyzer are Reflection & Transmission Parameters and S-Parameters. Reflection Parameters like VSWR and Return loss and Transmission Parameters like Insertion Loss and Attenuation can be measure with a log magnitude and VSWR format. We often want to know the impedance of the DUT. Our network analyzer can display the Smith chart, plot measured data on it, and provide adjustable markers that show the calculated impedance at the marked point in a several marker formats. We can analyse Phase and Magnitude Variation with Frequency, Deviation from Linear Phase & Group Delay for a DUT and characters unknown devices using S Parameters. Measuring S - Parameters

S11 and S21 are determined by measuring the magnitude and phase of the incident, reflected and transmitted voltage signals when the output is terminated in a perfect Zo (a load that equals the characteristic impedance of the test system). This condition guarantees that a2 is zero, since there is no reflection from an ideal load. S11 is equivalent to the input complex reflection coefficient or impedance of the DUT, and S21 is the forward complex transmission coefficient. Likewise, by placing the source at port 2 and terminating port 1 in a perfect load (making a1 zero), S22 and S12 measurements can be made. S22 is equivalent to the output complex reflection coefficient or output impedance of the DUT, and S12 is the reverse complex transmission coefficient. S11 Forward reflection Coefficient (Input Match) S12 Reverse Transmission Coefficient (Isolation) S21 Forward Transmission Coefficient (Gain or Loss) S22 Reverse Reflection Coefficient (Output Match) The accuracy of S-parameter measurements depends greatly on how good a termination we apply to the load port (the port not being stimulated). Anything other than a perfect load will result in a1 or a2 not being zero (which violates the definition for S-parameters). When the DUT is connected to the test ports of a network analyzer and we don t account for imperfect test-port match, we have not done a very good job satisfying the condition of a perfect termination. For this reason, two-port error correction, which corrects for source and load match, is very important for accurate S-parameter measurements. Displaying measurements S-parameters are essentially the same parameters as some of the terms we have mentioned before, such as input match and insertion loss. It is important to separate the fundamental definition of S- parameters and the format in which they are often displayed. S-parameters are inherently complex, linear quantities. They are expressed as real-and-imaginary or magnitude-and-phase pairs. However, it isn t always very useful to view them as linear pairs. Often we want to look only at the magnitude of the S-parameter (for example, when looking at insertion loss or input match), and often, a logarithmic display is most useful. A log-magnitude format lets us see far more dynamic range than a linear format. Measuring Reflection parameters

The input reflection coefficient Γ can be obtained directly from S11: ρ is the magnitude of the reflection coefficient i.e. the magnitude of S11: ρ = S11 Sometimes ρ is expressed in logarithmic terms as return loss: return loss = 20 log (ρ) VSWR can also be derived: Measuring Transmission parameters Transmission coefficient T is defined as the transmitted voltage divided by the incident voltage. This is the same as S21. Transmission coefficient _ is defined as the transmitted voltage divided by the incident voltage. If Vtrans > Vinc, the DUT has gain, and if Vtrans < Vinc, the DUT exhibits attenuation or insertion loss. When insertion loss is expressed in db, a negative sign is added in the definition so that the loss value is expressed as a positive number. If T is greater than 1, the DUT has gain, which is also normally expressed in decibels: Measuring Phase We know insertion phase versus frequency is a very important characteristic of a component, let s see how we would measure it. Looking at insertion phase directly is usually not very useful. This is because

the phase has a negative slope with respect to frequency due to the electrical length of the device (the longer the device, the greater the slope). Since it is only the deviation from linear phase which causes distortion, it is desirable to remove the linear portion of the phase response. This can be accomplished by using the electrical delay feature of the network analyzer to cancel the electrical length of the DUT. This results in a high-resolution display of phase distortion (deviation from linear phase). Measuring group Delay Another useful measurement of phase is group delay. Group delay is a measure of the time it takes a signal to pass through a network versus frequency. It is calculated by differentiating the phase response of the device with respect to frequency, i.e. the rate of change of phase with frequency: The linear portion of phase is converted to a constant value typically, though not always, representing the average time for a signal to transit the device. Differences from the constant value represent deviations from linear phase. Variations in group delay will cause phase distortion as a signal passes through the circuit. When measuring group delay the aperture must be specified. Aperture is the frequency step size used in the differentiation. A small aperture will give more resolution but the displayed trace will be noisy. A larger aperture effectively averages the noise but reduces the resolution. Measuring Gain Compression using Power Sweep The most common measurement of amplifier compression is the 1-dBcompression point, defined here as the input power1 which results in a 1-dB decrease in amplifier gain (referenced to the amplifier s small signal gain). The easiest way to measure the 1-dB-compression point is to directly display normalized gain (B/R) from a power sweep. The flat part of the trace is the linear, small-signal region, and the curved part on the right side corresponds to compression caused by higher input power. Vector-Error Correction or Calibration Vector-error correction is the process of characterizing systematic error terms by measuring known calibration standards, and then removing the effects of these errors from subsequent measurements. 1. One-port calibration is used for reflection measurements and can measure and remove three systematic error terms (directivity, source match, and reflection tracking). 2. Full two-port calibration can be used for both reflection and transmission measurements, and all twelve systematic error terms are measured and removed. Two-port calibration usually requires twelve measurements on four known standards (short, open - load-through or SOLT). Some standards are measured multiple times (e.g., the through standard is usually measured four times). The standards themselves are defined in a calibration-kit definition file, which is stored in the network analyzer.

Transcom network analyzers contain all of the calibration-kit definitions for our standard calibration kits. In order to make accurate measurements, the calibration-kit definition MUST MATCH THE ACTUAL CALIBRATION KIT USED! If user built calibration standards are used (during fixture measurements for example), then the user must characterize the calibration standards and enter the information into a user calibration-kit file.

Transcom Vector Network Analyzers T4 USB VNA offers wide dynamic range, low noise level, high resolution scanning with laboratory and research grade performance. T4 covers frequency range of 1MHz to 4GHz with 2-port and 2-pass that competitive with most of the bench-top VNAs on the market. T4 is suitable for laboratory, manufacturing and many other safety testing environment. T5000 Series bench-top vector network analyzer offers the high RF performance, wide frequency range and versatile functions. The T5000 series is the economic solution for manufacturing and R&D engineers evaluating RF components and circuits for frequency range up to 8GHz. T5845A is a built-in multiport test set new generation of multiport matrix vector network analyzer developed by Transcom Instrument Co.Ltd. It can be widely applied to the research, development and test of RF devices in the fields of communication, medical care, scientific research and electronics. The instrument has made a breakthrough in conventional multiport test scheme of 2/4 port VNA+matrix switch. It can carry out parallel test on DUT with 10 ports under standalone operation, thereby greatly improving test efficiency and reducing test cost and time. More information about our Test & Measurement devices can be obtained from our website www.transcomwireless.com