DESIGN OF BIO-POTENTIAL DATA ACQUISITION SYSTEM FOR THE PHYSICALLY CHALLENGED

Similar documents
ELG3336 Design of Mechatronics System

DESIGN AND IMPLEMENTATION OF EMG TRIGGERED - STIMULATOR TO ACTIVATE THE MUSCLE ACTIVITY OF PARALYZED PATIENTS

CHAPTER 7 INTERFERENCE CANCELLATION IN EMG SIGNAL

Real Time Multichannel EMG Acquisition System

EDL Group #3 Final Report - Surface Electromyograph System

CHAPTER 7 HARDWARE IMPLEMENTATION

WIRELESS ELECTRONIC STETHOSCOPE USING ZIGBEE

Available online at ScienceDirect. Procedia Computer Science 42 (2014 )

GENERATION OF SIGNALS USING LABVIEW FOR MAGNETIC COILS WITH POWER AMPLIFIERS

BME 405 BIOMEDICAL ENGINEERING SENIOR DESIGN 1 Fall 2005 BME Design Mini-Project Project Title

Wireless Transmission of Real Time Electrocardiogram (ECG) Signals through Radio Frequency (RF) Waves

Design of PID Control System Assisted using LabVIEW in Biomedical Application

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

An investigation of fatigue phenomenon in the upper limb muscle due to short duration pulses in an FES system

A Body Area Network through Wireless Technology

An EOG based Human Computer Interface System for Online Control. Carlos A. Vinhais, Fábio A. Santos, Joaquim F. Oliveira

Physiological Signal Processing Primer

Keywords: Data Acquisition, ECG, LabVIEW, Virtual instrumentation

Design of Low-Cost General Purpose Microcontroller Based Neuromuscular Stimulator

COMPEX MOTION - NEW PORTABLE TRANSCUTANEOUS STIMULATOR FOR NEUROPROSTHETIC APPLICATIONS

A Finite Impulse Response (FIR) Filtering Technique for Enhancement of Electroencephalographic (EEG) Signal

International Journal of Advancements in Research & Technology, Volume 2, Issue 12, December ISSN

Functional Electrical Stimulation (FES) via surface. RehaMovePro: A versatile mobile stimulation system for transcutaneous FES applications

BME 3113, Dept. of BME Lecture on Introduction to Biosignal Processing

Portable, Low Cost, Low Power Cardiac Interpreter

EKT 314/4 LABORATORIES SHEET

*Notebook is excluded

UNIT III Data Acquisition & Microcontroller System. Mr. Manoj Rajale

Biomedical Signal Processing and Applications

HUMAN BODY MONITORING SYSTEM USING WSN WITH GSM AND GPS

A SMART METHOD FOR AUTOMATIC TEMPERATURE CONTROL

Non Invasive Brain Computer Interface for Movement Control

common type of cardiac diseases and may indicate an increased risk of stroke or sudden cardiac death. ECG is the most

DESIGNING A VIRTUAL MACHINE FOR IDENTIFICATION OF CARDIAC ARRHYTHMIAS USING LAB VIEW

REAL-TIME WIRELESS ECG AND ITS SIGNAL DISPLAY ON LABVIEW

Measuring Voltage and Time Quantities of a Signal Through a Virtual Oscilloscope

SOCRATES. Auditory Evoked Potentials

Development of Electrocardiograph Monitoring System

A Virtual Instrument for Automobiles Fuel Consumption Investigation. Tsvetozar Georgiev

An implantable electrical stimulator for phrenic nerve stimulation

INDUCTION MOTOR FAULT DIAGNOSTICS USING FUZZY SYSTEM

International Journal of Electronics and Communication Engineering & Technology (IJECET), ISSN COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

Development of 4/16-Channel Data Acquisition System Using Lab VIEW

First steps towards an implantable electromyography (EMG) sensor powered and controlled by galvanic coupling

Chapter 4 4. Optoelectronic Acquisition System Design

Removal of Power-Line Interference from Biomedical Signal using Notch Filter

LV-Link 3.0 Software Interface for LabVIEW

IMPLEMENTATION OF CLASS-D AMPLIFIER IN HIGH PERFORMANCE SYSTEM FOR ELECTRO STIMULATION

Biomedical Engineering Evoked Responses

Lab 12 Laboratory 12 Data Acquisition Required Special Equipment: 12.1 Objectives 12.2 Introduction 12.3 A/D basics

BIOMEDICAL DIGITAL SIGNAL PROCESSING

Neural Function Measuring System MEE-1000A 16/32 ch. Intraoperative Monitoring System

IBES - Introduction to Biomedical Electronic Systems

* Notebook is excluded. Features KL-720 contains nine modules, including Electrocardiogram Measurement, E lectromyogram Measurement,

Physiological signal(bio-signals) Method, Application, Proposal

Biomedical Sensor Systems Laboratory. Institute for Neural Engineering Graz University of Technology

BME 701 Lecture 1. Measurement and Instrumentation

Motor Imagery based Brain Computer Interface (BCI) using Artificial Neural Network Classifiers

Project: Muscle Fighter

TAMIL NADU PUBLIC SERVICE COMMISSION. Post of Principal / Assistant Director (Training) Included in the Tamil Nadu Employment and Training Service

ni.com Sensor Measurement Fundamentals Series

IMPROVEMENTS IN ELECTROCARDIOGRAPHY SMOOTHENING AND AMPLIFICATION

A DESIGN OF PORTABLE HEART-RATE MONITORING SYSTEM

PC-based controller for Mechatronics System

Keywords Electromyographic (EMG) signals, Robotic arm, Root Mean Square (RMS) value, variance, LabVIEW

LabVIEW Based Biomedical Signal Acquisition and Processing

Wireless Neural Loggers

Syllabus Recording Devices

Research Article. ISSN (Print) *Corresponding author Jaydip Desai

CAMAC based Test Signal Generator using Reconfigurable

Biomedical Instrumentation B2. Dealing with noise

Design and Development of a Two Channel Telemedicine System for Rural Healthcare

A Single-Battery Switching Boost Converting Pulse Generator for Functional Electrical Stimulation in Rehabilitation Application

I. INTRODUCTION II. SYSTEM CONFIGURATION

Used to overcome ventricular fibrillation may be due to coronary occlusion, shock, or abnormalities in blood chemistry

Portable EEG Signal Acquisition System

PORTABLE ECG MONITORING APPLICATION USING LOW POWER MIXED SIGNAL SOC ANURADHA JAKKEPALLI 1, K. SUDHAKAR 2

A Lower Transition Width FIR Filter & its Noise Removal Performance on an ECG Signal

focused on implantable pulse generators for restoration of function in individuals paralyzed by stroke or SCI.

ECE 445 Fall 2017 Project Proposal. Recovery-Monitoring Knee Brace

Noise Reduction Technique for ECG Signals Using Adaptive Filters

PHY 351/651 LABORATORY 5 The Diode Basic Properties and Circuits

Ultra Low Power Multistandard G m -C Filter for Biomedical Applications

Design Issues of Portable, Low-Power & High-Performance ECG Measuring System Jyoti Bali, Anilkumar Nandi

Biomedical Instrumentation (BME420 ) Chapter 6: Biopotential Amplifiers John G. Webster 4 th Edition

Removal of Motion Noise from Surface-electromyography Signal Using Wavelet Adaptive Filter Wang Fei1, a, Qiao Xiao-yan2, b

EMG Signal Analysis and Application for Arm Exoskeleton Control.

Measurement & Control of energy systems. Teppo Myllys National Instruments

MEASURING AND ANALYZING FINE MOTOR SKILLS

Available online at ScienceDirect. Procedia Computer Science 105 (2017 )

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Analysis of The Effect of Linear and Non-Linear Loads against The Quality of Power at The Power Converter Anicetus Damar Aji 1 and Kusnadi 1

AN4995 Application note

On the Design of Software and Hardware for a WSN Transmitter

Patient Monitoring System Using LabVIEW

SPARK OF LIFE. How does your body react to electricity?

A Study on Gaze Estimation System using Cross-Channels Electrooculogram Signals

PROCESSING ECG SIGNAL WITH KAISER WINDOW- BASED FIR DIGITAL FILTERS

Laboratory Project 1: Design of a Myogram Circuit

Filtration Of Artifacts In ECG Signal Using Rectangular Window-Based Digital Filters

Transcription:

Jr. of Industrial Pollution Control 33(2)(2017) pp 1542-1546 www.icontrolpollution.com Research Article DESIGN OF BIO-POTENTIAL DATA ACQUISITION SYSTEM FOR THE PHYSICALLY CHALLENGED DHANASEKAR J 1*, SENGOTTUVEL P 1 AND HAMEED HUSSAIN J 2 1 Department of Mechatronics Bharath Institute of Higher Education and Research, Chennai, Tamilnadu, India 2 Bharath Institute of Higher Education and Research, Chennai, Tamil nadu, India (Received 07 August, 2017; accepted 20 September, 2017) Key words: Biopotential, Electromyogram, Stimulator, LabVIEW ABSTRACT The discovery of bio potentials in human body, influenced to invent numerous Bio Medical equipments. Many such equipments where modeled and implemented for treatment & curing various malfunctions of the organs. One such bio medical equipment is Functional Electric Muscle Stimulator (FES). This FES is mostly used for persons who are affected by stroke and spinal cord injury. Medical Personnel and Bio-medical Engineers around the world developed various Stimulators, where the stimulating currents are Faradic or surge or Galvanic types. Continuous Exposure of these types of current causes skin burns, increases static field etc. To overcome these disadvantages, the FES here produces a Biphasic Stimulating current which cures the defect at cell level itself. LabVIEW incorporated in FES to generate Biphasic electric current and stimulate the paralyzed muscles. The LabVIEW software is programmed for various operating frequencies ranging from 20 Hz to 100 Hz and also for various pulse width ranges 100 µs to 500 µs. A Pair of Carbonized EMG electrode is used to give transcutaneous electric current and stimulate the paralyzed Muscles. While another set of EMG Electrodes are used to pick up the EMG signals, at a time interval of 5 minutes after stimulation, which are in the frequency range of 20 Hz. The EMG signal produced from the Muscles is actually the potentional difference between the recording Electrodes. Many Manufacturers develop their own recording software. Here Bio Feedback signal (EMG) is recorded in PC using, a standard software, LabVIEW. The Picked-up EMG signals from the muscles are fed in to one of the channels the DAQ devices. The DAQ device, DAQmx 9233, removes the artifact from the Biofeedback signal and sends it to the PC for analyzing the EMG signals with the help of LabVIEW software, to find the cure percent of paralyzed muscles. INTRODUCTION Now-a-days, physicians diagnostics rely on electronic instrument for monitoring, logging and providing result. The Bio-instruments is focused on acquisition, processing and analysis of bio signals for medical purpose and real time monitoring of the patients (Holonce, et al., 2015; Arumugam, 1997). In biomedical engineering, the biomedical signals such as EMG, ECG, EEG are very important for real time monitoring (Raman, et al., 2010). The functional electrical stimulation (FES) is a form of orthotic/therapeutic treatment that applies transcutaneous current to initiate contractions in muscles, and is commonly used for the persons who are affected by spinal-cord injuries (SCIs) or stroke (Lau, et al., 2007; Holonce, et al., 2015). This FES is used to helps to lower and upper boundary mobility and to improve respiratory function. And also help to avoid inferior complications such as spasticity and pressure ulcers. This FES is a controlled electrical stimulus is applied to motor units/nerves to educe a muscle contraction in an endeavor to restore the functional movements of a paralyzed musculoskeletal system. Many of the FES stimulators have been developed with the help of either microcontroller or microprocessor. For this, it will improve upper and lower limb functions following stroke or SCI. FES are *Corresponding authors email: : jdhansekar81@gmail.com; dr.p.sengottuvel@gmail.com; dr.j.hussain@gmail.com

1543 DHANASEKAR ET AL. commonly work with pre-programmed stimulation patterns lookup table which are already stored. A single sensor united with a control algorithm either the reading scale stimulation parameters out of a lookup table or triggers pre-programmed stimulation sequences. (Cheng, et al., 2004; Bergveld, 1980; Katz, 1996) proposed various design of multiple-purpose portable functional electrical stimulator. LabVIEW expanded as Laboratory Virtual Instrumentation Engineering Work bench. LabVIEW is fundamental graphical development environment software which is used to signal acquiring and analysis to diagnosis (Selva and Gavaskar, 2015; Khandpur, 1987; Cromwell and Weibell, 1980; Web star, 1999). TRADITIONAL METHODS FES using a transformer circuit Traditionally, an analogue electronics has been used for designing of FES circuit using oscillator for generating pulses. The output waveforms which are include of frequency, amplitude and pulse width are to be regulated. To produce the required output voltage a step-up transformer has been used to step up. Fig. 1 shows the circuit of the muscular stimulator. PROPOSED METHOD OF FES USING LABVIEW In this paper uses PC with LabVIEW software to control the amount of stimulating pulses to the muscles. The entire circuitry is energized by alkaline battery (12 V). The signals from the PC is converted to Analog by DAC, amplified, and converted to current output by V/I converter. This output current is fed to the muscles by surface electrodes. Another pair of surface electrodes senses the EMG signal produced by the muscles in response to external electric stimulation. This EMG signal consists of various noises due to motion of muscles. So these raw EMG signals are conditioned and send to the PC for analysis using LABVIEW Software. The block diagram is shown in Fig. 2. After that we select the ordered coefficient from 1 to N to get N coefficient. the formulae of watermark embedding are as follows. The main objective of this paper is to design and implement a low cost LabVIEW based Functional Electric Muscle Stimulator for rehabilitation of patients suffering from paralysis and finding the cure percent of the paralytic patient. For the stimulation of skeletal muscles Electric pulses are needed for different frequency ranges depending on the complexity of the patients (extension, contraction, and orienting to some degrees). Flexible designs and programming for this complexity is possible by LabVIEW software. LabVIEW The (Babu, et al., 2016; Jacobson and John, 1979) proposed real time patient monitoring system using LabVIEW which is used to continuous monitoring of a patient and helps the doctors to make diagnosis. Fig.1 Typical FES circuit.

DESIGN OF BIO-POTENTIAL DATA ACQUISITION SYSTEM FOR THE PHYSICALLY CHALLENGED 1544 In this paper, the main purpose of LabVIEW programming is virtual automating of the usage of measuring equipment and any processing of system. In this paper uses USB 9162 card in the output side where one can get the signals from EMG electrode. The signal is analysed through LabVIEW and the generated signal is given to DAQ card USB 6009. The current output from V-I converter is send to surface electrodes to stimulate the muscles. (Fig. 3) shows LabView panel and (Fig. 4) shows LabVIEW generated pulses (Fig. 3 and 4). I/O Card The NI USB-9162 is a 4-channel dynamic sign securing module for making high-exactness estimations from IEPE sensors. It can be delivers 102 db of element range and incorporates IEPE signal molding for accelerometers and amplifiers. The 4 USB-9233 information channels all the while gain at rates from 2 khz to 50 khz. (Fig. 5) shows a NI IO card with its 4 simple info channels. DAQ Card Fig. 6 shows NI USB-6009 which supplies connection to 8 analog input (8-AI) channels, two analog output (2-AO) channels, 12 digital input/output (12-DIO) channels, and a 32-bit counter with a Full-Speed Universal Serial Bus (USB) interface. Fig.2 Block diagram. Fig.3 Lab VIEW panel.

1545 DHANASEKAR ET AL. Fig.4 Lab VIEW generated pulses. EMG SIGNAL RECORDING UNIT This recording unit comprises of surface electrodes to acquire raw signals from the stimulated region, instrumentation amplifier, signal conditioning unit which is the combination of low pass filters and integrators, DAQ, and a PC with LABVIEW software7.1.the integrator unit is to combine the signals from various electrodes. The low pass filter removes the noises such as motion artifacts and fluctuations in the input, usually notch filters are used. The DAQ card stores the data before send to PC. The signal Obtained is recorded and analyzed for further variations to be given in the input. Important parameters required for quantitative analysis are peak rate, zero crossing rate, negative wave duration, wave rise time like that of time domain parameters. Fig. 7 shows the signal recording unit. Recording Electrode The bioelectric events before they can be put into the amplifier for subsequent record or display have to be picked up from the surface of the body. This is done by using of electrodes. Electrodes make transfer from ionic conduction in the tissue to the electronic conduction which is used for measurements. Two types of electrodes are in practice, one is surface electrodes- pickup potential difference from tissue surface and other one is needle electrode-potential difference arising inside the live tissue. Fig. 8 shows surface electrode. RESULTS AND DISCUSSION The stimulator gives out constant current output of Fig.5 NI USB 9162 I/O card. Fig.7 Signal recording unit. Fig.6 NI USB-6009 DAQ. Fig.8 Surface electrodes.

DESIGN OF BIO-POTENTIAL DATA ACQUISITION SYSTEM FOR THE PHYSICALLY CHALLENGED 1546 amplitude 200mA.From previous discussions it is decided to use bi-phasic pulse for stimulation. In this paper, various frequencies and pulse width ranges are used for biphasic pulse output. The frequency is varied from 20 Hz, 40 Hz, 80 Hz, 100 Hz, whereas the pulse width ranges from 100 µs, 200 µs, 300 µs, 400 µs. CONCLUSION In this paper various frequency and pulse width ranges are selected using Rotary switches. FES also incorporates a toggle switch, which on one side gives biphasic pulse output while on other side it displays the selected frequency and pulse width ranges. REFERENCES Arumugam, M. (1997). Biomedical instrumentation. Anuradha Agencies, Andhra Pradesh, India. Bergveld, P. (1980). Electro medical instrumentation A guide for medical personnel. Cambridge University Press, UK. Babu, M., Roshna, R.R., Sunil, S., Teenu, M.M. Abubeker, K.M. (2016). Real time patient monitoring system using LabVIEW. IJARCCE. 5 : 505-507. Cheng, K.W.E., Yan, L. and Kai-Yu, T. (2004). Development of a circuit for functional electrical stimulation. IEEE Transactions on Neural Systems and Rehabilitation Engineering. 12. Cromwell, L. and Weibell, F.J. (1980). Biomedical Instrumentation and Measurements. Prentice Hall. New Jersey. Holonce, R., Marius, G., Romul., Copindean. and Florin, D. (2015). An Electo-oculogram Based Virtual Insrumentation System. p. 56. Jacobson, B. and John, G.W. (1979). Medical and Clinical Engineering. Prentice Hall. New Delhi, India. Katz, B. (1996). Nerve, Muscle and Synapse. MC Graw Hill Company. New York, USA. Khandpur, R.S. (1987). Handbook of Biomedical Instrumentation. Tata McGraw-Hill. New Delhi, India. Lau, B., Guevremont, L. and Mushahwar, V.K. (2007). Strategies for generating prolonged functional standing using intramuscular stimulation or intra spinal micro stimulation. IEEE Transactions on Neural Systems and Rehabilitation Engineering. 15(2) : 273-285. Raman, Y., Sharda, V. and Ashok, K.S. (2010). Real time acquisition and analysis ECG signal using MAT LAB. International Journal of Advance in Engineering Science and Technology. 2 : 6-10. Selva, R.R. and Gavaskar, S. (2015). Implementation of portable device for real time bio signal analysis using LabVIEW. CiiT-Wireless Communication. 7. Webstar, J.G. (1999). Medical Instrumentation: Application and Design. 3rd Edition. John Willey and sons, NY, USA. p. 587.