A positioning QA procedure for 2D/2D (kv/mv) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup

Similar documents
CHAPTER 2 COMMISSIONING OF KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIOTHERAPY

Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience

CHAPTER 6 QUALITY ASSURANCE OF VARIAN ON-BOARD IMAGER

QUALITY CONTROL PHANTOMS FOR RADIOTHERAPY AND MEDICAL IMAGING

PHYSICS QUESTIONNAIRE FORM

QC Testing for Computed Tomography (CT) Scanner

COMPREHENSIVE TG-142 IMAGING AND MACHINE QA

Sub-mm accuracy of accelerators: How manufacturers achieve it, how physicists verify it

7/23/2014. Acknowledgements. Implementing a new digital medical accelerator. New Generation of Medical Accelerators

ISO Cube Daily QA Package

The Current State of EPID-Based Linear Accelerator Quality Assurance. Disclosures. Purpose of this First Talk 8/3/2017

Nathan Childress, Ph.D., DABR

DOSELAB TOMOTHERAPY TG-148 QA QUICK GUIDE TG-148 RECOMMENDED TESTS 1. V.B.1.C. - Y-JAW DIVERGENCE/BEAM CENTERING

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications

Performance evaluation of the RITG148 + set of TomoTherapy quality assurance tools using RTQA 2 radiochromic film

Initial setup and subsequent temporal position monitoring using implanted RF transponders

8/3/2016. The EPID Strikes Back. Novel Applications for Current EPID Technology. Joerg Rottmann, PhD. Disclosures and acknowledgements

8/3/2017. Use of EPIDs for Non-Routine Linac QA. Disclosure. Learning Objectives. Parts of this project received support from Varian Medical System.

An Introduction to TG-142 Imaging QA Using Standard Imaging Products. Mark Wiesmeyer, PhD, DABR Technical Product Manager Standard Imaging, Inc.

Isocenter and Field of View Accuracy Measurement Software for Linear Accelerator

Gantry angle determination during arc IMRT: evaluation of a simple EPID-based technique and two commercial inclinometers

Phantoms in Medical Physics (RT) U. Oelfke. Division of Radiotherapy & Imaging

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA

Sensitivity study of an automated system for daily patient QA using EPID exit dose images

Comparative performance evaluation of a new a-si EPID that exceeds quad high-definition resolution

Evaluation of dosimetry parameters of photons and electron beams using a linear ionization chamber array

A Generalized Strategy for 3D Dose Verification of IMRT/VMAT Using EPID-measured Transit Images

Table 1: Available X-ray Beam Energy Combinations (MV) 6 10/ Yes Yes 6 16/15 6 Yes No 6 23/18 6 Yes No 6 25/20 6 Yes No

X3D in Radiation Therapy Procedure Planning. Felix G. Hamza-Lup, Ph.D. Computer Science Armstrong Atlantic State University Savannah, Georgia USA

TOPICS: CT Protocol Optimization over the Range of Patient Age & Size and for Different CT Scanner Types: Recommendations & Misconceptions

A new approach to measure dwell position inaccuracy in HDR ring applicators quantification and corrective QA

Automated dose control in multi-slice CT. Nicholas Keat Formerly ImPACT, St George's Hospital, London

SUN NUCLEAR. EPIDose : An Overview of EPIDose and the EPIDose Process and Algorithm. corporation. Your Most Valuable QA and Dosimetry Tools

Web based 3D Planning Tool for Radiation Therapy Treatment

3D Diode Array Commissioning: Building Confidence in 3D QA Technology

LINEAR ACCELERATOR. Buyer's Guide. Version 1.1

Development of a Virtual Simulation Environment for Radiation Treatment Planning

Distributed source x-ray tube technology for tomosynthesis imaging

A diagnostic tool for basic daily quality assurance of a tomotherapy Hi Art machine

A proposed method for linear accelerator photon beam steering using EPID

Enhanced Functionality of High-Speed Image Processing Engine SUREengine PRO. Sharpness (spatial resolution) Graininess (noise intensity)

Quality Assurance Results for a Commercial Radiosurgery System: A Communication

Stability of the Helical TomoTherapy Hi Art II detector for treatment beam irradiations

T h e P h a n t o m L a b o r a t o r y

Effect of slit scan imaging techniques on image quality on radiotherapy electronic portal imaging

specifications TrueBeam STx System

7/24/2014. Image Quality for the Radiation Oncology Physicist: Review of the Fundamentals and Implementation. Disclosures. Outline

specifications TrueBeam System

Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy

2D, 3D CT Intervention, and CT Fluoroscopy

A device for precision positioning and alignment of room lasers to diminish their contribution to patient setup errors

Evaluation of a diode array for QA measurements on a helical tomotherapy unit

Commissioning. Basic machine performance MLC Dose rate control Gantry speed control End-to-end tests

Emerging Technology: Real-Time Monitoring of Treatment Delivery EPID Exit Dose QA

IMRT Delivery System QA. IMRT Dose Delivery. Acceptance testing. Why: specific tests for IMRT? Accuracy of leaf positioning (gaps) MLC Alignment

A neural network-based 2D/3D image registration quality evaluator for pediatric patient setup in external beam radiotherapy

The evaluation of minimum detectable phantom thickness change using a scanning liquid filled ion chamber EPID dose response

ISPFILMQATM STATE-OF-THE-ART RADIOTHERAPY VERIFICATION SOFTWARE. Supports all major radiotherapy technologies! FilmQA TM

A SIMPLE METHOD TO BACK-PROJECT ISOCENTER DOSE OF RADIOTHERAPY TREATMENTS USING EPID TRANSIT DOSIMETRY

specifications The Complete Radiation Oncology Solution

QUALITY CONTROL SOFTWARE FOR RADIOTHERAPY AND MEDICAL IMAGING

Pitfalls and Remedies of MDCT Scanners as Quantitative Instruments

Accuracy of SRS dose delivery using the TomoTherapy Hi-Art System

specifications Novalis Tx image-guided radiosurgery linear accelerator

Chapter 3. Material and Methods

A Beam-Level Delivery Accuracy Study of the Robotic Image Guided Radiosurgery System Using a Scintillator/CCD Phantom

Q3D. Speak to a 3D Specialist. CBCT 3D / Panoramic Imaging GENERAL DIMENSIONS. Suni Imaging Product Lines GET.

Aim. Images for this section: Page 2 of 13

Image Quality and Dose. Image Quality and Dose. Image Quality and Dose Issues in MSCT. Scanner parameters affecting IQ and Dose

X-RAD SmART (Small Animal RadioTherapy) IMAGE GUIDED BIOLOGICAL IRRADIATOR Technical Specifications (updated March 2015)

Introduction. Use of EPIDs for Routine Linac QA 8/3/2017. Disclosure. Our research group receives funding from Varian Medical Systems

P a n o r a m i c a n d C e p h a l o m e t r i c X - r a y s

CyberKnife Iris Beam QA using Fluence Divergence

Maximizing clinical outcomes

Commissioning and Calibrating a Linear Accelerator State-of-the-Art in 2010

Aperture Based Inverse Planning AAPM Summer School 2003

DIAGNOSTIC ACCREDITATION PROGRAM. Radiology and CT Quality Control Procedures Workbook

Acceptance Testing of a Digital Breast Tomosynthesis Unit

Image Quality and Dose of an Accelerator-Integrated kv CBCT Systems

Invisible sophistication. Visible simplicity. CS Welcome to the simplicity of compact panoramic imaging

CT Scanner Dose Survey

TOMOTHERAPY H SERIES TomoH, TomoHD and TomoHDA Systems Technical Specifications

COMPUTED TOMOGRAPHY 1

Monte Carlo study on a new concept of a scanning photon beam system for IMRT

Department of Physics, State University of New York at Buffalo, Buffalo NY, USA

The physical characteristics of a SLIC-EPID for transmitted dosimetry

UNIQUE. The Complete Radiation Oncology Solution SPECIFICATIONS

P a n o r a m i c a n d C e p h a l o m e t r i c X - r a y s

IQM Detector Characteristics: Signal reproducibility

QA Considerations. QA for LGK Perfexion : : Follow NRC licensing guidelines (10( CFR ) Leksell Gamma Knife Perfexion

Y11-DR Digital Radiography (DR) Image Quality

Nuclear Associates

The Ultimate 4D QA Solution A 4D isotropic cylindrical detector array for arc delivery QA and Dosimetry.

Laser Systems for Patient Alignment

1. Patient size AEC. Large Patient High ma. Small Patient Low ma

Digital Imaging started in the 1972 with Digital subtraction angiography Clinical digital imaging was employed from the 1980 ~ 37 years ago Amount of

Mobius3D. Software based IMRT QA

A Fast Monolithic System for Proton Imaging. Fritz DeJongh ProtonVDA Inc October 2017

C a t p h a n. T h e P h a n t o m L a b o r a t o r y. Ordering Information

Measurement of table feed speed in modern CT

Transcription:

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 10, NUMBER 4, FALL 2009 A positioning QA procedure for 2D/2D (kv/mv) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup Huaiqun Guan, 1a Rabih Hammoud, 2 Fang-Fang Yin 3 Department of Radiation Oncology, 1 Good Samaritan Health System, Kearney, NE, USA; Henry Ford Down River Center for Oncology 2, Trenton, MI, USA; Department of Radiation Oncology, 3 Duke University Medical Center, Durham, NC, USA. huaiqunguan@catholichealth.net Received 1 October 2008; accepted 29 June 2009 A positioning QA procedure for Varian s 2D/2D (kv/mv) and 3D/3D (planct/ CBCT) matching was developed. The procedure was to check: (1) the coincidence of on-board imager (OBI), portal imager (PI), and cone beam CT (CBCT) s isocenters (digital graticules) to a linac s isocenter (to a pre-specified accuracy); (2) that the positioning difference detected by 2D/2D (kv/mv) and 3D/3D(planCT/ CBCT) matching can be reliably transferred to couch motion. A cube phantom with a 2 mm metal ball (bb) at the center was used. The bb was used to define the isocenter. Two additional bbs were placed on two phantom surfaces in order to define a spatial location of 1.5 cm anterior, 1.5 cm inferior, and 1.5 cm right from the isocenter. An axial scan of the phantom was acquired from a multislice CT simulator. The phantom was set at the linac s isocenter (lasers); either AP MV/R Lat kv images or CBCT images were taken for 2D/2D or 3D/3D matching, respectively. For 2D/2D, the accuracy of each device s isocenter was obtained by checking the distance between the central bb and the digital graticule. Then the central bb in orthogonal DRRs was manually moved to overlay to the off-axis bbs in kv/mv images. For 3D/3D, CBCT was first matched to planct to check the isocenter difference between the two CTs. Manual shifts were then made by moving CBCT such that the point defined by the two off-axis bbs overlay to the central bb in planct. (PlanCT can not be moved in the current version of OBI1.4.) The manual shifts were then applied to remotely move the couch. The room laser was used to check the accuracy of the couch movement. For Trilogy (or Ix-21) linacs, the coincidence of imager and linac s isocenter was better than 1 mm (or 1.5 mm). The couch shift accuracy was better than 2 mm. PACS number: 87.55.Qr, 87.57.Q- Key words: OBI, CBCT, positioning QA, 2D/2D (kv/mv), 3D/3D (planct/ CBCT) I. Introduction On-board imagers (OBI) using kilovoltage X-rays (kv) have been installed on linear accelerators (linacs) from multiple vendors. Patient setup and target localization can be improved with the use of OBI, which is critical for intensity-modulated radiotherapy (IMRT) and radiosurgery (IMRS). The OBI not only allows 2D patient setup, it also acquires cone beam CT (CBCT) for 3D patient setup. The detected differences between the online image (either 2D-kV image or 3D-CBCT image) and the patient reference images (either 2D-DRR images or 3D-planning CT images) can be automatically transferred to couch motion from the treatment console. However, a Corresponding author: Huaiqun Guan, Department of Radiation Oncology, Good Samaritan Health System, Kearney, NE 68848 USA; phone: 308-865-7566; fax: 308-865-2907; email: huaiqunguan@catholichealth.net 273 273

274 Guan et al.: Positioning QA for radiotherapy image matching 274 quality assurance is critical for precise image-guided radiotherapy (IGRT). (1-5) For 2D/2D matching, kv/mv allows aggregated acquisition of dual images without rotating the linac gantry. For precision radiation therapy (like IMRS) to sites where bones can be good landmarks, kv/mv images can be adequate for quicker patient setup than kv/kv. In our previously reported OBI QA program, (6) kv/kv was recommended for OBI only, using a cube phantom with two sets of small metal balls or bbs, on either a daily or weekly basis. Here we simplify the procedure by just using one set of bbs for kv/mv matching. Further, planct/cbct allows direct 3D/3D tissue-to-tissue matching for patient setup. But positioning QA for 3D/3D matching was not reported yet. In this paper, we present a combined QA procedure to check: (1) the coincidence of OBI, PI, and CBCT s isocenters (digital graticules) to linac s isocenter (to a prespecified accuracy); (2) that the positioning difference detected by 2D/2D and 3D/3D matching can be reliably transferred to couch motion. II. Materials and Methods In our institutions, the OBI and portal imaging (PI) were installed on Varian linacs, either Trilogy or Ix-21 (Varian Medical Systems, Palo Alto, CA). The Cubic Isocenter Phantom (Fig. 1(a)) provided by Varian was used. The phantom has a 2 mm metal ball (bb) embedded at the center to define the isocenter. We placed two off-axis bbs on two phantom surfaces in order to define a spatial point 1.5 cm anterior, 1.5 cm inferior, and 1.5 cm right from the isocenter. The off-axis bb on the anterior surface was placed 1.5 cm right and 1.5 cm inferior from the center, and the off-axis bb on the right surface was placed 1.5 cm anterior and 1.5 cm inferior from the center. The two bbs shown in the previous study (6) to define isocenter were removed because of the built-in bb at phantom center. In Fig. 1(a), the gantry direction was labeled as G. An axial scan of the phantom was acquired using a multislice CT simulator with 0.625 mm slice thickness. A plan with three setup fields (AP-MV, Lat-kV, and CBCT) was created in Eclipse with digitally reconstructed radiographs (DRR) attached. The difference between the source-to-surface distance (SSD, 97.5 cm) to off-axis bbs and the source-to-axis distance (SAD, 100 cm) to the isocenter makes the magnification factor 2.5% larger in kv/mv images than the corresponding DRRs. This may cause 0.25 mm systematic error for couch shift accuracy (based on off-axis bbs) but not for the isocenter accuracy (based on central-axis bbs). We generated DRRs with a magnification factor of 1.025 in order to eliminate the error. The 2D/2D QA procedure is as follows: 1) Set up the cube phantom at the linac s isocenter by aligning the anterior crosshair to linac s light-field crosshair and the lateral crosshairs to lateral lasers 2) Take AP MV and Lat kv images 3) Determine the accuracy of OBI and PI s isocenter by measuring the distance between the central bb and the digital graticule 4) If the accuracy is within specification, manually move the central bbs in DRR images to overlay to the off-axis bbs in the kv/mv images (If it is not, a service from the vendor is needed.) 5) Document the detected expected shifts and then apply to remotely move the couch 6) After moving, visually check the alignment of room lasers to off-axis bbs. If not aligned, set the lasers to bbs and record the final couch position. The actual couch shifts are the differences between the initial and the final couch position. The accuracy is the difference between the expected shifts and the actual shifts. Accuracy should be within 2 mm because it is the combination of couch motion accuracy approximately equal to 1.4 mm (1 mm accuracy each before and after the motion) and laser alignment accuracy approximately equal to 1.4 mm (also 1 mm each before and after the motion)

275 Guan et al.: Positioning QA for radiotherapy image matching 275 Fig. 1: (a) the cube phantom with 2 bbs placed on the surface; (b) the AP MV image; (c) the R Lat kv image. The 3D/3D QA procedure is: 1) Set up the cube phantom at the linac s isocenter 2) Take CBCT image in full fan High Quality Head mode using OBI 3) Match planct to CBCT to check the isocenter difference between the two sets of CTs 4) If that difference is within the specification, manually move the CBCT such that the spatial point defined by the two off-axis bbs overlay to the central bb in planct (but not the other way, in the current version of OBI1.4) The rest of the procedure is the same as above for 2D/2D QA. III. Results Figure 1(b) shows the AP MV image and Fig. 1(c) shows the R-Lat kv image. The two off-axis bbs on the surface of the cubic phantom were also indicated to their corresponding locations in kv image (Fig. 1(c)). By measuring the distance between the center of central bb (linac isocenter) and the center of digital graticules (imager isocenter) on either the MV or kv image, the accuracy of the OBI or PI s isocenter was obtained, as demonstrated in Fig. 2. The daily document of isocenter accuracy was also shown in Fig. 2 for AP MV (left) and LAT kv (right). Figure 3 represents the six-week documentation of the isocenter accuracy for a Varian Ix-21 machine in (a) AP MV (mean and standard deviations: S/I: 0.31 ± 0.15 mm and R/L: 0.49 ± 0.40 mm), and (b) LAT kv (mean and standard deviations: S/I 0.31 ± 0.13 mm and A/P:0.83 ± 0.27 mm). One sees that the accuracy was better than 1.5 mm. For Troligy, the isocenter accuracy was better than 1 mm.

276 Guan et al.: Positioning QA for radiotherapy image matching 276 Fig. 2. Document of the daily isocenter accuracy in AP (left) and R-LAT (right) for a Trilogy machine. (a) (b) Fig. 3. Plots of the isocenter accuracy on (a) AP MV field and (b) R LAT kv field for a Varian Ix-21 machine over 6 weeks. The means and standard deviations for (a) S/I: 0.31 ± 0.15 mm and R/L: 0.49 ± 0.40 mm; (b) S/I 0.31 ± 0.13 mm and A/P: 0.83 ± 0.27 mm.

277 Guan et al.: Positioning QA for radiotherapy image matching 277 If the QA for kv/mv isocenter passes, the central bb in DRR images was manually moved to overlay to off-axis bbs in kv/mv images (In OBI, 2D/2D manual matching can only be made by moving the DRR image). The matching detected the shifts in three-dimension, which then applied to remotely move the couch. Figure 4(a) shows the matching of central bb to the off-axis bbs for MV (left) and kv (right). Figure 4(b) documents the detected (expected) 3D shifts and initial couch position. After the couch movement, the light-field corsshair (for anterior) and laser (for lateral) alignment to off-axis bbs were visually checked. If not aligned, the lasers were set to off-axis bbs and final couch position was recorded. The actual shifts were the difference between the initial and final couch positions. The accuracy of couch shifts (i.e. the expected - actual ) should be within 2 mm. The final couch position, the actual couch shifts, and the shifting accuracy were also documented in Fig. 4(b). Figures 5(a) 5(d) show the sequence of shifting planct s isocenter to the off-center point defined by the two off-axis bbs in CBCT. They were captured from the 3D/3D matching window. In each of these figures, the top left is the axial view, the bottom left is the coronal view, and the bottom right is the sagital view. (The top right is the planct view only and thus not shown here.) Figure 5(a) shows the 3D/3D matching of planct to CBCT. After the matching, the couch vertical (Vrt), longitudinal (Lng) and lateral (Lat) shifts were 0.0, 0.1, and - 0.1 cm, respectively. In Fig. 5(b) we used the image scroll function in axial view until the two off-axis bbs were displayed. We then dragged the green dash line up to the bb on the right side. On the coronal view, the blue dash line is right on the bb. In Fig. 5(c) we first dragged the blue dash line in coronal/sagital view to planct s isocenter (the tiny green circles). We then dragged the CBCT image up until the side bb is on the blue dash line. The couch Vrt, Lng and Lat shifts were 0.0, 1.6 and - 0.1cm, respectively. Note that 3D/3D manual matching can only be made by moving the CBCT image. In Figure 5(d), with the red dash line set so that it passes through planct s isocenter, in the axial view we dragged the CBCT image to bottom right until the planct s isocenter aligned with the two off-axis bbs on CBCT. The matching generated expected couch shifts of 1.5, 1.6 and 1.5 cm. Then after the couch movement, the data table shown in Fig. 4(b) was also used to document the expected shifts, the initial and final couch positions, and the actual shifts. Again the accuracy of couch shifts (i.e. the expected actual ) should be within 2 mm.

278 Guan et al.: Positioning QA for radiotherapy image matching 278 (a) (b) Fig. 4: (a) overlay of the central axis bb on DRR to the off-axis bb on MV (left) and kv(right) images (the shifts will be displayed on the dashboard of OBI); (b) document of couch positions, couch shifts, and tolerances.

279 Guan et al.: Positioning QA for radiotherapy image matching 279 (a) (b) (c) (d) Fig. 5 The sequence (a-d) of moving planct s isocenter to the off-axis point, defined by the two off-axis bbs in CBCT. In each, the top left is the axial view, the bottom left is the coronal view and the bottom right is the sagittal view. (a) 3D/3D matching of planct to CBCT; (b) image scroll in axial view until the 2 off-axis bbs displayed, then drag the green dash line up to where the side bb is (on the coronal view, the blue dash line is right on the side bb); (c) drag the blue dash line in coronal/sagittal view to planct s isocenter (tiny green circles), then drag CBCT image up until the side bb is on the blue dash-line; (d) with the red dash line set also passing through planct s isocenter, in the axial view drag the CBCT image to bottom right until planct s isocenter aligns with the two off-axis bbs in CBCT. IV. DISCUSSION Figure 3(b) shows that for Lat kv in a Varian s Ix-21 machine, the imager isocenter was much more accurate in the S/I direction than in the A/P direction. Gravity-caused imager sagging may be the major reason. For AP MV, the mean accuracy in S/I was also better than that in R/L. The mean accuracy in S/I was similar for both AP MV and Lat kv. In general, the image isocenter s accuracy is a combination of the accuracy of retractable arm s calibration, and the stability of the arm and gantry during the rotation. For the couch shift tolerance of 2 mm, we considered: 1) that the couch reading accuracy is approximately 1.4 mm (considering each

280 Guan et al.: Positioning QA for radiotherapy image matching 280 1 mm reading accuracy before and after the motion); and 2) the light field crosshair and laser alignment accuracy, which is also approximately 1.4 mm before and after the motion. Overall, 2 mm was set as the limit. We noticed that the central bb in MV imaging is less easily visible. It becomes easier to identify the center of the central bb when: 1) it is set not to overlap with the couch s tennis grid, 2) the operator zooms the MV image by a large factor; and 3) the operator sets the display window level (-1350, - 200). We also note that for OBI, 2D/2D is matched by moving the DRRs (i.e. reference) but not kv/mv images. On the other hand, 3D/3D is matched by moving the CBCT but not the reference (i.e. planct). We suggest that Varian make this consistent in a future release of OBI. This QA procedure is based on the phantom measurement. For real patients, it should be noted that the matching is not based on the high contrast bbs but rather on the anatomical structures using either the manual matching or specific algorithms (e.g. the mutual information). The accuracy of the matching also depends on the imaging techniques (kv, mas), the matching area covered (local ROI or global), the treatment site, and even the patient size. Thus, additional errors may be involved in matching. V. Conclusions In this paper, a positioning QA procedure for Varian s OBI, PI and CBCT system was developed. The suggested QA tests assure that the imaging isocenter is reliable and the couch movement is also reliable for the verification of patient positioning, using either 2D/2D or 3D/3D matching. The procedure is robust and easy to implement. We recommended that the QA for 2D/2D may be made on a daily or weekly basis, and that for 3D/3D, it may be made on a monthly basis. Acknowledgements We appreciate the comments from the anonymous reviewers which helped make this manuscript ready for publication. References 1. Bissonnette JP. Quality assurance of image-guidance technologies. Semin Radiat Oncol. 2007;17(4):278 86. 2. Bissonnette JP, Moseley DJ, Jaffray DA. A quality assurance program for image quality of cone-beam CT guidance in radiation therapy. Med Phys. 2008;35(5):1807 15. 3. Bissonnette JP, Moseley DJ, White E, Sharpe M, Purdie T, Jaffray DA. Quality assurance for the geometric accuracy of cone-beam CT guidance in radiation therapy. Int J Rad Oncol Biol Phys. 2008;71(1 Suppl):S57 S61. 4. Doemer A, Gingold E, Misic V, Podder T, Yu Y, Xiao Y. Consolidated image quality QA for diagnostic CT and radiotherapy cone beam CT [abstract]. Med Phys. 2008;35(6):2781. 5. Schreibmann E, Elder E, Fox T. Automated quality insurance for image-guided radiation therapy. J App Clic Med Phys. 2009;10(1):71 79. 6. Yoo S, Kim GY, Hammoud R, et al. A quality assurance program for the on-board imagers. Med Phys. 2006;33(11):4431 47.