PANELMDP Main Distribution Panel. Descriptions Energy Efficient Transformer

Similar documents
2.1. Product Description

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

2.5. Contents Description Motor Drive Isolation Transformers... Mini Power Centers... Totally Enclosed Non-Ventilated Transformers

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

2.5. Transformers. Mini Power Centers. Distribution Transformers. Product Description

P48G11S05P 5KVA 1PH 480V - 120/240V Mini Power Center

Technical Data and Specifications. Core and Coil Assemblies

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

LVGP. Advanced transformers built for the industrial environment. Catalog: LVGP-16C-English. By Micron Power Delivery. Supersedes: LVGP-16B-English

T S 15KVA 1PH 240/480 Transformer

Warehouse Stock Transformers

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

General Purpose Transformers

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

Premium 30 Energy Efficient, Low Voltage Transformers General Purpose, Harmonic Mitigating, and K-Rated

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Jefferson Electric Inc Product Catalog JE901

Energy Efficient Distribution Transformers

Low Voltage Transformers. Selection Guide

Standards. n Built in accordance with NEMA, ANSI, UL and CSA standards

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

BUCK-BOOST TRANSFORMERS

Steps for Selecting the Proper Transformer

HPS Universal BUCK-BOOST TRANSFORMERS

Your Presenters. > Thomas Patzner Product Manager, Low Voltage Transformers. > Marquette University Electrical Engineering. > Apprentice Electrician

Dry-Type Transformers

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

What is a Transformer?

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

225 kva Autotransformer - 240V Delta Primary Voltage - 220V Delta Secondary Voltage - NEMA 3R

Description. Features and Benefits

Liquid-Filled Transformers

Transformer Questions & Answers

10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

Full Line Product Catalog

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R

SECTION TRANSFORMERS

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

ULTRA-K Series 600K - he

Transformer Questions & Answers

15 kva Isolation Transformer - Single Phase - 208V Primary - 120/240V Secondary - NEMA 3R

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

Straight Isolation - Hard Wired (169 Series)

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

DONGAN ELECTRIC MANUFACTURING CO.

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

Dry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION

Full Line Product Catalog

Power Processor - Series 700F 10KVA to 150KVA

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

Acme Electric Full Line Product Catalog

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs

Howard Smart Transformer Specification Guide

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase

Isolation Transformer Series

Product Data Bulletin

Drive Isolation Transformers

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

K Factor Power Transformers

Power-Sure 700. Technical Data TD158001EN. Contents

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

FSK1VDRA 1G Al DPLX RCPT CVR

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

Load Isolation Transformers

General Description & Features Selection Charts Definition of Terms... 42

T-Line, current transformers

Non-Submersible Industrial Pressure Transducer

DTS ISOLATION TRANSFORMER SPECIFICATIONS

MGM Transformer Company

Non-Linear Load Transformers

BX /2 Solid Ac/BX Aluminum Cable

PowerGard Series C 18-Pulse Enclosed Drive Controllers

Buck-Boost Transformers

Harmonic mitigating transformers. Energy savings through harmonic mitigation

EVLP Low Profile Hazard Gard (H.I.D.) Luminaires

TRANSFORMERS & INDUCTORS MYRRA....Of course!

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

L.T.F Dimmable Low Voltage UniDriver- CLASS 2

Transcription:

PANELMDP Main Distribution Panel Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Product Type PANELMDP Eaton Corp 1.0 (lbs/each) Three Phase Energy Efficient D Energy Efficient Transformer Manufacturer Information Brand EATON CUTLER-HAMMER GTIN 00786680046964 Manufacturers Part Number V9MT1EE UPC 786680046964 Availability Manufacturer Status Packaging Carton 1 Weight Per each 1 Non-Stock

.1 Transformers Type DT-3 Contents Description Features, Benefits and Functions........... Standards and Certifications.............. Catalog Number Selection................ Product Selection....................... Single-Phase Aluminum................ Single-Phase Copper................... Single-Phase Shielded Aluminum......... Single-Phase Shielded Copper........... Three-Phase Aluminum................. Three-Phase Copper................... Three-Phase Shielded Aluminum......... Three-Phase Shielded Copper............ Accessories........................... Technical Data and Specifications.......... K-Factor.............................. Aluminum........................... Copper.............................. Page V-T-3 V-T-3 V-T-4 V-T-4 V-T-4 V-T-6 V-T-8 V-T-10 V-T-1 V-T-3 V-T-34 V-T-4 V-T-50 V-T-50 V-T-51 V-T-5 V-T-57 Product Description Note: The following pages provide listings for most standard transformer ratings and styles. For other ratings or styles not shown, or for special enclosure types (including stainless steel), refer to Eaton. Types DS-3, DT-3 Ventilated, NEMA enclosure standard Suitable for indoor applications, outdoors when weathershields are also installed Upright mounting only 0ºC 150ºC rise standard; 115 C or 80 C rise optional Available in single-phase ratings 15 167, 600 volts primary (DS-3) Available in three-phase ratings 15 1500 and up to 600 volts primary (DT-3) Application Description NEMA TP-1-00 compliant energy-efficient transformers are specifically designed to meet the energy efficiency standards set forth in NEMA Standards publication, TP-1-00, Guide for Determining Energy Efficiency for Distribution Surveys have shown that the average loading of low voltage dry-type distribution transformers, over a 4-hour period, is approximately 35%. NEMA TP-1 compliant transformers are optimized to offer maximum efficiency at 35% of nameplate rating. The range of products covered by NEMA TP-1-00 are: NEMA TP-1-00 Product Range Voltage Rating Class Dry-Type Rating Liquid Rating Primary voltage Secondary voltage Single-phase Three-phase Single-phase Three-phase Voltage 34.5 kv and below 600V and below 10 833 15 500 10 833 15 500 Transformers that are currently specifically excluded from the scope of NEMA Standard TP-1-00 include: Liquid-filled transformers below 10 Dry-type transformers below 15 AC and DC drives transformers Rectifier transformers designed for high harmonics Autotransformers Non-distribution transformers, such as UPS transformers Special impedance or regulation transformers Regulating transformers Sealed and non-ventilated transformers Machine tool transformers Welding transformers Transformers with tap ranges greater than 15% Transformers with a frequency other than 60 Hz Grounding transformers Testing transformers Efficiency levels set forth in NEMA TP-1-00. NEMA TP-1-00 Efficiency Levels Tables of Energy Efficiency NEMA Class 1 Efficiency Levels Dry-Type Distribution Transformers Low Voltage (600V and below) Single-Phase Three-Phase Efficiency Efficiency 15 97.7 15 97.0 5 98.0 30 97.5 37.5 98. 45 97.7 50 98.3 75 98.0 75 98.5 11.5 98. 100 98.6 150 98.3 167 98.7 5 98.5 50 98.8 300 98.6 333 98.9 500 98.7 750 98.8 1000 98.9 V-T- Volume Commercial Distribution CA08100003E June 014 www.eaton.com

Transformers.1 Features, Benefits and Functions 60 Hz operation (except as noted) Short-term overload capability as required by ANSI Meet NEMA ST-0 sound levels Meet federal energy efficiency requirements for low voltage dry-type distribution transformers effective as of January 1, 007 Standards and Certifications UL listed Industry Standards All Eaton dry-type distribution and control transformers are built and tested in accordance with applicable NEMA, ANSI and IEEE Standards. All 600 volt class transformers are UL listed unless otherwise noted. Seismically Qualified Eaton manufactured dry-type distribution transformers are seismically qualified and exceed requirements of the Uniform Building Code (UBC), International Building Code (IBC) and California Code Title 4. Volume Commercial Distribution CA08100003E June 014 www.eaton.com V-T-3

.1 Transformers Accessories Please refer to Section.7 Page V-T-191. Technical Data and Specifications Frequency Eaton standard dry-type distribution transformers are designed for 60 Hz operation. Transformers required for other frequencies are available and must be specifically designed. Overload Capability Short-term overload is designed into transformers as required by ANSI. Dry-type distribution transformers will deliver 00% nameplate load for one-half hour, 150% load for one hour and 15% load for four hours without being damaged, provided that a constant 50% load precedes and follows the overload. See ANSI C57.96-01.50 for additional limitations. Continuous overload capacity is not deliberately designed into a transformer because the design objective is to be within the allowed winding temperature rise with nameplate loading. Insulation System and Temperature Rise Industry standards classify s and rise as shown below: Insulation System Classification Ambient + Winding Rise + Hot Spot = Temp. Class 40 C 55 C 10 C 105 C 40 C 80 C 30 C 150 C 5 C 135 C 0 C 180 C 40 C 115 C 30 C 185 C 40 C 150 C 30 C 0 C The design life of transformers having different insulation systems is the same the lower-temperature systems are designed for the same life as the higher-temperature systems. Enclosures Eaton s ventilated transformers, Types DS-3 and DT-3, use a NEMA rated (drip-proof) enclosure as standard, and are rated NEMA 3R with the addition of weathershields. Winding Terminations Primary and secondary windings are terminated in the wiring compartment. Encapsulated units have copper leads or stabs brought out for connections. Ventilated transformers have leads brought out to terminals that are pre-drilled to accept Cu/Al lugs. Aluminum-wound transformers have aluminum terminals; copper-wound models have copper terminals. Lugs are not supplied with these transformers. Eaton recommends external cables be rated 90 C (sized at 75 C ampacity) for encapsulated designs and 75 C for ventilated designs. Series-Multiple Windings Series-multiple windings consist of two similar coils in each winding that can be connected in series or parallel (multiple). Transformers with series-multiple windings are designated with an x or / between the voltage ratings, such as voltages of 10/40 or 40 x 480. If the series-multiple winding is designated by an x, the winding can be connected only for a series or parallel. With the / designation, a mid-point also becomes available in addition to the series or parallel connection. As an example, a 10 x 40 winding can be connected for either 10 (parallel) or 40 (series), but a 10/40 winding can be connected for 10 (parallel), or 40 (series), or 40 with a 10 mid-point. For additional information, please refer to Section.7 Page V-T-191. Sound Levels All Eaton 600 volt class general-purpose dry-type distribution transformers are designed to meet NEMA ST-0 sound levels listed here. These are the sound levels measured in a soundproof environment. Actual sound levels measured at an installation Average Sound Levels 1 NEMA ST-0 Average Sound Level in db will likely be higher (as much as 15 db greater) due to electrical connections and environmental conditions. Lower sound levels are available and should be specified when the transformer is going to be installed in an area where sound may be a concern. Up to 1. kv Above 1. kv Ventilated Encapsulated Ventilated 0 9 40 45 45 10 50 45 50 50 51 150 50 55 55 151 300 55 57 58 301 500 60 59 60 501 700 6 61 6 701 1000 64 63 64 1001 1500 65 64 65 Notes 1 Currently being reviewed and revised by NEMA. For other ratings or styles not shown, or for special enclosure types (including stainless steel), refer to Eaton. V-T-50 Volume Commercial Distribution CA08100003E June 014 www.eaton.com

.6 Transformers Transformer Standards, Technical Data and Accessories Standards and Certifications Eaton dry-type distribution transformers are approved, listed, recognized or may comply with the following standards. Engineering Standards Catalog Product Name UL Standard 1 Notes 1 UL 5085 replaces UL 506. Applies to 5 50. 3 Applies to 5. 4 Applies to 15 5. 5 Applies to 37.5. 6 Applies to 3. 7 Applies to 5 9. 8 Applies to 30 75. 9 Applies to 30. UL/cUL File Number UL Listed Control Number cul Energy Efficiency File Number In addition to the above standards, Eaton dry-type distribution transformers are also manufactured in compliance with the applicable standards listed below. Not all of the following standards apply to every transformer. NEC: National Electrical Code NEMA ST-1: Specialty Transformers (C89.1) (control transformers). NEMA ST-0: General-Purpose NEMA TP-1: Guide for Determining Energy Efficiency for Distribution NEMA 50: Enclosures for Electrical Equipment (1000 volts maximum). IEEE C57.1.01: General Requirements for Dry-Type Distribution and Power Transformers (including those with solidcast and/or resin-encapsulated windings). CSA File Number Insulation System Temp/ºC ANSI C57.1.70: Terminal Markings and Connections for Distribution and Power ANSI C57.1.91: Standard Test Code for Dry-Type Distribution and Power CSA C No. 47-M90: Air-Cooled Transformers (Dry-Type). CSA C9-M1981: Dry-Type CSA C. No. 66: Specialty CSA 80-94: Maximum Losses for Distribution, Power and Dry-Type NEMA TP-: Standard Test Method for Measuring the Energy Consumption of Distribution NEMA TP-3 Single- Phase Three- Phase Applicable IEC Standard Industrial Control Transformer MTE 5085 E4633 70X LR7533 105 0.05 1.5 N/A 61558 MTK 5085 E4633 70X LR7533 180 0.05 5 N/A 61558 Encapsulated Transformer AP 5085 E10156 591H 180 3 10 N/A 61558 AP 1561 E78389 591H 180 15 N/A 61558 EP 5085 E10156 591H LR60545 180 0.05 10 N/A 61558 EP 1561 E78389 591H EV157 LR60545 3 180 15 50 N/A 61558 4 / 76 5 EPT 5085 E10156 591H LR60545 180 N/A 3 9 61558 6 / 76 7 EPT 1561 E78389 591H EV157 8 LR60545 9 180 N/A 15 75 76 MPC 106 E53449 591H LR60546 180 3 5 15 30 Ventilated Transformer DS-3 1561 E78389 591H 0 15 167 N/A 6076 DT-3 1561 E78389 591H 0 N/A 15 750 6076 KT 1561 E78389 591H 0 N/A 9 500 N/A V-T-186 Volume Commercial Distribution CA08100003E June 014 www.eaton.com

Transformers Transformer Standards, Technical Data and Accessories.6 Catalog Number Selection General-Purpose, Energy-Efficient, Mini Power Center, Shielded Isolation, Nonlinear, Buck-Boost, Marine Duty Transformers Example: S0N11S05A C Prefix Options = CSA labeled ventilated transformer Marine Duty QS = EPM marine (1-Ph encapsulated) LY = EPTM Marine (3-Ph encapsulated) RT = DS-3M marine (1-Ph ventilated) MV = DT-3M marine (3-Ph ventilated) Type S = EP (single-phase encapsulated) Y = EPT (three-phase encapsulated) T = DS-3 (single-phase ventilated) V = DT-3 (three-phase ventilated) P = Mini power center Z = Class 1 Division Groups A, B, C, D X = Harmonic mitigating (three-phase ventilated) Nonlinear H = KT-4 (three-phase ventilated) B = KT-9 (three-phase ventilated) N = KT-13 (three-phase ventilated) G = KT-0 (three-phase ventilated) J = KT-30 (three-phase ventilated) A = KT-40 (three-phase ventilated) K = KT-50 (three-phase ventilated) HT = KT-4 (single-phase ventilated) NT = KT-13 (single-phase ventilated) GT = KT-0 (single-phase ventilated) Notes 1 Model number is not used on newly designed/redesigned transformers. Copper windings. 3 Grade 304 stainless steel enclosure (does not imply a NEMA 4X rating). 4 Open type core and coil assembly. 5 Totally enclosed non-ventilated DS-3 or DT-3. 6 50/60 Hz. 7 Low sound design. LS47 indicates low sound equal to 47 db; LS4 indicates 4 db. Primary Voltage 13 = 110 x 0 1 = 10 10 = 10 x 40 9 = 08 7 = 00 5 = 0 3 = 30 4 = 40 0 = 40 x 480 7 = 77 38 = 380 39 = 400 43 = 416 44 = 440 45 = 450 48 = 480 57 = 575 60 = 600 4 = 400 46 = 4160 49 = 4800 40 = Export model 54 = 10/08/40/77 Taps D = at +.5%, at.5% E = 1 at +5%, 1 at 5% F = 1 at 10% G = at 5% J = 4 at.5% K = 1 at 10% x at 5% L = at 5% x 4 at.5% M = at +.5%, 4 at.5% N = None R = 1 at +5%, at 5% P = 1 at +5%, at 5% x at +.5%, 4 at.5% T = 1 at +4.%, 1 at 4.% U = 1 at +.5%, 3 at.5% W = 1 at +3.5%, 1 at 3.5% X = at +3.1%, at 3.1% 8 Fungus proof. 9 Certified test report of standard production tests for the specific serial number to be shipped. j Certified sound level report. k CE Marked. l Thermal indicator embedded in center coil. Suffix TT indicates two thermal indicators of different temperature ratings, are installed. m NEMA TP-1 efficient. T S 0 N 11 S 05 A 81 =0.05 85 = 0.075 8 =0.10 83 =0.15 6 =0.5 51 =0.50 76 =0.75 01 =1 16 =1.5 0 = T = 150 C rise with 0 C F = 115 C rise with 0 C B = 80 C rise with 0 C H = 130 C rise with 00 C G = 115 C rise with 00 C 04 = 1/4 06 = 16/3 08 = 4/48 14 = 110/0 1 = 10 10 = 10 x 40 11 = 10/40 54 = 17/54 19 = 190Y/110 8 = 08Y/10 9 = 08 5 = 0 delta 31 = 0Y/17 6 = 0 delta/110 midtap = 40 delta/10 midtap 64 = 40Y/139 4 = 40 delta 03 =3 05 =5 06 =6 07 =7.5 09 =9 10 =10 15 =15 1 =.5 5 =5 30 =30 Temperature Rise Secondary Voltage 37 =37.5 45 =45 50 =50 75 =75 99 =100 1 = 11.5 49 =150 67 =167 =5 n 0 phase-shift (used with HMTs). o +15 phase-shift (used with HMTs). p 15 phase-shift (used with HMTs). q 30 phase-shift (used with HMTs). r CSL3 DOE 007 energy-efficient. s NEMA 4X Grade 304 stainless steel enclosure. t Easy install base. BK Grade 316 stainless steel enclosure (does not imply NEMA 4X rating). BL Integral -inch infrared viewing window. BM Integral 3-inch infrared viewing window. BN Integral 4-inch infrared viewing window. BO NEMA Premium Efficient. J = 80 C rise with 0 C P = 115 C rise with 130 C (encapsulated) S = 115 C rise with 180 C (encapsulated and MPC) L = 80 C rise with 180 C (encapsulated and MPC) 0 = 40 x 480 1 = 40/480 7 = 77 38 = 380 delta 37 = 380Y/0 34 = 400Y/31 51 = 416Y/40 35 = 440Y/54 6 = 460Y/66 47 = 480Y/77 48 = 480 delta 60 = 600 delta 61 = 600Y/346 4 = 400 41 = 4160Y/400 46 = 4160 49 = 4800 5 = 50 33 = 300 54 = 333 55 = 500 60 = 600 77 = 750 11 = 1000 14 = 1500 Suffix Options A...Y = 1 CU = SS = 3 ZZ = 4 NV = 5 X = 6 LS = 7 AF = 8 TR = 9 SR = j CE = k T = l EE = m NON = n POS = o NEG = p THR = q E3 = r SS4X = s Z = t S6 = BK I = BL I3 = BM I4 = BN N3 = BO For Eaton s industrial control transformers catalog number selection, see Page V-T-188. Contact your local Eaton sales office for voltage combinations not shown. Use table for catalog number breakdown only. Do not use to create catalog numbers because all combinations may not be valid. Volume Commercial Distribution CA08100003E June 014 www.eaton.com V-T-187