CP-T range Product group picture

Similar documents
CP-T range Benefits and advantages

CP-E range Benefits and advantages

Primary switch mode power supplies Product group picture

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-E 24/20.0

Power supply CP-E 24/2.5

Type CP-S, CP-C & CP-A Switch mode

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 24/0.75

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-E 24/2.5

Power supply CP-D 12/2.1

Power supply CP-D 24/1.3

Three-phase monitoring relays CM-PFE and CM-PFE.2

Electronic timer CT-TGD.22

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-SDD.22

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PVE

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-SDS.22

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Switching power supplies CP range, Linear power supplies CP-L range. Content

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Liquid level monitoring relay CM-ENS.2x

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

QUINT-PS AC/24DC/40

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

QUINT-PS/ 3AC/24DC/10

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

MINI-PS AC/24DC/1.3

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

For Immediate Delivery call KMParts.com at (866)

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Three-phase monitoring relays

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

QUINT-PS/ 3AC/24DC/40

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Three-phase monitoring relay CM-PBE

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

QUINT-PS-24DC/24DC/10

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

MINI-PS AC/2X15DC/1

QUINT-PS/ 1AC/24DC/20

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Control module CP-A CM

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Electronic timer CT-MFS.21

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Output Voltage* (nom.)(adjustable)

Analog signal converters CC range

Three-phase monitoring relays Product group picture

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Three-phase monitoring relays Table of contents

Three-phase monitoring relays Product group picture

Three-phase monitoring relay

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Thermistor motor protection relays

Subject to changes 11/2003 Page 1/7

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Signal converters Index

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Transcription:

Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09

Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details / Technical data /5 Technical diagrams, Dimensional drawings /9 Technical diagrams / 2CDC 110 00 09 Catalog Electronic Products and Relays 1/1 ABB /2

Benefits and advantages Characteristics J Rated output voltages V, V DC J Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust J Rated output currents 5 A, 10 A, A, A J Rated output powers 1 W, 0 W, W, 960 W J Three-phase or two-phase operation (see derating note) J Supply range x 0 500 V AC ( x 575 V AC, V DC) J Typical efficiency of 9 % J Low power dissipation and low heating J Free convection cooling (no forced cooling with ventilators) J Ambient temperature range during operation -...+70 C 1) J Open-circuit, overload and short-circuit stable J Integrated input fuse J Redundancy unit CP-A RU offering true redundancy, available as accessory J LEDs for status indication J Signalling contact "1-1" (solid state) for output voltage OK Benefits Signalling output 1 The devices of the CP-T series offer a solid state output for function monitoring and remote diagnostics. Wide input range Wide range input optimized for world-wide applications: The CP-T power supplies can be used in - 575 V AC or - V DC supply systems. Adjustable output voltage 2 The CP-T range feature a continuously adjustable output voltage. Thus, they can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. J Approvals / marks (depending on device, partly pending): A, H D, E / a, b 1) W variants: -0...+70 C 1 2 2CDC 271 0 S0009 2CDC 271 0 S0009 1 Circuit diagram 2 Indication of operational states DC ON: green LED green LED output voltage OK 1 DC LOW: red LED output voltage too low single/parallel: sliding switch - adjustment of single or parallel operation Configuration of single or parallel operation 2 5 7 5 Signalling contact OUTPUT 1-1: terminals - signalling contact A solid-state output indicates the error-free operation of the output voltage. OUTPUT L+, L+, L-, L-: terminals - output 7 INPUT L1, L2, L, PE: terminals - input / ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09

Ordering details CP-T /5.0 2CDC 271 0 S0009 Description The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality, the new range perfectly supplements the existing products and extends the range appropriately. The devices can be supplied with a three-phase voltage as well as with two-phase mains. Here, ABB offers power supply units with V DC and V DC outputs with 5 A, 10 A, A and A and efficiency of up to 92 %. As in the case of all products, they are designed for an ambient temperature of up to 70 C. All products can be supplied within an AC supply voltage range between to 575 V AC and a DC supply voltage range between to V DC. Ordering details Input voltage range Rated output voltage / current Type Order code Price 1 pce Weight (1 pce) kg (lb) -575 V AC / - V DC V DC / 5 A CP-T /5.0 1SVR2705R0000-575 V AC / - V DC V DC / 10 A CP-T /10.0 1SVR27055R0000-575 V AC / - V DC V DC / A CP-T /.0 1SVR27056R0000 0.0 (1.77) 1.05 (2.1) 1.75 (.6) 2CDC 271 05 S0009-575 V AC / - V DC V DC / A CP-T /.0 1SVR27057R0000-575 V AC / - V DC V DC / 5 A CP-E /5.0 1SVR2705R00. (7.05) 1.05 (2.1) CP-T /10.0, CP-T /5.0-575 V AC / - V DC V DC / 10 A CP-E /10.0 1SVR27055R00-575 V AC / - V DC V DC / A CP-E /.0 1SVR27056R00 1.75 (.6). (7.50) 2CDC 271 07 S0009 CP-T /.0, CP-T /10.0 2CDC 110 00 09 Catalog Electronic Products and Relays 1/1 ABB /

Technical data Data at T a = 25 C, U in = x 0 V AC and rated values, unless otherwise indicated Type CP-T /5.0 CP-T /10.0 CP-T /.0 CP-T /.0 Input circuit L1, L2, L Rated input voltage U in x 0-500 V AC Input voltage range -575 V AC - V DC Frequency range AC 7-6 Hz Typical input current 0.6 A 0.65 A 1.1 A 1.72 A Typical power consumption 15 W 270 W 5 W 105 W Inrush current limiting 10 A A 0 A Power failure buffering time min. ms min. 15 ms Internal input fuse per phase 2 A / 600 V AC T.15 A / 500 V AC T 5 A / 500 V AC Recommended backup fuse pole miniature circuit breaker ABB Type S Power factor correction (PFC) Yes, passive Discharge current towards PE <.5 ma input / output < 0.25 ma Indication of operational states Output voltage OUTPUT OK: green LED output voltage OK OUTPUT LOW: red LED output voltage too low Output circuit L+, L+, L-, L- Rated output voltage V DC Tolerance of the output voltage 0...+1 % Adjustment range of the output voltage 22.5-2.5 V DC Rated output power 1 W 0 W W 960 W Rated output current I r Ta 60 C 5 A 10 A A A Derating of the output current 60 C < Ta 70 C 2.5 %/ C.5 %/ C Signalling contact 1-1 solid state (max. 60 V DC, 0. A) for output voltage OK Threshold 17.6-19. V Insulation voltage 500 V DC Mininum fuse rating to achieve short-circuit protection 1-1 M 60 V DC, m 0. A fast-acting Maximum deviation with load change statical ±1 % ±1 % (single mode) - ± 5 % (parallel mode) change of output voltage ± 0.5 % within the input voltage range Control time at nominal load < 2 ms Starting time after applying at I r max. 1 s the supply voltage with 500 µf max. 1.5 s Rise time at nominal load max. 150 ms with 500 µf max. 500 ms Fall time max. 150 ms Residual ripple and switching peaks BW = MHz 100 mv 0 mv Parallel connection not supported configurable, to increase power, up to 2 devices, min. 0.1 I r - max 0.9 I r ) Series connection not supported yes, to increase voltage, max. 2 devices Resistance to reverse feed approx. 5 V Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output combined U/I characteristic curve and hiccup mode continuous short-circuit proof current limiting hiccup mode continuous no-load stability U/I- or Hiccupmode adjustable to increase power, up to 2 devices, min. 0.1 I r - max. 0.9 I r use active current balancing hiccup / fold back behavior Short-circuit protection Short-circuit behaviour Overload protection No-load protection Overtemperature protection yes, automatic recovery after temperature went down Starting of capacitive loads 500 µf 7000 µf 7000 µf 7000 µf /5 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09

Technical data Data at T a = 25 C, U in = x 0 V AC and rated values, unless otherwise indicated Type CP-T /5.0 CP-T /10.0 CP-T /.0 CP-T /.0 General data Efficiency typ. 9 % typ. 90 % typ. 92 % Duty time 100% Dimensions (W x H x D) 7. x 1 x 11. mm (2.92 x. x.6 in) 9 x 1 x 11. mm (.5 x. x.6 in) 150 x 1 x 11. mm (5.91 x. x.6 in) 275. x 1 x 11. mm (10.6 x. x.6 in) Weight 0.7 kg (1.72 lb) 1.05 kg (2.0 lb) 1.657 kg (.65 lb).275 kg (7.2 lb) Material of housing Metal Mounting DIN rail (IEC EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.9 in / 0.9 in) Degree of protection housing / terminals IP / IP Protection class I Electrical connection - input circuit / output circuit / signalling circuit Wire size fine-strand with wire end ferrule 0,2- mm² (-11 AWG) fine-strand without wire end ferrule 0,2-6 mm² (-10 AWG) rigid 0,2-6 mm² (-10 AWG) Stripping length mm (0.1 in) Tightening torque input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in) 1 Nm (9 lb.in) / 1. Nm (15.6 lb.in) Environmental data Ambient temperature range operation -...+70 C -0 +70 C -...+70 C rated load -...+60 C -0 +60 C -...+60 C storage - +5 C Damp heat (cyclic) (IEC/EN 6006-2-0) 95 % without condensation Vibration (sinusoidal) (IEC/EN 6006-2-6) 2 g, 10-500 Hz, 2G, each along X, Y, Z axes 60 min / cycle Shock (half-sine) (IEC/EN 6006-2-27) 15 g, 11 ms, axes, 6 faces, times for each face Isolation data Rated insulation voltage U i input circuit / output circuit kv AC input / PE 1.5 kv AC output / PE 0.5 kv AC; 0.71 kv DC signalling output / PE 0.5 kv DC Pollution degree 2 Standards Product standard EN 61- Low Voltage Directive 06/95/EC EMC directive 0/10/EC RoHS directive 02/95/EC Electrical safety EN 60950-1, UL 60950-1, UL 50, EN 6155-1, EN 6155-2-17; EN 60-1 Protective low voltage SELV Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000--2 Level (air discharge 15 kv / contact discharge kv) radiated, radio-frequency, electromagnetic field IEC/EN 61000-- Level (10 V/m) electrical fast transient/burst IEC/EN 61000-- Level ( kv / 2.5 khz) Level ( kv / 5 khz) surge IEC/EN 61000--5 L-L Level (2 kv) / L-PE Level ( kv) conducted disturbances, induced by radio-frequency fields IEC/EN 61000--6 Level (10 V) power frequency magnetic fields IEC/EN 61000-- Level (0 A/m) voltage dips, short interruptions and voltage variations IEC/EN 61000--11 dips: >95 % 0.5 ms / >0 % 0.5 ms, interruptions: >95 % 250 ms Interference emission IEC/EN 61000-6- high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B limits for harmonic current emissions IEC/EN 61000--2 Class A Approvals and marks on page /. 2CDC 110 00 09 Catalog Electronic Products and Relays 1/1 ABB /6

Technical data Data at T a = 25 C, U in = x 0 V AC and rated values, unless otherwise indicated Type CP-T /5.0 CP-T /10.0 CP-T /.0 Input circuit L1, L2, L Rated input voltage U in x 0-500 V AC Input voltage ranget -575 V AC - V DC Frequency range AC 7-6 Hz Typical input current 0.65 A 1.1 A 1.72 A Typical power consumption 26 W 55 W 1050 W Inrush current limiting A 0 A Power failure buffering time min. ms min. 15 ms Internal input fuse per phase 2 A / 600 V AC T.15 A / 500 V AC T 5 A / 500 V AC Power factor correction (PFC) yes, passive Discharge current towards PE <.5 ma input / output < 0.25 ma Indication of operational states Output voltage OUTPUT OK: green LED output voltage OK OUTPUT LOW: red LED output voltage too low Output circuit L+, L+, L-, L- Rated output voltage V DC Tolerance of the output voltage 0...+1 % Adjustment range of the output voltage 7-56 V DC Rated output power 0 W W 960 W Rated output current I r T a 60 C 5 A 10 A A Derating of the output current 60 C < T a 70 C 2.5 %/ C.5 %/ C Maximum deviation with load change statical ±1 % (single mode) ± 5 % (parallel mode) change of output voltage within the ±0.5 % input voltage range Control time at rated load < 2 ms Starting time after applying the supply voltage at Ir max. 1 s with 7000 µf max. 1.5 s Rise time at rated load max. 150 ms with 7000 µf max. 500 ms Fall time max. 150 ms Residual ripple and switching peaks BW = MHz 100 mv 0 mv Parallel connection configurable, to increase power, up to 2 devices, min. 0.1 I r - max 0.9 I r ) to increase power, up to 2 devices, min. 0.1 I r - max. 0.9 I r use active current balancing Series connection yes, to increase voltage, max. 2 devices Resistance to reverse feed approx. 5 V approx. 6 V approx. 6 V Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output combined U/I and hiccup mode U/I or hiccup mode, configurable Short-circuit protection continuous short-circuit proof Short-circuit behaviour current limiting Overload protection hiccup mode No-load protection continuous no-load stability Over temperature protection yes, automatic recovery after temperature went down Starting of capacitive loads 7000 µf hiccup mode / fold back behavior /7 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09

Technical data Data at T a = 25 C, U in = x 0 V AC and rated values, unless otherwise indicated Type CP-T /5.0 CP-T /10.0 CP-T /.0 General data Efficiency typ. 91 % typ. 9 % Duty time 100% Dimensions (W x H x D) 9 x 1 x 11. mm (.5 x. x.6 in) 150 x 1 x 11. mm (5.91 x. x.6 in) 275. x 1 x 11. mm (10.6 x. x.6 in) Weight 1.05 kg (2.0 lb) 1.657 kg (.65 lb).275 kg (7.22 lb) Material of housing Metal Mounting DIN rail (IEC EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.9 in / 0.9 in) Degree of protection housing / terminals IP / IP Protection class I Electrical connection - input circuit / output circuit Wire size fine-strand with wire end ferrule 0.2- mm² (-11 AWG) 0.2- mm² (-11 AWG) / 0.5-10 mm² (- AWG) fine-strand without wire end ferrule 0.2-6 mm² (-10 AWG) rigid Stripping length mm (0.1 in) Tightening torque input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in) 1 Nm (9 lb.in) / 1. Nm (15.6 lb.in) Environmental data Ambient temperature range operation - +70 C -0 +70 C - +70 C rated load - +60 C -0 +60 C - +60 C storage - +5 C - +5 C - +5 C Damp heat (cyclic) (IEC/EN 6006-2-0) 95 % without condensation Vibration (sinusoidal) (IEC/EN 6006-2-6) 10-500 Hz, 2G, each along X, Y, Z axes 6 min / cycle Shock (half-sine) (IEC/EN 6006-2-27) 15G, 11 ms, axes, 6 Faces, times for each face Isolation data Rated insulation voltage U i input circuit / output circuit kv AC input / PE 1.5 kv AC output / PE 0.5 kv AC; 0.71 kv DC Pollution degree 2 Standards Product standard EN 61- Low Voltage Directive 06/95/EC EMC directive 0/10/EC RoHS directive 02/95/EC Electrical safety EN 60950-1, UL 60950-1, UL 50, EN 6155-1, EN 6155-2-17; EN 60-1 Protective low voltage SELV Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000--2 Level (air discharge 15 kv / contact discharge kv) radiated, radio-frequency, electromagnetic field IEC/EN 61000-- Level (10 V/m) electrical fast transient/burst IEC/EN 61000-- Level ( kv / 5 khz) surge IEC/EN 61000--5 L-L Level (2 kv) / L-PE Level ( kv) conducted disturbances, induced by radio-frequency fields IEC/EN 61000--6 Level (10 V) power frequency magnetic fields IEC/EN 61000-- Level (0 A/m) voltage dips, short interruptions and voltage variations IEC/EN 61000--11 dips: >95 % 0.5 ms / >0 % 0.5 ms interruptions: >95 % 250 ms Interference emission IEC/EN 61000-6- high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B limits for harmonic current emissions IEC/EN 61000--2 Class A Approvals and marks on page /. 2CDC 110 00 09 Catalog Electronic Products and Relays 1/1 ABB /

Technical diagrams, Dimensional drawings Technical diagrams Output curve at T U = 25 C dimensions in mm 2 12 @ x 0V supply @ x 500V supply 2CDC 272 02 F0x09 2 12 @ x 0V supply @ x 500V supply 2CDC 272 0 F0x09 2 12 @ x 0V supply @ x 500V supply 2CDC 272 0 F0x09 1 2 5 6 7 Iout [A] 2 6 10 12 1 Iout [A] 12 2 2 Iout [A] CP-T /5.0 CP-T /10.0 CP-T /.0 U/I curve U out in V 2 12 @ x 0V supply @ x 500V supply 2CDC 272 05 F0x09 2 12 @ x 0 V supply U/I after 5-10 s overload 2CDC 272 027 F0211 56 2 @ x 0V supply @ x 500V supply 2CDC 272 07 F0x09 12 2 2 Iout [A] 2 56 6 72 0 Iout in A 1 2 5 6 7 Iout [A] CP-T /.0 CP-T /.0 CP-T /5.0 56 2 @ x 0V supply @ x 500V supply 2CDC 272 0 F0x09 56 2 @ x 0V supply @ x 500V supply 2CDC 272 09 F0x09 U out in V 56 2 @ x 0 V supply U/I after 5-10 s overload 2CDC 272 02 F0211 2 6 10 12 1 Iout [A] 2 6 10 12 1 Iout [A] 12 2 2 6 Iout in A CP-T /10.0 U/I curve CP-T /10.0 CP-T /.0 Dimensional drawings dimensions in mm CP-T /5.0 2CDC 272 021 F0009 9,5 150 5,91 275. 10.6 11 5, 1, 2CDC 272 022 F0009 11 5, 1, 2CDC 272 02 F0009 11 5. 1. 2CDC 272 0 F0009 CP-T /10.0, CP-T /5.0 CP-T /.0, CP-T /10.0 CP-T /.0, CP-T /.0 /9 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09

Technical diagrams Temperature curve at rated load P out [%] P out [%] 100 90 0 70 60 50 0 10 2CDC 272 026 F0211 100 90 0 70 60 50 0 10 2CDC 272 00 F0211-60 70 CP-T /.0, CP-T /.0 T a [ C] -0 60 70 CP-T /.0, CP-T /10.0 T a [ C] P out [%] 100 90 0 70 60 50 0 10 2CDC 272 025 F0211-60 70 CP-T /5.0, CP-T /10.0, CP-T /5.0 T a [ C] 2CDC 110 00 09 Catalog Electronic Products and Relays 1/1 ABB /