Mikrotik MUM Venice, Italy February 21, Copyright 2014 Winters Broadband LLC 1

Similar documents
Mikrotik MUM St. Louis, MO September 19, Copyright 2013 Winters Broadband LLC 1

Maksat Coral Wireless Broadband Solutions

Canopy Backhaul Portfolio. Motorola s flexible MOTOwi4 backhaul solutions

Vivato Extended Range Wi-Fi Solutions

Motorola s Wireless Broadband Point-to-Point Solutions. The PTP 100, 400 & 600 Series Part of Motorola s MOTOwi4 portfolio

MaxCS Release 8.5 Update 1 Polycom D60 Configuration Guide

Connecting the automated field Building blocks for the modern field network

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

AirMax DUO Lite a/b/g Dual Radio Base Station. Hi-Power Dual Band. Dual. Mode. WISP Network. 5GHz IP-65. Radio2

AW5802xTP. User s Manual. 5.8 GHz Outdoor Wireless Ethernet Panel. AvaLAN. Industrial-grade, long-range wireless Ethernet systems

2.4GHz/5GHz 300Mbps Outdoor CPE

2.4GHz/5GHz 300Mbps Outdoor CPE

Msystems Ltd. 2.4GHz/5GHz 300Mbps Outdoor CPE. Highlights. Pharos CPE Series Datasheet. -Wireless N speed up to 300Mbps

ABC Company. Greenville, SC VIRTUAL SITE SURVEY REPORT

RSSI LED IP-67. Virtual. HTTPS WISP Bridge

UPS (Uninterruptible Power Supply) Digital Signal Processor CM COMANDOS LINEARES CM COMANDOS LINEARES

LinkAlign-60RPT Set-up and Operation Manual

MSC-235. Design and Deploy for MOTOTRBO Connect Plus Solutions BETA. Exam.

Base Station Commissioning

Phone: Fax: Mentor Radio, LLC. Airport Wireless Integrated Connectivity System (AWICS)

Omni. Omni. Next-Gen 2x2 Dual Polarity MIMO Omni Antenna. Datasheet. Models: AMO-2G10, AMO-2G13, AMO-5G10, AMO-5G13. Hi-Performance, Long Range

2.4GHz/5GHz 300Mbps Outdoor CPE

Cambium PMP 450 Series PMP 430 / PTP 230 Series PMP/PTP 100 Series Release Notes

NetPoint Pro. 6x2.4, 6x5.8, 3x2.4, 3x5.8. Wi-Fi base Stations Providing Superior Connectivity

RADWIN 2000 PORTFOLIO

UCP-Config Program Version: 3.28 HG A

Omni Next-Gen 2x2 Dual Polarity MIMO Omni Antenna. Datasheet. Models: AMO-2G10, AMO-2G13, AMO-3G12, AMO-5G10, AMO-5G13. High Performance, Long Range

Frequency selective monitoring and logging of environmental electromagnetic fields

LigoSU 5-N/ 5-20/ 5-23

Hybrid SCADA Communication

SG-IOT SMART WIRELESS. for Lighting Controls 2019 CATALOG.

AW5802xTR. User s Manual. 5.8 GHz Outdoor Wireless Ethernet Radio. AvaLAN. Industrial-grade, long-range wireless Ethernet systems

DH-PFM880-A. Outdoor 5G Wireless video transmission device (AP) Features

RADWIN JET POINT-TO-MULTIPOINT BEAMFORMING SOLUTION DELIVERS FIBER-LIKE CONNECTIVITY FOR RESIDENTIAL AND ENTERPRISE

The Speaker. 20 years in Networking. First Half doing Integration Second Half on Products. 5 years building Wi-Fi

AW2400iTR USER S MANUAL 2.4 GHz Indoor Wireless Ethernet Radio

Safety and alarming applications using ISA100 Wireless

Addressable Radios for Emergency Alert (AREA): WorldSpace Satellite Radio

Warehouse Instruction Guide

NanoTimeLapse 2015 Series

Four Simple Steps to Get Started

Airborne Satellite Communications on the Move Solutions Overview

Antenna Pointing Guide

10/17/2011. I have an Air-Card. I have Satellite Internet. Why would I use Wi-Fi? Just for

Leica Spider Infrastructure HW Solutions Introducing: Leica GR30 & GR50

Capability Statement

IPSTAR Disaster Recovery and Emergency Communications

Successful Installation. VPN Solutions. Lorem ipsum. Branch Connectivity.

Communicator II WIRELESS DATA TRANSCEIVER

M O D U L E - 7 D Model CS-CAL/DLIU V6.0 Operator s Manual

MATERIAL SPECIFICATIONS FOR WIRELESS LINK

500 Series AP and SM CAP and CSM Licensed, Reliable Wireless Connectivity

GEONICA, S.A. - Alejandro Rodríguez, nº Madrid - Spain Tel Fax

CamFi TM. CamFi User Guide. CamFi Remote Camera Controller. CamFi Limited Copyright 2015 CamFi. All Rights Reserved.

Addressing WISPs Strategic Challenges

907,10 PLN brutto 737,40 PLN netto

LigoDLB MACH 5. 5 GHz high-capacity wireless device COPYRIGHT 2017 LIGOWAVE

FULL PERFORMANCE USING STANDARD POE The AP 6532 is designed to provide full n performance using standard and lower cost POE (af).

Pro Range SIL PICO SIL MICRO SIL LITE SIL MAX SIL BASE. 5.1GHz 5.8GHz Wireless Links

RSSI LED IP-67. Virtual. HTTPS WISP Bridge

Continuous, remote monitoring and logging of electromagnetic fields

Slim Audio Interface 4-Wire Quick Start Guide

PALS 9K System Design Overview.

Next-Gen 2x2 Dual Polarity MIMO Omni Antenna. Datasheet. Models: AMO-2G10, AMO-2G13, AMO-3G12, AMO-5G10, AMO-5G13. High Performance, Long Range

wireless products engineered and manufactured for utilities smart grid, automated meter infrastructure and distribution

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual

HT1100 Satellite Modem User Guide

So like many things in life, the answer to what is HamWAN is complicated. There are actually two or three definitions and all are completely valid.

CAST Application User Guide

Huawei Outdoor Wireless Backhaul Solution

9/2/2013 Excellent ID. Operational Manual eskan SADL handheld scanner

Key Features. Base-line surveys for planning Construction site monitoring Road traffic noise monitoring

DIMETRA EXPRESS DATA SHEET DIMETRA EXPRESS

Simrad R5000 IMO/Solas Type Approved Radar Systems

ENCOM STRATOS Plus Release Notes

Microwave Radio Rapid Ring Protection in Pubic Safety P-25 Land Mobile Radio Systems

Above All. The most sophisticated unit for tracking containers in real time for security and management.

Cutting-edge Technology for Data and Communications

Airmux-400 Broadband Wireless Multiplexer

Datasheet. Tag Piccolino for RTLS-TDoA. A tiny Tag powered by coin battery V1.1

Quick Start Guide: FLEX-RP-B/FLEX-RP-B-LL. Connect Battery. Warnings

INVENTORY LEAD S INSTRUCTION MANUAL FOR

Install Guide. EMPower03 Power Monitor 1.1

EverBlu. Wireless fixed data collection system

2018 VA APCO-NENA SPRING CONFERENCE PUBLIC SAFETY GRADE AND COMMERCIAL BROADBAND PERFORMANCE. May 2018

High Speed Multimedia in Albuquerque

The modular system for communication, alerting and people search

Dual Waveform VSAT February 2012

RDX Quick Start Guide

Connecting the Radio:

RADWIN JET PtMP Beamforming solution for fiber-like connectivity

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

The wireless alternative to expensive cabling...

RADWIN JET PtMP Beamforming solution delivers fiber-like connectivity for residential and enterprise. 750 Mb

Mobile Activation Case

PRY-CAM BREAKTHROUGH TECHNOLOGY FOR CONDITION ASSESSMENT AND ASSET MANAGEMENT

APS M1P Single-phase Micro-inverter Installation and User Manual

Scan Sat Network S.L.

Wireless Network Deployment Tips and Tricks 2012

SLX-1 Multi-Application GNSS Receiver

Transcription:

Mikrotik MUM Venice, Italy February 21, 2014 Copyright 2014 Winters Broadband LLC 1

Brian Horn Winters Broadband LLC Mikrotik Certified Trainer MTCNA, MTCRE, MTCRCE, MTCINE, MTCUME Winters Broadband WISP Founded 2011 Coverage area over 500 sq. miles 43 Access Point sites 100% rural customer base Over 300 Mikrotik routers Managed router service 200+ Consulting & Training Copyright 2014 Winters Broadband LLC 2

Product Provide an overview of the RB750UP router, its features and specifications Applications Show how the RB750UP can be applied in WISP Access Point applications Scripting Show how the use of scripting can enhance and add value Copyright 2014 Winters Broadband LLC 3

Access Point Site Three Sector antennas Two backhaul links Router Power consumption ~ 44W (1.83A @ 24V) Micro POP (AP) Omni-directional antenna One backhaul link Router Power consumption ~ 20W (0.83A @ 24V) Copyright 2014 Winters Broadband LLC 4

Specifications V IN = 8 to 30 VDC I OUT = Max 1A on a port 1 I OUTMax = 2.2A 1 PoE out on ports 2 to 5 Port Prioritization 1 Port power monitoring 1 Power consumption 2.4 W to 3.6 W Upgrade to version 6.9+ Note: 1. Requires version 2.x PoE-Out controller firmware Copyright 2014 Winters Broadband LLC 5

WinBox Configuration PoE Out Off, Forced On, Auto On PoE Priority Reporting PoE Out Current PoE Out Voltage PoE Out Power CLI Copyright 2014 Winters Broadband LLC 6

Router OSPF for backbone links Increased network availability Power Control Control of attached wireless devices Power monitoring Reduced maintenance costs no truck roll required Bandwidth Control Allows global upload speed to set optimizing backbone utilization Scripting Allows features to be added Enhanced router capability Reduced operating and maintenance costs Copyright 2014 Winters Broadband LLC 7

Solar Array RB750UP Router Charge Controller Wireless Equipment 24V Battery Copyright 2014 Winters Broadband LLC 8

Charge Controller SunSaver SS-20L-24V 24V 20A charge controller with LDV Load Disconnect 23.0 V 11.5 V per battery Load Reconnect 25.2 V 12.6 V per battery? How long between disconnect and reconnect with battery being charged Copyright 2014 Winters Broadband LLC 9

24V 26AH Battery Configuration Two 12V 26AH batteries in connected in series Fully charged 2A load Run time at 2A to 23V disconnect voltage = 13:43 hours 23V is recommended disconnect voltage to avoid battery damage Need longer run time use larger capacity batteries Copyright 2014 Winters Broadband LLC 10

Test with wireless unit Power consumption RM750UP = 80mA Wireless unit = 170 to 330mA Copyright 2014 Winters Broadband LLC 11

24V 26AH Battery configuration Two 12V 26AH batteries connected in series Discharged to 23V disconnect level 3A battery charge rate Charge time = 10:30 hours Time to reconnect voltage of 25.2V = 2:48 hours No power = No service = Support Calls Copyright 2014 Winters Broadband LLC 12

Solar Array RB750UP Router Charge Controller Wireless Equipment 24V Battery Copyright 2014 Winters Broadband LLC 13

Connect the RB750UP directly to the battery array and configure it to provide the LDV Monitor battery voltage Provide alert when battery voltage is < 24V & > 23V Disconnect load when battery voltage < 23V Provide alert, keep router alive PoE voltage readings report the port output voltage For input voltages from 8V to 16V it is -0.5V < input voltage For input voltages from 17V to 30V it is -0.6V < input voltage E.g. 24V input provides a PoE output of 23.4V Copyright 2014 Winters Broadband LLC 14

LDV Script Get system voltage Vpoe If (Vpoe>23.4V) log result Battery fully charged If (Vpoe<23.4V & Vpoe>22.4V) send warning message Battery being discharged If (Vpoe<22.4V) send alert message & take action Battery at LDV point Turn PoE power off If (Vpoe>22.4V) send alert message & take action Turn PoE power on Battery charging. Above LDV point Copyright 2014 Winters Broadband LLC 15

Script that can be executed by other scripts Switches PoE on selected interface/s :global PoePort :global PoeMode :global PoeDelay :local ptr :if ($PoeMode = "ON") do={ # Turn selected PoE port on if ($PoePort=0) do={ :for ptr from=2 to=5 step=1 do={ /interface ethernet poe set "ether$ptr" poe-out=auto-on :delay ($PoeDelay.s) :log info "PoE on port $ptr switched $PoeMode"} } else={ /interface ethernet poe set "ether$poeport" poe-out=auto-on :log info "PoE on port $PoePort switched $PoeMode"} } else={ # Turn selected PoE port off if ($PoePort=0) do={ :for ptr from=2 to=5 step=1 do={ /interface ethernet poe set "ether$ptr" poe-out=off :log info "PoE on port $ptr switched $PoeMode"} } else={ /interface ethernet poe set "ether$poeport" poe-out=off :log info "PoE on port $PoePort switched $PoeMode"} } Copyright 2014 Winters Broadband LLC 16

PoeControl script Single script, multi-function, controlled by variables PoePort Port # or 0 for all ports PoeMode OFF or ON PoeDelay Delay in seconds between startup for all ports PoeControlTest script Enables testing of PoeControl script :global PoePort 0 :global PoeMode "OFF" :global PoeDelay 0 :execute PoeControl Copyright 2014 Winters Broadband LLC 17

Variables :global PoePort :global PoeMode :global PoeDelay :global Vbatlow 234 :global Vbatoff 224 :global Vtest :global TestMode :global Vsystem [/system health get voltage] :local SystemName [/system identity get name] Test mode? Use voltage from test program :if ($TestMode=1) do={:set Vsystem $Vtest} Battery voltage between 23V and 24V alert message :if (($Vsystem < $Vbatlow) && ($Vsystem > $Vbatoff)) do={ :local emessage ("Warning ".$SystemName. " voltage is ". [:pick $Vsystem 0 2]. ".". [:pick $Vsystem 2 3]."V") # /tool e-mail send to="youremail@yourdomain.com" subject="warning $SystemName - Low Voltage" body=$emessage :log info $emessage} Copyright 2014 Winters Broadband LLC 18

Battery voltage below cutoff voltage of 23V activate LDV :if ($Vsystem < $Vbatoff) do={ :local emessage ("Alert ".$SystemName. " voltage is ". [:pick $Vsystem 0 2]. ".". [:pick $Vsystem 2 3]."V") # /tool e-mail send to="youremail@yourdomain.com" subject="alert $SystemName - Powered Down" body=$emessage :log info $emessage :set PoePort 0 :set PoeMode "OFF" :execute PoeControl} Battery voltage above cutoff voltage activate load :if ($Vsystem > $Vbatoff) do={ :local emessage ("Alert ".$SystemName. " voltage is ". [:pick $Vsystem 0 2]. ".". [:pick $Vsystem 2 3]."V") # /tool e-mail send to="youremail@yourdomain.com" subject="alert $SystemName - Powered Up" body=$emessage :log info $emessage :set PoePort 0 :set PoeMode "ON" :set PoeDelay 10s :execute PoeControl} Copyright 2014 Winters Broadband LLC 19

LDV script Control rules and actions to be taken as battery is discharged and charged Testing LDVTest script :global Vtest 226 :global TestMode 1 :execute LDV # Change voltage to test different modes Note: Information on this emailing of messages can be found on the Mikrotik wiki and has therefore not been included in this presentation. Copyright 2014 Winters Broadband LLC 20

RB750UP Router Utility Power 110/220V Battery Charger Wireless Equipment 24V Battery Copyright 2014 Winters Broadband LLC 21

Utility Power 110/220V RB750UP Router Power Supply Battery Charger 26V Wireless Equipment <25.2V 24V Battery Copyright 2014 Winters Broadband LLC 22

Solar Array Wind Turbine RB750UP Router Charge Controller Wireless Equipment Charge Controller 24V Battery Dump Load 24V Battery Copyright 2014 Winters Broadband LLC 23

Netwatch Monitor device IP address and reboot if connectivity is lost Log actions taken Copyright 2014 Winters Broadband LLC 24

Scheduler Set schedule for script to run Script Monitor PoE/System Health Voltage to determine status of DC power feed Reporting Send an alert and report messages Note: Information on this subject can be found on the Mikrotik wiki and has therefore not been included in this presentation. Copyright 2014 Winters Broadband LLC 25

Turning on all loads simultaneously can result in a power spike which can place router in overload condition Sequencing power turn up minimizes power spike Included in LDV script Scheduler Run script after startup Script Put 15s delay between starting each interface Copyright 2014 Winters Broadband LLC 26

Reduce power consumption by powering down devices If battery voltage is reaching critical level, run time can be extended Power down backup link Power down non critical sectors Maximize uptime Keep the router up it provides the control and reports Copyright 2014 Winters Broadband LLC 27

Ideally suited as an Access Point router Routing Bandwidth control Control over powered devices Scripting enhances functionality Cost effective redundant power solutions Highly efficient Low Voltage Disconnect (LDV) Powered equipment monitoring and reboot Power monitoring and reporting Load shedding Copyright 2014 Winters Broadband LLC 28

Copyright 2014 Winters Broadband LLC 29