DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER

Similar documents
Radiation Protection and On-Site Inspection of the Elevated Subway Construction with an Ir-192 Gamma-Source

Film Replacement in Radiographic Weld Inspection The New ISO Standard

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

Computed Radiography

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

Digital Radiology with Photon Counting Detectors

Pre Conference Workshop on Advanced Digital imaging

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams

Advanced Digital Radiography for Field NDT

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Experiences of users in Digital Radiography

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography

Performance evaluation of a photon counting detector for high energy NDT applications

Digital Industrial Radiography

Strategies for Film Replacement in Radiography - a comparative study -

ON THE WAY TO DIGITAL RADIOGRAPHY

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors

Real Time Linear Array Imaging. Brian Caccamise

ScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)

Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications

Fig.2: Scanner VistaScan for image plates

Digital Radiography for the Inspection of Small Defects

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

Amorphous Selenium Direct Radiography for Industrial Imaging

Hardware for High Energy Applications 30 October 2009

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

NEW POSSIBILITIES OF RADIATION CONTROL OF QUALITY OF WELDED JOINTS

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS

The field deployable digital X-Ray solution for weld inspection in O&G

Time Saving in the X-Ray Production Control by using ASD

SINCE2011 Singapore International NDT Conference & Exhibition, 3-4 November 2011

Examination of Pipe Welds by Image Plate Based Computed Radiography System

Half value layer and AEC receptor dose compliance survey in Estonia

The HOIS recommended practice for in-service computed radiography of pipes

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology

5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers

IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison

Spokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales

Gamex CR 2.0 Program description and operating manual

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

FOCUS. Quick Industrial X-ray Testing Without Intermediate Data Carriers of Information. by V.A. Troitskiy

digital radiography r High-energy DT Applications lior Pick, Ron Pincu and Ofra Kleinberger over film radiog- p P This advanced

This document is a preview generated by EVS

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Advances in High Energy X-ray Digital Detector Arrays

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Advancements In Digital Radiography: CR, DR, and DICONDE

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY

UNDERSTANDING THE CHALLENGES IN THE TRANSITION FROM FILM TO DIGITAL RADIOGRAPHY IN THE NUCLEAR POWER INDUSTRY

First Validation of CIVA RT Module with a Linear Accelerator in a Nuclear Context

Flash-Radiography Instead of Traditional Radiography with Intermediate Carriers of Information

UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY

Recommended Training Curriculum For Digital Radiography Personnel (Level II)

Acquisition, Processing and Display

Introduction To NDT. BY: Omid HEIDARY

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

RADIOGRAPHIC EXPOSURE

Gamex Lite 3.0 Program description and operating manual

Digital Imaging Considerations Computed Radiography

HPX1-Plus. For Non-Destructive Testing. THE BENCHMARK IN COMPUTED RADIOGRAPHY.

Computed Radiography of Resistance Temperature Sensor for Indian PHWR

Digital Detector Array Image Quality for Various GOS Scintillators

High Energy Digital Radiography & 3D-CT for Industrial Systems

HIGH RESOLUTION COMPUTERIZED TOMOGRAPHY SYSTEM USING AN IMAGING PLATE

HDRTR (High Definition Real Time Radiography)

Visibility of Detail

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

A NEW LINEAR DETECTOR ARRAY CONCEPT FOR ACCELERATOR BASED DIGITAL RADIOGRAPHY OF THE FINAL DISPOSAL CANISTERS FOR SPENT NUCLEAR FUEL

DEVELOPMENT CENTER X-RAY TECHNOLOGY EZRT XEYE. Radiation proof X-ray detectors for industrial applications

Digital Radiography : Flat Panel

Mobile digital radiography system for nondestructive testing of large diameter pipelines

THE CR SPECIALISTS HD-CR CR 35 NDT

The Evaluation of Collimator Alignment of Diagnostic X-ray Tube Using Computed Radiography System

STUDENT REVIEW QUESTION SET K CR/DR CONTENT AREA

Research Article Digital Radiography Using Digital Detector Arrays Fulfills Critical Applications for Offshore Pipelines

X-ray backscattering: Variable irradiation geometry facilitates new insights

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

In-service inspections for primary coolant circuit components of light water reactors Part 6: Radiographic testing

Digital Profile Radiography Practical uses and limitations

x_ray solutions We understand that customers don t need just products, they want solutions

ISO INTERNATIONAL STANDARD

Digital radiography. bucky table and wall stand as a dual detector or wireless system. Amadeo DR Systems

CR Basics and FAQ. Overview. Historical Perspective

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

SPECTRAL SCANNER. Recycling

Radiographic sensitivity improved by optimized high resolution X -ray detector design.

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

DR _ solutions. We understand that customers don t need just products, they want. solutions

HIGH SPEED, HIGH RESOLUTION AND LOW COST DIGITAL RADIOGRAPHY

Current technology in digital image production (CR/DR and other modalities) Jaroonroj Wongnil 25 Mar 2016

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

Transcription:

14.03.2016 DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS Bernhard REDMER

Digital Technology and Networking Imaging Plates Scanner for Imaging Plates Data Transmission Reporting Computed Radiography Standards available now Archive Film Digitizer Networking Radiology with Digital Detector Arrays Digital Detector Arrays Hard Copy Grayscale Printer Agfa 2

Present Trends in Digital Industrial Radiography NDT Image Capture Technologies Ref.: Soltani (Liberty) 3

Filmless Radiography: Digital Detectors Array Matrix detector PE1620 (www.perkinelmer.com) Energy range 20 kv 15 MV Szintillator Gd 2 O 2 S:Tb Pixel number 2048 x 2048 Pixel size 0,2 mm A/D-resolution 16 Bits Interface Ethernet Frame rate 3,75 fps Line detector-modul X-LSC 2.3 (www.deetee.com) Energy range 450 kvp 9 MeV Szintilator CdWO 4 Channels/Modul 64 Pixel size 2,3 mm x 7 mm Absorption length 30 mm A/D-resolution 18 Bits Interface Ethernet Frame time (continous) 1,0 ms 128 ms 4

Fast Test of Heat Exchangers with Tiled DDA

Testing of Heat Exchanger Welds RT-testing of tube-to-tube-sheet joints Gammat B3 Possible tube dimensions: 12*1.5 up to 76.1*4 (diameter*thickness) Materials: carbon and stainless steel, Ni-alloys, Zr, (Ti, Ta) Joint design shall be considered Ir 192, Radiator: 1 x 0.5 mm² WLE/AD - Plant Inspection, Welding Engineering; PVT Meeting Freeport 2004 14

Testing of Heat Exchanger Welds with a specialised Digital Detector Array Through the Detector Practice test X-ray tube Warrikhoff MCTS 130A-0,6 and CdTe-Detector Ajat DIC100TH Quelle: Alekseychuk, Zscherpel, Rost

Research-Project BASF/Ajat/BAM since 2006, First Results on Test Weld D4 film with 130 kv: 1 min (1mm Sn filter) X-Ray tube with DIC100TH detector 75 kv, 0,5 ma, 10s greater sensitivity smaller energy smaller exposure dose

Radiography on thick-walled components 9

Radiography of thick-walled components with Co-60 Detector: image plate Iron cast insert for the transport of fuel rods in Castors (skb.com) Source: Co-60 FDD: 390 mm Thickness: 135 mm 25.02.2016 Recent Development in Digital RT 10

Radiography of thick-walled components with Co-60 Film Agfa D7, IF+BF: 0,6 mm FDD Acitivity Exposure time 360 mm 3343,97 GBq 8 min. Exposure value 26751,76 GBq*min Image quality: SNR = 230:1 DDA PerkinElmer XRD1622, 200µm FDD Acitivity Exposure time 390 mm 3340,97 GBq 4 min. (60frames, 4sec) Exposure value 13363,88 GBq*min Image quality: SNR = 207 : 1 17.04.2015 Thema der Präsentation 11

On-site Inspection of an Elevated Subway Construction with an Ir-192 Gamma Source 17.04.2015 Thema der Präsentation 12

Subway construction - U2: Task Riveted steel truss girder viaduct of the elevated metro line U2 in Berlin- Kreuzberg. Start of operation: 1902, forced break in operation between 1961 und 1995 caused by cold war separation of Berlin. Verification of the structures safety against fatigue failure for the coming 30 years. 13

Subway construction - U2: Task Rivet 1: Crack in the gusset plate connection at the vertical strut Horizontal strut Vertical strut Iridium 192 @ 2220 GBq DDA: Vidisco (145 µm) SDD=80 cm; 16f @ 20s/f: 320 sec Exp.value = 11840 GBq*min Image is highpass-filtered (EnhanceDetails). Film: Agfa D7 Exp.value = 16576 GBq*min @ 2405 GBq, 414 sec 14

New Detector in Radiology: DDA Advantages direct process of radiation detection high sensitivity - shorter exposure time no dark room required digital images available evaluation through digital algorithm possible higher accuracy easy handling (size, weight) time integration on the detector Disadvantages limited spatial resolution different characteristic to the film Ref.: Beckmann, Onel, Ewert (Juni 2000)

Inspection of rail system Southern Region of London Hong Kong MTR and KCR Corporations Eurotunnel Controlled area < 1m System Se-75 and CR (image plate) with collimation tube on-site inspection 16

Conclusion Fan Beam Geometry reduction of the radiation beam smaller control zone Application: line camera with slit collimator in front Shorter Exposure Time Minimisation of the exposure of persons Application: Image Plates (up to 60%, limited resolution) Flat Panel Detector Mechanised Scanner-Principle no film handling --> Minimisation of the exposure of persons (e.g. Nuclear Power Plant) one-time setup of the manipulator on the test object for multiple repeated exposures 17