Industrial motor controller for brushed DC motors 24 VDC

Similar documents
Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 12 VDC

EC 45 flat with integrated electronics Document ID: en Operating Manual

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

Installation and Operating Instructions for Phase Demodulator Type _.2

SCA-SS (70V, 10A)

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Silencer Series Brushless Controllers

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

PU202 Level converter & encoder signal generator without potential separation

PHOENIX CONTACT

Installation and Operational Instructions for ROBA -switch Type 017._00.2

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

Manual SCA-SS V /02 page 1

Operating Manual MU2000K

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

PHOENIX CONTACT

MACX MCR-UI-UI-UP(-SP)(-NC)

Analog Servo Drive 20A20

Power Supplies 3. SDN-C Compact DIN Rail Series

External brake resistor AX2090-BW5x

maxon motor maxon motor control 1-Q-EC Amplifier DECS 50/5 Order number

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

Operating instructions Fail-safe delay timer AZS About this document. Content

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

Power supply CP-D 12/2.1

Valve amplifier for proportional pressure valves

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

maxon motor maxon motor control 4-Q-EC Servoamplifier DES 70/10 Order number

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

RSMFX-2R MULTIFUNCTIONAL

Power supply CP-D 24/4.2 Primary switch mode power supply

MDC V, 2A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device


MINI-PS AC/24DC/1.3

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

Analog Servo Drive 30A8

Booster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6

Switching power supplies CP range, Linear power supplies CP-L range. Content

PD2. Manual. Plug & Drive PD2 -1-

Analog amplifier RA. RE Edition: Replaces:

Power supply CP-E 24/2.5

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

VARAN Stepper Module VST 012

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Smart Power Relay E I...

Power supply CP-D 24/1.3

Power supply CP-E 24/20.0

Digital amplifier for proportional valves PEM XD

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

MINI MCR-SL-UI-f(-SP)

Thyristor power controller B DI1002 V1.0 Manual/Operating instructions

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Variable Speed Brushed DC Motor Drive

AxCent Servo Drive A25A100

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

VariTrans P V. Safe and Sound.

FREQUENCY-CONVERTER MFR 600A / 1500A Version 2

Operating Instructions PROFITEST H+E TECH. Diagnostics Unit for Electric Charging Stations (Type 2 Connector Socket and Plug) /3.

Thermocouple - Transducer

MINI MCR-SL-UI-I-LP-NC

DSAE - AAA - B - C - DD - E AAA

Power supply CP-T 48/20.0 Primary switch mode power supply

SKS B2 120 GD 69/11 - MA PB

CONTENTS XV300K GB r doc XV300K 2/13

Analog Servo Drive 30A20AC

Power supply CP-T 48/5.0 Primary switch mode power supply

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Tangential Fans - Basic principles. Expertise, performance, innovation

Technical data. General specifications. Measurement range min max. 360

Instruction manual for STA 1 sectional door operator

Antenna Splitter ASA 1. Instruction manual

PHOENIX CONTACT - 09/2009

Technical Documentation

Installation and user s guide H A. NCi-5 non-contact tool setting interface

Power supply CP-T 24/20.0 Primary switch mode power supply

Analog Servo Drive 30A8

AC/DC sensitive residual current monitoring module RCMB121-

CCS Inc. (8) DIN Rail Bracket. 2-M3(inside 3mm max.) for Fixation

Motion Controller 2-Quadrant PWM for Brushless DC-Servomotors

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

EFC 3600 Frequency converter for higher energy efficiency and improved process control

RM3-IV-LPI. 4-20mA Loop Powered Signal Isolators ma & DC Volts Inputs Operation and Instruction Manual

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

User and Safety Manual ProLine P224xx P1

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

Instruction manual for STA 1 sectional door operator

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

BC145 SIGNAL ISOLATOR BOARD

Power supply CP-E 24/0.75

Phase sequence and phase failure monitor

Transcription:

Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 5 A Control with the following functions: - reversal of direction of rotation - open-loop speed control (external) - adjustable start ramp (external) - overload shut-down - short circuit detection - dynamic brake To snap onto the DIN rail EN 50022 Unit width: 17,5 mm Type M2-MR-5-30 Article number 06.34.001 Operating data Nominal voltage Unom 24,0 VDC Supply voltage VCC 18.. 30 VDC Control inputs UDI 24,0 VDC Analog input UAI 0.. 10 VDC Quiescent current typ I0 50 ma Technical data: load circuit Max. current / continuous load current typ Imax/Icon 15 / 5 A Short circuit current detection typ ISC 80 A Shut-down time after short circuit typ tsc 100 µs PWM frequency FS 15,6 khz Duty cycle 5.. 100 % Power stage driver MOS-FET Other data Dimensions 17,5 x 70,4 x 85,0 mm Connectors screw terminal, pitch 5 mm cross section 0,2 2,5 mm² Permissible ambient temperature Tamb -20.. +50 C Temperature monitoring / overvoltage protection yes / yes Status indication: dynamic brake / Left / Right LED1 yellow / LED2 green / LED3 green Dynamic brake (Armature short circuit) can be switched off Start ramp 0,05.. 4 s 09.11.2017 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH Strübelweg 14 D-73553 Alfdorf, Germany Phone: +49 7172 93711 0 info@kaleja.com

Other data Installation position / Assembly any / top-hat rail EN 50022 Installation place, typical Switch cabinet Storage temperature -30 bis +85 C Permissible humidity to 95 %, non-condensing Weight 0,075 kg Start up delay 2s Hazardous substance norm RoHS2 EMC interference immunity EN 61326-1:2013-01 EN 61000-6-2:2005-08 EMC emitted interference, operation in industrial DC network EN 61326-1:2013-01, Class A EMC emitted interference, operation with power supply EN 61326-1:2013-01, Class B supply unit / power unit KDR 120-24, Ott GmbH & Co. KG or comparable Technical data: digital input High Signal typ U > 10 V Low Signal typ U < 4 V Impedance typ RDI 15 kω Technical data: analog input Voltage range 0.. 10 V VCC tolerant yes Impedance typ RAI 98,5 kω Flammability Housing, terminal, printed circuit board UL94V-0 Starting behavior The module M2-MR-5-30 is ready to use after the start up delay. After the module is powered up the startup delay time starts to run. Description The module M2-MR-5-30 is a two-quadrant motor control with open loop speed control for DC motors, for use in an industrial environment. It guarantees the switching on and off and the controlled drive of motors. Through two analog inputs it is possible to set the start ramp gradient and the speed of rotation. The motor can be stopped with and without dynamic braking. 09.11.2017 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH 2017 Page 2/6

Typical application: Standard Typical application: PLC 09.11.2017 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH 2017 Page 3/6

Terminal diagram State table 4 5 6 Analog input 1 10V Auxiliary voltage output NC rotational speed 0..100 % +10V/approx. 50mA (PTC fuse) 1 2 3 Digital input Digital input GND for external potentiometer run left run right (p- switch) (p-switch) 7 8 9 Motor winding B Motor winding A Digital input disable dynamic brake (p-switch) 10 11 12 GND supply +24V supply voltage, analog input 0.. 10V direction left (1) direction right (2) disable dyn. braking (9) Motor A (7) Start ramp 50 4000ms Motor B (8) Funktion 0 1 X VCC GND run right 1 0 X GND VCC run left 1 1 X GND GND dyn. braking 0 0 0 GND GND dyn. braking 0 0 1 open open off Function: Speed setting Via the analog input at terminal (5) it is possible to set the PWM duty cycle that is to be issued to the motor. Within a range from 1 V to 10 V, the voltage is applied as a 0 100 % output. With a loading of the motor, the speed reduces. voltage (5) Rotational speed / PWM > 10V 100% 1 10V Linear 5 100% < 1V off open off Function: dynamic brake The function dynamic braking is activated as standard. The function is deactivated by applying a High Signal at terminal (9). If dynamic braking is active, the motor winding is switched to GND at both terminals when switched off. The motor is stopped with armature short circuit braking. If dynamic braking is not active, the motor spins with no braking. Function: Start ramp Via the analog input at terminal (12) it is possible to set the gradient of the start ramp resp. the time of the start ramp until 100 % PWM is reached. Example: If the speed specification is set to 50 % PWM and the start ramp is set to 4000 ms, the time until 50 % PWM is: 2000 ms. voltage (12) Start ramp time to 100% 0 10V linear 50 4000ms open 50ms Function: Overload / short circuit detection With an overload or short circuit, the motor switches off without dynamic braking. The motor can be restarted by means of a reset and fresh setting of a direction of rotation. 09.11.2017 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH 2017 Page 4/6

Device status * 1 Display elements * 1 The module status is displayed via the LEDs on the module front plate. LED1 LED2/LED3 meaning yellow green On Off Module is ready break is active Off Off Module is ready break is deactivated Off On Motor is running rotation direction is indicated over LED flashing On Module error 1 (see table) flashing flashing Internal Error Module errors are displayed as flashing sequences. The end of the sequence is indicated by a pause of 1 second. The number of flashes indicates the error number. LED2/LED3 indicates in which direction of rotation the error occurs. To reset the error the direction Input must be set low and the internal reset conditions must be fulfilled. Module error 1 1 overcurrent 2 Over-temperature 3 short circuit detected 4 overvoltage 5 overload 6 Under-temperature 7 Low supply voltage * 1 available as of Lot 14/17 Dimensional drawing A = 70,4 mm; B = 17,5 mm; C = 85 mm 09.11.2017 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH 2017 Page 5/6

Safety notes Maximum operational data The maximum operating data may not be exceeded. Installation The installation and start-up must be performed by specialist personnel exclusively. All affected components must be disconnected from the mains. Start-up For the first start-up, the motor should be operated without load. Risk of death Do not touch live parts after switching on! The assembly must be operated exclusively on safety extra-low voltage. With operation on extra-low voltage (e.g. via autotransformer), death or injury can occur. Fire protection The assembly must be installed in a switch cabinet, which is suitable as a fire protection enclosure. The assembly must be safeguarded with a pre-fuse aligned with the nominal data. Field of application The assembly may only be used as intended. Other components must be checked for their approvals and regulations. Safety devices An additional safety device must be used to bring the system into a safe state in case of a cable break, incorrect operation, failure of the control/controller unit. EMC / EMI The wiring must be done according to EMC / EMI standards. If necessary, shielded cables and EMC suppressors must be used for the connected consumer. For operation in a public low-voltage distribution network, the module must be supplied with an approved AC adapter. If the module is supplied with an AC adapter, other equipment, operated on the same power supply, must be suitable for use in industrial environments. Repairs Repairs must be performed by authorised persons exclusively. With unauthorised opening, the warranty cover is voided and this may also result in danger for the user and for the system. Maintenance The assembly is wear-free by design. For modules with cooling openings free air circulation must be checked at the cooling openings or on the housing at regular intervals. If necessary, the cooling holes / the housing must be cleaned. Good ventilation must be ensured. contact details ready-to-use motor control solutions electronics design & manufacturing KALEJA GmbH Strübelweg 14 73553 Alfdorf, Germany Phone: +49 7172 93711 0 Fax: +49 7172 93711 90 E-Mail: info@kaleja.com www.kaleja.com 09.11.2017 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH 2017 Page 6/6