ACD-14 FX ACD-14 TRMS FX

Similar documents
INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Category III 600 Volts ac and dc.

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

USER'S MANUAL. ACD-16 Pro ACD-16 TRMS Pro ACD-40PQ

ACD-15 Pro & ACD-15 TRMS Pro Clamp-on Multimeter Series

200Amp AC Clamp Meter + NCV Model MA250

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

PM55A. Automatic Precision Pocket Meter. English. Users Manual. PN July Amprobe Test Tools. All rights reserved.

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

BM22s, BM25s, BM25a & BM27s USER'S MANUAL

Circuit Breaker Finder

User s Guide. 400A AC/DC Clamp Meter. Model MA220

CT238A. AC/DC Current Probe. User Manual. For detailed specifications and ordering info go to

AM-250. Digital Multimeter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

DM-45 Digital Multimeter

AT Advanced Wire Tracer. Users Manual

400Amp True RMS AC/DC Clamp Meter Model EX613

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

USER'S MANUAL DMR-6700

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

For detailed specifications and ordering info go to

AMP-25 AMP-25-EUR. Mini-Clamp TRMS AC / AMP-25. ZERO 2 Sec

Electrical Multimeter

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

ACD-3300 IND ACDC-3400 IND

400Amp True RMS AC Clamp Meter + NCV

AC68C. Users Manual. True RMS AC/DC Clamp Multimeter. PN July Amprobe Test Tools. All rights reserved.

AC/DC CLAMP METER USER S MANUAL

USER'S MANUAL BM151 BM152 BM155. PowerClamp TM Series

User Guide. Digital AC/DC Clamp Meter Model 38394

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

User s Guide. Digital AC/DC Clamp Meter Model 38394

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Autoranging Multimeter Extech EX503

AM-520 AM-530. Users Manual. HVAC Multimeter. True-rms Electrical Contractor Multimeter

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

312, 316, 318. Clamp Meter. Users Manual

USER'S MANUAL. BM315 BM319 Automotive Multimeter

NOTE: Fully read and understand this manual before using this Digital Multimeter.

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

374/375/376 Clamp Meter

ET-3888 True RMS Clamp Meter. User Manual

DM-46 Instruction Manual

12B/18 MultiMeter Instruction Sheet

KMD-S04 Multímetro de bolsillo

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

374/375/376 Clamp Meter

User s Guide. Model MA A AC Mini Clamp-on Meter

USER'S MANUAL TIS 859, TIS 849 & TIS 839 Voltage Tester

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

DM-46 Instruction Manual

ACD-45PQ. 600A Power Quality Clamp. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

UT207A/208A/209A Operating Manual. Table of Contents

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

AM-540 AM-550. AM-540-EUR AM-550-EUR Digital Multimeter. Users Manual. Advanced HVAC Multimeter. Industrial Multimeter

netzerotools.com 374/375/376 Users Manual Clamp Meter

AM-270. Users Manual. Industrial Multimeter with Bar-graph Display. For detailed specifications and ordering info go to

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

DVM1190 DIGITAL MULTIMETER

34XR Digital Multimeter. Users Manual

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

USER'S MANUAL. BM151s, BM152s, BM155s, & BM351s PowerClamp TM Series

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Supplement. Title: 33XR-A Users Supplement Issue: 1 Part Number: Issue Date: 9/06 Print Date: July 2006 Page Count: 1 Revision/Date:

AMM-1022 Digital Multimeter USER`S MANUAL

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Pen Multimeter. Model

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

USER'S MANUAL AM-120 TRMS AM-130 TRMS AM-150 TRMS

79/26 Series III Multimeter

USER'S MANUAL DMR-4350

15B & 17B. Multimeters. Users Manual

DMM8900 SERIES USERS MANUAL

User Manual. All rights reserved. Specifications are subject to change without notice.

Instruction Manual IDM 66RT Digital Multimeter

15B & 17B. Users Manual. Multimeters

600A Clamp Meters w/tightsight Display

Model UT10A: OPERATING MANUAL Table of Contents (1)

User's Manual. Clamp-on Power Datalogger. Model

Models 110, 111 & 112

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

Supplement. Title: 30XR-A Users Supplement Issue: 1 Part Number: Issue Date: 9/06 Print Date: July 2006 Page Count: 1 Revision/Date:

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

374 FC/375 FC/376 FC Clamp Meter

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

User s Guide. MultiMaster Digital MultiMeter Series With PC Interface. Models: MM560A MM570A

Transcription:

ACD-14 FX ACD-14 TRMS FX User Manual Bedienungshandbuch Mode d emploi Manuale d Uso Manual de uso Bruksanvisning

ACD-14 FX ACD-14 TRMS FX Owner s Manual

Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Repair All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe Test Tools. In-Warranty Repairs and Replacement All Countries Please read the warranty statement and check your battery before requesting repair. During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product. Please check the Where to Buy section on www.amprobe.com for a list of distributors near you. Additionally, in the United States and Canada In-Warranty repair and replacement units can also be sent to a Amprobe Test Tools Service Center (see address below). Non-Warranty Repairs and Replacement US and Canada Non-warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center. Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates. In USA In Canada Amprobe Test Tools Amprobe Test Tools Everett, WA 98203 Mississauga, ON L4Z 1X9 Tel: 877-AMPROBE (267-7623) Tel: 905-890-7600 Non-Warranty Repairs and Replacement Europe European non-warranty units can be replaced by your Amprobe Test Tools distributor for a nominal charge. Please check the Where to Buy section on www.amprobe.com for a list of distributors near you. European Correspondence Address* Amprobe Test Tools Europe P.O. Box 1186 5602 BD Eindhoven The Netherlands *(Correspondence only no repair or replacement available from this address. European customers please contact your distributor.) 1

Contents: ACD-14 FX ACD-14 TRMS FX Safety Regulations...3 Product Description...5 Operation...6 Maintenance...12 Specifications...14 2

Congratulations! Your new instrument has been crafted according to quality standards and contains quality components and workmanship. It has been inspected for proper operation of all of its functions and tested by qualified factory technicians according to the long-established standards of Amprobe. Safety Regulations This manual contains information and warnings that must be followed for operating the instrument safely and maintaining the instrument in a safe operating condition. If the instrument is used in a manner not specified by the manufacturer, the protection provided by the instrument may be impaired. OVERVOLTAGE CATEGORY III: Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. Note Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation. TERMS IN THIS MANUAL WARNING: Identifies conditions and actions that could result in serious injury or even death to the user. CAUTION: Identifies conditions and actions that could cause damage or malfunction in the instrument. 3

WARNING: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. The meter is intended only for indoor use. To avoid electrical shock hazard, observe the proper safety precautions when working with voltages above 60 VDC or 30 VAC rms. These voltage levels pose a potential shock hazard to the user. Inspect test leads, connectors, and probes for damaged insulation or exposed metal before using the instrument. If any defects are found, replace them immediately. Do not touch test lead tips or the circuit being tested while power is applied to the circuit being measured. To avoid accidental short circuit of bare (un-insulated) hazardous live conductors or bus bars, switch them off before insertion and removal of the current clamp jaws. Contact with the conductor could result in electric shock. Keep your hands/fingers behind the hand/finger barriers that indicate the limits of safe access of the meter and the test leads during measurement. CAUTION: Disconnect the test leads from the test points before changing meter functions. INTERNATIONAL ELECTRICAL SYMBOLS Caution! Refer to the explanation in this Manual Caution! Risk of electric shock Earth (Ground) Double Insulation or Reinforced insulation Fuse AC--Alternating Current DC--Direct Current Conformity symbol, the instrument complies with the valid directives. It complies with the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) with their valid standards. Underwriters Laboratories Inc. [Note: Canadian and US.] 4

Product Description Note: Please refer to Specification Section for function details. 1) Clamp Jaw for AC current magnetic field pick up 2) Hand/Finger Barrier to indicate the limits of safe access of the meter during measurement 3) Power ON/OFF buttons for ACA current function and MAX/Hold features 4) Push-button for frequency selection 5) Input Jack for all functions EXCEPT clamp-on ACA current function 6) Common (Ground reference) Input Jack for all functions EXCEPT clamp-on ACA current function 7) Slide-switch Selector to turn the lower display ON/OFF and to Select functions 8) Lower Display: for Input Jack functions 3-3/4 digits 4000 counts LCD 9) Upper Display: for ACA current Clamp-on 3-3/4 digits 4000 counts LCD 10) Jaw trigger for opening the ACA current clamp jaw 5

Operation DC Voltage, AC Voltage, Hz Frequency functions Inputs are made through the test lead terminals. Move the slide-switch to the V position. The unit defaults at DC voltage. Press SELECT button momentarily to select AC voltage. To activate the Hz Frequency function, press the Hz button momentarily. Note: 400.0mV range is designed with 1000MΩ high input impedance for least current drain in measuring small signals, and can cope better with most commercially available voltage output transducers/adapters. The non-zero display reading is normal when the meter inputs are open circuit, which will not affect actual measurement accuracy. The meter will show close to zero reading when the inputs are shorted. Open input is actually a floating condition, which is not a zero-volt-input condition. 6

Note: Hz input sensitivity varies automatically with function range selected while activating the Hz function. Lowest range has the highest sensitivity, and the highest range has the lowest sensitivity. Activating the Hz function WHILE measuring the specific function signal (auto ranging) can automatically select the best sensitivity range to avoid electrical noise that may cause unstable Hz reading. However, if the Hz reading shows zero due to insufficient sensitivity, activate the Hz function BEFORE measuring the specific function signal. The meter is then in the lowest range and can select the highest sensitivity range. Ω Resistance, and Continuity functions Inputs are made through the test leads terminals. Move the slide-switch to the Ω position. The unit defaults at Ω. Press SELECT button momentarily to select Continuity function, which is convenient for checking wiring connections and operation of switches. A continuous beep tone indicates a complete wire circuit. 7

Diode test function Inputs are made through the test lead terminals. Move the slide-switch to the Ω position. The unit defaults at Ω. Press SELECT button momentarily 2 times to select Diode test function. Normal forward voltage drop (forward biased) for a good silicon diode is between 0.400V to 0.900V. A reading higher than that indicates a leaky diode (defective). A zero reading indicates a shorted diode (defective). An OL indicates an open diode (defective). Reverse the test leads connections (reverse biased) across the diode. The digital display shows OL if the diode is good. Any other readings indicate the diode is resistive or shorted (defective). Capacitance function Inputs are made through the test leads terminals. Move the slide-switch to the Ω position. The unit defaults at Ω. Press SELECT button momentarily 3 times to select Capacitance function. CAUTION Measuring Resistance, Continuity, Diode or Capacitance function on a live circuit will produce false results and may damage the instrument. In many cases the suspected component must be disconnected from the circuit to obtain an accurate measurement reading. 8

ACA Current clamp-on function Inputs are made through the clamp on jaws for non-invasive ACA current measurements. Press the OFF push button momentarily to power on and off the separate ACA function (upper) display. The MAX HOLD push button can also be used to power on this function. This twin ACA function display can be used simultaneously with voltage measurements or any of the other slide-switch functions (lower display) or it can be used alone. CAUTION Clamp the jaws around only one single conductor of a circuit for load current measurement. Enclosing more than one conductor of a circuit will result in differential current (like identifying leakage current) measurement. 9

Make sure the jaws are completely closed, or else it will introduce measurement errors. Strong Electro-magnetic field environments such as high-current transformers, motors and conductors may affect measurement accuracy. Temperature function Insert the banana plug type-k temperature bead probe (TPK-59), observing the proper + - polarities. Move the slide-switch to the F/ C position. The unit defaults at degree C (Celsius). Press SELECT button momentarily to select degree F (Fahrenheit). µa Current function Inputs are made through the test leads terminals. Move the slide-switch to the µa position. The unit defaults at DC. Press SELECT button momentarily to select AC. You can select the Hz function by momentarily pressing the Hz button. 10

Application notes: The DC µa function is designed especially for HVAC/R flame sensor applications. The 0.1µA resolution is useful for identifying the minute current changes in flame detector applications. Flame signal current check should indicate steady flame signal of at least 2µA for a rectification type, 1.5µA for an ultraviolet type, or 8µA for self-checking systems. If a flame signal current with inadequate strength or fluctuation beyond 10%, check the following to avoid the risk of unwanted flame relay dropout: For gas or oil flames (Minipeeper): Low supply voltage Detector location Defective detector wiring Dirty viewing windows Faulty Minipeeper For oil flames (Photocell): Detector location & wiring Smoky flame or poorly adjusted air shutter Faulty Photocell Temperature over 165 F (74 C) at photocell For gas flames (Flame Rod): Ignition interference (A flame signal current difference with the ignition both on and off greater than 0.5µA indicates the presence of ignition interference) Insufficient ground (must be at least 4 times the detector area) Flame lifting off burner head (ground), or not continuously in contact with the flame rod Temperature in excess of 600 F (316 C) at the flame electrode insulator, causing short to ground. HOLD The hold feature freezes the upper ACA display for later viewing. Press the HOLD button momentarily to activate or exit this feature. MAX The Max feature compares and displays the measured maximum value (on the upper ACA display) as fast as 25ms with auto-ranging capability. Press the MAX button for 1 second or more to activate or exit this feature. 11

Auto-ranging When there is more than one measuring range under a selected meter function, the LED annunciator a turns on in the upper left corner. The meter will automatically switch to the best resolution range when making measurements. No manual ranging selection is required. Auto Power Off (APO) When the meter is on, the Auto Power Off (APO) feature will switch the meter into a sleep mode automatically to extend battery life after approximately 30 minutes of the last front panel activity. To wake up the meter from APO, press the buttons momentarily or move the slide-switch to the OFF position and then back on again. Always set the slide-switch to the OFF position manually when the meter is not in use. Maintenance WARNING To avoid electrical shock, disconnect the meter from any circuit, remove the test leads from the input jacks and turn OFF the meter BEFORE opening the case. Do NOT operate with open case. Trouble Shooting If the instrument fails to operate, first check the batteries and test leads etc., and replace as necessary. Double check the operating procedures as described in this User s Manual. If the instrument voltage-resistance input terminal is subjected to a high voltage transient (e.g. lightning or switching surge) by accident or abnormal conditions of operation, the series fusible resistors will be blown (become high impedance) like fuses to protect the user and the instrument. Most measuring functions through this terminal will then be an open circuit. A qualified technician should then replace the series fusible resistors and the spark gaps. Refer to the LIMITED WARRANTY section for obtaining warranty or repair service. Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. If the meter is not to be used for periods of longer than 60 days, remove the batteries and store them separately. 12

Battery replacement The meter uses 2 standard 3V alkaline button batteries (ANSI/NEDA-5004LC, IEC-CR2030). The lower battery is used for the slide-switch functions, and the upper battery is used for the upper display ACA function separately. Low Battery Indication: When the battery voltage drops below approx. 2.4V, a battery symbol will appear in the upper right corner of the LCD display, indicating that the battery needs replacing. To replace the batteries, loosen the two screws from the case bottom and remove the bottom case. Slide the battery out the side of the holder (see example below) and replace with a new battery (observe polarity). Replace the bottom case. Note: Take care to insure that the two (2) springs (located near the lower battery) line up with the speaker in the rear cover. Re-fasten the screws. 13

Specifications General Specifications Display: 3-3/4 digits 4000 counts, dual LCD displays Update Rate: 3 per second nominal Polarity: Automatic Low Battery Indication: Below approx. 2.4V Operating Temperature: 0 C to 40 C (32 F to 104 F) Relative Humidity: Maximum relative humidity 80% for temperatures up to 31 C (88 F) decreasing linearly to 50% relative humidity at 40 C (104 F) Altitude: Operating below 2000m (6,562 ft) Storage Temperature: -20 C to 60 C (-4 F to 140 F), < 80% R.H. (with battery removed) Temperature Coefficient: nominal 0.15 x (specified accuracy)/0 C - 18 C or 28 C - 40 C ( F @ 32 F - 64 F or 82 F - 104 F, or otherwise specified Sensing: Average sensing for ACD-14 FX; True RMS for ACD-14 TRMS FX Power Supply: Two 3V alkaline button batteries (ANSI/NEDA-5004LC, IEC-CR2032). Battery Life: 95 hours approx. (in DCV mode) Power Consumption: 2.5 ma typical for ACD-14 FX; 2.9mA typical for ACD-14 TRMS FX Low Battery Indication: Below approx. 2.4V (battery symbol appears in upper right) Auto Power Off: After being idle for 30 minutes APO Consumption: ACD-14 FX: 0.8µA typical except 25µA typical for temperature function ACD-14 TRMS FX: 10µA typical except 25µA typical for temperature function Dimension: L 190mm X W 63mm X H 32mm (L 7.48 X W 2.48 X H 1.25 ) Weight: 204 g (0.450 Lb) approx. Jaw opening & Conductor diameter: 26mm (1.02 ) max Safety: Category III 600 Volts AC & DC CE Approved UL Listed Transient protection: 6.5kV (1.2/50µs surge) for all models Pollution degree: 2 Overload Protections: ACA Clamp-on jaws: AC 400A RMS continuous + & COM terminals (all functions): 600VDC/VAC RMS 14

Standard Accessories: Test leads (pair), banana plug style, bead Type-K Thermocouple, batteries, user s manual, & soft carrying case. Replacement Part Numbers: Test Leads (pair): MTL-90B, Bead Type-K Thermocouple: TPK-59, Carrying Case: SV-U Electrical Specifications Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 73 F ± 9 F (23 C ± 5 C) & less than 75% R.H. True RMS Model ACD-14 TRMS FX ACV, AcµA & ACA clamp-on accuracies are specified from 5% to 100% of range or otherwise specified. Maximum Crest Factor are < 1.96 at full scale & < 3.92 at half scale, and with frequency spectrums, besides fundamentals, fall within the meter specified AC bandwidth for non-sinusoidal waveforms. DC Voltage RANGE Accuracy 400.0 mv 0.3% + 4d 4.000V, 40.00V, 400.0V 600V 0.5% + 3d 1.0% + 4d NMRR: >50dB @ 50/60Hz CMRR: >120dB @ DC, 50/60Hz, Rs=1kΩ Input Impedance: 10MΩ, 30pF nominal (1000MΩ for 400.0mV range) Max Hold (where applicable) Specified accuracy ± 50 digits for changes > 25ms in duration Type-K Temperature RANGE Accuracy* -20 C TO 300 C 2% + 3 C -4 F TO 572 F 2% + 6 F *Type-K thermocouple range & accuracy not included AC Voltage RANGE Accuracy 1) 50Hz -- 500Hz 4.000V, 40.00V, 400.0V 600V 1.5% + 5d 2.0% + 5d CMRR: >60dB @ DC to 60Hz, Rs=1kΩ Input Impedance: 10MΩ, 30pF nominal ACA Current (Clamp-on) RANGE 50Hz / 60Hz Accuracy 40.00A 1.9% + 8d 400.0A 1.9% + 8d* 600A** unspecified *Accuracy specified to 350A continuous, and 400A for 60-second max with 5 minutes cool down interval **Added range to indicate instantaneous over-range current values TRMS model ACD-14 TRMS FX accuracy is specified from 10% to 100% of range. 15

DC µa RANGE Accuracy Burden Voltage 400.0µA 1.5% + 4d 2.8mV/µA 2000µA 1.2% + 3d 2.8mV/µA AC µa RANGE 50Hz -- 500Hz Accuracy Burden Voltage 400.0µA 2.0% + 5d 2.8mV/µA Capacitance RANGE* 500.0nF, 5.000µF, 50.00µF, 500.0µF, 3000µF Accuracy** 3.5%*** + 6d *Additional 50.00nF range accuracy is not specified **Accuracies with film capacitor or better ***Specified with battery voltage above 2.8V (approximately half full battery). Accuracy decreases gradually to 12% at low battery warning voltage of approximately 2.4V 2000µA 1.5% + 5d 2.8mV/µA Ohms RANGE Accuracy 400.0Ω 0.8% + 6d 4.000kΩ, 40.00kΩ, 400.0kΩ 4.000MΩ 40.00MΩ 0.6% + 4d 1.0% + 4d 2.0% + 4d Open Circuit Voltage: 0.4VDC typical Audible Continuity Tester Audible threshold: between 10Ω and 120Ω. Diode Tester Open Circuit Voltage Test Current (Typical) < 1.6 VDC 0.25mA Hz Frequency Function Sensitivity (Sine RMS) Range 400.0mV 300mV 10Hz -- 2kHz 4.000V 4V 5Hz -- 40kHz 40.00V 28V 5Hz -- 100kHz 400.0V 100V 5Hz -- 100kHz 600V 500V 5Hz -- 5kHz 400.0µA 500µA 10Hz -- 30kHz 2000µA 500µA 10Hz -- 30kHz Display counts: 5000 Best resolution: 0.001Hz Accuracy: 0.5%+4d 16

17