ARDUINO BASED POWER FACTOR CORRECTION

Similar documents
Simulation & Hardware Implementation of APFC Meter to Boost Up Power Factor Maintain by Industry.

Power Factor Correction of Inductive Loads using PLC

Power Factor Improvement Using Thyristor Switched Capacitor Using Microcontroller Kacholiya Saurabh 1, Phapale Sudhir 2, Satpute Yuvraj 3, Kale.S.

A Single Phase Power Factor Correction Using Programmable Interface Circuit

PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS.

Power Factor Improvement Using Static VAR Compensator

ELG 4125: ELECTRICAL POWER TRANSMISSION AND DISTRIBUTION: TUTORIAL 1: - BY:

Power Factor Compensation Using PIC

POWER FACTOR CORRECTION OF MACHINE LABORATORY AND CNC MACHINE BY USING IPFC CONTROLLER

AUTOMATIC POWER FACTOR CORRECTION AND MONITORING BY USING PIC MICROCONTROLLER

Automatic Power Factor Correction by Using Synchronous Condenser with Continuous Monitoring.

IMPROVING POWER QUALITY AND ENHANCING THE LIFE OF POWER EQUIPMENT, IN RAILWAY TSSs

Thyristorised Real Time Power Factor Correction (TRTPFC)

Monitoring And Control Over Power Factor By Using Pic Micro-Controller

Design and Implementation of Economical Power Factor Transducer

SRI VIDYA COLLEGE OF ENGG AND TECH

Digital Testing Kit for Three Phase Distribution Transformer

International Journal of Advance Engineering and Research Development AUTOMATIC POWER FACTOR CONTROL USING ARDUINO UNO

POWER FACTOR CORRECTION USING BOOST CONVERTER

DSP-BASED CURRENT SHARING OF AVERAGE CURRENT CONTROLLED TWO-CELL INTERLEAVED BOOST POWER FACTOR CORRECTION CONVERTER

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 08, 2015 ISSN (online):

Thyristorised Automatic Power Factor

Welcome to the rd. Annual Northern Ohio. 3 rd Energy Management Conference September 30, 2008

Design and Implementation of a New PWM Based Active Impedance Power Factor Correction (AIPFC)

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

Power Factor Correction in Digital World. Abstract. 1 Introduction. 3 Advantages of Digital PFC over traditional Analog PFC.

A Thyristor Controlled Three Winding Transformer as a Static Var Compensator

HARMONICS CAUSES AND EFFECTS

PERFORMANCE ANALYSIS OF MICROCONTROLLER BASED ELECTRONIC LOAD CONTROLLER

Introduction: TAS PowerTek Ltd. MAVROS

Prototype design of power factor correction circuit for transmission lines using Thyristor switched capacitor scheme

A Review on Simulation and Implementation of Thyristor controlled reactor and Shunt Hybrid Power Filter

SHUNT ACTIVE POWER FILTER

DEVELOPMENT OF A MICROCONTROLLER-BASED POWER FACTORY CORRECTOR

Experiment 45. Three-Phase Circuits. G 1. a. Using your Power Supply and AC Voltmeter connect the circuit shown OBJECTIVE

I. INTRODUCTION II. LITERATURE REVIEW

Design of a Microcontroller-Based Push-Pull Inverter with Automatic Voltage Regulator

CHAPTER 4 HARMONICS AND POWER FACTOR

World Academy of Science, Engineering and Technology International Journal of Electrical and Computer Engineering Vol:7, No:6, 2013

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

REACTIVE POWER COMPENSATION IN DISTRIBUTION SYSTEM

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Power Factor. Power Factor Correction.

IJOART. Abstract. Keywords:Capacitor banks,synchronous condenser,microcontroller,dc excitation,power factor. 1.Introduction:

Power Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives

Technical News. Part 2: Harmonics. The link between harmonics and power factor. Industrial Electrical and Automation Products, Systems and Solutions

CHAPTER 3 IMPROVEMENT OF LOAD POWER FACTOR USING FACTS CONTROLLERS

Modeling and Simulation of STATCOM

Analysis the Modeling and Control of Integrated STATCOM System to Improve Power System

Lab 4 Power Factor Correction

Power Quality Analysis in Power System with Non Linear Load

Feed Forward Control of Induction Motor using AC Voltage Regulator

POWER FACTOR IMPROVEMENT USING OPEN LOOP FEEDBACK STATIC VAR COMPENSATOR (SVC)

Enhancing Power Quality in Transmission System Using Fc-Tcr

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Sizing Generators for Leading Power Factor

Generator Advanced Concepts

Chapter 7. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Dynamic Harmonic Mitigation and Power Factor Correction

Electrical Motor Power Measurement & Analysis

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Active Harmonic Filter (AF3)

PFC Lite. How it works OMNIVERTER. OMNIVERTER November 14, 2015 Slide 1

Design and Implementation of Automatic Microcontroller- Based Controlling of Single Phase Power Factor Using Capacitor Banks with Load Monitoring

3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.

A NEW SINGLE STAGE THREE LEVEL ISOLATED PFC CONVERTER FOR LOW POWER APPLICATIONS

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Chapter L Power factor correction and harmonic filtering

AC Power Instructor Notes

Design and Implementation of High Precision Automated Online Monitoring of Distribution Transformer (OMDT) Device

Maintaining Voltage-Current Phase Relationships in Power Quality Monitoring Systems

How Harmonics have led to 6 Power Factor Misconceptions

TOUCH SCREEN BASED SPEED CONTROL OF SINGLE PHASE INDUCTION MOTOR

Study on Reactive Automatic Compensation System Design

Study of Power Factor Correction in Single Phase AC-DC Converter

Influence of Switching Elements on Harmonics and Power Factor Improvement

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

GRADE 12 SEPTEMBER 2012 ELECTRICAL TECHNOLOGY

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

AGN 026 Harmonic Voltage Distortion

INTRODUCTION PROPOSED SOLUTION STEPS TAKEN. MATLAB Simulation

SINGLE PHASE STATIC REACTIVE POWER COMPENSATION WITH ADAPTIVE FUZZY-PID BY USING PLC

CHAPTER 6 BRIDGELESS PFC CUK CONVERTER FED PMBLDC MOTOR

Testing and Stabilizing Feedback Loops in Today s Power Supplies

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

An Investigation of Power Converters Fed BLDC Motor for Adjustable Speed

Power Factor Correction Input Circuit

AC VOLTAGE CONTROLLER (RMS VOLTAGE CONTROLLERS)

ECET Modern Power

Impact of Distributed Generation on Network Voltage Levels

Single Phase Bridgeless SEPIC Converter with High Power Factor

Power Factor Correction Using SCR and Microcontroller

Current Rebuilding Concept Applied to Boost CCM for PF Correction

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

Application Guidance Notes: Technical Information from Cummins Generator Technologies

Technical Report. Zero Reactive Power Passive Current Harmonic Filter (ZRPPCHF) (In House Case Study) Prepared by. Dr. V. R. Kanetkar.

Power Factor and Power Factor Correction

Power Quality Monitoring and Power Metering Tutorial

UNIT II MEASUREMENT OF POWER AND ENERGY PART-A

Economic Single-Phase to Three-Phase Converter for Low Power Motor Drives

Transcription:

ARDUINO BASED POWER FACTOR CORRECTION 1 SHOBHA R.MANE, 2 ASHWINI A.KOLEKAR, 3 MAITHILI M. MOLAJ, 4 SADHANA V.PATIL, 5 MAZHARHUSSAIN N. MESTRI 1,2,3,4,5 Electrical Department, Shivaji University, Kolhapur, Maharashtra, India. Vishveshwarya Technical Campus Faculty of Degree Engineering, Patgaon, Miraj, Sangli, Maharashtra, India. E-mail: 1 shobhamane77@gmail.com, 2 ashwinikolekar99@gmail.com, 3 maithilimmolaj@gmail.com 4 sadhanapatil2727@gmail.com Abstract- Power factor correction is a technique of counteracting the undesirable effects of electric loads that create a power factor that is less than one. Power factor correction may be applied either by an electric power utility to improve the stability and efficiency of system or by customer at the premises. This is required to ensure long term, effective and economic operation and utilization of electrical power. In present paper we present automatic power factor correction scheme based on Arduino platform and triac based capacitor switching. Keywords- TSC (Thyristor Switched Capacitor), Capacitor bank, Arduino platform, Triac, SVC (Static VAR Compensator). I. INTRODUCTION MOST loads in modern electrical distribution systems are inductive. Examples include motors, transformers, gaseous tube lighting ballasts and induction furnaces. Inductive loads consume two kinds of power viz. So, with the presence of inductive load, power consumption and hence electric bill increase for same amount of work done What is power factor? e. Such condition is recognized as lagging power factor. Most loads in modern electrical distribution systems are inductive. Examples include motors, transformers, gaseous tube lighting ballasts, and induction furnaces. Inductive loads require two kinds of power: Working power (kw) to perform the actual work of creating heat, light, motion, machine output, and so on. Reactive power (kvar) to sustain the magnetic field Working power consumes watts and can be read on a wattmeter. It is measured in kilowatts (kw). Reactive power doesn t perform useful work, but at times is required for proper functioning of system and circulates between the generator and the load. Reactive power is measured in kilovolt-amperesreactive (kvar). Working power and reactive power together make up apparent power. Apparent power is measured in kilovolt-amperes (kva). Thus the magnitude of reactive power consumed in load is understood as cosine of angle between apparent power and true power. Power factor = cos(ø) Figure 1: Power triangle Our goal is to design system that would allow for PFC in both systems viz, single and three phases. Hence we decided to go with capacitor bank method. In this regard, there is design, fabrication and testing of microcontroller based Static VAR Compensator (SVC) consisting of Thyristor Controlled reactor (TCR) and Thyristor Switched Capacitor (TSC) has been done in a paper.[1] To reduce harmonics introduced because of relay switching the author has used thyristor based switching of capacitor bank. Further PIC microcontroller is used which according to us unnecessarily complicates system programming.[2] It describes the design and development of a threephase power factor correction using PSoC (Programmable System on Chip) micro-controlling chip. The scheme used here is to measure the angle between the voltage of Y and B phase and current of R phase, this gives value of sin(ø) relation. Also from the voltage of YB phase and current of R phase reactive and active power in KVAR and KWA of the system are calculated. From these parameters current power factor found. Here we see that same work can be obtained from cheap and easy to used Arduino platform. The project work describes the design and development of a power factor corrector using PIC microcontroller chip. Measuring of power factor from load is achieved by using PIC Microcontroller-based developed algorithm to determine and trigger sufficient switching of capacitors in order to compensate demand of excessive reactive power locally, thus bringing power factor near to unity. In conclusion microcontroller based automatic power factor correction using capacitor switched method seems a very flexible solution. But unlike above mentioned attempts we have avoided using PIC or similar microcontroller to avoid difficulty in 4

programming and debugging. Instead we use open source Arduino platform which is easy to program and debug. Further phase measurement between voltage and current is simplified using Opamp and EXOR gate based circuit. To avoid adverse effect on THD we have used thyristor based capacitor switching instead of relay driver. II. METHODOLOGY Our system would be targeted towards power factor detection and correction in single phase and also 3 phase system with minor modifications. For this we plan to use Arduino microcontroller platform based system. The reason is ease of using and programming Arduino platform. Arduino is open source general purpose prototyping platform based on AVR 8 bit microcontroller series. [5] Voltage and current from power line is stepped down to low power level suitable for Arduino processing using PT and CT transformers. Then zero crossing of both signals is found using Opamp based ZCD circuit. From the two ZCD signals a pulse is generated using digital EXOR gate. The width of this pulse is proportional to the phase difference between voltage and current in power line. From this data power factor can be estimated. III. FLOW CHART MODELS DESIGNS Further this value will be used to find the required size of capacitor to be switched in power line to bring power factor back to unity. Arduino is programmed to find pulse width, calculate power factor and calculate required capacitance value. Then arduino will add estimated capacitor in power line for PFC. Further improvement in PF is monitored on continuous basis by Arduino to see if PFC is carried out by addition of estimated capacitor in power line. The entire process flow will be displayed on LCD. Figure shows the simplified block level arrangement of system. Fig 3 Algorithm In above algorithm the flow of project is shown, our project works in such process and we are designing our project in such manner that all above processes are covered under it. Thus, the software model is designed and it can be observed as in following sections as well as a hardware model for the same. IV. SOFTWARE MODELS DESIGNS Fig 2 Block diagram of system In software we are going to handle phase difference measurement between voltage and current in power line, calculation of power factor and required capacitance to bring power actor back to unity and adding that capacitance to line. Also we do displaying of process flow on LCD for user feedback. Following is circuit plan for Arduino based automatic PFC. 5

Schematic in figure is simplified is representing driver for Triac circuit. The complete driver circuit for Triac can be seen in following software model figure. This software model gives us a graphical as well as the numerical outputs from this software model we are able to design the hardware model and be analyzing software and hardware we had completed our project. width we have effectively measured phase difference between voltage and current signal. D. Power factor measurement: From the value of measured pulse width the Arduino now finds out the power factor. E. Capacitor calculation: From power factor it finds out required value of capacitor to bring power factor back to unity. For this we use following formula. C=KVAR / (2xpixfxVrmsxVrms) F. Capacitor switching: Arduino then adding required capacitor value across the load using thyristor based switching scheme. It generates the required gate drive for thyristor to switch it ON. G. Thyristor based capacitor bank: The capacitor bank used in our project is thyristor based. capacitor is added in line. V. HARDWARE MODELS DESIGNS Fig 4 Proteus VSM simulation for system Here system is divided into following major components. A. Zero crossing detection of voltage and current signal: Zero crossing detection is done for both voltage and current signals. The power signal voltage is stepped down to lower level using 6-0-6/750mA step down transformer and then is applied to LM358 based ZCD circuit. The ZCD circuit then gives zero crossings for voltage signal. For power line current we use noninvasive current transformer to step down it to lower level. This signal is then applied to ZCD to get its zero crossing. From these to ZCD outputs we know the phase difference between voltage and current signals using single XOR gate. B. Pulse generation corresponding to phase difference between voltage and current: The two ZCD outputs are then applied to EXOR logic gate to get a pulse corresponding to phase difference between voltage and current signal. Arduino based decision making: The arduino microcontroller forms the main decision maker here. Its functions can be divided into following component parts. C. Phase difference measurement: The pulse output from EXOR gate is applied to Arduino. The Arduino then measures the width of pulse. The pulse width corresponds to phase difference measurement. Thus by measuring pulse Following is the snap of complete system. The system was tested with 2 inductive loads in series with 200 watt resistive load. The inductive load can be added/removed from circuit using switch. Detection of power factor by system was checked once for resistive load and than for added inductive load. Figure 5: Actual setup When the load is purely resistive the system detects so and also the corresponding PF of 0.99 is displayed on lcd. The in-phase waveforms of V and I can be seen on oscilloscope. When the load is made inductive by adding an inductance is series with resistance, the net load is inductive and the corresponding lag created between V and I can be clearly seen on oscilloscope. The system detects this condition and corresponding PF is displayed on LCD. The system reliably detects leading and lagging PF conduction and switches capacitor from bank to correct it. Following is the table to illustrate calculated PF and detected PF by system for various load conditions. The calculated values are based on measured current 6

in line using clamp meter. The following figures show the characteristics from project and the readings with respect to those characteristics. VI. RESULT ANALYSIS TABLE 1 Result Comparison Figure 6: Purely resistive load CONCLUSION Fig 11 Characteristics Analysis Figure 7: V and I waveforms when load is purely resistive Figure 8: V and I waveforms when load is inductive Figure 9 Lagging PF detected by system Figure 10: PF correction by system By using Arduino microcontroller platform the system is made automatic detector of PF lag/lead condition. Again by using Triac based switching of capacitor bank the THD is reduced compared to relay based switching. The results obtained with various load conditions are satisfactory and the system would make a cost effective solution for automatic power factor improvement in industrial environment. Further the system can be modified for monitoring power changes over period using Data logging methods. Also same data logging techniques can be used for more scientific analysis of PF of a certain facility. ACKNOWLEDGMENT For our pleasure we are presenting deepest gratitude towards all those who have contributed their valuable efforts and time directly or indirectly in completing our project work as curricular activity. We express our sincere gratitude towards all the facilities offered in the institute. We have unhesitatingly approached our faculty members for guidance for preparing project. REFERENCES [1] G.PREMKUMAR, Design, Fabrication and Implementation of Microcontroller Controlled Static Var Compensator, International Journal of Computer Applications, vol. 81, pp. 43-50, Nov 2013. [2] S. B. Jamge, Automatic Power Factor Controller using PSoC3, International Journal of Engineering Research & Technology, vol. 3, pp. 1056-1058, May. 2014. [3] Anant Kumar Tiwari, Automatic Power Factor Correction Using Capacitive Bank, International Journal 7

of Engineering Research and Applications, vol-4, Page- 393-395, Feb- 2014 [4] Murad Ali, Design and Implementation of Microcontroller-Based Controlling of Power Factor Using Capacitor Banks with Load Monitoring, Global Journal of Researches in Engineering Electrical and Electronics Engineering, Vol-13, pp. 21-31, 2013 8