R&S FS-K112PC NFC Measurement Software Specifications

Similar documents
Analog Modulation Analysis (AM/FM/φM) Specifications

R&S RSC Step Attenuator Specifications

R&S ZN-Z5x Calibration Units Specifications. Data Sheet V03.00

R&S ZN-Zxxx Calibration Units Specifications. Data Sheet V04.00

R&S ZV-Z3xx T-Checker Specifications

Noise Figure Measurement Applications Specifications

R&S ZV-Z135 Calibration Kit Specifications

R&S ZVT Vector Network Analyzer Specifications

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications

R&S ZVT Vector Network Analyzer Specifications

R&S ZNB Vector Network Analyzer Specifications

R&S ZV-Z5x Calibration Units Specifications

R&S EB500 Monitoring Receiver Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Network analysis up to 500 GHz

R&S FSC Spectrum Analyzer Specifications

Attenuators and Matching Pads, Terminations 75 mw to 1000 W, DC to 18 GHz

R&S ZVL Vector Network Analyzer Specifications

Guide Version Five techniques for fast, accurate power integrity measurements

R&S ZV-Z5x Calibration Units Specifications

Data Sheet Version R&S RT-ZVCxx Multi-Channel Power Probe Specifications

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

R&S FPC Spectrum Analyzer Specifications

R&S TS8997 Regulatory Test System for Wireless Devices

Bring satellites into your lab: GNSS simulators from the T&M expert.

R&S FU129 Antenna Filter Unit Antenna switching, rotator control and signal attenuation, amplification and filtering

Vector Network Analyzers ZVB

R&S CBT/R&S CBT32 Bluetooth Tester Specifications

Modulation Accuracy Measurements of DVB-S2 and DVB-S2X Signals Application Note

R&S CLGD DOCSIS Cable Load Generator Multichannel signal generator for DOCSIS 3.1 downstream and upstream

R&S TS-EMF EMF Measurement System Easy, frequency-selective measurement of EMF emissions

R&S SMC100A Signal Generator Specifications

R&S FSx-K91/-K91n, R&S FSW/FSQ-K91ac WLAN Application Firmware WLAN TX measurements with Rohde & Schwarz analyzers

R&S FSWP Phase Noise Analyzer Specifications

Power Added Efficiency Measurement with R&S ZNB/ R&S ZVA

R&S ZNA Vector Network Analyzer Specifications

R&S FSWP Phase Noise Analyzer Specifications

R&S ESCI/ESCI7 EMI Test Receiver Specifications

R&S NRP-Zxx Power Sensors Specifications

R&S ESRP EMI Test Receiver Specifications

R&S NRP Power Meter Family Specifications

Measurement Setup for Phase Noise Test at Frequencies above 50 GHz Application Note

Noise Figure Measurement in the 60 GHz Range Application Note

LabWindows/CVI, VXIpnp driver history for the R&S Radio Tester

R&S NRP USB and LAN Power Sensors Specifications

R&S TSMW, TSME, TSMA LTE Downlink Allocation Analysis Application Note

Spectrum Analyzer FSL

R&S FSH4/8 Spectrum Analyzer Specifications

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

Bring satellites into your lab

Receiver requirements for a TDOA-based radiolocation system

Near Field Communication (NFC) Technology and Measurements White Paper

R&S TS-PSAM Analog Source and Measurement Module Scanning multimeter and data acquisition unit

Signal Generator SMA 100A

R&S CMU-Z10/-Z11 Antenna Coupler/ RF Shielding Cover Simple interference-free testing of all mobiles

Evolution of the Modern Receiver in a Crowded Spectrum Environment White Paper

Group Delay measurements with Signal and Spectrum Analyzers Application Note

R&S ESR EMI Test Receiver Specifications

Application Firmware for Phase Noise Measurements FS-K40

R&S FPL1000 Spectrum Analyzer Experience high performance wherever you take it

Trends in connected cars at a glance V2X V2V, V2I, V2P, C-V2X, 3GPP LTE-V2X, DSRC, WAVE, ITS-G5, IEEE p

R&S EM510 HF Digital Wideband Receiver Efficient and versatile solution for radiomonitoring

Wideband mm-wave Signal Generation and Analysis

R&S ESRP EMI Test Receiver Specifications

R&S FSV Signal Analyzer Specifications

R&S FSV Signal and Spectrum Analyzer Specifications

R&S SMB100N SIGNAL GENERATOR

R&S UMS175 Compact Radiomonitoring System High performance for outdoor deployment

Radio Network Analyzer TSMU/TSMU-H

Signal Generator SMA100A

GSM/EDGE Application Firmware R&S FS-K5 for R&S FSP and R&S FSU

R&S ZVH Cable and Antenna Analyzer Specifications

R&S DF-ATC-S ATC DF System Solution Accurate and reliable direction finding for civil and military air traffic control

Spectrum Analyzer R&S FS300

R&S NRT Power Reflection Meter Family R&S NRT2 and R&S NRT-Zxx

R&S SMA100A Signal Generator The new standard of excellence in the analog signal generator class

R&S NRPC Calibration Kits Calibration of power sensors

Measuring Receiver FSMR

R&S MNT100 RF Interference Locator Specifications

RF Signal Generator SM300

Voltage Sensors URV5-Z

R&S ZVH Cable and Antenna Analyzer Specifications

R&S NRPC Calibration Kits Calibration of power sensors

R&S OSP Open Switch and Control Platform Specifications

MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp

FMU36 Baseband Signal Analyzer

R&S CMW100 Communications Manufacturing Test Set Specifications

R&S OSP Open Switch and Control Platform Specifications

R&S FSUP Signal Source Analyzer Specifications

R&S ETH Handheld TV Analyzer Specifications

R&S NRP USB and LAN Power Sensors Specifications

R&S ZVH Cable and Antenna Analyzer Where mobility counts

ENY81 Coupling Network

R&S ESR EMI Test Receiver Specifications

SMA100A Signal Generator

R&S MNT100 RF Interference Locator

Provided by R&S FSH4/FSH8 Spectrum Analyzer Specifications

Automated Measurements of 77 GHz FMCW Radar Signals

R&S CMW100 Communications Manufacturing Test Set Specifications

DSA700 Series Spectrum Analyzer

Transcription:

FS_K112-PC_dat-sw_3606-7047-22_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S FS-K112PC NFC Measurement Software Specifications 06.10.2014 18:19:15

CONTENTS Definitions... 3 Specifications... 4 Minimum system requirements for R&S FS-K112PC software... 4 Running on a PC... 4 Measurement parameters... 4 Result display... 4 General results... 4 NFC-A specific results... 4 NFC-B specific results... 5 NFC-F specific results... 5 R&S FSL/ZVL/FSV/FSW... 6 Frequency... 6 Level... 6 Signal acquisition... 6 R&S RTO input source... 6 Frequency... 6 Level... 6 Signal acquisition... 6 R&S FSV/FSL/FSW measurement uncertainty (nominal)... 7 NFC-A specific parameters... 7 NFC-B specific parameters... 7 NFC-F 212kB specific parameters... 7 NFC-F 424kB specific parameters... 7 R&S ZVL measurement uncertainty (nominal)... 8 NFC-A specific parameters... 8 NFC-B specific parameters... 8 NFC-F 212kB specific parameters... 8 NFC-F 424kB specific parameters... 8 R&S RTO measurement uncertainty (nominal)... 9 NFC-A specific parameters... 9 NFC-B specific parameters... 9 NFC-F 212kB specific parameters... 9 NFC-F 424kB specific parameters... 9 Ordering information... 10 The specifications of the R&S FS-K112PC NFC Measurement Software are based on the data sheet specifications of the R&S FSV, R&S FSW and R&S FSL signal and spectrum analyzers, the R&S ZVLvector network analyzer and the R&S RTO digital oscilloscope, have not been checked separately and are not verified during instrument calibration. Measurement uncertainties are given as 95 % confidence intervals. The specified level measurement errors do not take into account systematic errors due to reduced signal to noise ratio (S/N). Chip rates are specified in Mcps (million chips per second), whereas bit rates and symbol rates are specified in kbps (thousand bits per second) or ksps (thousand symbols per second). Mcps, kbps and ksps are not SI units. 2 Rohde & Schwarz R&S FS-K112PC NFC Measurement Software

Definitions General Product data applies under the following conditions: Three hours storage at ambient temperature followed by 30 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <,, >,, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable. Specifications without limits Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design. Typical data (typ.) Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean value. Nominal values (nom.) Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to typical data, a statistical evaluation does not take place and the parameter is not tested during production. Measured values (meas.) Characterize expected product performance by means of measurement results gained from individual samples. Uncertainties Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account environmental conditions, aging, wear and tear. Device settings and GUI parameters are designated with the format parameter: value. Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz. Rohde & Schwarz R&S FS-K112PC NFC Measurement Software 3

Specifications Minimum system requirements for R&S FS-K112PC software The R&S FS-K112PC software is compatible with the R&S FSV/FSL/ZVL/FSW signal and spectrum analyzers and the R&S RTO digital oscilloscope. Running on a PC Operating system Windows XP Professional + Service Pack 2, Windows 7 Free hard disk space 50 Mbyte Free RAM 512 Mbyte Graphics resolution 800 600 pixel Measuring instrument connection IEC/IEEE bus or LAN connection, VISA driver Measurement parameters Input Supported NFC modulations Supported NFC bitrates NFC reference poller used for listener tests Peak to RMS factor RF NFC-A, NFC-B, NFC-F 106 kbit/s, 212 kbit/s, 424 kbit/s poller 0, poller 3, poller 6 Result display General results Result overview Analyzed standard Analyzed bitrate Poller RF state Listener RF state Functional test state Number of detected poller signals (NFC-A, NFC-B and NFC-F) Decoding Detected poller commands Detected listener commands NFC-A specific results Poller values Unit t 1 µs t 2 µs t 3 µs t 4 µs t 5 µs Overshoot V O, A % Amplitude shift keying modulation depth % Listener values Load modulation mv Frame delay time listener (only available if a listener answer has been detected) µs Frame delay time poller µs (only available if the poller answered to the listener s SENS RES command) Offtime t off µs 4 Rohde & Schwarz R&S FS-K112PC NFC Measurement Software

NFC-B specific results Poller values Unit Fall time t f, B µs Rise time t r, B µs Overshoot V O,B % Undershoot V U, B % Modulation index m i, B % Listener values Load modulation mv Frame delay time listener (only available if a listener answer has been detected) µs Frame delay time poller µs (only available if the poller answered to the Listener s SENS RES command) Offtime t off µs NFC-F specific results Poller values Unit Fall time t f, F µs Rise time t r, F µs Overshoot V O, F % Undershoot V U, F % Modulation index m i, F % Listener values Load modulation mv Frame delay time listener (only available if a listener answer has been detected) µs Frame delay time poller µs (only available if the poller answered to the listener s SENS RES command) Offtime t off µs Rohde & Schwarz R&S FS-K112PC NFC Measurement Software 5

R&S FSL/ZVL/FSV/FSW Frequency Center frequency range 13.0 MHz to 14.0 MHz Level Level range RF input 50 dbm to +30 dbm Signal acquisition Capture length R&S FSL/ZVL 0.05 ms to 25 ms R&S FSV/FSW 0.05 ms to 100 ms Sample rate 5 MHz to 20 MHz Trigger modes RF input free run, external, IF power Coupling 50 Ω R&S RTO input source Frequency Center frequency range 13.0 MHz to 14.0 MHz Level Level range RF input 50 dbm to +30 dbm Signal acquisition Capture length 0.05 ms to 100 ms Sample rate 5 MHz to 20 MHz Trigger modes RF input free run, external, poller SENS REQ trigger for NFC-A, NFC-B, NFC-F212 and NFC-F424 Input channel channel 1, channel 2, channel 3, channel 4 Coupling 50 Ω or 1000 Ω 6 Rohde & Schwarz R&S FS-K112PC NFC Measurement Software

R&S FSV/FSL/FSW measurement uncertainty (nominal) The measurement uncertainty has been measured by connecting the RF output of a vector signal generator directly to the RF input of the R&S FSx. The signal generator has been configured to use a carrier frequency of 13.56 MHz and an output level of 10 dbm. The measurements have been triggered by using an external trigger signal which was supplied by the marker output of the generator. A sample rate of 20 MHz has been used for the measurements. NFC-A specific parameters t 1 µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz t 2 µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz t 3 µs < 0.03 < 2/f carrier 0.14 for f carrier = 13.56 MHz t 4 µs < 0.03 < 2/f carrier 0.14 for f carrier = 13.56 MHz V O, A % < 0.5 < 0.5 NFC-B specific parameters t r, B µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz t f, B µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz V O, B % < 0.5 < 0.5 V U, B % < 0.5 < 0.5 m i, B % < 0.5 < 0.5 valid for modulation NFC-F 212kB specific parameters t r, F µs < 0.13 < 2/f carrier 0.14 for f carrier = 13.56 MHz t f, F µs < 0.13 < 2/f carrier 0.14 for f carrier = 13.56 MHz V O, F % < 0.5 < 0.5 V U, F % < 0.5 < 0.5 m i, F % < 0.5 < 0.5 valid for modulation NFC-F 424kB specific parameters t r, F µs < 0.13 < 2/f carrier 0.14 for f carrier = 13.56 MHz t f, F µs < 0.13 < 2/f carrier 0.14 for f carrier = 13.56 MHz V O, F % < 0.5 < 0.5 V U, F % < 0.5 < 0.5 m i, F % < 0.5 < 0.5 valid for modulation Rohde & Schwarz R&S FS-K112PC NFC Measurement Software 7

R&S ZVL measurement uncertainty (nominal) The measurement uncertainty has been measured by connecting the RF output of a vector signal generator directly to the RF input of the R&S ZVL. The signal generator has been configured to use a carrier frequency of 13.56 MHz and an output level of 10 dbm. The measurements have been triggered by using an external trigger signal which was supplied by the marker output of the generator. For the R&S ZVL measurements a sampling rate of 16.5 MHz has been used. NFC-A specific parameters t 1 µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz t 2 µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz t 3 µs < 0.03 < 2/f carrier 0.14 for f carrier = 13.56 MHz t 4 µs < 0.03 < 2/f carrier 0.14 for f carrier = 13.56 MHz V O, A % < 0.5 < 0.5 NFC-B specific parameters t r, B µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz t f, B µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz V O, B % < 0.5 < 0.5 V U, B % < 0.5 < 0.5 m i, B % < 1.4 < 0.5 valid for modulation NFC-F 212kB specific parameters t r, F µs < 0.13 < 2/f carrier 0.14 for f carrier = 13.56 MHz t f, F µs < 0.13 < 2/f carrier 0.14 for f carrier = 13.56 MHz V O, F % < 0.5 < 0.5 V U, F % < 0.5 < 0.5 m i, F % < 1.4 < 0.5 valid for modulation NFC-F 424kB specific parameters t r, F µs < 0.13 < 2/f carrier 0.14 for f carrier = 13.56 MHz t f, F µs < 0.13 < 2/f carrier 0.14 for f carrier = 13.56 MHz V O, F % < 0.5 < 0.5 V U, F % < 0.5 < 0.5 m i, F % < 1.4 < 0.5 valid for modulation 8 Rohde & Schwarz R&S FS-K112PC NFC Measurement Software

R&S RTO measurement uncertainty (nominal) The measurement uncertainty has been measured by connecting the RF output of a vector signal generator directly to the CH1 input of the R&S RTO. The signal generator has been configured to use a carrier frequency of 13.56 MHz and an output level of 10 dbm. The measurements have been triggered by using an external trigger signal which was supplied by the marker output of the generator. A sample rate of 20 MHz has been used for the measurements. NFC-A specific parameters t 1 µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz t 2 µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz t 3 µs < 0.03 < 2/f carrier 0.14 for f carrier = 13.56 MHz t 4 µs < 0.03 < 2/f carrier 0.14 for f carrier = 13.56 MHz V O, A % < 0.5 < 0.5 NFC-B specific parameters t r, B µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz t f, B µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz V O, B % < 0.5 < 0.5 V U, B % < 0.5 < 0.5 m i, B % < 0.5 < 0.5 valid for modulation NFC-F 212kB specific parameters t r, F µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz t f, F µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz V O, F % < 0.5 < 0.5 V U, F % < 0.5 < 0.5 m i, F % < 0.5 < 0.5 valid for modulation NFC-F 424kB specific parameters t r, F µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz t f, F µs < 0.09 < 2/f carrier 0.14 for f carrier = 13.56 MHz V O, F % < 0.5 < 0.5 V U, F % < 0.5 < 0.5 m i, F % < 0.5 < 0.5 valid for modulation Rohde & Schwarz R&S FS-K112PC NFC Measurement Software 9

Ordering information Designation Type Order No. NFC Measurement Software R&S FS-K112PC 1310.0448.06 License Dongle R&S FSPC 1310.0002.02 Signal and Spectrum Analyzer R&S FSV4 1321.3008.04 Signal and Spectrum Analyzer R&S FSW8 1312.8000K08 Vector Network Analyzer R&S ZVL 1303.6509.75 Spectrum Analyzer R&S FSL 1300.2508Kxx Digital Oscilloscope R&S RTO 1316.1000.xx with R&S RTO-K11 option 1317.2975.02 An R&S FSPC license dongle is necessary to run the R&S FS-K112PC NFC measurement software. Existing license dongles can be used. References [1] NFC Analogue Specification Technical Specification, NFC Forum TM, Analog1.0, NFC Forum-TS-Analog-v1.0, 2012-07-11. [2] Test Cases for NFC RF Analogue Specification NFC Forum TM, ANALOGUE_TC 1.0.00, NFC Forum_TestCases for Analogue, 2012-05-04, CONFIDENTIAL DRAFT. For product brochure, see PD 3606.7047.12 and www.rohde-schwarz.com 10 Rohde & Schwarz R&S FS-K112PC NFC Measurement Software

Rohde & Schwarz R&S FS-K112PC NFC Measurement Software 11

Service that adds value Worldwide Local and personalized Customized and flexible Uncompromising quality Long-term dependability About Rohde & Schwarz The Rohde & Schwarz electronics group is a leading supplier of solutions in the fields of test and measurement, broadcasting, secure communications, and radiomonitor ing and radiolocation. Founded more than 80 years ago, this independent global company has an extensive sales network and is present in more than 70 countries. The company is headquartered in Munich, Germany. Sustainable product design Environmental compatibility and eco-footprint Energy efficiency and low emissions Longevity and optimized total cost of ownership Certified Quality Management ISO 9001 Certified Environmental Management ISO 14001 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners PD PD 3606.7047.22 Version 03.00 October 2014 (as) R&S FS-K112PC NFC Measurement Software Data without tolerance limits is not binding Subject to change 2012-2014 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany PD 3606.7047.22 03.00 PDP 1 en Regional contact Europe, Africa, Middle East +49 89 4129 12345 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China +86 800 810 8228 +86 400 650 5896 customersupport.china@rohde-schwarz.com 3606704722 FS_K112-PC_dat-sw_3606-7047-22_cover.indd 2 06.10.2014 18:19:15