Faculty of Electrical Engineering

Similar documents
ANALYSIS OF FAULTS IN THREE PHASE VOLTAGE SOURCE INVERTER NURUL ASSHIKIN BINTI KASIM

SPACE VECTOR MODULATION FOR FIVE-PHASE INDUCTION SPEED DRIVE CONTROL NORAZELINA BINTI KAMISMAN. of Bachelor in Electrical Engineering

HOUMAN OMIDI. A project report submitted in partial fulfilment of the. Master of Engineering (Electrical-Power) Faculty of Electrical Engineering

THERMAL ANALYSIS OF H.V INSULATION OIL DURING PARTIAL DISCHARGE DETECTION RASOOL ABDELFADIL GATEA UNIVERSITI TEKNOLOGI MALAYSIA

MODELING, SIMULATION AND DESIGN OF AN IMPROVED HIGH POWER FACTOR BRIDGELESS SEPIC CONVERTER IZNI BINTI MUSTAFAR UNIVERSITI TEKNOLOGI MALAYSIA

LAPORAN PROJEK SARJANA MUDA

UNIVERSITI TEKNIKAL MALAYSIA MELAKA FACULTY OF ELECTRICAL ENGINEERING FINAL YEAR PROJECT II (FYP II) BEKU 4973

CARBON NANOTUBE FIELD-EFFECT TRANSISTOR FOR A LOW NOISE AMPLIFIER NGU KEK SIANG UNIVERSITI TEKNOLOGI MALAYSIA

NURSYAHIDA ASHIKIN BINTI NOR IZLANIN

INTEGRATED SYSTEM OF AUTOMATIC IDENTIFICATION SYSTEM (AIS) AND RADAR FOR PORT TRAFFIC MANAGEMENT NUR AIREEN BT. AMRAN UNIVERSITI TEKNOLOGI MALAYSIA

PRODUCT DESIGN IMPROVEMENT USING DESIGN FOR MANUFACTURE AND ASSEMBLY (DFMA) METHODOLOGY

SOFTWARE PROCESS FOR INTEGRATED PATTERN ORIENTED ANALYSIS AND DESIGN (POAD) AND COMPONENT ORIENTED PROGRAMMING (COP) ON EMBEDDED REAL-TIME SYSTEMS

HARMONIC MODELING IN POWER DISTRIBUTION SYSTEM USING TIME SERIES SIMULATION CHE KU FARHANA BINTI CHE KU AMRAN UNIVERSITI TEKNOLOGI MALAYSIA

: NORHAZILINA BT BAHARI

FACULTY OF ELECTRICAL ENGINEERING UNIVERSITI TEKNIKAL MALAYSIA MELAKA FINAL YEAR PROJECT II PERFORMANCE ANALYSIS OF 100 W BOOST CONVERTER

Nur Athykah binti Basiran

Mohd Hafizi Bin Ab Rahim

SURVEILLANCE ROBOT MUHAMMAD BUKHARI BIN KAMAROZAMAN

SLIDING MODE CONTROL FOR DC-AC CONVERTER POUYA IZADIFAR

CONTINUOUS INDIVIDUAL PLOT CURVES TECHNIQUE FOR SIMULTANEOUS TARGETING AND DESIGN OF A MASS EXCHANGE NETWORK YANWARIZAL UNIVERSITI TEKNOLOGI MALAYSIA

DEVELOPMENT OF MONOPOLE SENSORS FOR RICE QUALITY CHARACTERIZATION IN MALAYSIA JAMALIAH BINTI SALLEH

CONTRIBUTION OF HUMAN FACTORS TO SHIPPING SAFETY ARFENA DEAH LESTARI

DETERMINATION OF LEAKAGE IN AN OIL AND GAS PIPELINE NOR AZIAN BINTI MOHIDEEN ABDUL KADIR

Eliakim Bin Che Yaacob

THE PRE-SIZING APPROACH OF DC-DC CONVERTER AS THE APPLICATION TO DESIGN A BUCK CONVERTER FOR THE AUTOMOTIVE DOMAIN NOOR SUHADA BINTI AB RAZAK

MITIGATION OF POWER QUALITY PROBLEMS USING ACTIVE POWER FILTER MUNIRAH BINTI ROSLI

SYSTEM IDENTIFICATION AND POSITION CONTROL OF PNEUMATIC ACTUATOR USING EMBEDDED SYSTEM TAHA MOHAMMED AHMED SADEQ

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

OPTIMAL HEAT TRANSFER OF HEAT SINK DESIGN BASED ON ELECTRONIC PACKAGE THERMAL DISTRIBUTION USING COMSOL PACKAGE SOFTWARE

SILICON NANOWIRE FIELD-EFFECT TRANSISTOR (SINWFET) AND ITS CIRCUIT LEVEL PERFORMANCE SITI NORAZLIN BINTI BAHADOR UNIVERSITI TEKNOLOGI MALAYSIA

ENHANCEMENT OF VOLTAGE STABILITY AND POWER LOSSES FOR DISTRIBUTION SYSTEM WITH DISTRIBUTED GENERATION USING GENETIC ALGORITHM OMAR TAHSEEN OMAR KHALAF

HIGH-PERFORMANCE DIGITAL FILTER IN FPGA SITI SUHAILA MOHD YUSOF UNIVERSITI TEKNOLOGI MALAYSIA

This item is protected by original copyright

DYNAMIC ANALYSIS OF AIRCRAFT LANDING GEAR SADEGH IMANI YENGEJEH

ADAPTIVE CROSS WIGNER-VILLE DISTRIBUTION FOR PARAMETER ESTIMATION OF DIGITALLY MODULATED SIGNALS CHEE YEN MEI

ARDUINO BASED SPWM THREE PHASE FULL BRIDGE INVERTER FOR VARIABLE SPEED DRIVE APPLICATION MUHAMAD AIMAN BIN MUHAMAD AZMI

EFFECTIVENESS OF SAFETY PROGRAMS IN MALAYSIAN CONSTRUCTION INDUSTRY JAIMEY ATTAU

FINAL YEAR PROJECT REPORT TITLE: MODELING AND PSO-BASED LQR CONTROLLER DESIGN FOR COUPLED TANK SYSTEM FIONA SERINA DAUD B

SPDT SWITCH DESIGN USING SWITCHABLE RESONATOR AT 5GHZ FOR WIRELESS COMMUNICATIONS MOHD HAIDIL BIN ZURAIMI UNIVERSITI TEKNIKAL MALAYSIA MELAKA

ANALYSIS OF MARINE INCIDENTS IN MALAYSIA SURHAN JAMIL BIN HARON

MICROWAVE PARAMETERS FOR BITUMEN EMULSION AND ITS APPLICATION IN HIGHWAY ENGINEERING NAJEEB ULLAH KHAN

COMPARATIVE EVALUATION OF EXISTING PRODUCT FOR ECO-DESIGN AHMAD ARIF FAHMI BIN TURIN B BMCD.

A GRAY-SCALE IMAGE STEGANOGRAPHY TECHNIQUE USING FIBONACCI 12-BITPLANE DECOMPOSITION AND LSB APPROACH SABAH FADHEL HAMOOD

UNIVERSITI TEKNOLOGI MALAYSIA

COMPARATIVE STUDY OF REGTANGULAR MICROSTRIP PATCH ANTENNA ARRAY DESIGN ABDULLAHI MOALLIM YUSUF

SYSTEM IDENTIFICATION AND CONTROL OF THE HORIZONTAL MOTION OF A TWIN ROTOR MULTI-INPUT MULTI-OUTPUT SYSTEM (TRMS) NURUL HAZIRAH BINTI ABD AZIZ

MICROCONTROLLER BASED THREE-LEVEL ZERO VOLTAGE SWITCHING PULSE WIDTH MODULATION DC-TO-DC CONVERTER SHAKINA BT ABU HASAN

NON-LINEAR WATER LEVEL FORECASTING OF DUNGUN RIVER USING HYBRIDIZATION OF BACKPROPAGATION NEURAL NETWORK AND GENETIC ALGORITHM SITI HAJAR BINTI ARBAIN

WIRELEES VIBRATION MONITORING SYSTEM (WVMS) WONG YOON KHANG APRIL 2007

GRAPHICS PROCESSING UNIT BASED PARALLEL COPY MOVE IMAGE FORGERY DETECTION SCHEME AHMAD UWAYS BIN ZULKURNAIN

COMPARISON BETWEEN PIEZOELECTRIC AND CAPACITIVE SENSORS FOR PD DETECTION AND SIGNAL MONITORING IN PALM OIL

iii I hereby declare that this report is the result of my own work except for quotes as cited in the references

TRACKING PERFORMANCE OF A HOT AIR BLOWER SYSTEM USING PID CONTROLLER WITH PSO AND HARMONIC SEARCH ALGORITHM ANDY HENG POH SENG

A DESIGN METHODOLOGY FOR A SELF-OSCILLATING ELECTRONIC BALLAST AMIRA BINTI MUSTAPA

DESIGN A WIDEBAND LOW-NOISE AMPLIFIER FOR WIRELESS COMMUNICATION USING 0.35-µm CMOS TECHNOLOGY MOHD HAFIZ BIN ABU

ENERGY ANALYSIS AND OPTIMIZATION OF PUBLIC BUILDING USING BUILDING INFORMATION MODELING APPLICATION

FAILURE OF OHM S LAW AND CIRCUIT DESIGN MOHAMMAD OBAIDUR RAHMAN

BORANG PENGESAHAN STATUS TESIS

LAPORAN PROJEK SARJANA MUDA

CORRELATIVE INTERFEROMETRY FOR ANGLE OF ARRIVAL ESTIMATION AND SIGNAL SOURCE LOCATING USMAN BATURE ISYAKU

POST-TENSION COLUMN FOR IBS BLOCKWORK BUILDING SYSTEM ZALILAH BINTI AYOP

PUMP SCHEDULING OPTIMIZATION FOR WATER SUPPLY SYSTEM USING ADAPTIVE WEIGHTED SUM GENETIC ALGORITHM FOLORUNSO TALIHA ABIODUN

DEVELOPMENT OF MODULAR JIGS AND FIXTURE FOR CATIA

EXPECTED LIFE CYCLE COST FOR SYSTEMS WITH REPAIRABLE COMPONENTS AMIRHOSSEIN EBRAHIMI

INTEGRATING COOPERATIVE USERS TO DEVELOP FRAMEWORK FOR AN EFFECTIVE MOBILE PHYSIOTHERAPY YOUCEF BENFERDIA

DEVELOPMENT OF REMOTELY OPERATED UNDERWATER VEHICLE AFIQ FIKRI BIN HAMID UNIVERSITI MALAYSIA PAHANG

PWM PIC16F877A DIMMING ELECTRONIC BALLAST FOR HPS LAMP NATRA BINTI ISMAIL

DISCRIMINATION OF OVERCURRENT AND EARTH FAULT OF A LOW VOLTAGE SYSTEM. Haznirah binti Mohd Ghazali

JPEG IMAGE TAMPERING DETECTION BASED ON BLOCKING ARTIFACTS ALI EBRAHIMI

18V TO 1000V BOOST CONVERTER BENNEDICT BALLY ANAK NAROK UNIVERSITI MALAYSIA PAHANG

BTST THIN FILM SENSOR APPLICATION: HEAT INDICATOR NUR FAIZAH BINTI JAAFAR

PRODUCT DESIGN EVALUATION OF LUCAS HULL DFMA METHOD MOHD NAFIS BIN MOHAIZI

OBJECT CLASSIFICATION USING DEEP LEARNING FONG SOON FEI

Design and Development of Planar Antenna for GSM Application ABDULHADI HASAN ALJOUMAH

PATTERN AND FREQUENCY RECONFIGURABLE ANTENNA FOR WIRELESS APPLICATIONS DELPHINE ABIJURU. requirements for the award of the degree of

ULTRA WIDEBAND ANTENNA WITH BAND NOTCH AT 5.8 GIGAHERTZ USING CONDUCTIVE SILVER COATED THIN FILM MOHD SUBRI BIN ABDUL RANI

FACULTY OF ELECTRICAL ENGINEERING UNIVERSITI TEKNIKAL MALAYSIA MELAKA FINAL YEAR PROJECT REPORT (FYP II)

STUDY ON THE CHARACTERISTICS OF CAPILLARY PLASMA ANTENNA ARRAY IN RADIO WAVE NOOR FADHILAH BINTI RAMLI

A 10-BIT 50 MEGA-SAMPLES-PER-SECOND PIPELINED ANALOG-TO-DIGITAL CONVERTER YUZMAN BIN YUSOFF UNIVERSITI TEKNOLOGI MALAYSIA

Signature. Supervisor :.. ~.~H-.~.~0~P..?.j.~H~~~.. ~.~.~ Date :...?./!!./~~ ~

MESOPYME-IEMA SOFTWARE PROCESS EVALUATION MODEL FOR SMALL AND MEDIUM SOFTWARE INDUSTRIES IMRAN BASHA

OPTIMUM ANALYSIS OF OFFSHORE STRUCTURES LIFTING PADEYES USING FINITE ELEMNT METHOD ABDELRAHIM MUSA MAHGOUB HAMADELNIL

IMPROVING THE DOCUMENTATION OF USER S REQUIREMENTS FOR E-SERVICE SYSTEMS USING SERVICE RESPONSIBILITY TABLE IBRAHIM SALIHU ANKA

ANTENNA ARRAY (DESIGN AT 28 GHz FOR 5G MOBILE NETWORK BASIL JABIR SHANSHOOL. A project submitted in partial fulfilment of the

STATIC AND DYNAMIC CONTROL OF NETWORK BASED ROTARY INVERTED PENDULUM SYSTEM ZAID BIN YAAKOB

WIRELESS POWER TRANSFER MONITORING. Ahmad Faiz Bin Ahmad Azahar Bachelor of Electrical Engineering. (Control, Instrumentation & Automation)

FAKULTI KEJURUTERAAN ELEKTRIK UNIVERSITI TEKNIKAL MALAYSIA MELAKA LAPORAN PROJEK SARJANA MUDA

MITIGATING INTER-CARRIER INTERFERENCE IN ORTHOGONAL FREQUENCY DIVSION MULTIPLEXING SYSTEM USING SCALED ALPHA PULSE SHAPING TECHNIQUE

FABRICATION OF PERPETUAL MOTION WATER DRINKING TOY BIRD CHEE SAI HOW UNIVERSITI MALAYSIA PAHANG

NURUL AFIQAH BINTI AZIZ

A HIGH SPEED 2D CONVOLUTION HARDWARE MODULE FOR IMAGE PROCESSING APPLICATIONS IN FPGA BEENAL BABA UNIVERSITI TEKNOLOGI MALAYSIA

Faculty of Mechanical Engineering UNIVERSITI MALAYSIA PAHANG

AN IMPROVED ACCURACY OF WEB SERVICE SELECTION BASED ON MULTI-CRITERIA DECISION MAKING AND WEB SERVICE MODELING ONTOLOGY

MOTOR SPEED CONTROLLER USING FUZZY LOGIC METHOD FOR PCB DRILLING OPERATION KHAIRUL AZMIL BIN ADZMI UNIVERSITI MALAYSIA PAHANG

DESIGN AND IMPLEMENTATION OF AN AUTONOMOUS SUMO ROBOT

PERFORMANCE OF INVERSE RESPONSE PROCESS WITH VARIATION OF PROCESS PARAMETERS AND TUNING METHODS LOW YEOK CHAN

DIGITAL CODING SIMULATION USING MICRO-RING RESONATOR FOR LONG DISTANCE COMMUNICATION MASOUD RANJBAR. Universiti Teknologi Malaysia

SMART BOOST CONVERTER FOR DC ENERGY SOURCE APPLICATION MUNIRAH BT AYUB

TRIPLE-BAND DIPOLE ANTENNA WITH ARTIFICIAL MAGNETIC CONDUCTOR FOR RADIO FREQUENCY IDENTIFICATION MAISARAH BINTI ABU UNIVERSITI TEKNOLOGI MALAYSIA

INSTRUCTION: This section consists of SIX (6) structured questions. Answer only FOUR (4) questions.

Transcription:

Faculty of Electrical Engineering DESIGNING OF FAULT S PATTERN FOR 3 PHASE INVERTER USING VB Nur Atiqah Masita Binti Hasan Degree of Electrical Engineering 2014

DESIGNING OF FAULT S PATTERN FOR THREE PHASE INVERTER USING VB NUR ATIQAH MASITA BINTI HASAN A thesis submitted in fulfilment of the requirements for the degree of Electrical Engineering Faculty of Electrical Engineering UNIVERSITI TEKNIKAL MALAYSIA MELAKA 2014

DECLARATION I declare that I have read through this thesis entitle Designing of fault s pattern for 3 phase inverter using VB and found that it has comply the partial fulfillment for awarding the degree of Bachelor Of Electrical Engineering (Power Electronic And Drive) Signature Supervisor s Name Date : : Puan Norhazilina binti Bahari :

APPROVAL I declare that this report entitle Designing of fault s pattern for 3 phase inverter using VB is the result of my own research except as cited in the references. The report has not been accepted for any degrees and is not concurrently submitted of any other degree. Signature Name Date : : Nur Atiqah Masita Binti Hasan :

DEDICATION To my beloved mother and late father

ii ACKNOWLEDGEMENT Thank you to Allah, I would never have been able to finish my report without certainty from Allah s.w.t. My appreciation also goes to the guidance of my committee members, help from friends, and support from my family. I would like to express my gratitude to my supervisor, Mdm. Norhazilina Binti Bahari, for the support on the way, useful comments and ideas, valuable suggestions and guidance on my project, and her patience through the learning process of this thesis. My sincere appreciation express to all my colleagues and others who have provided assistance at various occasions. The guidance and support received from all the members who contributed and who are contributing to this project. I am grateful for their constant support and help. Also not to forget my family that has always been there to support me all the way and to those who have contributed directly or indirectly towards in completing this report.. Thank you so much.

iii ABSTRACT The purpose of this project is to designing fault s pattern for three phase inverter using Visual Basic. As already known, the usage of inverter is widely important in the industry. Due the operation frequently, there are many type of fault may occur in the three phase inverter. The study of fault is extremely important and quite difficult to determine. The failure of switching also cannot be determine earlier. Therefore, the cost of maintenance and repairing the system is increased besides the other system is affected if the fault is failed or late to be determined. In order to determine the fault happen in the inverter, by designing in visualization is given clearer overview. Focusing in two main faults frequently are happened, which are open circuit of damage and short circuit of damage, the aspect including the characteristics and the position of fault may occur in the inverter is considered at first. The process to design the pattern the fault is facilitated. As an introduction, the current value of open switch in phase be zero for either the positive or negative half-cycle and the short circuit happen when switches is short circuited, basically happen when a wrong gate voltage. This project also represented the parameter is consider in the fault of three phase converters which are average current, RMS current and total harmonic distortion. The ideal signal of three phase inverter is represented in the visualization at first to give some overview. Usually, the investigation only diagnose the fault occur in the inverter. So, overalls, the goal of this project is achieved by the coding is run using Visual basic that the clearer for a good display of the fault is given. Some calculations are needed in process to design and the pattern of fault is created. The visualization is plotted in sine wave signal to give clearer pattern of faults three phase inverter.

iv ABSTRAK Tujuan projek ini adalah untuk mereka bentuk corak kerosakan untuk penyongsang tiga fasa menggunakan Visual Basic. Seperti yang telah diketahui, penggunaan penyongsang secara meluas penting dalam industri. Oleh kerana operasinya yang kerap, terdapat banyak jenis faktor boleh mengakibatkan kerosakan dalam penyongsang tiga fasa. Kajian daripada kerosakan adalah sangat penting dan agak sukar ditentukan. Kegagalan pensuisan juga tidak boleh ditentukan lebih awal. Oleh itu, kos penyelenggaraan dan membaik pulih sistem ini meningkat selain sistem lain terjejas jika kerosakan itu gagal atau lewat akan ditentukan. Untuk menentukan kerosakan berlaku dalam penyongsang, dengan mereka bentuk dalam visualisasi memberi gambaran yang lebih jelas. Memberi tumpuan dalam dua kerosakan utama yang sering berlaku adalah, kerosakan litar terbuka dan kerosakan litar pintas, aspek yang penting termasuklah ciri-ciri dan kedudukan boleh mengakibatkan kerosakan dalam penyongsang dikesan pada awal kerosakan. Proses untuk mereka bentuk corak yang bersalah itu dipermudahkan. Sebagai pengenalan, nilai semasa suis terbuka dalam fasa sifar untuk sama ada separuh kitar positif atau negatif dan litar pintas berlaku apabila suis dipintaskan, pada dasarnya berlaku apabila voltan suis yang salah. Projek ini juga menggunakan parameter yang dipertimbangkan dalam kerosakan penukar tiga fasa iaitu arus purata semasa, arus RMS semasa dan jumlah herotan harmonik. Isyarat yang ideal bagi tiga fasa inverter diwakili dalam visualisasi pada mulanya untuk memberikan beberapa gambaran. Biasanya, siasatan hanya mendiagnosis kerosakan berlaku dalam penyongsang. Jadi, matlamat projek ini dicapai dengan pengekodan dijalankan dengan menggunakan Visual asas yang lebih jelas untuk paparan yang baik daripada kesalahan itu telah diberikan. Beberapa pengiraan yang diperlukan dalam proses untuk mereka bentuk dan corak bersalah dicipta. Visualisasi diplotkan dalam isyarat gelombang sinus untuk memberi corak yang lebih jelas kesilapan tiga fasa penyongsang.

v TABLE OF CONTENTS CHAPTER TOPIC PAGE ACKNOWLEDGEMENT ii ABSTRACT iii TABLE OF CONTENTS v LIST OF FIGURES vii LIST OF TABLE viii LIST OF ABBREVIATIONS x LIST OF APPENDICES 1 INTRODUCTION 1.1 Overview 1 1.2 Problem Statement 2 1.3 Objective 2 1.4 Scope of Project 3 1.5 Contribution of Research 3 1.6 Report Outlines 4 2 LITERATURE REVIEW 2.1 Iroduction 5 2.1.1 The three phase VSI topology 6 2.1.2 Fault of the drive system 7 2.2 Related previous works. 14 2.3 Summary review 17 3 DESIGN METHODOLOGY 3.1 Project Methodology 18 3.2 Analytical Approach 22

vi CHAPTER TOPIC PAGE 4 RESULT AND DISCUSSION 4.1 Introduction 32 4.2 Software development (GUI) 32 4.3 Data verification from the GUI. 35 5 CONCLUSION 5.1 Summary of Thesis 46 5.2 Achievement of project 47 5.3 Suggestion for Future Works 47 REFERENCES 48 APPENDICES 50

vii LIST OF FIGURES FIGURE TITLE PAGE 2.1 The three phase VSI 6 2.2 Gating signals of the inverter in an ideal case 8 2.3 Shows open circuit of switch 9 2.4 The ac phase current machine waves for switch 11 base drive open circuit fault 2.5 The short-circuit of switch 12 3.1 General flowchart of the project 19 3.2 Flowchart the methodology of structure 21 project (Faults pattern) 3.3 The open circuit of switch 22 3.4 The short circuit of switch 23 3.5 The ideal pattern gating signal of the inverter 23 3.6 The fault pattern gating signal of the inverter 24 for open circuit of switch (lower) 3.7 The fault pattern gating signal of the inverter 24 for open circuit of switch (upper) 3.8 The fault pattern gating signal of the inverter 25 for short circuit of switch (lower) 3.9 Shows the fault pattern gating signal of the inverter 25 for short circuit of switch (upper) 3.10 Flowchart of designing fault s pattern 26 3.11 The Start Page of Visual Basic 2010 Ultimate. 28 3.12 The design form and tool in Visual Basic 28 4.1 Front panel of the system for Fault s pattern design 33 4.2 Time Frequency Representation 33

viii FIGURE TITLE PAGE 4.3 Timing Parameters 34 4.4 The display of three phase inverter circuit. 34 4.5 Bar chart of open circuit fault for phase A, B and C 41 4.6 Bar chart of short circuit fault for phase A, B and C 42

ix LIST OF TABLE TABLE TITLE PAGE 2.1 Switching voltage possibilities 3 phase VSI 9 2.2 Switching table for faulted operation when 11 switch 1 permanently open 2.3 Switching table for faulted operation when 13 switch 1 permanently shorted 3.1 Parts in front panel of the interface design 29 4.1 Example the display and data of No Fault 35 condition for phase A 4.2 Example the display and data of open circuit 36 Upper for phase A 4.3 Example the display and data of short circuit 37 Lower for phase A 4.4 Example the display and data of short circuit 38 upper for phase A 4.5 Example the display and data of short circuit 39 lower for phase A 4.6 The data for Open circuit fault for phase A, B and C 40 (Upper and Lower) 4.7 The data for Open circuit fault for phase A, B and C 42 (Upper and Lower) 4.8 General average and RMS current during fault 44

x LIST OF ABBREVIATIONS TFD - Time Frequency Distribution RMS - THD - TWD - Root Mean Square Total Harmonic Distortion Total Waveform Distortion TFR - Time Frequency Representation VB - Visual Basic GUI - Graphic User Interface DC - Direct Current AC - Alternating Current VSI - Voltage Source Inverter P.U - Per-unit System IDE - Integrated Development Environment

xi LIST OF APPENDICES APPENDIX TITLE PAGE A Gantt Chart 50 B Research Framework OT (RFOT) 51

1 CHAPTER 1 INTRODUCTION 1.1 Overview DC-AC inverters are electronic devices that widely used to produce AC power from low voltage DC energy in industry. Inverter do their job to perform two functions which are converts the DC into AC then set up the resulting AC to mains voltage level using the transformer. One of the inverter is the three phase inverters that are used for variable frequency drive application. It has been predicted that voltage-fed inverters will eventually replace all other types of converters in the near future[1]. The performance and effects are the important factor in industry, especially the usage power inverter, switching and control circuit. The inverters performance in their operation sometimes will cause the faults. The knowledge about the fault mode behavior of inverter extremely important to improved the system design, performance, quality operation and protection. There are various types may happen. In order to determine the faults that happen in the inverter, by designing the faults pattern in visual that will give clearer overview about the pattern of possible faults. The design of fault s pattern inverter that proposed, the inverter fault detects the faults occurrence and isolates the faulty leg[2]. After identifying the faults modes, related technique will use to analysis the faults. The analysis has been made for the key fault types which are open circuit fault or short circuit fault conditions. As awareness, a short circuit fault is a critical problem, because such a fault will cause permanent damage of the system[3]. The software of visual basic was selected because the potential to displaying the visualization fault clearly.

2 1.2 Problem statement This project is designing the fault s pattern for three phase inverter. Inverters are widely utilized to drive of ac motor. About 38% failures that found in the application of power inverter and mostly that come from power switches [4]. Unfortunately, the conditions of fault s pattern in the inverter only receive a little attention compared with fault diagnostic. This is because the faults happen in three phase inverter is difficult to determine. The failure of the switching inverter cannot detect earlier, it also will interrupt the other operation of the system such as can cause the thermal rating of the system. If this condition is happen, it will increase the cost of maintenance and need other process to analysis the failure. Other than that, without visualization, the faults happen in the inverter difficult to classify. It is because, there are many various types of faults that may possibly happen in the inverter. 1.3 Objective The main objective in this project is to design a system that can display the fault of three phase inverter. In order to achieve the goal of this project and solve the current problem, the objectives of this project are: 1. To design the fault s pattern of the 3 phase inverter using LabVIEW software as a tool in Visual Basic. 2. To analyze and evaluate the fault characteristic and relevantparameters in 3 phase inverter.

3 1.4 Scope of project In producing a successful analysis, work, and some project, the scope is required to assist and set the directions of the project development. These scope should be identified and planned appropriately. For the scope of this project are, the fault s pattern during open circuit damage and short circuit damage for three phase inverter. The program coding is run in visual basic which will displaying the pattern of faults usinglabview by National Instrument library. The faults will be displayed are open circuit fault and short circuit fault only. 1.5 Contribution of research As stated before, the knowledge and information about the behavior of the inverter is important to improve design and protection. The study of fault performance is extremely complex. The important faults types are identified in the beginning that is then followed by preliminary analysis [5]. Focusing in open circuit damage of switch and short-circuit damage of switch, these two faults was usually happen in the inverter. As designing the fault s pattern for three phase inverter by using visual basic, it will give clearer overview in form of gating signal switching devices. This project also can be use for learning session, because the faults in inverter were something that never gets attention in study of power electronic.

4 1.6 Report outlines In the first chapter, stated the introduction about the project. Briefly, it described about the overview or project background, problem statement, objectives, scope and contribution of research. The part of overview was explained about the current situation and correlation problem that related of fault inverter because, nowadays, the inverter used as drivers system in industry. The problem statement stated a concise description of the issued that need to be addressed before the designing of fault pattern is to be design. For the objective, it stated a specific result that this project aimed to achieve like to study and knowing about the faults types and to design the faults pattern. While the scope is focused only on two types of faults that will be design by using the proposed software which is Visual Basic. For the chapter two, it was explain about the project literature review of three phase inverter and the study in faults types that may happen in the inverter. The focused explanation is in open circuit damage of switch and short circuit damage of switch.the related previous works for this project mostly more focused in diagnosis and analysis in faults types. It also stated in chapter two. The flowchart, analytical approach is introduced in chapter three. This chapter includes the framework of the project progress. It gives a lot of help in process to accomplishthis project. To give a description, this chapter also included the software design and development. The chapter four stated covered the discussions of results on the performance analysis for the time frequency distribution and developed system. This thesis ends with the conclusion and recommendations for further research as presented in Chapter 5

5 CHAPTER 2 LITERATURE REVIEW 2.1 Introduction Nowadays, the potential performance of driver will give the advantages to the system. The better performance of specifications and productivity interest lead to demand operating the operation in industry or any engineering system. The requirement to maintain the operation of the system is very important in order to ensure the efficiency, productivity and safety aspect are always under control. In developing the system of driver, a critical problem is a fault that always occurs whether we realize or not. Even the small disturbance may cause the failure of the system. The fault diagnosis of such devices play vital role in industry. Although the type of faults can be prevented during the design stage, they are always having possibility of system failure due to device. The needed for fault detection at an early stage is very important. This automatically will avoid total system failure which can have serious consequences. This chapter presents the introduction and basic topology to the three phase inverter and type of fault. The fault may occur in such driver system may open circuit switch, short circuit switch, intermittent misfiring and others. But, for this project, it focused on open circuit switch and short circuit switch only.

6 2.1.1 The three phase VSI topology The inverter is an electronic device or circuitry that changes direct current (dc) to alternating current (AC) [1]. It can be entirely electronic or may be a combination of mechanical effects and electronic circuitry. The input and output voltage also the frequency and overall power handling are depend on the design of the specific device. Inverters are used in applications such as adjustable-speed ac motor drives, running ac appliances from an automobile battery and others. The three phase voltage-fed inverters are recently showing growing popularity for industrial drive application. Variable voltage and frequency supply to ac drives is invariably obtained from a three-phase voltage source inverter (VSI).The three phase VSI topology shows in figure 2.1 consists with six switches and three-load phase terminals whereas a singlephase inverter has only one pair of load terminals. The current supplied to the inverter switches is referred as dc link current and has been shown asi dc, hence the power transfer is determine by relation between E dc and the magnitude and the magnitude and the polarity of the equivalent average value of e L (ѡt). Figure 2.1: The three phase VSI [5] The magnitude of dc link current usually changes in step (and sometimes its direction also changes) as the switching are turned on and off.

7 Two types of control signals can be applied to the switches: 180 conduction or 120 conduction. The 180 conduction has better utilization of the switches. For 180 conduction, three switches remain on at any instant of time. Thus two switches of the same leg are prevented from conducting simultaneously.the duration of each mode is 60 intervals and there are six modes of operation. For an example, when switch S 1 is switched on, terminal ais brought to the dc input voltage. When switch S 4 is switched on, terminal ais brought to the negative terminal of the dc source. The gating will be shifted by 60 to obtain three-phase balance. The inverter is divided with two switches, which are upper and lower switches. When the upper switch of the corresponding arm conducts, the potential of a load terminal with respect to the common reference point 0, it will result in +V. When the lower switch is conduct, it is zero. The three-position maybe synthesized by two unidirectional electronic switches. A MOSFET has a built-in body diode that serves as the path for the current from the source to the drain. However, an IGBT requires an external diode. However, there are some limitations in three phase inverter. The switches of any leg of the inverter cannot be switched on simultaneously, it will cause result in short circuit across link the dc link voltage supply. Same like when the switches of any leg of the inverter switched off simultaneously, it would result in voltage that depends on the respective line current polarity. This situation will cause undefined state thus undefined ac output line voltages. 2.1.2 Fault of the drive system The VSI is used in most of the industrial application the asynchronous machine. The switches operation failure may cause the faults in inverter. When these faults occur, the drive system has to be stopped from operation and an unprogrammed maintenance schedule.

8 There are some steps as a strategy to detect the fault in inverter:[11] a) Fault detection b) Fault identification c) Remedial action A few various types of fault can be developed in inverter. It may: [5] a) Dc link short circuit to ground b) Dc link capacitor bank short circuit c) Open circuit damage of switch. d) short-circuit damage of switch e) line to line short-circuit at machine terminal f) single line to ground fault at machine terminal Others faults also will occur inside the asynchronous machine cause by winding insulation failure due to excessive voltage or current stress. But, the ac machine faults are not considered in this project. The figure 2.2 below shows the gating signals of the inverter in an ideal case, while the switching voltage is presented in Table 2.1. Where voltage line to line: V ab = V AN V BN V bc = V BN V CN V ca = V CN V AN Figure 2.2: Gating signals of the inverter in an ideal case [2]

9 Table 2.1: Switching voltage possibilities 3 phase VSI State S1 S3 S5 V ab V bc V ca V AN V BN V CN Null 0 0 0 0 0 0 0 0 0 1 0 0 1 0 V DC V DC -1/3-1/3 2/3 2 0 1 0 V DC V DC 0-1/3 2/3-1/3 3 0 1 1 V DC 0 V DC -2/3 1/3 1/3 4 1 0 0 V DC 0 V DC 2/3-1/3-1/3 5 1 0 1 V DC V DC 0 1/3-2/3 1/3 6 1 1 0 0 V DC V DC 1/3 1/3-2/3 Null 1 1 1 0 0 0 0 0 0 2.1.2 (a) Open circuit damage of switch Focusing only on open circuit damage and short-circuit damage of switch,the open circuit damage switch may happen due to lifting ofbonding wires caused by thermic cycling[6]. An open circuit fault in VSI makes the current in phase be zero for either the positive or negative half-cycle depending on whether it occur to the upper or lower switch.[2] Figure 2.3 shows the open circuit damage of switch in upper switch of three phase inverter. C dc Figure 2.3: Open circuit damage of switch in 3 phase inverter [7]