SIGNA Explorer Lift revives our MR

Similar documents
Delivering Better Patient Care with SIGNA Architect

Liver imaging beyond expectations with Ingenia

Simultaneous Multi-Slice (Slice Accelerated) Diffusion EPI

SIGNA Architect. Make the unimaginable the expected. Issue Spotlight. Issue Spotlight

Compact yet Sophisticated

CARING DESIGN. PRACTICAL TECHNOLOGY.

MR Basics: Module 8 Image Quality

The SENSE Ghost: Field-of-View Restrictions for SENSE Imaging

Clinical Experience Using the Open Bore Multislice CT System Supria (16 slice CT) MEDIX VOL. 61 P.8 P.11

Cardiac MR. Dr John Ridgway. Leeds Teaching Hospitals NHS Trust, UK

Advanced MSK MRI Protocols at 3.0T. Garry E. Gold, M.D. Associate Professor Department of Radiology Stanford University

Pulse Sequence Design and Image Procedures

Beyond the Scan Issue Spotlight

GE Healthcare. Discovery MR T. Simply powerful. Powerfully simple.

2D, 3D CT Intervention, and CT Fluoroscopy

160-slice CT SCANNER / New Standard for the Future

The Enlightened Choice for High-field MRI

Pulse Sequence Design Made Easier

MRI Metal Artifact Reduction

Module 2. Artefacts and Imaging Optimisation for single shot methods. Content: Introduction. Phase error. Phase bandwidth. Chemical shift review

Slide 1. Slide 2. Slide 3 ACR CT Accreditation. Multi-Slice CT Artifacts and Quality Control. What are the rules or recommendations for CT QC?

TimTX TrueShape. The parallel transmit architecture of the future. Answers for life.

Surpass the unimaginable and make it the expected.

H 2 O and fat imaging

MRI Anatomy and Positioning Series Module 12: Fat Suppression Techniques

PET: New Technologies & Applications, Including Oncology

MRI Summer Course Lab 2: Gradient Echo T1 & T2* Curves

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

Wide-Detector CT for TAVR Planning:

The feasibility of breath-hold high-resolution 3D-MRCP obtained with 32 channel torso cardiac coil and T2-prepBTFE

[Maestro Class] MAGNETOM Harmony The New Degree of Perfection

Iterative Reconstruction in Image Space. Answers for life.

12/21/2016. Siemens Medical Systems Research Agreement Philips Healthcare Research Agreement AAN and ASN Committees

Works-in-Progress package Version 1.0. For the SIEMENS Magnetom. Installation and User s Guide NUMARIS/4VA21B. January 22, 2003

Instant DR in Jordan

Fundamental and Clinical Studies for Effectiveness of Zero-filling Interpolation on k-space for Improvement of Sharpness in Magnetic Resonance Imaging

3T Unlimited. ipat on MAGNETOM Allegra The Importance of ipat at 3T. medical

diagnostic examination

MR Advance Techniques. Flow Phenomena. Class II

MR Basics: Module 6 Pulse Sequences

Image quality evaluation of turbo-spin echo diffusion weighted image (TSE-DWI) : A phantom study

Maximum Performance, Minimum Space

Downloaded from by on 02/07/18 from IP address Copyright ARRS. For personal use only; all rights reserved

ISSN X CODEN (USA): PCHHAX. The role of dual spin echo in increasing resolution in diffusion weighted imaging of brain

Publication for the Philips MRI Community Issue 33 December High demand leads to second Panorama HFO purchase at KNI

Iterative Reconstruction

Going Live with the Aquilion VISION Volume 4D CT

Model Based Iterative Reconstructions represent a paradigm shift - Imaging with almost no noise

of sufficient quality and quantity

Page 1 of 9. Protocol: adult_other_adni3_study_human_ge_3t_25w_ _ _1. 3 Plane Localizer. 3 Plane Localizer PATIENT POSITION

High Field MRI: Technology, Applications, Safety, and Limitations

PET/CT Instrumentation Basics

Pitfalls and Remedies of MDCT Scanners as Quantitative Instruments

Background (~EE369B)

Authors: Cabral, Ricardo 1 ; Carvoeiras, Pedro 2 ; Fatana, João 2, ; Alves, Rita 1. 1 Centro Hospitalar Lisboa Norte - Hospital de Santa Maria; 2

Annual Ceiling Amount: $

The shortest distance to diagnosis Philips BrightView SPECT

Publication for the Philips MRI Community

nothing is more important than health

Tomosynthesis and Motion

Enhanced Functionality of High-Speed Image Processing Engine SUREengine PRO. Sharpness (spatial resolution) Graininess (noise intensity)

Compressed SENSE Speed done right. Every time.

Compressed SENSE Speed done right. Every time.

Compressed SENSE Speed done right. Every time.

MARP. MR Accreditation Program Quality Control Beyond Just the Scans and Measurements July 2005

Jordan Journal of Physics

1.5T HIGH FIELD SMALL ANIMAL MRI

Acceptance Testing of a Digital Breast Tomosynthesis Unit

Optimized CT metal artifact reduction using the Metal Deletion Technique (MDT)

TOPICS: CT Protocol Optimization over the Range of Patient Age & Size and for Different CT Scanner Types: Recommendations & Misconceptions

The Script of ZST + Presentation. MIS Upstream Marketing Team [ 日期 ]

Hardware. MRI System. MRI system Multicoil Microstrip. Part1

Image Quality and Dose. Image Quality and Dose. Image Quality and Dose Issues in MSCT. Scanner parameters affecting IQ and Dose

Detector technology in simultaneous spectral imaging

MR in RTP. MR Data for Treatment Planning: Spatial Accuracy Issues, Protocol Optimization, and Applications (Preview of TG117 Report) Acknowledgements

Maximizing clinical outcomes

MR in Tx Planning. Acknowledgements. Outline. Overview MR in RTP

DR _ solutions. We understand that customers don t need just products, they want. solutions

MRI Systems and Coil Technology

Spiral MRI on a 9.4T Vertical-bore Superconducting Magnet Using Unshielded and Self-shielded Gradient Coils

New Tec P3000. Stand: April The camera for Heartand Brain Diagnosis. The benchmark for diagnostic and technical quality.

Application Guide & Release Notes

QC by the MPE in Belgium

Gradient Spoiling. Average balanced SSFP magnetization Reduce sensitivity to off-resonance. FFE, FISP, GRASS, GRE, FAST, Field Echo

ACRIN 6686 / RTOG 0825

SIGNA Pioneer: Ultra High Efficiency Gradient System Advancing the gradient technology curve

Image Quality/Artifacts Frequency (MHz)

NIH Public Access Author Manuscript Int J Cardiovasc Imaging. Author manuscript; available in PMC 2008 May 26.

Clear delineation of optic radiation and very small vessels using phase difference enhanced imaging (PADRE)

SAFIRE. Sinogram Affirmed Iterative Reconstruction. Answers for life.

MUSICA Nerve Center. Artificial Intelligence. Intelligent tools for your Digital Radiography workflow. Fluoroscopy. Workflow Optimization

Weber State University Radiologic Technology 4603

Welcome at MR Achieva 3.0T TX. About the system. Index. 1.1 Introduction

ADVANCED MEDICAL SYSTEMS PTE LTD Singapore Malaysia India Australia

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

BOLD fmri: signal source, data acquisition, and interpretation

Magnetic Resonance Imaging Principles, Methods, and Techniques

Yinsheng Li 1, Peter Bannas 2, M.D., Perry Pickhardt M.D. 2, Meghan Lubner M.D. 2, Ke Li Ph.D. 1,2, and Guang-Hong Chen Ph.D. 1,2

The Point Source. July 2011 Volume 2, Issue 1. Executive message. Rich Fabian. In this issue

Magnetic Resonance Imaging

Transcription:

Seiji Shiotani, MD, PhD Seirei Fuji Hospital in Fuji City, Shizuoka, Japan Masayoshi Sugimura Seirei Fuji Hospital in Fuji City, Shizuoka, Japan SIGN Explorer Lift revives our MR The clinical usefulness and economic advantage of SIGN Explorer Lift y Seiji Shiotani, MD, PhD, Chief Radiologist, Department of Radiology, and Masayoshi Sugimura, Chief Radiation Technologist, Keiaikai General Incorporated Foundation, Seirei Fuji Hospital, Fuji City, Shizuoka, Japan In 2025, it is predicted that one in three Japanese citizens will be over 65 years old and one in five will be over 75 years old. This age shift will drastically change the medical environment for our 151-bed hospital. While small in size, Seirei Fuji Hospital contributes significantly to regional medical care by enhancing advanced capabilities and strengthening cooperation with other regional medical facilities. lthough our hospital is advanced in many areas across the prefecture, our 2001 MR system was somewhat obsolete. Due to the system s age, we often had breathing artifacts around the chest area due to long scan times and the lack of motion correction techniques, which hampered our diagnosis. We also could not perform upper abdominal scans (Liver, MRCP) in a wide range, so we had to scan the abdomen separately in three stations: upper, middle and lower. This made it very difficult to interpret the images for a diagnosis because each series was reconstructed separately, and this was most pronounced when the radiologist was reading remotely. Particularly problematic were patients with unstable breathing as the breathhold would appear completely different in each series, making it very difficult to ascertain the continuity of each station. The system had additional shortcomings as well. MR brain and spine exams did not have sufficient image quality for our referring physicians (Figures 1 and 2). Finally, our radiology staff would attend academic meetings and sessions to learn the latest techniques, but could not utilize that learning back at the hospital due to our system s outdated technology. We were convinced that the above issues could be solved by investing in a new MR system. On the other hand, we were concerned about the cost. Fortunately, we learned it was possible to upgrade 1 our MR to the latest model, SIGN Explorer, by replacing all components other than the magnet with SIGN Explorer Lift. gehealthcare.com/mr 42 Tomorrow Today

In Practice Figure 1. 70-year-old suffering from transient ischemic attack. Comparison of brain DWI images () before and () after SIGN Explorer Lift. In Figure 1, the SNR is significantly improved and brain structures are more clearly visualized than Figure 1. Figure 2. n 80-year-old with back pain. Comparing the lumber spine T2w images () before SIGN Explorer Lift and () after SIGN Explorer Lift, it is clear the vertebral body structures are distinctly visualized. The upgrade contributed to image quality improvement and motion artifact reduction as a result of shortened scan times and higher SNR through the Posterior rray Coil improvement. The main objective of upgrading our MR was to improve image quality. We visited another site that had recently upgraded and compared images to another recently installed (new) SIGN Explorer and found them to be comparable. We therefore chose the SIGN Explorer Lift with confidence. The cost was also lower since the magnet did not need to be replaced, making the downtime for the upgrade significantly less. fter the upgrade SIGN Explorer Lift significantly improved the performance and image quality of our MR exams and shortened exam times. We could now provide a patient-friendly MR scan and immediately accept emergency patients. The scan time reduction enabled an increase in the number of patients in a day, providing an economic benefit to our hospital. efore the upgrade, we performed an average of 240 exams/month operating five days each week; now we increased that number to approximately 300 exams/ month in the same operating time. key reason for the increase in the number of examinations is the system s image quality and clinical capability, further increasing referrals from local physicians. gesignapulse.com 43 utumn 2017

Figure 3. Comparison of MRCP images between respiratory synchronization scan and breath-hold scan. Depending on the patient, we can choose either () respiratory synchronization scan or () breath-hold scan. In our case, we expect to realize a return on our investment within three years, including human resources and maintenance expenses. With the broader range of clinical capabilities, our staff is now motivated to improve their knowledge and skills. dvanced clinical capabilities With the prior system, we scanned MRCP using 2D Fast Spin Echo (FSE). The newly upgraded SIGN Explorer allows us to perform 3D Fast Recovery FSE (frfse) combined with SSET parallel imaging. We reviewed 40 MRCP cases: 20 gallstone cholecystitis, 11 pancreatic neoplastic lesion and 9 other cases. The 18 male and 22 female patients were an average age of 65.8 years (maximum 85 and minimum 36 years). ll cases were scanned with respiratory synchronization, although MRCP can be acquired with diaphragm synchronization. The use of uto Navigator was reported to improve the image quality. Using the 3D frfse acquisition, it is possible to acquire higher signal with shorter TRs due to Fast Recovery. y using SSET, it is possible to reduce the echo train of FSE, which helps to reduce blurring due to T2 attenuation. In addition, with 3D imaging we can view the data in various planes and angles. Furthermore, both respiratory synchronization and diaphragm synchronization are available. Our evaluation reported 27 cases as "very good," 10 cases were "rescan not necessary," and only three cases required rescans. For the cases rescanned, 3D frfse was again used under breath-hold but with increased slice thickness. Since 3D frfse collects in-phase data with single shot, it is necessary to decrease the number of slices or shorten TR to achieve scan time reduction. Increasing slice thickness will lower the resolution but improve SNR. Shortening TR causes lower SNR even if fast recovery is used. Considering these points, our hospital optimizes the protocols based on slice thickness, the number of slices and TR to keep breath-hold times less than 25 seconds (Figure 3). gehealthcare.com/mr 44 Tomorrow Today

In Practice C Figure 4. Image comparison of T1w () before and (, C) after upgrade. () Prior to upgrade, breath-hold T1w 2D FSPGR FatSat. fter the upgrade, we are using a () breath-hold T1w LV Flex FatSat. (Water) and (C) breath-hold T1w LV Flex (in-phase). We can make the slices thinner using LV Flex, so the vessels in the liver can be observed without partial volume effect. LV Flex With the upgrade, we can now use LV Flex for T1-weighted (T1w) imaging. LV Flex, a 3D acquisition, uses a 2-point Dixon method. fter collecting data in-phase and out-ofphase, the sequence estimates whether the signals are water dominant or fat dominant with reference to certain pixel data. It then calculates magnetic field inhomogeneity of all pixels from neighboring pixels. y identifying the signal intensity of each pixel from the results, it is possible to calculate a uniform water image (fat separation image) and fat image (water separation image). There are several advantages to using LV Flex, including thinner slices with 3D imaging, robust fat separation and acquiring both with/without fat separation images in one acquisition. We can scan the same area on the patient with gapless 3.2 mm slice thickness in one breath-hold using LV Flex and obtain both with/without fat separation images (Figure 4). Most importantly, these sequences help us address the problem of a patient who cannot hold their breath to acquire the imaging data. In these cases with the prior scanner, we often sacrificed image resolution to shorten breath-hold time by optimizing slice thickness or using phase-encoding to shorten breath-hold time. However, SIGN Explorer is compatible with uto Navigator and includes uto Navigator-gating, which enables the acquisition of 3D T1-weighted images with free breathing. y performing LV Flex in conjunction with uto Navigator-gating, it is possible to scan 3D T1-weighted images both with and without fat separation on patients who cannot hold their breath (Figure 5). gesignapulse.com 45 utumn 2017

C D Figure 5. The effect of uto Navigatorgating in a LV Flex acquisition. (, C) reath-holding failure occurred at hepatocyte phase scan with Primovist EO and we rescanned it with (, D) uto Navigator-gating, which can be used in any plane. lur conspicuous in () and (C) was improved with the use of uto Navigator-gating. Parallel imaging Conventionally, the SSET parallel imaging method has been used to shorten scan time. It can also be used to reduce aliasing artifacts. Theoretically, it is a parallel imaging method that reduces the acquisition time by decimating the amount of data sampling. Typically, if the data sampling amount is decimated then aliasing artifacts appear. ut with SSET we can obtain images without aliasing artifacts due to the signal strength of the wrapped-around part by calculation. If we utilize this calculation to the general aliasing artifact images (smaller FOV scan than subject), we can obtain non-aliasing artifact images by setting the SSET reduction factor to one. Generally we utilize No-phase Wrap (NPW) to eliminate aliasing artifacts. NPW is a technique used to solve the artifact by oversampling so the scan time gets longer. Even in such cases, it is possible to acquire non-aliasing artifact images without extending scan time by using SSET. Using LV Flex, it is possible to acquire a higher quality image without non-aliasing artifact and without a penalty in scan time. Conclusion Just one month after the upgrade, our hospital recorded its highest patient volume for MR imaging. With SIGN Explorer Lift, we have the latest imaging techniques at a fraction of the cost. key clinical benefit for our patients and economic advantage for our hospital is that we can improve image quality without extending scan time. SIGN Explorer Lift is a good solution for facilities seeking to improve clinical image quality in an economic way. Footnotes 1. In the upgrade process, the existing magnet remains and all other components are replaced. fter upgrading, the regulatory name and the number of the product will be changed. gehealthcare.com/mr 46 Tomorrow Today