Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 000000000 Providing exceptional customer service since 9 U Rack Mountable Control and Monitor Unit MEAN WELL RKP-CMU Series File Name:RKP-CMU-SPEC 0-0-...9
Providing exceptional customer service since 9 U Rack Mountable Control and Monitor Unit MEAN WELL RKP-CMU Series SPECIFICATION MODEL RKP-CMU RKP-U -CMU DIGITAL METER Display the DC output voltage, current, and internal temperature of each RCP-000 unit OUTPUT CONTROL OUTPUT PMBus signal for each RCP-000 unit LED INDICATOR Green: Power on Red:Alarm RELAY CONTACT user programmable relay, relay contact rating(max.): 0V/A resistive VOLTAGE RANGE Note. ~ VDC INPUT CURRENT A/VDC 0.A/VDC MONITORING INPUTS PMBus signal for each RCP-000 unit DISPLAY LCD x Alphanumeric Matrix Display / PC Web Page Display FUNCTION MONITOR Output Voltage / Load Current / Temperature / Input Voltage CONTROL Output Voltage, Current Limit, ON/OFF COMM. INTERFACE USB, RS-, WORKING TEMP. Note. - ~ +0 ENVIRONMENT WORKING HUMIDITY 0 ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -0 ~ +, 0 ~ 9% RH non-condensing VIBRATION 0 ~ 00Hz, G 0min./cycle, 0min. each along X, Y, Z axes SAFETY STANDARDS Design refer to TUV EN090- UL090-, TUV EN090- approved SAFETY & EMC (Note ) OTHERS NOTE WITHSTAND VOLTAGE Note. O/P-FG:0.KVDC I/P-O/P:KVAC I/P-FG:KVAC O/P-FG:0.KVDC ISOLATION RESISTANCE Note. O/P-FG:00M Ohms / 00VDC / / 0% RH I/P-O/P, I/P-FG,O/P-FG:00M Ohms / 00VDC / / 0% RH EMC EMISSION Compliance to EN0 (CISPR) Conduction Class B, Radiation Class A ; EN000--,- EMC IMMUNITY Compliance to EN000--,,,,,,, EN000--(EN00-), light industry level, criteria A MTBF 0.K hrs min. MIL-HDBK-F ( ) DIMENSION.**mm (L*W*H).*0.*mm (L*W*H) PACKING 0.Kg; pcs/.kg/0.9cuft.kg; pcs/.kg/.cuft File Name:RKP-CMU-SPEC 0-0-...9
U Rack Mountable Control and Monitor Unit MEAN WELL RKP-CMU Series Providing exceptional customer service since 9 Manual.Communication interface RKP-CMU can control and monitor RCP-000 parameter via PMBus communication, and PC can manage the whole system by using USB, RS, or to connect to RKP-CMU. PMBus: RKP-CMU supports PMBus Rev.. with maximum 00KHz bus speed, allowing information reading, status monitoring and output trimming. For details, please refer to the Installation Manual. USB PMBus RS-.RCP-000 Monitoring and control RKP-CMU can monitor parameter of RCP-000 such as output voltage, output current, internal temperature, status, serial number, and firmware version. It also can turn RCP-000 on/off together or separately by using "ON/OFF" pin in CN00 or PMBus "CONTROL" pin in JK or PMBus "OPERATION" command, shows below. By using PMBus, output voltage and over load protection of RCP-000 are adjustable. Please refer to the Installation Manual..Real time clock, Data Log and Event Log RKP-CMU has a build-in real time clock data to display actual date/time and for log time stamp. The data logger is designed to store operating data when the systems works. It has 000 recodes and the interval of log is programmable from to 0 minutes. The event log store system condition when alarm occur and remove. There are 00 records in event log..programmable relay There are relays and each relay has normal open, normal close and common contact in terminal block. Their active conditions are programmable for flexible application, like charger and generator control. Sub-function PSU Parameter Alarm.Any alarm.ovp.olp.short circuit.otp.high Temperature.AC fail.fan lock 9.PMBus error PSU ON.Immediately.Delay PSU0~ 0 sec. ~ 00 sec. PSU OFF.Immediately.Delay PSU0~ 0 sec. ~ 00 sec. Digital input D-IN ~ D-IN File Name:RKP-CMU-SPEC 0-0-...9
U Rack Mountable Control and Monitor Unit Providing exceptional customer service since 9 U Rack Mountable Control and Monitor Unit MEAN WELL RKP-CMU Series Mechanical Specification (Single Unit) Case No. 99A Unit:mm. JK 0.9 CN0 JK00 CN0 RS- -M L=mm Fig DC IN RY RY RY RY TB SK00 0.9 -M L=mm 0.9 RKP-CMU 9 -M L=mm BOTTOM VIEW Mounting Instruction Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque M mm ~ Kgf-cm Mounting Surface Mounting Screw L Chassis of RKP-CMU File Name:RKP-CMU-SPEC 0-0-...9
Providing exceptional customer service since 9 U Rack Mountable Control and Monitor Unit U Rack Mountable Control and Monitor Unit MEAN WELL RKP-CMU Series RKP-CMU Mechanical Specification (Rack System) Case No. 99D Unit:mm Fig Fig CN00 SK00 TB RKP-UT-CMU B A _ + Fig 0. 0. RKP-UI-CMU Mounting Bracket JK IN DC JK DC RY RY RY IN RY N FG L N FG L JK00 CN0 CN0 RS- CN00 SK00 TB RS- RY RY RY RY + _ A B IEC0-C0 IEC0-C0 0 JK00 CN0 CN0 0 -M L=mm 0. SVR SVR -M L=mm 0 Air flow direction Module B Module A. 0. 9. DC OK DC OK... File Name:RKP-CMU-SPEC 0-0-...9
Providing exceptional customer service since 9 U Rack Mountable Control and Monitor Unit MEAN WELL RKP-CMU Series IN/OUT Connector Assignment( CN00) : D-Type Right Angle positions,,,9,0,, ON/OFF AC-OK DC-OK PV T-ALARM FAN FAIL Each unit can separately turn the output on and off by electrical signal or dry contact between ON/OFF A,B(pin,) and +V-AUX(pin ). Short: ON, Open:OFF. (Note.) Low : When the input voltage is Vrms. High : when the input voltage in Vrms. (Note.) High : When the Vout 0± %. Low : When Vout 0± %. (Note.) Connection for output voltage trimming. The voltage can be trimmed within its defined range. (Note.) High : When the internal temperature (TSW or TSW open) exceeds the limit of temperature alarm. Low : When the internal temperature (TSW or TSW short) under the limit temperature. (Note.) High : When the internal fan fail. Low : When the internal fan is normal. (Note.) +V-AUX Auxiliary voltage output,. ~.V, referenced to GND- AUX (pin ). The maximum load current is 0.A. This output has the built-in "Oring diodes" and is not controlled by the remote ON/OFF control. +V-AUX Auxiliary voltage output, 0. ~.V, referenced to GND- AUX (pin ). The maximum load current is 0.A. This output has the built-in "Oring diodes" and is not controlled by the remote ON/OFF control. ~ GND-AUX N.C. +S -S +V(signal) -V(signal) Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V). Not used. Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.V. Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.V. Positive output voltage. For local sense use only, can't be connected directly to the load. Negative output voltage. For local sense use only, can't be connected directly to the load. IN/OUT Connector Assignment( JK) : RJ positions, DA,DB -V(signal) CONTROL NC SDA Differential digital signal for parallel control. (Note.) Negative output voltage. For parallel control, can't be connected directly to the load. Remote ON/OFF control pin used in the PMBus interface. (Note.) Not use. Serial Data used in the PMBus interface. (Note.) SCL GND-AUX Serial Clock used in the PMBus interface. (Note.) Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V). Note.: Non-isolated signal, referenced to -V(signal). Note.: Isolated signal, referenced to GND-AUX. IN/OUT Connector Assignment( CN0) : D-type Male 9 positions,,,,,9 NC RXD TXD GND-FG Not used. Data receiving pin of RS- interface. Data transmitting pin of RS- interface. RS- common GND. This signal connects to FG and isolated from -V and GND-AUX. IN/OUT Connector Assignment( CN0) : HRS DF-DP-DS or equivalent,,,,,, D-IN D-IN D-IN D-IN GND-FG The isolated digital input signal and referenced to GND-FG. Open from GND-FG or +V : Logic "" input to RKP-CMU short to GND-FG or 0V : Logic "0" input to RKP-CMU Common GND for D-IN. This signal connects to FG and isolated from -V and GND-AUX. IN/OUT Connector Assignment( JK00) : RJ position,,,,, TX+/TX- RX+/RX- NC Transmit data used in the interface. Receive data used in the interface. Not used. File Name:RKP-CMU-SPEC 0-0-...9
U Rack Mountable Control and Monitor Unit MEAN WELL RKP-CMU Series Providing exceptional customer service since 9 IN/OUT Connector Assignment( TB) : DECA MX- or equivalent,,,0,,,,,9, Relay-NO Relay-NC Relay-COM Normal-open contact of programmable relay. Normal-close contact of programmable relay. Common for NO/NC contact. Note: Relay contact rating (max.) : 0Vdc/A resistive. IN/OUT Connector Assignment(SK00): Schurter 0.0 or equivalent +VIN -VIN Positive input voltage for RKP-CMU. Negative input voltage for RKP-CMU. File Name:RKP-CMU-SPEC 0-0-...9