Transformer differential protection

Similar documents
Harmonic restraint earth fault or single-phase overcurrent protection

Transformer and generator time-overexcitation relay and protection assemblies RXLK 2H and RALK

Transformer differential protection RADSB

Time over/underfrequency relay with protection assemblies

)HDWXUHV Voltage restraint overcurrent stage with five different inverse or definite time characteristics

Modular multifunction generator protection

Time-overcurrent relays and protection assemblies

Time relay RXKA 1. (xx jpg) RXKA 1

Compact current relay and protection assemblies RXHL 401 and RAHL 401

Current and voltage measuring relays RXIK 1, RXEEB 1 and RXIB 24

Phase and neutral overcurrent protection

Stabilized Differential Relay SPAD 346. Product Guide

Earth fault protection for isolated neutral systems with frequency converters

RARIC Shaft current protection

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

RXFK 2H and RAFK Time over/underfrequency relay and protection assemblies

SPAD 346 C Stabilized differential relay

Overcurrent Protection / 7SJ45

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

SPAE 010, 011 High Impedance Protection Relay

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

Transformer Protection Principles

INDICATOR TYPE RXSK 2H

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

Transformer protection IED RET 670

Type CP-S, CP-C & CP-A Switch mode

PD300. Transformer, generator and motor protection Data sheet

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique

SPECIFICATION FOR OVERCURRENT RELAYS

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

XD1-T - Transformer differential protection relay

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

Modern transformer relays include a comprehensive set of protective elements to protect transformers from faults and abnormal operating conditions

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Three-phase monitoring relays

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

LINAX 4000L Continuous-line recorder

XD1-T Transformer differential protection relay. Manual XD1-T (Revision A)

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

IRI1-ER - Stabilized Earth Fault Current Relay

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

QUINT-PS/ 3AC/24DC/10

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Type: ADR233A (ADITYA V2 Series) (Preliminary) ASHIDA Numerical 3 Phase Tx. Differential Protection Relay

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

Analog signal converters CC-E I/I

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

POINTAX 6000L2 Point Recorder

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

RAIDK, RAIDG, RAPDK and RACIK Phase overcurrent and earth-fault protection assemblies based on single phase measuring elements

Digital Grid Products. SICAM Fault Sensor Indicator (FSI) The Guardian for your Overhead Line Networks

presentation contents application advantages

Railway application RER670 Version 2.2 IEC Type test certificate R E L I O N 670 SERIES

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Electronic timer CT-TGD.22

QUINT-PS/ 1AC/24DC/20

Three-phase monitoring relay

Three-phase monitoring relay

N. TEST TEST DESCRIPTION

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

1 INTRODUCTION ORDER CODE / INFORMATION

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Solid-state Timer H3DS

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

Power supply CP-E 24/0.75

Technical features table for miniature circuit-breakers SH 200 Series

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Power supply CP-E 24/2.5

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

N. TEST TEST DESCRIPTION

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Power supply CP-T 24/20.0 Primary switch mode power supply

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

24 V DC, 12 W output 12 V DC, 12 W output 24 V DC, 36 W output

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Transcription:

Transformer differential protection Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE970883) Features Three phase differential protection with two, three, five or six through-current restraint inputs Complete phase and earth fault protection A high voltage cable, length up to about two km, can be included in the differential zone Harmonic restrained operate time approx. 30 ms at 3 times pick-up current Unrestrained operate time 10-20 ms at 2 times pick-up current with minimum impulse time of 3 ms Variable percentage restraint for external fault security, even at use of on-load tapchanger Second harmonic restraint from all three phases for inrush security Fifth harmonic restraint from all three phases for overexcitation security Sensitivity can be set to 20, 25, 35 or 50 per- cent of rated current, 1 A or 5 A Unrestrained operation settable to 8, 13 or 20 times relay rated current Provided with separate interposing CT s for ratio and phase angle matching and equalizing of zero sequence current Long CT secondary leads are feasible with 1 A relay Built-in trip relay, indicator and test switch Type SLCE interposing current transformers: Secondary current 1 A or 5 A Three different ranges of ratios reconnectible in steps of 4 to 6%: - 0,65-2,60/1 A - 2,55-10,1/1 A - 2,85-11,2/5 A Fixed ratio with or without equalizing winding available on request Available as single-phase units and threephase sets Application The is a protective relay intended for all types of three-phase power transformers. By including additional input restraint modules, up to 6 transformer windings or restraining inputs can be connected. The relay is also well suited for generator and step-up transformer overall protection, often including the auxiliary transformer in the protected zone. The non-linear percentage restraint characteristic provides the required restraint for external faults. This makes the relay suitable for use with multi-winding transformers, autotransformers or in a system where one transformer winding is directly connected to two

Page 2 Application (cont d) or more breakers. The characteristics are designed to provide excellent internal fault sensitivity. The relay also has an unrestrained instantaneous function which responds to the total differential current (less any dc component).this will provide redundant operation for severe internal faults. The restraining voltages from the second and fifth harmonic filters for each phase are paralleled and the result used for harmonic restraint for each phase. The polyphase harmonic restraint circuitry prevents the relay from operating on inrush currents yet has a minimum effect on relay sensitivity if an internal fault occurs during energizing. The fifth harmonic is used to prevent operation of the relay due to possible overexcitation of the transformer. Overexcitation protection should be provided by a delayed V/Hz relay e.g. type RATUB which has an inverse-time operating characteristic. Interposing CT s are used to balance the main CT ratios. In addition, interposing CT s may be used to reduce the effective lead burden of long secondary leads. The differential zone of the relay can include up to about two kilometers of high voltage cable, since adequate filtering provides security against high current oscillations. In such a case, the current in the CT circuit is reduced by specific interposing CTs. (96000200) Fig. 1 Application examples for the transformer different relay Design The relay is available with two, three, five or six through-current restraint inputs, and can be used for dual-winding or multi-winding transformers which have one or more circuit-breaker for each winding. The relay is built up of the following modules: Test switch, type RTXP 18 Dc-dc converter, type RXTUG 22H Transformer units, type RTQTB 060 and 061 Measuring unit, type RXDSB 4 Tripping relay, type or RXME 18 Indicator, type RXSGA 1 or flag indicator relay, type RXSF 1 In versions with an indicator, LED s indicate unrestrained operation and restrained operation and also the phase which caused the latter operation. In versions with a flag relay, a red flag becomes visible when the differential relay operates. All versions are listed in the ordering table. The relay can be connected directly to the main current transformers; however, when this is not practical, interposing CT s are used for ratio and phase-angle matching purposes. Interposing CT s provide an additional point of insulation so that different sets of main CT s can be earthed independently of each other. In the case of long CT leads, interposing current transformers can be used to reduce the secondary CT lead burden to the relay (use of 1 A relay is advantageous). When internal faults such as short-circuits between phases, earth faults or inter-turn short-circuits occur, the differential relay rapidly initiates disconnection of the supply to the transformer. On the other hand, the is stable for differential currents

Page 3 which are caused by external faults, inrush currents or overvoltages. The operate values for restrained and unrestrained operation are set with switches on the measuring unit. The operate times of the relay are shown in Fig. 2. has static measuring circuits with active filters to enable optimum utilization of the harmonics in the differential current while restraining inrush currents and overvoltages. The restraint limits in the case of external faults are shown in Fig. 3. Operate time in ms 60 50 40 Restrained operation (Ι ) sr 30 20 Unrestrained operation (Ι ) su 10 0 1 1,5 2 3 4 5 6 7 8 910 20 Differential current Ι d in multiples of the set operating value Ι sr and Ιsu (96000201) Fig. 2 Operate times for restrained and unrestrained operation, with as the tripping relay Differential current Ι d in multiples of rated current Ι r a) Ι d b) Ι sr = 0,35 x Ι r Ι sr = 0,20-0,50 x Ι r 10 a) b) 8 6 Operation 4 2 Non-operation Ι x + Ι y 2 2 4 6 8 10 12 14 16 Restraint through current in multiples of rated current Ι r (96000202) Fig. 3 The restraint characteristic for external faults is variable and is adapted to the magnitude of the through current (I x +I y )/2 where I x and I y are the highest incoming and out-going currents, respectively, of the transformer

Page 4 Design (cont d) Type SLCE interposing current transformers: The reconnectible SLCE 12 has three secondary windings connected to a terminal block with six terminals, marked 1 to 6, and two primary windings with intermediate taps connected to a terminal block with six terminals, marked 7 to 12. The transformer also has a third terminal block with terminals marked P1-P2, S1-S2 to which external connections are to be made. By means of different connections of the primary and secondary windings, a large number of current ratios is obtained. If, however, SLCE 12 is ordered with a specific ratio, it will be delivered connected and marked for this ratio. The transformer can be obtained as singlephase units or in a three-phase set with three transformers mounted on an apparatus plate for 19 rack mounting. The set includes a terminal block X1, marked 1 to 12, to which external connections are to be made. Internal connections between the terminal block and the primary and secondary terminals of the transformers are made before delivery. (90142) (96000204) (96000203) Fig. 5 Terminal markings of the three-phase set with 3 SLCE 12 Fig. 4 Terminal markings of separate SLCE 12

Page 5 Technical data Table 1: Rated and operate values Rated current, I r Rated frequency, f r Restrained operate value, I sr 1 or 5 A 50-60 Hz Settable 0,20, 0,25, 0,35 and 0,50 x I r Unrestrained high speed operate value, I su Settable 8, 13 and 20 x I r Restraining limit values: Energizing Overvoltage External faults 2:nd harmonic = 17% of the fundamental 5:th harmonic = 38% of the fundamental Acc. to curves in Fig. 3 Operate time: (see Fig. 2) RXME 18 I d = 3 I sr approx. 30 ms approx. 60 ms I d = 2 I su 10-20 ms approx. 40 ms Overload capacity: I r = 1 A I r = 5 A continuously 10 A 20 A 1 s 100 A 250 A Permitted ambient temperature -25 C to +55 C Auxiliary voltage, EL 24-250 V dc +10%, -20% Power consumption: Restraint circuit Differential circuit Auxiliary circuit normal service operation Dimensions and weight SLCE 12, standard version Rated secondary current, I r Current ratios approx. 0,025 VA/phase at I r = 1 A approx. 0,25 VA/phase at I r = 5 A approx. 0,025 VA/phase at I r = 1 A approx. 0,25 VA/phase at I r = 5 A approx. 7 W approx. 11 W See Ordering, Table 6: selection 1 or 5 A Reconnectible in 4-6% steps 0,65-2,60/1 A 2,55-10,1/1 A 2,85-11,2/5 A Rated frequency, f r 50-60 Hz Rated output 1,5 VA 2,5 VA Accuracy class 10 P 10 P Accuracy limit factor 30 20 Remanence factor (max. remaining flux density in multiples of the saturation flux density) Overload capacity: continuously 10 s 1 s 0,2 2,5 I r 15 I r 75 I r Power consumption 1,0-2,8 VA depending on selected ratio Permitted ambient temperature -20 C to +55 C Max. external conductor area 10 mm 2 Weight: single-phase unit 3-phase unit 3,6 kg approx. 12 kg

Page 6 Technical data (cont d) Table 2: Insulation tests (IEC 255-5) Dielectric tests current circuits 2,5 kv, 50 Hz,1 min other circuits 2,0 kv, 50 Hz,1 min Impulse voltage test 5,0 kv, 1,2/50 µs, 0,5 J SLCE 12 Dielectric tests between primary and secondary windings and to exposed conductive parts 2,5 kv, 50 Hz,1 min Table 3: Electromagnetic compatibility tests Power frequency test (SS 436 15 03) 0,5 kv, class PL4 Fast transient test (SS 436 15 03) 4-8 kv, class PL 4 1 MHz burst test (IEC 255-22-1) 2,5 kv, class III Electrostatic test (IEC 255-22-2) contact discharge air discharge Radiated electromagnetic field test (IEC 1000-4-3) Conducted electromagnetic test (IEC 1000-4-6) Fast transient test (IEC 255-22-4) Electromagnetic emission test (EN 55 011) 6 kv, class III 8 kv, class III 10 V/m, 26-1000 MHz, class III 10 V 0,15-80 MHz 4 kv, class IV 0,15-100 MHz, class A Table 4: Mechanical tests Vibration tests (IEC 255-21-1) response test endurance test Shock tests (IEC 255-21-2) response test withstand test Bump test (IEC 255-21-2) 0,075 mm/1 g, 10-150 Hz, class II 2 g, 10-150 Hz, 20 sweeps, class II 5 g, 11 ms, 3 pulses, class I 15 g, 11 ms, 3 pulses, class I 10 g, 16 ms, 1000 pulses, class I

Page 7 Table 5: Contact data RXME 18 RXSF 1 RXSGA 1 RXTUG 22H Highest system voltage DC/AC 300/250 V 450/400 V 300/250 V 250/250 V Current carrying capacity continuously during 1 s Making and conducting capacity during 0,2 s during 1 s Breaking capacity ac, cos ϕ > 0,4, 250 V dc, L/R, < 40 ms 48 V 110 V 220 V 4 A 20 A 30 A 10 A 10 A 1,2 A 0,3 A 0,15 A 6 A 30 A 30 A 20 A 20 A 18 A 3 A 1 A 5 A 50 A 30 A 10 A 10 A 1,5 A 0,4 A 0,2 A 5 A 15 A 30 A 10 A 8 A 1 A 0,4 A 0,2 A Diagrams TRIPPING ETC. ALARM ETC. LOSS OF EL 7454 356-CC,-DC 3Id 1 3Id/I 101 17A 16A 15A 137:15 107:316 107:318 - U - + - 101 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A L1 L2 L3 L1 L2 L3 L1 L2 L3 N 3Id/I> 101 107 113 119 125 137 101 RTXP 18 107 RXTUG 22H 113 RTQTB 060 119 RTQTB 061 125 RXDSB 4 137 337 RXSGA 1 42C 337 4U 107:116 107:118 107:317 101 2A 137:12 137:24 101 1A 18A 14A + - + + + + + - EL Fig. 6 Variant with 3 restraint inputs and tripping relay type Terminal diagram No. 7454 356-DBA

Page 8 Diagrams (cont d) (96000205) SLCE 12 19" 482 mm X1 T1 T2 T3 Terminal block 4U 177 mm (96000206) Fig. 7 SLCE 12 and apparatus with 3 SLCE 12. Dimensions in mm Ordering Specify: Quantity Ordering No. (from Table 6: selection) Rated current, I r Rated frequency, f r Options: Interposing CT s (see Table 7: Interposing CT selection) Three-phase auxiliary CT set mounted on a 4U 19 apparatus plate with terminal block Desired wording on the lower half of the test switch face plate max. 13 lines with 14 characters per line. Type SLCE interposing current transformers: Type SLCE 12 or 16 (alt. three-phase set with 3 SLCE 12) Quantity Ordering No. (from Table 7: Interposing CT selection) Desired ratio connected (factory setting) Mounting: is delivered on apparatus bars. When additional mounting is required use a 4U equipment frame for 19 rack mounting or a type RHGX 12 or 20 case for panel mounting. For installation and connection material see Accessories (COMBIFLEX connection and installation) and Mounting system sections of the catalogue.

Page 9 Table 6: selection No. of restraint inputs two two two two three three five five Type of tripping relay Indicator Flag relay Dimensions Weight RXME 18 RXSGA 1 RXSGA 1 RXSGA 1 (RXME 18) RXSF 1 RXSF 1 RXSF 1 4U 60C 4U 60C 6 kg 6 kg 6 kg 6 kg 9 kg 9 kg 11 kg 11 kg Circuit/ Terminal diagram 7454 344-AE/ 7454 344-ADA 7454 344-BE/ 7454 344-BDA 7454 344-CE/ 7454 344-ADA 7454 344-EB/ 7454 344-EAA 7454 356-CC/ 7454 356-DBA 7454 356-DC/ 7454 356-DBA 7454 359-CC/ 7454 359-DBA 7454 359-DC/ 7454 359-DBA six RXSGA 1 4U 60C 13 kg 7454 361-CB/ 7454 361-CBA Ordering No. RK 625 001-AC RK 625 001-BC RK 625 001-CC RK 625 001-EA RK 625 005-CA RK 625 005-DA RK 625 006-CA RK 625 006-DA RK 625 010-CA Table 7: Interposing CT selection Ratio Type Reconnectible standard design: 0,65-2,60 A/1 A 2,55-10,1 A/1 A 2,85-11,2 A/5 A SLCE 12 SLCE 12 SLCE 12 With equalizing winding (D-connected). One ratio. Please specify the SLCE 12 ratio Ordering No. Single-phase units 4785 040-VP 4785 040-VR 4785 040-VS Ordering No. Three-phase set on plate RK 795 104-AA RK 795 104-AA RK 795 104-AA RK 795 104-BA Without equalizing winding. Order specific fixed ratio. Please specify the ratio SLCE 12 RK 795 104-CA For long CT circuits: 5/0,4 A 1/0,4 A 0,4/1 A 0,4/5 A SLCE 16/350 SLCE 16/350 SLCE 12/200 SLCE 12/200 4785 040-ATL 4785 040-AUA 4785 040-AUB 4785 040-AUC

Page 10 References User s Guide Calculation and connection guide for interposing transformers Power transformer protection Application Guide Auxiliary relays, RXME 18 and signal relay RXSF 1 DC-DC converter RXTUG 22H Test system COMBITEST COMBIFLEX connection and installation components Relay mounting systems Dimensions 1MDU04007-EN AG03-5005E 1MRK 508 015-BEN 1MRK 513 001-BEN 1MRK 512 001-BEN 1MRK 513 003-BEN 1MRK 514 001-BEN 1MRK 514 004-BEN Manufacturer ABB Automation Products AB Substation Automation Division SE-721 59 Västerås Sweden Tel: +46 (0) 21 34 20 00 Fax: +46 (0) 21 14 69 18