TAPPI Extrusion Coating Short Course 2010 Charleston, SC

Similar documents
Solutions for Lithium Ion Battery Manufacturing

LITHIUM ION BATTERY WEB GAUGING APPLICATIONS

Online Gauging As We Know It! by Udo Skarke Erhardt-Leimer Inc.

New On-Line Measurement and Control of Multilayer Blown Films

Hot Melt Pressure Sensitive Adhesives Benefit From Near Infrared (NIR) Measurements Throughout

On-line measurement of silicone release coating on paper substrates using a scanning industrial spectrometer

FOR 353: Air Photo Interpretation and Photogrammetry. Lecture 2. Electromagnetic Energy/Camera and Film characteristics

High Performance Thin Film Optical Coatings Technical Reference Document 09/13. Coatings Capabilities. Heat Control - Hot Mirror Filters

Chapter 16 Light Waves and Color

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Physics Laboratory Scattering of Photons from Electrons: Compton Scattering

Web gauging solutions

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Gamma Spectrometer Initial Project Proposal

Term Info Picture. A wave that has both electric and magnetic fields. They travel through empty space (a vacuum).

USING NIR MOISTURE SENSORS TO IMPROVE DRYER PERFORMANCE

NDC Infrared Engineering X-Ray Tranflectance (XRTF) Project EPA pilot demonstration on technology EP05WO May 2006 Bo Franklin/Terry Bates

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

New In Process Coating Thickness Measurement Tools C West Market Street 2630 Fairfield Avenue South

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

LECTURE 20 ELECTROMAGNETIC WAVES. Instructor: Kazumi Tolich

Life Science Chapter 2 Study Guide

New Detectors for X-Ray Metal Thickness Measuring

INFRARED ANALYSIS OF SINGLE AND MULTILAYER FILMS IN THE PRODUCTION AREA

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

Components of Optical Instruments

Wave Behavior and The electromagnetic Spectrum

Energy in Photons. Light, Energy, and Electron Structure

LlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points

Thermo Scientific PROSIS Thickness Sensor. Innovative infrared measurement and control solution for single and multilayer gauging applications

Terahertz spectroscopy measurements

CR Basics and FAQ. Overview. Historical Perspective

Photomultiplier Tube

Scintillation Counters

Longitudinal No, Mechanical wave ~340 m/s (in air) 1,100 feet per second More elastic/denser medium = Greater speed of sound

Light has some interesting properties, many of which are used in medicine:

Ultraviolet Visible Infrared Instrumentation

Microwave Sounding. Ben Kravitz October 29, 2009

Section Electromagnetic Waves and the Electromagnetic Spectrum

Friday 25 May 2012 Afternoon

PHYSICS ADVANCED LABORATORY I COMPTON SCATTERING Spring 2002

Explain what is meant by a photon and state one of its main properties [2]

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

Real-time non-contact wet or dry thickness measurement of pressure sensitive, water based, hot melt, laminating and other adhesives

Amorphous Selenium Direct Radiography for Industrial Imaging

(Refer Slide Time: 00:10)

Introduction To NDT. BY: Omid HEIDARY

Conceptual Physics Fundamentals

New Nonwoven Gauging Systems. Rob Lawrence SolveTech, Inc.

Simulation of High Resistivity (CMOS) Pixels

Unit 1.5 Waves. The number waves per second. 1 Hz is 1waves per second. If there are 40 waves in 10 seconds then the frequency is 4 Hz.

The MC5600 MultiChannel Array Gauge. SolveTech, Inc.

EXPERIMENT 5. SCINTILLATION COUNTING AND QUENCH CORRECTION.

Uses of Electromagnetic Waves

Electromagnetic Waves

746A27 Remote Sensing and GIS

ATMOSPHERIC NUCLEAR EFFECTS

Introductory Physics, High School Learning Standards for a Full First-Year Course

SECONDARY ELECTRON DETECTION

Optical In-line Control of Web Coating Processes

1 (a) State two properties which distinguish electromagnetic waves from other transverse waves [2] lamp eye

NEEP 427 PROPORTIONAL COUNTERS. Knoll, Chapters 6 & 14 Sect. I & II

INVESTIGATION OF IMPROVED LABEL CUTTING BY CO 2 LASERS WITH WAVELENGTH OPTIMIZATION Paper #2004

QUALISCAN QMS-12 Traversing Quality Control System

Lecture 6 6 Color, Waves, and Dispersion Reading Assignment: Read Kipnis Chapter 7 Colors, Section I, II, III 6.1 Overview and History

QUALISCAN QMS-12 Traversing Quality Control System

Green Team Science - Mrs. Ferdinand

Geo/SAT 2 INTRODUCTION TO REMOTE SENSING

CALENDERING INDUSTRIES

Microwave Remote Sensing

Non-Radiometric Measurement. Innovative concept of on-line measurement

NM Module Section 2 6 th Edition Christian, Ch. 3

Sensors & Applications Glass Industry. More Precision

StarBright XLT Optical Coatings

THE EXAMINATION OF WORKS OF ART USING ELECTROMAGNETIC RAYS

Cosmic Ray Muon Detection

Astro-photography. Daguerreotype: on a copper plate

ELECTROMAGNETIC WAVES AND LIGHT. Physics 5 th Six Weeks

Design and Fabrication of an Efficient Extreme Ultraviolet Beam Splitter

Total Absorption Dual Readout Calorimetry R&D

Extrusion lines for catheter tubing

Course overview; Remote sensing introduction; Basics of image processing & Color theory

3/5/17. Detector Basics. Quantum Efficiency (QE) and Spectral Response. Quantum Efficiency (QE) and Spectral Response

National 4. Waves and Radiation. Summary Notes. Name:

(A) 2f (B) 2 f (C) f ( D) 2 (E) 2

Radiology. Radiograph: Is the image of an object made with use of X- ray instead of light.

Physics 1C. Lecture 24A. Finish Chapter 27: X-ray diffraction Start Chapter 24: EM waves. Average Quiz score = 6.8 out of 10.

Announcements. EM Induction. Faraday s Law 4/24/15. Why is current induced? EM Induction: Current is Induced

OPERATING CHARACTERISTICS OF THE GEIGER COUNTER

Partial Replication of Storms/Scanlan Glow Discharge Radiation

Feature-level Compensation & Control

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

X-rays in medical diagnostics

Infrared Detectors an overview

Revisions to ASTM D7310 Standard Guide for Defect Detection and Rating of Plastic Films Using Optical Sensors

KÜNDIG CONTROL SYSTEMS The Gauge Manufacturer for Film Extrusion SWISS MADE. K-NDC Rotomat KT. Nuclear thickness gauge for barrier films

Test 1: Example #2. Paul Avery PHY 3400 Feb. 15, Note: * indicates the correct answer.

CCDS. Lesson I. Wednesday, August 29, 12

P6 Quick Revision Questions

Transcription:

Welcome... Please remember that this session is to be held in strict compliance with the TAPPI Antitrust Policy. Specifically, discussing prices or pricing policy and discussing any restraint on competition of any kind will not be tolerated.

TAPPI Extrusion Coating Short Course 2010 Charleston, SC Ted Schnackertz NDC Infrared Engineering, Irwindale, CA

On-Line Gauging for Extrusion Coating Session Objectives: Understand the need for on-line real-time measurement and control Define benefits associated with on-line gauging Understand the technologies available for online gauging Understand the measurement methods

Market Needs/Demands High Quality Films and Coated Products Increased Product Functionality New Product Development Just in Time (JIT) Production Proof of Compliance Low Cost

Producer Challenges Increased Functionality = more layers, thinner layers = more complex structures Cost of Materials JIT = Shorter Production Runs New Product Development Process Analysis & Trouble Shooting Cannot be accomplished w/periodic lab sampling

The Role for On-line Gauging Continuous Real Time Measurement Repeatability of Measurement Process Control Reporting Capability Data Collection Process Diagnostic Tool

Gauging Results

Causes of Variation Process Output

Variation Definitions Short Term Machine Direction (STMD) Cyclic, one minute period or less Surges, roll runout, air knife air flow.. Long Term Machine Direction (LTMD) Cyclic, minutes to hours, days Feed variation, temps cycling, shift changes. Profile (PRO) Cross machine Die bolt, air knife/blade, nip pressure

Gauging Impact on Process Variation STMD Display, analysis, indirect control LTMD Display and direct control PRO Display and direct control

Gauging Sensor Technologies Isotope Beta Transmission Gamma Backscatter Infrared Absorption (NIR) IR Backscatter X-ray XRT (x-ray transmission)

Beta Transmission Sensor Mass measurement (wt/area) Range to 5500 gsm (215mils) Some sensitivity to composition, presence of mineral / metal additives Dual-sided measurement Periodic standardization Typical precision: +/-0.25% Streak resolution 1mm

Beta Transmission Theory Transmission Theory Beta Particles are emitted from source Beta Particles are attenuated by material Detector converts Beta Particles to electrical signal Signal is proportional to mass

Beta Sources Promethium Thin Coatings/Films (0-200g/m2) Krypton Coatings/Film/Sheet (25-1200 g/m2) Strontium Sheet (100-5500 g/m2)

Beta transmission Sensor & Scanner

Gamma Backscatter Sensor Mass Measurement (wt/area) Range - 25-25000 g/m2 (1-1000 mils) Typical precision +/-0.5% Low Composition Sensitivity Single-Sided Sensor No Standardization Small Size

Gamma Backscatter Theory Theory of Operation Photons emitted from source Photons strike product and some scatter back Scintillation Crystal converts photons to light Photomultiplier Tube amplifies light and converts to pulses Pulse rate is proportional to mass

GBS Sensor and Scanner

Infrared Backscatter Sensor Selective absorption mass measurement Direct measurement of coatings on substrate Measurement range 0-1000 g/m2 Precision +/- 0.1 % Passline Tolerance (±50mm) No Standardization Required Non-isotope

Electromagnetic Spectrum Near Infra Red 1.0-2.5 microns γ-rays X-Rays Ultra VISIBLE Violet LIGHT INFRARED MICROWARADIO VE Mid Infrared 2.5-10 microns Increasing Energy

Infrared Absorption Infrared light is preferentially absorbed by bonds between atoms in a molecule ------- H : : O H when the energy (wavelength) is just right

Near-Infrared Spectrum of Water Selective absorption at specific wavelengths 100- %Transmission 50-1.45µ 1.94µ 2.95µ x 1 x 3 x 30 0-1.0 2.0 Wavelength (micrometers) 3.0

Near-Infrared Spectrum of an Organic 100 Spectrum of polyethylene % Transmission 1.72µ 2.32µ 3.40µ 0 X 1 X 3 Wavelength (micrometers) X 25

The Power of IR Discrimination %Transmission 100-50- 1.72µ 1.45µ Key Water 2.32µ 2.40µ Polyethylene 1.94µ 0-1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 Wavelength (micrometers) Application example: Thin water based coating on PE

Infrared Sensor Theory IR Absorption Infrared energy is generated by the lamp Energy is collected and sent through a Filter Wheel Filter Wheel removes unwanted Energy Energy is reflected onto Web Backscattered Energy is Read and Compared to Reference Signal Energy Absorbed is Proportional to Thickness

X-Ray Transmission (XRT) Mass Measurement (weight/area) Range 0-8000 g/m2 (0.2-315 mils) Precision 0.10% Excellent Streak Resolution Some sensitivity to composition, presence of mineral / metal additives Few if any Licensing Issues

X-ray Transmission Theory Theory of Operation X-ray Tube emits X-Ray Energy Some X-rays pass through material Detector converts X-rays into an electrical signal The Electrical Signal is proportional to the Mass

XRT Offers Several Advantages over Nucleonic Gauges Excellent Streak Resolution Higher Precision, Lower Noise Reduced Web Flutter Sensitivity Constant Output Over Time In Coating Applications, Gauge Readouts Can Be Easily Matched Important for Improved True Net Coat With Power removed, no radiation Beta Footprint X-Ray Footprint

XRT Sensor Profile Detail Vs Beta Magnification of ½ strip coating between ½ uncoated areas

Coat Weight Measurement Methods Direct Measurement Greater Accuracy Simpler System Configuration Lower Cost Requires selective sensor (IR) Differential Measurement More flexible (handles wide array of substrates and coatings) Sensor choices

Direct (IR) Measurement of Coat Weight Direct, selective approach requires only one gauge after the coating station Less expensive More accurate Potential to measure coating + moisture Potential to measure coextrusion coating components

Where Direct IR Measurement is not Possible IR technique does have limitations: Cannot measure through opaque materials Materials might be similar in composition (same IR signature) not allowing for selective measurement In these situations, a differential measurement may be the only solution

Differential Coating Measurement Aux unwind 1 Aux unwind 2 Die 1 Die 2 Winder Primary unwind Beta 1 Beta 2 Beta 3 Coat1=beta2 beta1 Coat2=beta3 beta2

Accuracy with Differential Approach Coat Weight Accuracy is Function of TOTAL Mass Note: differential technique is most accurate when coat weight is a significant percentage of total weight

Example(s) using differential beta gauges with 0.25% accuracy: Base substrate = 100 gsm Coating = 3 gsm (10 gsm) Coat error = SQRT (Base error 2 + Total error 2 ) Coat error = SQRT ((100*.0025) 2 + (103*.0025) 2 ) Coat error = SQRT (0.0625 + 0.0663) Coat weight error = 0.36 gsm (.37 gsm) Coat weight error = 12% of 3 gsm (3.7% of 10 gsm) RULE OF THUMB: Coating weight must be at least 10% of total weight (substrate +coating) to achieve acceptable accuracy for Beta sensors and 3% for XRT

Other Challenges for the Differential Technique Substrate has variation, both CD and MD Need to prevent this variability from creating coat weight measurement errors via Same Spot scanner synchronization Composition effect Coating and substrate can have different gauge absorption characteristics, using a technique called True Net Coat can eliminate this effect

Same Spot Why it s Important The sensor measuring the substrate sees this: 125gsm 120gsm 115gsm 110gsm 105gsm 100gsm 95gsm 90gsm 85gsm 80gsm 75gsm Typical Substrate Variation (+/-5%)

Same Spot Why it s Important If the coating is a perfectly flat 10 GSM, the coating on the substrate looks like this to the total gauge: 125gsm 120gsm 115gsm 110gsm 105gsm 100gsm 95gsm 90gsm 85gsm 80gsm 75gsm SUBSTRATE SHAPE PERFECT 10gsm COATING PERFECT 10 GSM COATING ON VARIABLE SUBSTRATE

Making a Good Same Spot Measurement The total gauge measures the same spot on the web after coating that the substrate sensor measured before coating 125gsm 120gsm 115gsm 110gsm 105gsm 100gsm 95gsm 90gsm 85gsm 80gsm 75gsm The total gauge sees this point The substrate gauge sees this point PERFECT 10 GSM COATING ON VARIABLE SUBSTRATE

The Result of a Good Same Spot Measurement The Coating Profile with Good Same Spot looks like this: 15gsm 14gsm 13gsm 12gsm 11gsm 10gsm 9gsm 8gsm 7gsm 6gsm 5gsm PERFECT 10 GSM COATING ON VARIABLE SUBSTRATE

The Result Without Good Same Spot Measurement The Resultant Coating Profile With Poor or No Same Spot: 15gsm 14gsm 13gsm 12gsm 11gsm 10gsm 9gsm 8gsm 7gsm 6gsm 5gsm PERFECT 10 GSM COATING ON VARIABLE SUBSTRATE

True Net Coat Calibration- Why it s Important Traditional Gross Base technique makes sense mathematically but, some coatings and substrates may be SEEN differently by the sensors: Not Particularly True of Gamma Backscatter Which is Mostly Composition Insensitive Beta and X-ray Measurements have Composition Sensitivity Likely that the substrate and coating will have slightly different absorption per unit mass Avoids calibrations for each combination of substrate and coating

Calibration Without True Net Coat Typical Application 3 Substrate Types 4 Product Weights per Type 4 Coating Types 3 Coating Weights per Type 12 Coatings on 12 Substrates POTENTIALLY 144 CALIBRATIONS

True Net Coat Approach Eliminates Base Composition Effects Match the readouts of the two sensors so that they respond exactly to the same sample sets Linearize and calibrate both the base and the gross gauge using the COATING material response curve Since we have same spot measurement and two gauges that respond exactly the same, the base material contributes predictably to the signal magnitude of both the base and gross sensors

Traditional vs. True Net Coat approach Traditional approach uses Gross curve to calculate Gross weight. Gross curve is in flux, changing as base to coat ratio changes With TNC, to calculate coat, both Gross and Base gauges are calibrated against coat response curve. BASE CURVE GROSS CURVE NET CURVE

Calibration With True Net Coat Results in One Calibration for each Coating Type Typical Application 3 Substrate Types 4 Product Weights per Type 4 Coating Types 3 Coating Weights per Type 4 Calibrations Needed for Measuring Coating Weight Vs a possible 144!

Coating Control Auto Profile Control (APC) - PRO Uses auto die with individual die bolt heaters Average weight control - LTMD Typically uses screw speed to maintain target coat weight

Analysis/Diagnostic Tools Gauge Display Data (on screen or hard copy) SPC FFT (fast fourier transform) - STMD Streak Detection OPC for Off-Line Analysis

Summary When possible, Infrared Backscatter usually offers the best accuracy at lowest cost for many coating applications (direct measurement) If a differential system is required, XRT offers significant performance advantages as compared to Nucleonic gauges

Thanks for your Attention! Questions