ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Similar documents
ULT-DIN O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Operating Instructions

Operating Instructions

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Single Channel Loop Detector

Single Channel Loop Detector

Single Channel Loop Detector

Single Channel Loop Detector

Short form User Manual

BEA s digital inductive single loop solution

601/602 Series Inductive Loop Detector

Operations Manual. Model NT11 & NT11-E. June 18 th 2002

MATRIX INDUCTIVE LOOP CONTROL BOX

USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS

AGP-0230 USER MANUAL AMANO

USER MANUAL ULD 910. October 2003 Revision: 03. Single Channel Vehicle Detector ULD 910. Part Number: MIC

FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR

USERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

LMD622 and LMD624 Series

Dual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC ULD 920

Single Channel Loop Detector

DSP-10 Vehicle Detector

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

With Audible Detect Signal

DSP-20 Dual Channel Vehicle Detector With Directional Logic

Underground Loops and Loop Detectors. DoorKing Plug-In Loop Detectors and Loop Accessories Single Channel CH1

Operating Instructions

A53106 SERIES DC-TO-DC CONVERTER

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

Active CCTV Receiver Balun Installation Guide

Phase-sequence Phase-loss Relay

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

MODEL T-110 SERIES OPERATION MANUAL

User Instructions. Model PS-2001L. Power Supply. Model SPS Power Supply. Audiocom Intercom Systems Rev. A, 4/2001.

Single Channel Loop Vehicle detector User Manual

Inductive Loop Detector

SMARTSCAN INFORMATION

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

Model SPDT Power Switch Module

DSP-21 Directional Counting Detector

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

DDM350 Pen-Type Digital Multimeter User s Manual

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

MD12-2 Metal Loop Detector

Four Channel Inductive Loop Detector

COLORMAX. ColorMax Discrete SEN TRONIC AG

Dawson DDM190. Digital Multimeter User s Manual

FACTORY AUTOMATION. MANUAL LC10-* Laying loops for Loop detector LC10-1 and LC10-2

Canoga Traffic Sensing System

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

MODEL 3810/2 Line Impedance Stabilization Network

LT3000 ULTRASONIC LEVEL TRANSMITTER

American Power Design, Inc.

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

Classic Series Public Address Amplifiers C10 & C20 Models

BROADBAND LINEAR AMPLIFIER Model P150

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1.9.doc

TIM-018 Mk2. London Electronics Limited. Triple output loop splitter. Connection details and general information

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

HTA125A/250A. Power Amplifiers. Installation & Use Manual

Non-Submersible Industrial Pressure Transducer

Power-Tronics, Inc. Electronic Voltage Regulators and Static Exciters P.O. Box , Kerrville, Texas 78029

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

NOsparc! MHXAC1F120! MHXAC1F240! MHXAC1F480 PATENTS AND PATENTS PENDING. Contact Arc Suppressor

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

DC200A Displacement Clipper User Manual

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

SPECIAL SPECIFICATION 6004 Digital Card Rack Inductive Loop Detector Assembly

MODEL 421 Over/Under Motor Load Monitor

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

VT1586A Rack Mount Terminal Panel Installation and User s Manual

PCO-7114 Laser Diode Driver Module Operation Manual

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

INSTRUCTION MANUAL DAAB LOOP DETECTOR DB402

SYSTEM OPERATING CONTROLS

RME1-RME1BT INSTRUCCIONES DE INSTALACION INSTALLATIEVOORSCHRIFTEN INSTRUCTIONS D INSTALLATION ИНСТРУКЦИИ ПО УСТАНОВКЕ ISTRUZIONI DI INSTALLAZIONE

Signal Isolation Module. Instruction Manual SIM

RAZOR. Class D Full Range & Monoblock Amplifiers RZ4-1200D RZ4-2000D RZ1-1500D RZ1-2300D

Starbox. Installation guide

Flow Detection MDS Integral or Remote Housing. Installation and Operating Instructions

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES

LPU-2127 User Manual

WARNING: Do not work around outlets while the power is on. Do not stick fingers or tools into an electrical box while the power is on.

TRIAXIAL FLUXGATE MAGNETOMETER OWNER'S MANUAL

A Channel Amplifier

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

RAYTECH USA, Inc. 118 S. 2 nd Street Perkasie, PA USA Tel THE SPY Tel Fax

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

American Power Design, Inc.

301 & 601 Mic/Line Mixers Operation Manual

User s Guide Instructions for Installation and Operation

Transcription:

ULT-MVP ULTRALOOP O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com Technical Support: technical@emxinc.com www.emxinc.com

Contents Cautions and Warnings 2 Product Overview 2 Specifications 3 Operation 4 Controls and Indicators 6 Connections 7 Troubleshooting 7 Loop Installation 8 Ordering Information 10 ULT-MVP Operating Instructions 1

Cautions and Warnings CE REQUIREMENT: Use EMX Pre-formed loops with built-in surge suppression for CE compliance. Connect shield on lead in wire to earth ground. CE REQUIREMENT: Use CE rated power supply for CE compliance providing suppression as specified by EN61000-4-5. Not to be used in personal safety applications. When more than one loop detector is used, set each one to a different frequency. Refer to DIP switch diagram for frequency settings. To reduce the risk of electric shock, do not remove cover or back panel. There are no user-servicable parts inside. Refer servicing to qualified service personnel. Unit must be (earth) GROUNDED Install in a properly rated enclosure (detector is IP30) Power to this device must have short circuit and over current protection (0.25A to 0.5A) IMPORTANT: This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment before connecting this product. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death. Product Overview The ULT-MVP vehicle loop detector is compatible with most gate operators. The ULT-MVP may be used in Center, Safety and Exit loop positions. The UltraMETER display feature makes set-up easy by displaying the optimum sensitivity setting required to detect a vehicle positioned on the loop. Ten sensitivity settings allow for fine adjustment of the detection level. The ULT-MVP provides relay contact outputs indicating vehicle presence and a second set of relay contact outputs providing auxiliary functions. The second output can be used for loop fault or pulse on entry/pulse on exit, or the new EMX feature, Detect On Stop (DOS ). The ULT-MVP features automatic sensitivity boost (ASB), delay, fail-safe/fail-secure and infinite or normal (5 minute) presence. Four frequency settings provide flexibility in preventing crosstalk in multi-loop applications. MODEL DESCRIPTION: ULT-MVP-E ULT-MVP-U ULTRA MVP Vehicle loop detector dual output, AC/DC EU wiring ULTRA MVP Vehicle loop detector dual output, AC/DC US wiring ULT-MVP Operating Instructions 2

Specifications Specifications Sensitivity 10 levels, 0-9 UltraMETER Display Indicates optimum sensitivity level, 0-9 Diagnostic aid Loop frequency 4 settings (low, med-low, med-hi, high) Loop inductance 20 2000µH (Q factor > 5) Grounded loop Isolation transformer allows operation with poor quality loops Automatic tuning Detector tunes to loop on power-up and following frequency count function Environmental tracking Automatic compensation Surge protection Loop circuitry protected by surge suppressors (gas discharge) Presence relay SPDT relay contacts (form C) Output B relay SPDT relay contact (form C) Contact rating (resistive load) 2A @ 30VDC, 0.5A @ 125VAC Power / loop fault indicator Green LED Detect / frequency count indicator Red LED Detect On Stop Requires vehicle to stop for a minimum of 1 second (1-2s typical) ASB (Automatic Sensitivity Boost) Increases sensitivity after initial detection to prevent dropout due to high-bed vehicles Power (see Cautions and Warnings) 9 60 VDC (Max. 0.8 VA) 12 240 VAC (48 62Hz) (Max. 1.4 VA) Operating current (standby/detect) 25mA/50mA Operating temperature -40 C 82 C (-40 F 180 F) 0 95% relative humidity Dimensions (L x W x H) 73mm (2.9 ) x 38mm (1.2 ) x 78mm (3.1 ) Enclosure IP30 Circuit protection Conformal coating Weight 0.25 lbs. (113 g) Connector 11 pin male connector (JEDEC B11-88) ULT-MVP Operating Instructions 3

Operation Power up Upon power up the detector initializes by automatically tuning to the loop. The green LED indicates that the detector is powered and operational. Frequency setting The operating frequency of the loop is a function of the specific loop inductance and DIP switch settings 1 and 2. The primary purpose of the frequency setting is to allow the installer the ability to set different operating frequencies for multi-loop installations, recommended to prevent crosstalk/interference from adjacent loops. After changing the frequency setting, press the Frequency Count switch to re-initialize the detector. To check the operating frequency of a loop, refer to the Frequency Count section. To determine whether crosstalk between adjacent loops is occurring, refer to the UltraMETER Sensitivity Display section. UltraMETER Sensitivity Display The UltraMETER sensitivity display simplifies the installation process by displaying the sensitivity setting required to detect a vehicle on the loop. To use this feature, observe the display while a vehicle is moving into position on the loop, note the number displayed, then adjust the sensitivity setting (rotary switch) to the displayed position. During normal operation, when a vehicle is not on the loop, the display is blank. The effects of crosstalk or other interference can be observed on the display when the loop is vacant. Interference or crosstalk will cause the display to indicate a level, typically 8 or 9. It may be necessary to observe the display for a minute or so to see this effect. Change the frequency setting to prevent crosstalk. Sensitivity setting The 10-position rotary switch allows for precise adjustment of detection level. The sensitivity level increases from position 0 thru 9 with position 0 being the lowest sensitivity. Typical applications require a setting of 3 or 4. To use this feature, observe the UltraMETER display while a vehicle is moving into position on the loop, note the number displayed, then adjust the sensitivity setting (rotary switch) to the displayed position. Frequency Count / Reset Press the Frequency Count switch and count the number of flashes on the red LED. Each flash represents 10 khz. To help to prevent crosstalk when multiple detectors are used for adjacent loops, perform a frequency count on each detector to confirm the operation frequencies are different. Following a frequency count cycle, the detector re-initializes. ULT-MVP Operating Instructions 4

Operation (continued) Automatic Sensitivity Boost The Automatic Sensitivity Boost causes the sensitivity to increase following initial detection. This feature is useful to prevent dropout when detecting high-bed vehicles. The sensitivity returns to its normal setting after the vehicle exits the loop. Decimal point on the display indicates ASB on. Presence output The Presence settings provides two selections, the output can be set for Infinite Presence or Normal Presence. Infinite Presence causes the output to remain in detect mode as long as the vehicle remains on the loop. Normal Presence causes the output to reset after 5 minutes. DO NOT USE THE NORMAL PRESENCE SETTING UNLESS THE OPENING IS PROTECTED BY A SECONDARY SAFETY DEVICE SUCH AS THE IRB-4X. Delay The Delay setting provides a 2 second delay before activating after a vehicle enters the loop, for both Presence and Output B (except when output B is set to Detect-On-Stop). Output B Output B settings allow Pulse on Entry, Pulse on Exit, Detect-On-Stop (DOS ) and Loop Fault. The Detect-On-Stop feature requires that a Vehicle must come to a complete stop over the loop for a minimum of 1 second (typical 1-2s) before Output B activates. Fail Safe / Fail Secure Fail Safe setting causes the ULT-MVP to activate the Presence output in the event a loop failure. Fail Secure setting will cause the ULT-MVP not to activate the Presence output in the event a loop failure. ULT-MVP Operating Instructions 5

Controls and Indicators FREQUENCY COUNT / RESET Press to start frequency count, re-initializes after count DETECT / FREQUENCY COUNT Presence detected No presence Frequency count Red LED on off flashing SENSITIVITY SETTING Sensitivity Position 0.9 Low.high POWER/LOOP FAULT INDICATOR Normal operation Shorted loop Open loop Abrupt change (>20%) Previous loop fault Green LED on 1 fast flash 2 fast flashes 3 fast flashes 2 slow flashes ULTRAMETER DISPLAY Indicates sensitivity setting required to detect vehicle AUTOMATIC SENSITIVITY BOOST ASB enabled DIP switch position 1 on PRESENCE NORMAL (5 min.) INFINITE DIP switch position 2 on off DELAY (2 seconds) DELAY DIP switch position 3 on OUTPUT B DIP switch position MODE 5 4 Pulse on Entry on on Pulse on Exit off on Detect-On-Stop (DOS ) on off Loop Fault off off FAIL SAFE / SECURE Fail Secure Fail Safe DIP switch position 6 on off FREQUENCY SETTINGS DIP switch position FREQUENCY 7 8 Low on on Medium low on off Medium high off on High off off ULT-MVP Operating Instructions 6

Connections Function ULT-MVP-E (EURO) ULT-MVP-U (USA) Loop 7 7 Loop 8 8 Shield EARTH GROUND 9 4 Power * 1 1 Power * 2 2 Presence - Output A N.O. * 5 6 Presence - Output A COM* 6 5 Presence - Output A N.C.* 10 10 Output B N.O.* 3 3 Output B COM* 4 9 Output B N.C.* 11 11 * Refer to power requirements and contact ratings in SPECIFICATIONS table, page 3 ULT-MVP Operating Instructions 7

Troubleshooting Symptom Possible cause Solution Green LED flashes Loop wire shorted or open Check loop resistance on the appropriate loop pins on the control board connector, between.5 ohms and 5 ohms. Green LED flashes, 2 fast Detector remains in detect after vehicle has left loop Intermittent detection No detection Loop was previously shorted or open 1. Faulty loop 2. Poorly crimped terminals 3. Loose connections 1. Faulty loop 2. Poorly crimped terminals 3. Loose connections 4. Cross-talk between adjacent loops 1. Loop wire shorted or open 2. Loop sensitivity set too low Check loop resistance on the appropriate loop pins on the control board connector. 1. Perform megger test from loop lead to ground, should be >100 megaohms 2. Check loop connections to terminals 3. Check splices are properly soldered and sealed against moisture 4. Observe ULTRAMETER display, level indicated on display indicates residual frequency shift from vacant loop to vehicle presence, press Frequency Count switch to re-initialize the detector 1. Perform megger test from loop lead to ground, should be >100 mega ohms 2. Check loop connections to terminals 3. Check splices are properly soldered and sealed against moisture 4. Set adjacent loops to different frequencies (see Frequency Setting) 1. Check loop resistance on the appropriate loop pins on the control board connector, between.5 ohms and 5 ohms. 2. With vehicle on loop, observe ULTRAMETER display, set sensitivity to the level indicated on the display ULT-MVP Operating Instructions 8

Loop Installation NEW SLAB POUR Ty-wrap 1-1/4 PVC pipe to the top of the rebar in the size and configuration of the loop (ex. 4 x 8 ). Then ty-wrap the loop to the top of the PVC frame. This stabilizes the loop during the pour and separates it from the rebar. SAW CUT EXISTING SURFACE Cut 1 deep into the existing surface, place a 45 cut at the corners to prevent sharp edges from damaging the loop wire. Notch out for the T connection where the lead wire connects to the loop. Remove all debris from the finished cut with compressed air. Place the loop into the saw cut. Place backer material into the saw cut over the loop wire and pack tightly. Place a high-quality sealer over the saw cut to seal the surface. RESURFACE ASPHALT Saw cut the existing surface ¾ deep and place a 45 cut at the corners to prevent sharp edges from damaging the loop wire. Remove all debris from the finished cut with compressed air. Place sand over the loop wire to the surface and pack tightly. Lay new asphalt. General Installation Guidelines Use EMX Lite Preformed loops for quick, reliable installations and for CE compliance. Lead-in wire (wire from loop to detector) must be must be twisted a minimum of 6 turns/ foot to avoid the effects of noise or other interference. Detection height is approximately 70% of the shortest side of the loop. Example: detection height for an 4 x 8 loop = 48 x.7 = 33.6 ULT-MVP Operating Instructions 9

Ordering Information ULT-MVP-E Ultra MVP Vehicle Loop Detector, dual output AC/DC, EU wiring ULT-MVP-U Ultra MVP Vehicle Loop Detector, dual output AC/DC, US wiring Accessories PR-XX EMX Lite Preformed Loops Warranty EMX Industries Incorporated warrants all products to be free of defects in materials and workmanship for a period of two years under normal use and service from the date of sale to our customer. This warranty does not cover normal wear and tear, abuse, misuse, overloading, altered products, damage caused by incorrect connections, lightning damage, or use other than intended design. There is no warranty of merchantability. There are no warranties expressed or implied or any affirmation of fact or representation except as set forth herein. EMX Industries Inc. sole responsibility and liability, and the purchaser s exclusive remedy shall be limited to the repair or replacement at EMX Industries option of a part or parts found not conforming to the warranty. In no event shall EMX Industries Inc. be liable for damages, including but not limited to damages resulting from non-conformity, defect in material or workmanship. Effective date: January 1 st, 2002 ULT-MVP Operating Instructions 10

BLANK PAGE ULT-MVP Operating Instructions 11

BLANK PAGE ULT-MVP Operating Instructions 12

4564 Johnston Parkway Cleveland, Ohio 44128 United States of America www.emxinc.com Technical Support: (216) 834-0761 technical@emxinc.com Sales: (216) 518-9888 Fax: (216) 518-9884 salessupport@emxinc.com Revision 1.5 1.29.16 ULT-MVP Operating Instructions 13