Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Similar documents
Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Flush pressure transmitter For viscous and solids-containing media Model S-11

High-quality pressure transmitter For general industrial applications Model S-10

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Pressure transmitter for general industrial applications Model A-10

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

High-quality pressure transmitter For general industrial applications Model S-20

OEM pressure transmitter For mobile working machines Model MH-3

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For water and wastewater Model LW-1

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Submersible pressure sensor For superior applications Model LF-1

Pressure transmitter For sanitary applications Model SA-11

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Resistance thermometer Model TR31, miniature design

Electronic temperature switch with display Model TSD-30

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Resistance thermometer Model TR30, compact design

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Resistance thermometer Model TR30, compact design

Field indicator for current loops with HART communication Models DIH50, DIH52

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Indicator for panel mounting Model

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Field indicator for current loops with HART communication Models DIH50, DIH52

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

ED701 General Industry Pressure Transmitter

Float switch For industrial applications, plastic version Model RLS-2000

Pressure Transmitter SIL

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Mechatronic pressure measurement. Applications. Special features. Description

Materials (other materials see WIKA diaphragm seal program) Model S-10

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Digital indicator for panel mounting With multi-function input Model DI25

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Hand-held temperature calibrator Model CEP3000

HART field temperature transmitter Models TIF50, TIF52, TIF62

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

Analogue Temperature Transmitter

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

High-precision process calibrator Model CED7000

Electronic Pressure Measurement

PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS

In-Line Resistance Thermometers Model TR25

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

Isolators A3/1.

Resistance Thermometers Model Series TR7X0, Sheathed Design

DTM.OCS.S/N - Modbus Level Transmitter

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Screw-in resistance thermometers with plug connector

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Isolating Repeater Input Series 9163

SALES SERVICE +358 (0)

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Temperature Transmitter itemp RTD DIN rail TMT 127

In-line resistance thermometer Model TR25

Temperature Input Module for Zone 1 Series 9482/32

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Isolators A3/1. Vibration Transducer Supply Unit Series

PI2794. Flush pressure sensor with display. 1 alphanumeric display 4-digit 2 status LEDs 3 programming button. Made in Germany

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

U5300 Industrial Pressure Transducer

Digital inductive conductivity transmitter

OPTIFLUX 5000 Technical Datasheet

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Transcription:

Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE 81.50 further approvals see page 6 Applications Chemical, petrochemical industry Oil, natural gas Machine building Special features Measuring ranges from 0... 0.1 to 0... 1,000 bar Approved for use in hazardous areas per FM and CSA Suitable for SIL 2 per IEC 61508/IEC 61511 Fig. left: Pressure transmitter model IS-21-S Fig. right: Pressure transmitter model IS-20-F Description For the highest demands The intrinsically safe pressure transmitters of the IS-2x series are ideally suited to applications in hazardous areas. These pressure transmitters have been specifically designed for the highest industrial requirements and feature the relevant worldwide approvals of FM, CSA and a SIL rating. Design All wetted parts are manufactured from stainless steel and are fully welded. Internal sealing elements are completely avoided, so that the unit can be used with all media. The robust case is also made of stainless steel and provides a minimum ingress protection of IP 65. IP 68 versions are also available. The IS-21-x models are particularly suitable for the measurement of viscous or contaminated media. Due to the flush diaphragm of the process connection, trouble-free pressure measurement is ensured at all times. The field case of the model IS-2x-F enables operation in extreme environmental conditions and is resistant to acids, bases, oils and solvents. Via the field case connection integrated into the case's head, the electrical cabling can be installed quickly and easily. Voltage supply It is recommended to power the pressure transmitter via the WIKA IS Barrier or another suitable Ex isolated barrier. Please see data sheet "AC 80.14" for more information about the WIKA IS Barrier. WIKA data sheet PE 81.50 05/2016 Page 1 of 9

Measuring ranges Relative pressure in bar Measuring range 0... 0.1 0... 0.16 0... 0.25 0... 0.4 0... 0.6 0... 1 0... 1.6 Overpressure limit 1.4 1.4 1.4 4.1 4.1 4.1 8.3 Measuring range 0... 2.5 0... 4 0... 6 0... 10 0... 16 0... 25 0... 40 Overpressure limit 8.3 19.3 41.4 41.4 82.8 82.8 80 Measuring range 0... 60 0... 100 0...160 0... 250 0... 400 0... 600 0... 1,000 1) Overpressure limit 120 200 320 500 800 1,200 1,500 1) Only available for model IS-20 Absolute pressure in bar Measuring range 0... 0.25 0.8... 1.2 0... 0.4 0... 0.6 0... 1 0... 1.6 0... 2.5 Overpressure limit 1.4 4.1 4.1 4.1 4.1 8.3 8.3 Measuring range 0... 4 0... 6 0... 10 0... 16 0... 25 Overpressure limit 19.3 41.4 41.4 82.8 82.8 Vacuum and +/- measuring ranges in bar Measuring range -1... 0-1... +0.6-1... +1.5-1... +3-1... +5-1... +9-1... +15 Overpressure limit 4.1 8.3 8.3 19.3 41.4 41.4 82.8 Measuring range -1... +24 Overpressure limit 82.8 Other measuring ranges on request Output signal Analogue signal 4... 20 ma Permissible load in Ω Model IS-2x-S (power supply - 10 V) / 0.02 A - (cable length in m x 0.14 Ω) Model IS-2x-F (power supply - 11 V) / 0.02 A For the test circuit signal of the IS-2x-F models a load of 15 Ω applies Voltage supply Power supply U+ Model IS-2x-S: DC 10... 30 V Model IS-2x-F: DC 11... 30 V Power consumption P i 1 W (750 mw with approval for category 1D) Reference conditions (per IEC 61298-1) Temperature 15... 25 C Atmospheric pressure 860 1,060 mbar Humidity 45... 75 % r. h., non-condensing Mounting position Calibrated in vertical mounting position with process connection facing downwards. Power supply DC 24 V Time response Settling time 2 ms 10 ms, for medium temperatures below -30 C Page 2 of 9 WIKA data sheet PE 81.50 05/2016

Accuracy data Accuracy at reference conditions Accuracy Standard 0.50 % of span Option 0.25 % of span 1) 1) Only for measuring ranges 0.25 bar Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2). Non-linearity (IEC 61298-2) 0.2 % of span BFSL Non-repeatability 0.1 % of span Mean temperature coefficient of zero point Measuring range 0.25 bar: 0.4 % of span/10 K Measuring range > 0.25 bar: 0.2 % of span/10 K Mean temperature coefficient of span 0.2 % of span/10 K Long-term stability at reference conditions ±0.2 % of span/year Adjustability of zero point and span Adjustment is made using potentiometers inside the instrument. Zero point: ±5 % Span: ±5 % Operating conditions Ingress protection (per IEC 60529) The ingress protection depends on the respective electrical connection. Angular connector DIN 175301-803 A: IP 65 Circular connector M12 x 1: IP 67 Cable outlet, IP 67: IP 67 Cable outlet, IP 68: IP 68 1) Bayonet connector: IP 67 Field case: IP 67 1) 72 h / 300 mbar Vibration resistance (in accordance with IEC 60068-2-6, vibration under resonance) Model IS-2x-S: 20 g Model IS-2x-F: 10 g Shock resistance (per IEC 60068-2-27, mechanical shock) Model IS-2x-S: 1,000 g Model IS-2x-F: 600 g Permissible temperature ranges Medium: see diagramm (page 3) and table (page 4) Ambient: see diagramm (page 3) and table (page 4) Storage: -30... +105 C Permissible temperature ranges for process connections with cooling element 120 150 C 200 C 2 cooling fins Only model IS-21-x -20... +150 C Ambient temperature in C 80 40 3 cooling fins Only model IS-20-x -40... +150 C 5 cooling fins Only model IS-20-x -40... +200 C 0 40 80 120 160 200 Medium temperature in C WIKA data sheet PE 81.50 05/2016 Page 3 of 9

Permissible ambient and medium temperatures 1) Electrical connection Angular connector DIN 175301-803 A Circular connector M12 x 1 Cable outlet IP 67 Bayonet connector Cable outlet IP 68 Field case, model IS-2x-F Cable outlet IP 68, PUR Cable outlet IP 68, FEP Permissible ambient and medium temperatures -20... +80 C -20... +80 C -20... +60 C -20... +80 C -10... +60 C (T6) -10... +60 C (T5) -10... +60 C (T4) -10... +60 C (T6) -10... +60 C (T5) -10... +60 C (T4) -10... +40 C -10... +60 C -10... +60 C -20... +40 C -20... +60 C -20... +80 C 1) For instruments with a flush process connection and a measuring range of 0... 400 or 0... 600 bar, the medium temperature is limited to -30... +70 C. Page 4 of 9 WIKA data sheet PE 81.50 05/2016

Electrical connections Reverse polarity protection U + vs. U- Insulation voltage AC 500 V Connection diagrams Angular connector DIN 175301-803 A U+ 1 U- 2 Circular connector M12 x 1 4 3 1 2 U+ 1 U- 3 Process connections Process connections without cooling element Model IS-20-x Standard Thread size EN 837 G ¼ B G ½ B DIN 3852-E G ¼ A G ½ A DIN 16288 M20 x 1.5 ANSI/ASME B1.20.1 ¼ NPT ½ NPT Model IS-21-x Standard Thread size - G ½ B flush G 1 B flush Hygienic G 1 B flush Process connections with cooling element Bayonet connector U+ A U- B Model IS-20-x Standard EN 837 Thread size G ½ B with 3 cooling fins G ½ B with 5 cooling fins Cable outlet PUR cable FEP cable U+ brown brown U- green green Model IS-21-x Standard Thread size - G ½ B flush with 2 cooling fins Sealings Shield grey grey Process connection Standard Option Field case EN 837 Copper Stainless steel G ½ B flush NBR 1) FKM 2) U+ 1 U- 2 Test+ 3 Test- 4 Shield 5 G 1 B flush NBR 1) FKM 2) Hygienic EPDM - 1) Permissible temperature range: -20... +100 2) Permissible temperature range: -15... +200 The sealings listed under Standard are included in the delivery. WIKA data sheet PE 81.50 05/2016 Page 5 of 9

Materials Wetted parts Stainless steel For sealing materials see "Process connections" Non-wetted parts Stainless steel Internal transmission medium - No oxygen application : Synthetic oil - Oxygen application: Halocarbon oil - Model IS-20-x > 25 bar: Dry measuring cell Approvals FM, IS/I, II, III/1/ABCDEFG/ T*; -2323880; Entity; IP 65 I/0/AEx ia IIC T*; -2323880; Entity; IP 65 NI/I, II, III/2/ABCDEFG/T* -2323880; NI Field wiring IP 65 I / 2 / IIC / T*, -2323880; NI Field wiring IP 65 T* = T4 at 105 C, T5 at 80 C, T6 at 60 C, USA CSA, class I, groups A, B, C and D; class II, groups E, F and G; class III Canadian zone designation: Class I, zone 0, group IIC; Ex ia; IP65; DIP A20; US zone designation: Class I, zone 0, zone 20, group IIC; AEx ia; IP 65, Canada GOST-R, import certificate, Russia GOST, metrology/measurement technology, Russia SIL, functional safety GL, ships, shipbuilding (e.g. offshore), Germany CRN, safety (e.g. electr. safety, overpressure,...), Canada Certificates (option) 3-A conformity of the diaphragm seal, based on a third party verification, in accordance with 3-A standard 74-05 Approvals and certificates, see website Page 6 of 9 WIKA data sheet PE 81.50 05/2016

Dimensions in mm Pressure transmitter Angular connector DIN 175301-803 A Circular connector M12 x 1 Bayonet connector Cable outlet IP 67 Weight: approx. 200 g Weight: approx. 200 g Weight: approx. 200 g Weight: approx. 200 g Cable outlet IP 68 Cable outlet IP 68 Field case, model IS-2x-F Weight: approx. 200 g Weight: approx. 200 g Weight: approx. 350 g WIKA data sheet PE 81.50 05/20163 Page 7 of 9

Process connections for model IS-20-x G L1 G ¼ B EN 837 13 G ½ B EN 837 20 G L1 G ¼ A DIN 3852-E 14 G ½ A DIN 3852-E 17 G L1 ¼ NPT 13 ½ NPT 19 Process connections for model IS-21-x Hygienic G L1 L2 L3 D1 G ½ B 23 20.5 10 18 G L1 L2 L3 D1 G 1 B 23 20.5 10 30 G L1 L2 L3 D1 G 1 B 28 25 9 29.5 Process connections with cooling element for model IS-2x with 2 cooling fins -20... 150 C with 3 cooling fins -40... 150 C with 5 cooling fins -40... 200 C G L1 L2 L3 L4 D1 G ½ B 23 20.5 10 15.5 18 For information on tapped holes and welding sockets, see Technical information IN 00.14 at www.wika.com. Page 8 of 9 WIKA data sheet PE 81.50 05/2016

Accessories and spare parts Sealings for mating connectors Description Order no. Blue (Wika) Brown (neutral) Angular connector DIN 175301-803 A 1576240 11437902 Sealings for process connection Process connection Order no. Copper Stainless steel NBR FKM G ¼ B EN 837 11250810 11250844 - - G ½ B EN 837 11250861 11251042 - - M20 x 1.5 DIN 16288 11250861 11251042 G ¼ A DIN 3852-E - - 1537857 1576534 G ½ A DIN 3852-E - - 1039067 1039075 Isolated barrier Description Order no. IS Barrier 14117118 Ordering information Model / Measuring range / Output signal / Power supply / Non-linearity / Temperature range / Process connection / Sealing / Electrical connection / Certificates 2011 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. WIKA data sheet PE 81.50 05/2016 Page 9 of 9 05/2016 EN WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de