EMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325

Similar documents
EMC TEST REPORT For Prokits Industries Co., Ltd.

FCC PART 15 B MEASUREMENT AND TEST REPORT

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

FCC PART 15 B MEASUREMENT AND TEST REPORT

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

1 - GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES...

TEST REPORT... 1 CONTENT...

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC VERIFICATION SUMMARY Report No.: SZHH

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EMC Test report for LED Panel Light Models , , , , ,

1- GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES...

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

EMC Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. Power supply STR E. Damon Ma / Engineer

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

EN 55015: 2006+A1: 2007 EN 61547: 1995+A1: 2000 EN : 2005+A1: 2008 EN : MEASUREMENT AND TEST REPORT For

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.

EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

Test Report GUANGDONG EAST POWER CO., LTD

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

EMC Test Report. Report Number: M030826

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

EN 55022: 2006+A1: 2007 EN : 2007 EN 55024: 2010 EN : 2006+A2: 2009 EN : Measurement and Test Report.

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29

EMC test report AU01+E04

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

1 SUMMARY OF STANDARDS AND RESULTS

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer:

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

FCC REPORT. 2AKQO-Q740 FCC CFR Title 47 Part 15 Subpart C. * In the configuration tested, the EUT complied with the standards specified above.

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

ELECTRONICS TESTING CENTER(ETC), TAIWAN

FCC Verification TEST REPORT

Page: 1 of 44 EMC TEST REPORT. : Gembird Electronics Ltd. Room 1709, News Building, #2 Shennan Zhong Lu, Shenzhen, China

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

EMC TEST REPORT : EGO-PZ001, EGO-PZ002, EGO-PZ003, EGO-PZ004, EGO-PZ005, EGO-PZ006, EGO-PZ007, EGO-PZ008

EMC TEST REPORT. Report No.: CE10-LIE040101E

EMC TEST REPORT For MUST POWER LIMITED. Inverter. Model No.: PV18-5K MPK, PV18-5K PK, PV18-4K MPK, PV18-4K PK

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

C E R T I F I C A T I O N

2620 Modular Measurement and Control System

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

PT. SARANA KARYA SOLUSINDO.

FCC PART MEASUREMENT AND TEST REPORT

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

TEST REPORT. Issued for:

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

FCC Test Report. FCC Part 15 Subpart B. Neets A/S. Touch Panel (Touch Panel-7B) 2AM ZKS E. William Liu (Engineer)

EMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18

CE TEST CERTIFICATION

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

EMC Test Report. Report No.: AGC EE01 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.

Test Report GUANGDONG EAST POWER CO., LTD

EN V1.9.2 EN V Measurement and Test Report YAMAY ELECTRONICS CO., LTD.

CE EMC Test Report GUANGZHOU DMKEMOTOR CO. LTD

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U

Transcription:

Page 1 of 39 EMC TEST REPORT For Shenzhen Scotle Technology Ltd CNC ROUTER Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325 Test Report Number : ESTBA151101209E SHENZHEN EXACT STANDARD TESTING TECHNOLOGY CO., LTD Room 501, Building 36, Chentian Industrial Park, Baotian 1st Road, Xixiang, Baoan District, Shenzhen, China Tel:+86-755-23112566 Fax:+86-755-23114766

Page 2 of 39 TABLE OF CONTENTS 1. GENERAL INFORMATION... 4 1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT)... 4 1.2 TEST STANDARDS... 4 1.3 TEST SUMMARY... 5 1.4 TEST METHODOLOGY... 5 1.5 TEST FACILITY... 5 1.6 TEST EQUIPMENT LIST AND DETAILS... 6 2. SYSTEM TEST CONFIGURATION... 8 2.1 JUSTIFICATION... 8 2.2 EUT EXERCISE SOFTWARE... 8 2.3 SPECIAL ACCESSORIES... 8 2.4 EQUIPMENT MODIFICATIONS... 8 2.5 CONFIGURATION OF TEST SYSTEM... 8 2.6 TEST SETUP DIAGRAM... 8 3. DISTURBANCE VOLTAGE AT THE MAINS TERMINALS... 9 3.1 MEASUREMENT UNCERTAINTY... 9 3.2 LIMIT OF DISTURBANCE VOLTAGE AT THE MAINS TERMINALS (EN 61800-3 CATEGORY C3)... 9 3.3 EUT SETUP... 9 3.4 INSTRUMENTS SETUP... 9 3.5 TEST PROCEDURE...10 3.6 SUMMARY OF TEST RESULTS...10 3.7 DISTURBANCE VOLTAGE TEST DATA...10 3.8 TEST RESULT...10 CONDUCTED EMISSION TEST DATA...11 CONDUCTED EMISSION TEST DATA...12 4. RADIATED DISTURBANCES... 13 4.1 MEASUREMENT UNCERTAINTY...13 4.2 LIMIT OF RADIATED DISTURBANCES (EN 61000-6-4)...13 4.3 EUT SETUP...13 4.4 TEST RECEIVER SETUP...13 4.5 TEST PROCEDURE...14 4.6 RADIATED EMISSIONS TEST RESULT...14 4.7 TEST RESULT...14 RADIATED EMISSION TEST DATA...15 RADIATED EMISSION TEST DATA...16 5. HARMONIC CURRENT TEST (EN 61000-3-2)... 17 5.1 APPLICATION OF HARMONIC CURRENT EMISSION...17 5.2 MEASUREMENT DATA...17 5.3 TEST RESULTS...17 6. VOLTAGE FLUCTUATIONS AND FLICKER TEST (EN 61000-3-3)... 21 6.1 APPLICATION OF VOLTAGE FLUCTUATIONS AND FLICKER TEST...21 6.2 MEASUREMENT DATA...21 6.3 TEST RESULTS...21 7. EN 61000-6-4 MEASUREMENT INSTRUMENTATION... 23 7.1 ELECTROSTATIC DISCHARGE TEST SYSTEM...23 7.2 RADIATED SUSCEPTIBILITY TEST SYSTEM...23 7.3 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST SYSTEM...23 7.4 SURGE IMMUNITY TEST SYSTEM...23 7.5 CONDUCTED SUSCEPTIBILITY TEST SYSTEM...23 7.6 EQUIPMENT TEST TABLE...24 7.7 INSTRUMENT CALIBRATION...24 8. EN 61000-6-4 TEST PROCEDURES... 25 8.1 EUT AND CABLE PLACEMENT...25 8.2 APPLICATION OF ELECTROSTATIC DISCHARGE IMMUNITY TEST...25 8.3 APPLICATION OF RADIATED SUSCEPTIBILITY TEST...25 8.4 APPLICATION OF ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST...25 8.5 APPLICATION OF SURGE IMMUNITY TEST...25

Page 3 of 39 8.6 APPLICATION OF CONDUCTED SUSCEPTIBILITY TEST...25 8.7 DEVIATIONS FROM THE STANDARD...25 9. TEST DATA... 26 9.1 ELECTROSTATIC DISCHARGE IMMUNITY TEST (IEC 61000-4-2)...26 9.2 RADIATED SUSCEPTIBILITY TEST (IEC 61000-4-3)...27 9.3 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4)...28 9.4 SURGE IMMUNITY TEST (IEC 61000-4-5)...29 9.5 CONDUCTED SUSCEPTIBILITY TEST (IEC 61000-4-6)...29 10. TEST RESULTS... 30 10.1 IEC 61000-4-2 ELECTROSTATIC DISCHARGE IMMUNITY TEST CONFIGURATION...30 10.2 IEC 61000-4-3 RADIATED SUSCEPTIBILITY TEST CONFIGURATION...30 10.3 IEC 61000-4-4 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST CONFIGURATION...30 10.4 IEC 61000-4-5 SURGE IMMUNITY TEST CONFIGURATION...30 10.5 IEC 61000-4-6 CONDUCTED SUSCEPTIBILITY TEST CONFIGURATION...30 10.6 IEC 61000-4-11 VOLTAGE DIPS, SHORT INTERRUPTIONS IMMUNITY TESTS CONFIGURATION...30 APPENDIX A. EUT PHOTOGRAPHS... 31 EUT - FRONT VIEW...31 EUT - BACK VIEW...31 EUT - INSIDE VIEW...32 EUT - INSIDE VIEW...32 EUT - INSIDE VIEW...33 EUT - INSIDE VIEW...33 EUT - INSIDE VIEW...34 EUT - INSIDE VIEW...34 EUT - INSIDE VIEW...35 EUT - INSIDE VIEW...35 EUT - INSIDE VIEW...36 EUT - INSIDE VIEW...36 APPENDIX B. TEST SETUP PHOTOGRAPHS... 37 CONDUCTED EMISSION...37 RADIATED EMISSION...37 RADIATED SUSCEPTIBILITY TEST...38 HARMONIC & VOLTAGE FLUCTUATIONS AND FLICKER TEST...38 ELECTROSTATIC DISCHARGE IMMUNITY TEST...39 ELECTRICAL FAST TRANSIENT/BURST & VOLTAGE DIPS, SHORT INTERRUPTIONS & SURGE IMMUNITY TEST...39

Page 4 of 39 1. GENERAL INFORMATION 1.1 Product Description for Equipment Under Test (EUT) Client Information Applicant: Address of applicant: Manufacturer: Address of Manufacturer: Shenzhen Scotle Technology Ltd Room 401, A Building, Nankeng, Bantian, Longgang, Shenzhen, China Shenzhen Scotle Technology Ltd Room 401, A Building, Nankeng, Bantian, Longgang, Shenzhen, China General Description of E.U.T EUT Description: CNC ROUTER Trade Name: Model No.: Rating: Test Power Supply: 1.2 Test Standards N/A HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325 (NOTE: The models of EUT are identical except appearance of equipment. Unless otherwise specified, all tests were performed on model HY-3040, to represent the other similar models.) AC 220-240V, 50/60Hz AC 230V, 50Hz The following Declaration of Conformity report of EUT is prepared in accordance with EN 61800-3: 2004+A1: 2012 EN 61000-3-2: 2006+A1: 2009+A2: 2009 EN 61000-3-3: 2008 EN 61000-6-4: 2007+A1: 2011 EN 61000-6-2: 2005 The objective of the manufacturer is to demonstrate compliance with the described standards above. Note: This test report is limited to the above client company and the product model only. It may not be duplicated without prior written consent of SHENZHEN EXACT STANDARD TESTING TECHNOLOGY CO., LTD. Date of Test : Nov. 25~30, 2015 Prepared by : (Engineer: David He) Reviewer : (Project Manager: Ronnie Liu) Approved & Authorized Signer : (Manager: Alex Chen)

Page 5 of 39 1.3 Test Summary For the EUT described above. The standards used were EN 61800-3 category C3 for Conducted Emissions, EN 61000-6-4 for Radiated Emissions & EN 61000-6-2 for Immunity. Table 1: Tests Carried Out Under EN 61800-3: 2004+A1: 2012 & EN 61000-6-4: 2007+A1: 2011 Standard Test Items Status EN 61800-3: 2004+A1: 2012 & EN 61000-6-4: 2007+A1: 2011 Disturbance Voltage at The Mains Terminals (150KHz To 30MHz) Radiated Disturbances (30MHz To 1000MHz) Table 2: Tests Carried Out Under EN61000-3-2: 2006+A1: 2009+A2: 2009 / EN 61000-3-3: 2008 Standard Test Items Status EN 61000-3-2: 2006+A1: 2009 +A2: 2009 Harmonic Current Test EN 61000-3-3: 2008 Voltage Fluctuations and Flicker Test Table 3 : Tests Carried Out Under EN 61000-6-2: 2005 Standard Test Items Status IEC61000-4-2: 2008 Electrostatic discharge Immunity IEC61000-4-3: 2008 Radiated Susceptibility IEC61000-4-4: 2004 Electrical Fast Transient/Burst Immunity IEC61000-4-5: 2005 Surge Immunity IEC61000-4-6: 2006 Conducted Susceptibility (150kHz to 80MHz) IEC61000-4-8: 2009 Power Frequency Magnetic Field Immunity (50/60Hz) IEC61000-4-11: 2004 Voltage Dips, Short Interruptions Immunity Indicates that the test is applicable Indicates that the test is not applicable 1.4 Test Methodology All measurements contained in this report were conducted with CISPR 16-1: 2002, radio disturbance and immunity measuring apparatus, and CISPR16-2: 2002, Method of measurement of disturbances and immunity. 1.5 Test Facility The test facility is recognized, certified, or accredited by the following organizations: FCC Registration No.: 600491 Global United Technology Service Co., Ltd has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration 600491

Page 6 of 39 1.6 Test Equipment List and Details Table 1: Test Equipment for Emission Test and Harmonic Current / Flicker Test Equipment Manufacturer Model# Serial # Data of Cal. Due Data 3m Semi-Anechoic ZhongYu Electro 9.2(L)*6.2( GTS201 Apr. 28, 2015 Apr. 27, 2016 Chamber W)*6.4(H) EMI Test Receiver Rohde & Schwarz ESU26 GTS203 Apr. 28, 2015 Apr. 27, 2016 EMI Test Software AUDIX E3 N/A N/A N/A Coaxial cable GTS N/A GTS400 Mar. 18, 2015 Mar. 17, 2016 BiConiLog SCHWARZBECK VULB9163 GTS204 Mar. 12, 2015 Mar. 11, 2016 Antenna MESS-ELEKTRONIK Amplifier(100KHz HP 8347A GTS210 Mar. 18, 2015 Mar. 17, 2016-3GHz) Double-ridged SCHWARZBECK 9120D-829 GTS205 Mar. 12, 2015 Mar. 11, 2016 horn MESS-ELEKTRONIK Amplifier(2GHz- HP 8349b GTS224 Mar. 18, 2015 Mar. 17, 2016 20GHz) Band filter Amindeon 82346 SEL0094 Mar. 18, 2015 Mar. 17, 2016 Shielding Room Zhong Yu Electron 7.0(L)x3.0( GTS206 Apr. 10, 2015 Apr. 10, 2016 W)x3.0(H) LISN SCHWARZBECK NSLK GTS207 Mar. 18, 2015 Mar. 17, 2016 MESS-ELEKTRONIK 8127 ISN Rohde & Schwarz ENY22110 EMC011 Mar. 18, 2015 Mar. 17, 2016 9 4 ISN Rohde & Schwarz ENY41111 EMC011 Mar. 18, 2015 Mar. 17, 2016 0 5 EMI Test Receiver Rohde & Schwarz ESCS30 GTS208 Mar. 18, 2015 Mar. 17, 2016 Coaxial Cable GTS N/A GTS207 Mar. 18, 2015 Mar. 17, 2016 AC Power Source EMTEST ACS500 GTS218 Apr. 28, 2015 Apr. 27, 2016 Power Analyzer EMTEST DPA500 GTS217 Apr. 28, 2015 Apr. 27, 2016 Test software EMTEST ACS N/A N/A N/A

Page 7 of 39 Table 2: Test Equipment for Immunity Test Equipment Manufacturer Model# Serial # Data of Cal. Due Data ESD Simulator EMPEK ESD- GTS219 Mar. 03, 2015 Mar. 02, 2016 2030A Tsurge EMTEST system UCS500N GTS216 Sept. 09 2015 Sept. 09 2016 Capacitive Clamp Thermo N/A GTS220 N/A N/A ELECTRON 3m Semi-Anechoic ETS-LINDGREN N/A N/A Apr.28, 2015 Apr.27, 2016 Chamber Signal Generator Rohde & Schwarz SML03 SEL0068 Aug. 01, 2015 Jul. 31, 2016 RF Amplifier 30M- Amplifier 250W SEL0066 Apr.28, 2015 Apr.27, 2016 1GHz Research 1000A RF Amplifier 0.8M- Amplifier 60S1G3 SEL0065 Apr.28, 2015 Apr.27, 2016 3.0GHz Research Power Meter Rohde & Schwarz NRVD SEL0069 Mar. 18, 2015 Mar. 17, 2016 Power Meter Rohde & Schwarz URV5-Z2 SEL0071 Mar. 18, 2015 Mar. 17, 2016 Power Meter Rohde & Schwarz URV5-Z2 SEL0072 Mar. 18, 2015 Mar. 17, 2016 Software EMC32 Rohde & Schwarz EMC32-S SEL0082 N/A N/A Log-periodic Amplifier AT1080 SEL0073 N/A N/A Antenna Research Antenna Tripod Amplifier TP1000A SEL0074 N/A N/A Research ProPLUS System Thermo N/A SEL0007 Apr.28, 2015 Apr.27, 2016 ELECTRON Pro PLUS Capacitive Thermo N/A SEL0008 N/A N/A Clamp ELECTRON CM-HCOIL H-field Thermo N/A SEL0010 Apr.28, 2015 Apr.27, 2016 loop ELECTRON RF-Generator SCHAFFNER NSG2070 SEL0039 Apr.28, 2015 Apr.27, 2016 Coupling/Decoupling Network SCHAFFNER CDNM016 SEL0040 Apr.28, 2015 Apr.27, 2016 EM CLAMP SCHAFFNER KEMZ801 SEL0041 Apr.28, 2015 Apr.27, 2016 Table 3: General used equipment Equipment Manufacturer Model# Serial # Data of Cal. Due Data Humidity/Temperature Shanghai ZJ1-2B GTS250 Apr.28, 2015 Apr. 27, 2016 Indicator Barometer Changchun DYM3 GTS251 Jun. 22, 2013 Jun. 21, 2016

Page 8 of 39 2. SYSTEM TEST CONFIGURATION 2.1 Justification The system was configured for testing in a typical fashion (as normally used by a typical user). 2.2 EUT Exercise Software The EUT exercising program used during radiated and conducted testing was designed to exercise the various system components in a manner similar to a typical use. The software offered by manufacture, can let the EUT being normal operation. 2.3 Special Accessories As shown in section 2.5, interface cable used for compliance testing is shielded as normally supplied by Shenzhen Scotle Technology Ltd and its respective support equipment manufacturers. 2.4 Equipment Modifications The EUT tested was not modified by SHENZHEN EXACT STANDARD TESTING TECHNOLOGY CO., LTD. 2.5 Configuration of Test System Power EUT Motor 2.6 Test Setup Diagram EUT Simulater 1.0m 1.5m

Page 9 of 39 3. DISTURBANCE VOLTAGE AT THE MAINS TERMINALS 3.1 Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are spectrum analyzer, cable loss, and LISN. The Treatment of Uncertainty in EMC Measurements, the best estimate of the uncertainty of any conducted emissions measurement is +2.4 db. 3.2 Limit of Disturbance Voltage At The Mains Terminals (EN 61800-3 category C3) Current of EUT I 100A Frequency Range (MHz) Quasi-Peak Limits ( dbuv) Average 0.150~0.500 100 90 0.500~5.000 86 76 5.000~30.00 90-70 (Decreases with log of frequency) 80-60 (Decreases with log of frequency) Note: (1)The tighter limit shall apply at the edge between two frequency bands. 3.3 EUT Setup The setup of EUT is according with CISPR 16-1: 2002, CISPR16-2: 2002 measurement procedure. The specification used was the EN 61800-3 limits. The EUT was placed center and the back edge of the test table. The spacing between the peripherals was 10 cm. Maximum emission emitted from EUT was determined by manipulating the EUT, support equipment, interconnecting cables and varying the mode of operation and the levels in the final result of the test were recorded with the EUT running in the operating mode that maximum emission was emitted. 3.4 Instruments Setup The receiver was set with the following configurations: Test Receiver Setting: Frequency Range.150 KHz to 30 MHz Detector..Peak & Quasi-Peak & Average Sweep Speed Auto IF Band Width...9 KHz

Page 10 of 39 3.5 Test Procedure During the conducted emission test, the EUT power cord was connected to the auxiliary outlet of the first Artificial Mains. Maximizing procedure was performed on the six (6) highest emissions to ensure EUT compliance using all installation combination. All data was recorded in the peak detection mode. Quasi-peak and Average readings were only performed when an emission was found to be marginal (within -10 db V of specification limits). Quasi-peak readings are distinguished with a "QP". Average readings are distinguished with a "AV". 3.6 Summary of Test Results According to the data in section 3.6, the EUT complied with the EN 61800-3 Conducted margin, with the worst margin reading of: 3.7 Disturbance Voltage Test Data Temperature ( ) 22 Humidity ( %RH ) 58 Barometric Pressure ( mbar ) 1001.1 EUT CNC ROUTER M/N HY-3040 Operating Mode On Mode Test data see following pages. Remark: (1) When PK reading is less than relevant limit 20dB, the QP reading and AV reading will not be recorded. (2) Where QP reading is less than relevant AV limit, the AV reading will not be measured 3.8 Test Result Pass.

Page 11 of 39 Conducted Emission Test Data EUT: CNC ROUTER Model No: HY-3040 Operation Condition: On Mode Test Voltage: AC 230V, 50Hz Test Part: L Test Result: PASS Marker: 195 khz 87.96 dbµv Delta Mk: 0 Hz 12.09 db 130 120 Level [dbµv] 100 80 60 40 20-10 0 150k 300k 500k 1M 2M 3M 5M 7M 10M 30M Frequency [Hz] MES L PK MES L AV LIM IEC 61800-3 V QP LIM IEC 61800-3 V AV Voltage QP Limit Voltage AV Limit Frequency Level Limit-QP Level Limit-AV MHz dbµv dbµv dbµv dbµv 0.195000 81.50 100.00 70.50 90.00

Page 12 of 39 Conducted Emission Test Data EUT: CNC ROUTER Model No: HY-3040 Operation Condition: On Mode Test Voltage: AC 230V, 50Hz Test Part: N Test Result: PASS Marker: 204 khz 85.27 dbµv Delta Mk: 0 Hz 14.78 db 130 120 Level [dbµv] 100 80 60 40 20-10 0 150k 300k 500k 1M 2M 3M 5M 7M 10M 30M Frequency [Hz] MES L PK MES L AV LIM IEC 61800-3 V QP LIM IEC 61800-3 V AV Voltage QP Limit Voltage AV Limit Frequency Level Limit-QP Level Limit-AV MHz dbµv dbµv dbµv dbµv 0.204000 79.70 100.00 68.00 90.00

Page 13 of 39 4. RADIATED DISTURBANCES 4.1 Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency interpolation, measurement distance variation, site imperfections, mismatch (average), and system repeatability. The Treatment of Uncertainty in EMC Measurements, the best estimate of the uncertainty of a radiation emissions measurement is +4.0 db. 4.2 Limit of Radiated Disturbances (EN 61000-6-4) Frequency (MHz) Distance (Meters) Field Strengths Limits (db V/m) 30 ~ 230 3 60 230 ~ 1000 3 70 Note: (1) The tighter limit shall apply at the edge between two frequency bands. (2) Distance refers to the distance in meters between the test instrument antenna and the closest point of any part of the E.U.T. (3) If the highest frequency of the internal sources of the EUT is less than 108 MHz, the measurement shall only be made up to 1 GHz. 4.3 EUT Setup The radiated emission tests were performed in the open area 3-meter test site, using the setup accordance with the CISPR 16-1: 2002, CISPR16-2: 2002. The specification used was EN 61000-6-4 limits. The EUT was placed on the center of the test table. Maximum emission emitted from EUT was determined by manipulating the EUT, support equipment, interconnecting cables and varying the mode of operation and the levels in the final result of the test were recorded with the EUT running in the operating mode that maximum emission was emitted. 4.4 Test Receiver Setup According to EN 61000-6-4 rules, the frequency was investigated from 30 to 1000 MHz. During the radiated emission test, the test receiver was set with the following configurations: Test Receiver Setting: Detector..Peak & Quasi-Peak IF Band Width...120KHz Frequency Range.30MHz to 1000MHz Turntable Rotated.0 to 360 degrees Antenna Position: Height. 1m to 4m Polarity...Horizontal and Vertical

Page 14 of 39 4.5 Test Procedure Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all installation combinations. All data was recorded in the peak detection mode. Quasi-peak readings performed only when an emission was found to be marginal (within -10 db V of specification limits), and are distinguished with a "QP" in the data table. 4.6 Radiated Emissions Test Result Temperature ( ) 22 Humidity ( %RH ) 58 Barometric Pressure ( mbar ) 1001.0 EUT CNC ROUTER M/N HY-3040 Operating Mode On Mode Test data see following pages. Remark: (1) When PK reading is less than relevant limit 20dB, the QP reading and AV reading will not be recorded. (2) Where QP reading is less than relevant AV limit, the AV reading will not be measured 4.7 Test Result Pass

Page 15 of 39 Radiated Emission Test Data EUT: CNC ROUTER Model No: HY-3040 Operation Condition: On Mode Test Voltage: AC 230V, 50Hz Test Site: 3m Chamber Test Specification: Horizontal Marker: 86.372745 MHz 31.8 dbµv/m 80 Level [dbµv/m] 70 60 50 40 30 20 10 0 30M 50M 70M 100M 200M 300M 500M 700M 1G Frequency [Hz] MES H LIM 61000-6-4 Field Strength QP Limit

Page 16 of 39 Radiated Emission Test Data EUT: CNC ROUTER Model No: HY-3040 Operation Condition: On Mode Test Voltage: AC 230V, 50Hz Test Site: 3m Chamber Test Specification: Vertical Marker: 144.689379 MHz 36.38 dbµv/m 80 Level [dbµv/m] 70 60 50 40 30 20 10 0 30M 50M 70M 100M 200M 300M 500M 700M 1G Frequency [Hz] MES V LIM 61000-6-4 Field Strength QP Limit

Page 17 of 39 5. HARMONIC CURRENT TEST (EN 61000-3-2) 5.1 Application of Harmonic Current Emission Compliance to these standards ensures that tested equipment will not generate harmonic currents at levels that cause unacceptable degradation of the main environment. This directly contributes to meeting compatibility levels established in other EMC standards, which defines compatibility levels for low-frequency conducted disturbances in low-voltage supply systems. 5.2 Measurement Data Note: For detailed test data, refer to the following pages: Standard used Observation time EUT M/N Operating Mode EN 61000-3-2 Quasi-stationary 180s CNC ROUTER HY-3040 On Mode Test Result PASS 5.3 Test Results PASS.

Page 18 of 39 Harmonics Per EN/IEC61000-3-2 EUT: CNC ROUTER Test category: Per EN/IEC61000-3-2 (European limits) Test Margin: 100 Test date: 11/27/2015 Start time: 15:05:12 End time: 15:08:02 Test duration (min): 2.5 Model: HY-3040 Comment: On Test Result: Pass Source qualification: Normal Current & voltage waveforms 6 300 Current (Amps) 4 2 0-2 -4-6 200 100 0-100 -200-300 Voltage (Volts) Harmonics and Class A limit line European Limits Current RMS(Amps) 0.125 0.100 0.075 0.050 0.025 0.000 4 8 12 16 20 24 28 32 36 40 Harmonic #

Page 19 of 39 Current Test Result Summary (Phase A-Run time) EUT: CNC ROUTER Test category: Per EN/IEC61000-3-2 (European limits) Test Margin: 100 Test date: 11/27/2015 Start time: 15:05:12 End time: 15:08:02 Test duration (min): 2.5 Model: HY-3040 Comment: On Test Result: Pass Source qualification: Normal THC (A): 0.95 I-THD (%): 96.36 POHC (A): 0.227 POHC Limit (A): 0.251 Highest parameter values during test: V_RMS (Volts): 230.05 Frequency (Hz): 50.00 I_Peak (Amps): 6.230 I_RMS (Amps): 1.352 I_Fund (Amps): 0.616 Crest Factor: 7.230 Power (Watts): 165.3 Power Factor: 0.529 Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.001 0.060 2.1 0.001 0.090 1.60 Pass 3 0.000 N/A N/A 0.002 N/A N/A N/A 4 0.001 0.030 2.3 0.001 0.045 1.91 Pass 5 0.001 0.080 0.5 0.001 0.120 0.52 Pass 6 0.000 0.020 1.0 0.001 0.030 1.75 Pass 7 0.000 0.054 0.7 0.001 0.081 0.80 Pass 8 0.000 0.015 2.0 0.001 0.022 2.27 Pass 9 0.000 N/A N/A 0.001 N/A N/A N/A 10 0.000 0.012 2.2 0.000 0.018 2.46 Pass 11 0.000 0.023 1.2 0.000 0.035 1.26 Pass 12 0.000 0.010 1.5 0.000 0.015 2.54 Pass 13 0.000 0.015 1.4 0.000 0.022 1.60 Pass 14 0.000 N/A N/A 0.000 N/A N/A N/A 15 0.000 N/A N/A 0.000 N/A N/A N/A 16 0.000 N/A N/A 0.000 N/A N/A N/A 17 0.000 N/A N/A 0.000 N/A N/A N/A 18 0.000 N/A N/A 0.000 N/A N/A N/A 19 0.000 N/A N/A 0.000 N/A N/A N/A 20 0.000 N/A N/A 0.000 N/A N/A N/A 21 0.000 N/A N/A 0.000 N/A N/A N/A 22 0.000 N/A N/A 0.000 N/A N/A N/A 23 0.000 N/A N/A 0.000 N/A N/A N/A 24 0.000 N/A N/A 0.000 N/A N/A N/A 25 0.000 N/A N/A 0.000 N/A N/A N/A 26 0.000 N/A N/A 0.000 N/A N/A N/A 27 0.000 N/A N/A 0.000 N/A N/A N/A 28 0.000 N/A N/A 0.000 N/A N/A N/A 29 0.000 N/A N/A 0.000 N/A N/A N/A 30 0.000 N/A N/A 0.000 N/A N/A N/A 31 0.000 N/A N/A 0.000 N/A N/A N/A 32 0.000 N/A N/A 0.000 N/A N/A N/A 33 0.000 N/A N/A 0.000 N/A N/A N/A 34 0.000 N/A N/A 0.000 N/A N/A N/A 35 0.000 N/A N/A 0.000 N/A N/A N/A 36 0.000 N/A N/A 0.000 N/A N/A N/A 37 0.000 N/A N/A 0.000 N/A N/A N/A 38 0.000 N/A N/A 0.000 N/A N/A N/A 39 0.000 N/A N/A 0.000 N/A N/A N/A 40 0.000 N/A N/A 0.001 N/A N/A N/A

Page 20 of 39 Voltage Source Verification Data (Phase A-Run time) EUT: CNC ROUTER Test category: Per EN/IEC61000-3-2 (European limits) Test Margin: 100 Test date: 11/27/2015 Start time: 15:05:12 End time: 15:08:02 Test duration (min): 2.5 Model: HY-3040 Comment: On Test Result: Pass Source qualification: Normal Highest parameter values during test: V_RMS (Volts): 230.05 Frequency (Hz): 50.00 I_Peak (Amps): 6.230 I_RMS (Amps): 1.352 I_Fund (Amps): 0.616 Crest Factor: 7.230 Power (Watts): 165.3 Power Factor: 0.529 Harm# Harmonics V-rms Limit V-rms % of Limit Status 2 0.379 0.460 82.21 OK 3 0.484 2.070 23.33 OK 4 0.083 0.460 18.25 OK 5 0.145 0.920 15.83 OK 6 0.058 0.460 12.78 OK 7 0.163 0.690 23.65 OK 8 0.046 0.460 9.99 OK 9 0.104 0.460 22.51 OK 10 0.049 0.460 10.56 OK 11 0.207 0.230 89.85 OK 12 0.043 0.230 18.69 OK 13 0.229 0.230 99.64 OK 14 0.044 0.230 19.14 OK 15 0.097 0.230 42.01 OK 16 0.046 0.230 19.87 OK 17 0.206 0.230 89.54 OK 18 0.039 0.230 17.08 OK 19 0.219 0.230 95.07 OK 20 0.054 0.230 23.37 OK 21 0.087 0.230 37.99 OK 22 0.043 0.230 18.56 OK 23 0.156 0.230 67.63 OK 24 0.040 0.230 17.34 OK 25 0.159 0.230 69.12 OK 26 0.044 0.230 19.08 OK 27 0.060 0.230 25.96 OK 28 0.044 0.230 19.08 OK 29 0.101 0.230 43.80 OK 30 0.038 0.230 16.73 OK 31 0.099 0.230 43.02 OK 32 0.037 0.230 16.09 OK 33 0.040 0.230 17.22 OK 34 0.037 0.230 16.08 OK 35 0.070 0.230 30.33 OK 36 0.040 0.230 17.39 OK 37 0.070 0.230 30.29 OK 38 0.037 0.230 16.06 OK 39 0.040 0.230 17.27 OK 40 0.037 0.230 16.04 OK

Page 21 of 39 6. VOLTAGE FLUCTUATIONS AND FLICKER TEST (EN 61000-3-3) 6.1 Application of Voltage Fluctuations and Flicker Test Compliance to these standards ensures that tested equipment will not generate flickers and voltage change at levels that cause unacceptable degradation of the main environment. This directly contributes to meeting compatibility levels established in other EMC standards, which defines compatibility levels for low-frequency conducted disturbances in low-voltage supply systems. 6.2 Measurement Data Standard used Short time (Pst) Observation time Flicker meter EUT M/N Operating Mode EN 61000-3-3 Flicker 10 min 10 min (1 Flicker measurement) AC 230V, 50Hz CNC ROUTER HY-3040 On Mode Test Result PASS 6.3 Test Results The EUT was subjected to the voltage fluctuations and flicker test required by EN 61000-3-3: 2008. The EUT measured values of the Flicker test of the input current, including live current and neutral current, shall be compared with the limits given in section 6.2. Test setup photographs presented in Appendix B. The test results are shown in the following page.

Page 22 of 39 Flicker Test Summary per EN/IEC61000-3-3 EUT: CNC ROUTER Test category: All parameters (European limits) Test Margin: 100 Test date: 11/27/2015 Start time: 7:16:56 PM End time: 7:27:20 PM Test duration (min): 10 Model: HY-3040 Comment: load Test Result: Pass Status: Test Completed Pst i and limit line European Limits 1.00 0.75 Pst 0.50 0.25 19:27:19 Plt and limit line Plt 0.6 0.5 0.4 0.3 0.2 0.1 19:27:19 Parameter values recorded during the test: Vrms at the end of test (Volt): 229.89 Highest dt (%): 0.51 Test limit (%): 3.30 Pass Time(mS) > dt: 0.0 Test limit (ms): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.35 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.210 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.092 Test limit: 0.650 Pass

Page 23 of 39 7. EN 61000-6-4 MEASUREMENT INSTRUMENTATION 7.1 Electrostatic Discharge Test System An ESD simulator is used for all testing. It is capable of applying Electrostatic discharges in both contact discharge modes to 4 kv and air discharge modes to 8 kv in both positive and negative polarities. This is in accordance with the IEC 61000-4-2 basic EMC publication. 7.2 Radiated Susceptibility Test System An signal generator and a Amplifier Research power amplifier are used to provide a signal at the appropriate power and frequency to a transmitting antenna to obtain the required electromagnetic field at the position of the EUT in accordance with the IEC 61000-4-3 basic EMC publication. The field was monitored by Amplifier Research field probe and Amplifier Research PM2002 power meter according the IEC 61000-4-3 standards. In order to judge the performance of the EUT, a set of monitor system is used. 7.3 Electrical Fast Transient/Burst Immunity Test System An Pro PLUS Capacitive Clamp Immunity test system is used for all testing. It is capable of applying fast transients to the AC line at any phase angle with respect to the AC line voltage wave form and to attached cables via a capacitive coupling clamp in accordance with the IEC 61000-4-4 basic EMC publication. 7.4 Surge Immunity Test System An Pro PLUS Capacitive Clamp Immunity test system is used for all testing. Both positive and negative polarities of voltage up to 2kV were applied to the AC input lines. The coupling network defined in the standard was used. 7.5 Conducted Susceptibility Test System An signal generator and a set of Amplifier Research test system are used for the testing. EUT was tested from 0.15 MHz to 80 MHz with 1kHz sine wave, 80% modulation with 3Vr.m.s. CDN coupling and de-coupling networks and EM clamp was tested. During the tests, injected was applied to power line by using CDNs-6.2.2 method, and I/O lines was injected by using EM clamp injection-6.2.3.method.

Page 24 of 39 7.6 Equipment Test Table IEC 61000-4-2: 1995 specifies that a tabletop EUT shall be placed on a non-conducting table which is 80 centimeters above a ground reference plane and that floor mounted equipment shall be placed on a insulating support approximately 10 centimeters above a ground plane. During the tests, the EUT is positioned over a ground reference plane in conformance with this requirement. For tabletop equipment, a 1.6 by 0.8-meter metal sheet (HCP) is placed on the table and connected to the ground plane via a metal strap with two 470 k Ohms resistors in series. The EUT and attached cables are isolated from this metal sheet by 0.5-millimeter thick insulating material. A Vertical Coupling Plane (VCP) grounded on the ground plane through the same configuration as in the HCP is used. IEC 61000-4-3 and IEC 61000-4-4 specify that a tabletop EUT be placed on a non-conducting table 80 centimeters above a ground reference plane and that floor-mounted equipment shall be placed on an insulating support approximately 10 centimeters above a ground plane. During the IEC 61000-4-3 tests, the EUT is positioned on a table in a shielded semi-anechoic test chamber to reduce reflections from the internal surfaces of the chamber. During the IEC 61000-4-4 tests, the EUT is positioned on a table over a ground reference plane in conformance with this requirement. 7.7 Instrument Calibration All test equipment is regularly checked to ensure that performance is maintained in accordance with the manufacturer's specifications. Extensive engineering efforts have been made to ensure test data reliability through Quality Control and regular equipment calibration schedules. However, the application of radio frequency fields and voltages are not without an unavoidable level of uncertainty. These include inaccuracies in antenna factors, chamber imperfections and possible test generator output uncertainties.

Page 25 of 39 8. EN 61000-6-4 TEST PROCEDURES 8.1 EUT and Cable Placement The EUT and any peripherals are located at the center of the table for tabletop devices and in the center of the ground plane with the insulating support for floor-standing devices. The standards require that interconnecting cables to be connected to available ports of the unit and that the placement of the unit and the attached cables simulate a typical installation so far as to be practical. 8.2 Application of Electrostatic Discharge Immunity Test The test is conducted in the following order according to the basic standard IEC 61000-4-2: Air Discharge, Direct Contact Discharge, Indirect Contact Horizontal Coupling Plane Discharge, and Indirect Contact Vertical Coupling Plane Discharge. The Electrostatic Discharge test levels are set and discharges for the different test modes are set appropriately. The Electrostatic Discharge is applied to the conductive surface of the computer in which the EUT is enclosed, and along all seams and control surfaces on the computer. When a discharge occurs and an error is caused, the type of error, discharge level and location is recorded. 8.3 Application of Radiated Susceptibility Test The electromagnetic field is established at the front edge of the EUT. The frequency range is swept from 80 to 1000 MHz using a power level necessary to obtain a 3 volt/meter and 80% amplitude of a 1 khz sine wave modulated field Strength is directed at the EUT. The test is performed with each of four sides of EUT facing the transmitting antenna. If an error is detected when the susceptible side of the EUT facing the transmitting antenna, the field is reduced until the error is not repeatable, the field is then manually increased until the error begins to occur. This threshold level, the frequency and the error created are noted before continuing. Both horizontal and vertical polarization of the antenna are set on test and measured individually 8.4 Application of Electrical Fast Transient/Burst Immunity Test The EUT was arranged for Power Line Coupling and for I/O Line Coupling through a capacitive clamp, where applicable. (Note: The I/O coupling test using a capacitive clamp is performed on the I/O interface cables that are longer in length than 3 meters.) A metal ground plane 2.4 meter by 2.0 meter was placed between the floor and the table and is connected to the earth by a 2.0 meter ground rod. The ground rod is connected to the test facility s electrical earth. 8.5 Application of Surge Immunity Test The EUT was setup as described in IEC 61000-4-5 and the test shall be performed according to the test plan. 8.6 Application of Conducted Susceptibility Test The EUT was setup according to the IEC 61000-4-6 and the test shall be performed with the test generator connected to each of the coupling and decoupling devices in turn while the other nonexcited RF input ports of the coupling devices are terminated by a 50 load resistor. The frequency range is 150kHz to 80 MHz. 8.7 Deviations from the Standard No deviations from EN 61000-6-4 were made when performing the tests described in this report.

Page 26 of 39 9. TEST DATA The EUT will be used in the second environment. According to the EN 61000-6-4 requirements, the following tests use minimum immunity requirements in the second environment. 9.1 Electrostatic Discharge Immunity Test (IEC 61000-4-2) Temperature ( ) 22 Humidity ( %RH ) 58 Barometric Pressure ( mbar ) 1001.1 EUT CNC ROUTER M/N HY-3040 Operating Mode On Mode Table 1: Electrostatic Discharge Immunity (Air Discharge) IEC 61000-4-2 Test Points Test Levels -2 kv +2 kv -4 kv +4 kv -6 kv +6 kv -8 kv +8 kv -15 kv +15 kv Slots 10 points A A A A A A A A / / Switch 10 points A A A A A A A A / / Screen 10 points A A A A A A A A / / Table 3: Electrostatic Discharge Immunity (Indirect Contact HCP) IEC 61000-4-2 Test Points Test Levels -2 kv +2 kv -4 kv +4 kv -6 kv +6 kv -8 kv +8 kv -15 kv +15 kv Front Side A A A A / / / / / / Back Side A A A A / / / / / / Left Side A A A A / / / / / / Right Side A A A A / / / / / / Table 4: Electrostatic Discharge Immunity (Indirect Contact VCP) IEC 61000-4-2 Test Points Test Levels -2 kv +2 kv -4 kv +4 kv -6 kv +6 kv -8 kv +8 kv -15 kv +15 kv Front Side A A A A / / / / / / Back Side A A A A / / / / / / Left Side A A A A / / / / / / Right Side A A A A / / / / / /

Page 27 of 39 9.2 Radiated Susceptibility Test (IEC 61000-4-3) Temperature ( ) 22 Humidity ( %RH ) 57 Barometric Pressure ( mbar ) 1001.1 EUT CNC ROUTER M/N HY-3040 Operating Mode On Mode 9.2.1 Frequency Range (MHz): 80~1000MHz Modulation: Amplitude 80%, 1kHz sine wave Severity Level: 10V/m Frequency Range (MHz) 80-1000 Front (10 V/m) Rear (10 V/m) Left Side (10 V/m) Right Side (10 V/m) VERT HORI VERT HORI VERT HORI VERT HORI A A A A A A A A 9.2.2 Frequency Range (MHz): 1400~2000MHz Modulation: Amplitude 80%, 1kHz sine wave Severity Level: 3V/m Frequency Range (MHz) 1400-2000 Front (3 V/m) Rear (3 V/m) Left Side (3 V/m) Right Side (3 V/m) VERT HORI VERT HORI VERT HORI VERT HORI A A A A A A A A 9.2.3 Frequency Range (MHz): 2000~2700MHz Modulation: Amplitude 80%, 1kHz sine wave Severity Level: 1V/m Frequency Range (MHz) 2000-2700 Front (1 V/m) Rear (1 V/m) Left Side (1 V/m) Right Side (1 V/m) VERT HORI VERT HORI VERT HORI VERT HORI A A A A A A A A

Page 28 of 39 9.3 Electrical Fast Transient/Burst Immunity Test (IEC 61000-4-4) Temperature ( ) 22 Humidity ( %RH ) 57 Barometric Pressure ( mbar ) 1001.1 EUT CNC ROUTER M/N HY-3040 Operating Mode On Mode IEC 61000-4-4 Test Levels (kv) Test Points +0. 5-0. 5 +1.0-1.0 +2.0-2.0 +4.0-4.0 Power Supply Power Line of EUT L1 A A A A A A / / L2 / / / / / / / / L3 / / / / / / / / N A A A A A A / / Earth A A A A A A / / L1 + L2 / / / / / / / / L1 + L3 / / / / / / / / L2 + L3 / / / / / / / / L1 + N A A A A A A / / L2 + N / / / / / / / / L3 + N / / / / / / / / L1 + Earth A A A A A A / / L2 + Earth / / / / / / / / L3 + Earth / / / / / / / / N + Earth A A A A A A / / L1 + L2 + L3 / / / / / / / / L1 + L2 + N / / / / / / / / L1 + L2 + Earth / / / / / / / / L1 + L3 + N / / / / / / / / L1 + L3 + Earth / / / / / / / / L1 + N + Earth A A A A A A / / L2 + L3 + N / / / / / / / / L2 + L3 + Earth / / / / / / / / L2 + N + Earth / / / / / / / / L3 + N + Earth / / / / / / / / L1+L2+L3+N / / / / / / / / L1+L2+L3+Earth / / / / / / / / L1+L2+N+Earth / / / / / / / / L1+L3+N+Earth / / / / / / / / L2+L3+N+Earth / / / / / / / / L1+L2+L3+N+ Earth / / / / / / / /

Page 29 of 39 9.4 Surge Immunity Test (IEC 61000-4-5) Temperature ( ) 22 Humidity ( %RH ) 57 Barometric Pressure ( mbar ) 1001.1 EUT CNC ROUTER M/N HY-3040 Operating Mode On Mode Table 1: Surge Power Supply Level Voltage Poll Path Pass Fail 1 0.5kV ± L-N A / 2 1kV ± L-N A / 3 2kV ± L-PE, N-PE A / 4 4kV ± / / / 9.5 Conducted Susceptibility Test (IEC 61000-4-6) Frequency Range (MHz): 0.15~80MHz Modulation: Amplitude 80%, 1kHz sine wave Severity Level: 10Vr.m.s. Temperature ( ) 22 Humidity ( %RH ) 57 Barometric Pressure ( mbar ) 1001.1 EUT CNC ROUTER M/N HY-3040 Operating Mode On Mode Level Voltage Level (e.m.f.) U 0 Pass 1 1 / / 2 3 / / 3 10 A / X Special / / Fail Note: A. The apparatus shall continue to operate as intended during and after the test. The manufacturer specifies some minimum performance level. The performance level may be specified by the manufacturer as a permissible loss of performance. B. The apparatus shall continue to operate as intended after the test. This indicates that the EUT does not need to function at normal performance levels during the test, but must recover. Again some minimal performance is defined by the manufacture. No change in operating state or loss or data is permitted. C. Temporary loss of function is allowed. Operation of the EUT may stop as long as it is either automatically reset or can be manually restored by operation of the controls.

Page 30 of 39 10. TEST RESULTS The following tests were performed on the Shenzhen Scotle Technology Ltd s product; model: HY-3040; the actual test results are contained within the Test Data section of this report. 10.1 IEC 61000-4-2 Electrostatic Discharge Immunity Test Configuration The EUT was subjected to the electrostatic discharge tests required by EN 61000-6-4 and all lower levels specified in IEC 61000-4-2. The EUT continued to perform as intended during and after the application of the ESD. Test setup photographs presented in Appendix B. 10.2 IEC 61000-4-3 Radiated Susceptibility Test Configuration The EUT was subjected to a 3-volt/meter, 80% Amplitude, 1 khz Sine wave field as required by EN 61000-6-4 and all lower levels specified in IEC 61000-4-3. The EUT continued to perform as intended during and after the application of the electromagnetic field. Test setup photographs presented in Appendix B. 10.3 IEC 61000-4-4 Electrical Fast Transient/Burst Immunity Test Configuration The EUT was subjected to the electrical fast transient tests required by EN 61000-6-4 and all lower levels specified in IEC 61000-4-4. The EUT continued to perform as intended during and after the application of the EFT/B. Test setup photographs presented in Appendix B. 10.4 IEC 61000-4-5 Surge Immunity Test Configuration The EUT was subjected to the Surge Immunity tests required by EN 61000-6-4 and all lower levels specified in IEC 61000-4-5. The EUT continued to perform as intended during and after the application of the Surge Immunity Test. Test setup photographs presented in Appendix B. 10.5 IEC 61000-4-6 Conducted Susceptibility Test Configuration The EUT was subjected to the Conducted Susceptibility tests required by EN 61000-6-4 and all lower levels specified in IEC 61000-4-6. The EUT continued to perform as intended during and after the application of the Conducted Susceptibility Test. Test setup photographs presented in Appendix B. 10.6 IEC 61000-4-11 Voltage Dips, Short Interruptions Immunity Tests Configuration The EUT was subjected to the Voltage Dips/Interruptions tests required by EN 61000-6-4 and all lower levels specified in IEC 61000-4-11. The EUT continued to perform as intended during and after the application of the Voltage Dips/Interruptions. Test setup photographs presented in Appendix B.

Page 31 of 39 APPENDIX A. EUT PHOTOGRAPHS EUT - Front View EUT - Back View

Page 32 of 39 EUT - Inside View EUT - Inside View

Page 33 of 39 EUT - Inside View EUT - Inside View

Page 34 of 39 EUT - Inside View EUT - Inside View

Page 35 of 39 EUT - Inside View EUT - Inside View

Page 36 of 39 EUT - Inside View EUT - Inside View

Page 37 of 39 APPENDIX B. TEST SETUP PHOTOGRAPHS Conducted Emission Radiated Emission

Page 38 of 39 Radiated Susceptibility Test Harmonic & Voltage Fluctuations and Flicker Test

Page 39 of 39 Electrostatic Discharge Immunity Test Electrical Fast Transient/Burst & Voltage Dips, Short Interruptions & Surge Immunity Test