100G EPON Downstream wavelength plan

Similar documents
SOA pre-amplified upstream signal power in 100G EPON

Consideration about wavelength allocation in O-band

Marek Hajduczenia, ZTE Corp.

WaveReady 40- and 44-Channel Multiplexer/ Demultiplexer with Test Channel. MDX-40MD101CB and MDX-44MD101CB

Fiber-based components. by: Khanh Kieu

CWDM Cisco CWDM wavelengths (nm)

Four-wave mixing in O-band for 100G EPON John Johnson

50Gb/s technical feasibility analysis. Dekun Liu, Huawei Stanley Shuai, Source Sep, 2017

Putting the D back into DWDM Full-band Multi-wavelength Systems Mani Ramachandran CEO / CTO InnoTrans Communications

Specification for 100GBASE-DR4. Piers Dawe

Super-PON. Scale Fully Passive Optical Access Networks to Longer Reaches and to a Significantly Higher Number of Subscribers

IEEE July 2001 Plenary Meeting Portland, OR Robert S. Carlisle Sr. Market Development Engineer

PERFORMANCE EVALUATION OF GB/S BIDIRECTIONAL DWDM PASSIVE OPTICAL NETWORK BASED ON CYCLIC AWG

Proposal for 4-channel WDM (WDM4) for intermediate reach 100GbE SMF PMD

NG-PON2 Optical Components Update. Hal Roberts System Architect

PAM-4 Four Wavelength 400Gb/s solution on Duplex SMF

Further considerations on objectives for PHYs running over point-to-point DWDM systems

Mahendra Kumar1 Navneet Agrawal2

OPC1600 MUX WDM OADM SPLITTER

OMxxDyy-100zz-ab:cd-(M5)-XXYY

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 8 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

Novel Design of Long Reach WDM-PON by using Directly Modulated RSOA

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 4 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

Module 19 : WDM Components

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Enhanced 10 Gb/s operations of directly modulated reflective semiconductor optical amplifiers without electronic equalization

Cisco s CLEC Networkers Power Session

WWDM Transceiver Module for 10-Gb/s Ethernet

Implementation of Dense Wavelength Division Multiplexing FBG

Optical Transport Technologies and Trends

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Overview. Highlights. General Specification. Datasheet

Design and Performance Evaluation of 20 GB/s Bidirectional DWDM Passive Optical Network Based on Array Waveguide Gratings

Presentation Overview

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Basic Optical Components

Wavelength Multiplexing. The Target

Experimental Demonstration of 56Gbps NRZ for 400GbE 2km and 10km PMD Using 100GbE Tx & Rx with Rx EQ

A comment on Table 88-7 and 88-8 in Draft 1.0

CFORTH-QSFP28-100G-LR4 Specifications Rev. D00B. Product Features

11.1 Gbit/s Pluggable Small Form Factor DWDM Optical Transceiver Module

DATASHEET FMU-MC04E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

Lecture 2. Introduction to Optical. Ivan Avrutsky, ECE 5870 Optical Communication Networks, Lecture 2. Slide 1

Optical Passives (ISP)

Colorless Amplified WDM-PON Employing Broadband Light Source Seeded Optical Sources and Channel-by-Channel Dispersion Compensators for >100 km Reach

Cisco QSFP-100G-LR4-S. Part Number: QSFP-100G-LR4-S QSFP-100G-LR4-S OVERVIEW PRODUCT FEATURES APPLICATIONS. FluxLight, Inc

Chapter 10 WDM concepts and components

4x25-Gb/s 40-km 1310-nm PMD with SOA Pre-Amplifier: Impact of Channel Spacing

FMU-MC09-A/B, Pair Packaged DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Evolution from TDM-PONs to Next-Generation PONs

UNIT - 7 WDM CONCEPTS AND COMPONENTS

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform

Downstream Transmission in a WDM-PON System Using a Multiwavelength SOA-Based Fiber Ring Laser Source

Proposal for 400GE Optical PMDs for SMF Objectives based on 4 x 100G DMT David Lewis, Sacha Corbeil, Beck Mason

Headend Optics Platform (CH3000)

Dr. Monir Hossen ECE, KUET

PR-12-B-M. 12 GHz PhotoReceiver, Module. Features. Applications. Functional Diagram

50/100 GHz, 100/200 GHz Passive Interleavers. IBC Series

Annex 91A Coexistence of 1 Gb/s (symmetric), 10 Gb/s (symmetric) and 10/1 Gb/s (asymmetric) Ethernet Passive Optical Networks (EPONs)

GT Channel Ultra Compact CWDM Mux & DeMux

WHITE PAPER LINK LOSS BUDGET ANALYSIS TAP APPLICATION NOTE LINK LOSS BUDGET ANALYSIS

An Amplified WDM-PON Using Broadband Light Source Seeded Optical Sources and a Novel Bidirectional Reach Extender

SOA-PIN performance. Rene Bonk, Dora van Veen, Vincent Houtsma, Bell Labs Ed Harstead, member Fixed Networks CTO. January 2017

Optical Fiber Technology

80 GBPS DOWNSTREAM TRANSMISSION USING DQPSK AND 40 GBPS UPSTREAM TRANSMISSION USING IRZ/OOK MODULATION IN BIDIRECTIONAL WDM-PON

DATASHEET 4.1. QSFP, 40GBase-LR, CWDM nm, SM, DDM, 6.0dB, 10km, LC

SOA preamp performance: theoretical modeling

A WDM passive optical network enabling multicasting with color-free ONUs

40Gb/s Optical Transmission System Testbed

Long-Haul DWDM RF Fiber Optic Link System

Limits to the Exponential Advances in DWDM Filter Technology? Philip J. Anthony

Performance Analysis of WDM RoF-EPON Link with and without DCF and FBG

DATASHEET FMU-MC04E-A/B, Pair Packaged, w/expansion Port

XM40-QD20LD-J 40-ch Multiplexer/Demultiplexer

Introduction of 25 Gb/s VCSELs

Fast, Two-Dimensional Optical Beamscanning by Wavelength Switching T. K. Chan, E. Myslivets, J. E. Ford

WaveSmart Wave Division Multiplexing (WDM)

EDFA Applications in Test & Measurement

100G CWDM4 MSA Technical Specifications 2km Optical Specifications

40GBd QSFP+ LR4 Optical Transceiver

Minutes 802.3av 10G EPON Task Force Plenary Meeting Dallas, TX

DATASHEET FMU-MD08E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

Coexistence of 1 Gb/s (symmetric), 10 Gb/s (symmetric) and 10/1 Gb/s (asymmetric) Ethernet Passive Optical Networks (EPONs)

A HIGH SPEED WDM PON FOR DOWNSTREAM DPSK ASK SIGNALS AND UPSTREAM OOK SIGNAL WITH BROADCAST CAPABILTY

100Gbs QSFP28 LR4 Optical Transceiver Module WT-QSFP28-LR4

Integrated TOSA with High-Speed EML Chips for up to 400 Gbit/s Communication

40G-BASE-LR4 10km QSFP+ Optical Transceiver GTR3QP1L

DATASHEET 4.1. XFP, 10GBase-ZR, Multirate Gbps, DWDM 50GHz, SM, DDM, 24dB, 80km

WaveReady Multi-Degree Reconfigurable Optical Add/Drop Multiplexer WRS-05AD1C00B

LEAD Fiber Optics PRODUCT CATALOGUE

Physical Layer. Dr. Sanjay P. Ahuja, Ph.D. Fidelity National Financial Distinguished Professor of CIS. School of Computing, UNF

Enabling technology for suppressing nonlinear interchannel crosstalk in DWDM transoceanic systems

Long-wavelength VCSELs ready to benefit 40/100-GbE modules

P2MP PMD Baseline. Prepared by Frank Effenberger Quantum Bridge Communications

Wavelength-Enhanced Passive Optical Networks with Extended Reach

WDM Alternatives for 100Gb SMF Applications

Transcription:

Downstream wavelength plan Hanhyub Lee Hwan Seok Chung IEEE P802.3ca - Task Force Vancouver, BC Canada March 12-17, 2017 2017-03-13 IEEE 802 Plenary session

O-band wavelength plan was accepted at Huntington Beach meeting, but wavelength plans for downstream and upstream are still unsettled There are some considerations in deciding the downstream wavelength plan in cost aspect of transceiver implementation 1 2 3 4 US/DS GAP for single λ BOSA Channel bandwidth for wavelength blocking filter TDP of 25 Gb/s downstream signal Etc It is clear that 25G transceiver of first channel will use single λ BOSA to ensure cost effectiveness and convenience Adoption of single λ BOSA imposes two constraints on the wavelength plan 1 US/DS GAP should be larger than 50 nm 2 The bandwidth for first λ should be over 10 nm It is not clear that transceivers for will use BOSA or not. Question: Is it inevitable to apply the single λ BOSA constraints to the other channels? 2017-03-13 IEEE 802 Plenary session Page 2

Funada_3ca_1_0117.pdf Input DS: λ0 ~ λ3 Fiber Band splitting filter Output US: λ0 λ0 ~ λ3 TOSA λ0 Blocking filter johnson_3ca_1a_0916.pdf λ0 ROSA 2017-03-13 IEEE 802 Plenary session Page 3

Upstream wavelength Downstream wavelength US0 US1 US2 US3 Zero dispersion window (1300 nm ~ 1324 nm) ~20 nm DS0 DS1 DS2 DS3 800 GHz Gap btw up/down: 50 nm 800 GHz Wavelength (nm) Ch0 Ch1 Ch2 Ch3 Note Upstream (nm) 1289.71 1294.16 1298.65 1303.16 800 GHz channel spacing Downstream (nm) 1339.85 1351.94 1356.83 1361.76 800 GHz channel spacing for Ch1, Ch2, and Ch3 Gap (nm) 50.15 57.78 58.19 58.60 TDP (db) 0.5 0.7 0.7 0.8 umeda_3ca_1_0316 All transceivers use BOSAs with 50 nm GAP btw US and DS Bandwidth of the first DS signal(ds0) is 20 nm for relaxed blocking filter The last DS signal wavelength is longer than the upper limit of O-band ( Original O-band, 1260 nm to 1360 nm) 2017-03-13 IEEE 802 Plenary session Page 4

OT0 Single λ BOSA OT0 25G OLT OT1 OT2 OT3 Band splitter/combiners DS US 1x4 splitter/combiners (insertion loss ~7 db) Fiber Splitter 1x4 splitter/combiner (Insertion loss ~ 7dB) OT0 OT1 OT2 OT3 All transceivers are implemented with Single λ BOSAs 1x4 splitters are used to multiplex and demultiplex DS and US signals Extra insertion loss is ~ 14 db from two 1x4 splitter/combiners Optical amplifiers can compensate the extra loss but an launched downstream power/ channel to the fiber should be over + 11 dbm considering 29-dB link budget, 7-dB 1x4 combiner loss and -24.2 dbm of receiver sensitivity 2017-03-13 IEEE 802 Plenary session Page 5

MUX DeMUX OLT OT0 OT1 OT2 OT3 Single λ BOSA MUX DeMUX Fiber Splitter Single λ BOSA OT0 OT0 OT1 OT2 25G External diplexers/combiners Band splitter/combiners External diplexers/combiners OT3 All transceivers are implemented with Single λ BOSAs External band splitter/combiners are needed to separate downstream and upstream signal after each transceiver at both OLT and This will make the BOSA s role unclear 2017-03-13 IEEE 802 Plenary session Page 6

MUX DeMUX OLT OT0 OT1 OT2 OT3 Duplex in/out 25G transceiver uses a single λ BOSA MUX External diplexers/combiners Band splitter/combiners DeMUX Fiber Splitter Duplex in/out External diplexers/combiners Each 25G transceiver for uses duplex in/out configuration rather than BOSA configuration in order to reduce redundant band splitters/combiners and insertion loss The external band splitters are implemented by a thin film filter and optical collimators. So, GAP can be relaxed from 50 nm to 20 nm OT0 OT0 OT1 OT2 OT3 25G 2017-03-13 IEEE 802 Plenary session Page 7

DeMUX MUX OLT OT0 OT1 OT2 OT3 Duplex in/out 25G transceiver uses a single λ BOSA MUX External diplexers/combiners Band splitter/combiners DeMUX Fiber Splitter Multi λ BOSA transceiver use multi λ BOSA to simplify PMD configuration It is the simplest implementation case, but array optical / electrical components are required The external band splitters are implemented by a thin film filter and optical collimators. So, GAP can be relaxed from 50 nm to 20 nm OT0 Array TOSA 0 1 2 3 0 1 2 3 Array ROSA OT 25G 2017-03-13 IEEE 802 Plenary session Page 8

Upstream wavelength Downstream wavelength Zero dispersion window ~20 nm US0 US1 US2 US3 (1300 nm ~ 1324 nm) DS3 DS2 DS1 DS0 800 GHz ~ 20 nm ~ 55 nm 800 GHz Wavelength (nm) Ch0 Ch1 Ch2 Ch3 Note Upstream (nm) 1289.71 1294.16 1298.65 1303.16 800 GHz channel spacing Downstream (nm) 1344.36 1332.41 1327.69 1323.00 800 GHz channel spacing for Ch1, Ch2, and Ch3 Gap 54.65 38.25 29.04 19.84 TDP (db) 0.6 0.4 0.4 0.3 umeda_3ca_1_0316 The first downstream channel (DS0) has 20-nm channel bandwidth for relaxed 25G blocking filter and maximum GAP is 55 nm between DS0 and US0 which will minimize excess loss (ref. Funada_3ca_1_0117.pdf) Minimum GAP is set to 20 nm between DS3 and US3 This plan will minimize TDPs of 25 Gb/s downstream signals 2017-03-13 IEEE 802 Plenary session Page 9

Wavelength plans are discussed as considerable implementation scenarios of transceivers for 25G and If all 25G transceivers use BOSA then redundant optical components will be required and also extra loss will be added To reduce redundancy, it seems that transceivers for do not need to use single λ BOSA Duplex configuration is simpler than BOSA configuration in transceiver implementation Wavelength plan II will be better than wavelength plan I in terms of TDP 2017-03-13 IEEE 802 Plenary session Page 10