LB115S 115W Single Output

Similar documents
TB65 65W Single Output Test and Measurement/Industrial Series

TE90 90W Single Output External Power Test & Measurement/Industrial Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE60 60W Single Output External Power Test & Measurement/Industrial Series

TE W Single Output External Power Test & Measurement/Industrial Series

TE40 40W Single Output External Power Test & Measurement/Industrial Series

MB120S 120W Single Output Medical Series

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

General. Environmental. EMC & Safety

FEATURES AND BENEFITS. Compact size: 6.5 x 2.8 x 1.5

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

C B. Models. Models 2MOPP

Electrical Specifications

150 Watt Industrial (WLT)

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

LFWLP W 12V 15.00A 25.00A 92%

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

Electrical Specifications

PDAM500 Series 500W Power Supply

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

VOF XX - XXX - X

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

Ripple & Max. capacitive Output Current

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Doc. EA Model Number:

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

For more information, please visit the product page. output. output current max (A)

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Industrial Serie +600S

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Output Voltage* (nom.)(adjustable)

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Electrical Specifications

Ordercode Output Power Output 1 Output 2 Output 3 PCB-mounting Chassis mounting max. with solder pins with screw terminals

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

HEC-45LTN-45PFAS Rev A

POWER. NLP40 Series. Single, Dual and Triple Output. Data Sheet

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

HEC-30/35LTA-33TDAA Rev A

Line Reg Load Reg Ripple Efficiency *Model Number Output V Output I (nom/max) (nom/max) & Noise (min/nom)

Output Full Load

HEC-100RTA-48QSCA Rev A1.0

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

3 in 1 Dimmable (0-10Vdc, PWM signal, or resistance)

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC

Metal Case Power Supplies

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

HEC-35LTA-XXTSAA Rev A

Efficiency (typ.) (Range) Load. Output Current Input Current Reflected Ripple

Encapsulated Power Supply

50W Constant Current (700mA) Dimming LED Driver

CB Scheme UL508 UL ATEX II3G

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

75W Constant Current (700mA) LED Driver

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Model Number Output V1/V2/V3 Output I1/I2/I3 max. Ripple & Noise Efficiency(min/nom) Capacitive Load

QUARTER-BRICK SERIES Single Output Performance Products

VLM60/40 Series. 60 & 40 W, Efficient, Compact Constant Voltage Class 2 LED Drivers

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Transcription:

Features Small size of 2 x 4 x 1.3 75W convection cooled/115 Watts with 200 LFM Universal Input 90-264Vac Meets EN55015 Conducted EMI Meets IEC61000-3-2 Class C for less than 1 Watt to full power Approved to UL/CSA/IEC/EN60950-1, 2 nd Edition Level V Efficiency Compliant -40 C start up -20 C to 70 C Operating temperature Range 3 Year Warranty Optional LED indicator for power-on Description The LB115S provide a reliable power source with high power density in 2 x 4 x 1.3 package. Fully compliant to the applicable safety and Global Lighting EMC standards, these models will allow easy integration into many Lighting fixtures and other industrial applications. All 4 models are CE marked to low voltage directive and approved to standards of UL/CSA/IEC/EN60950-1 2 nd edition. Model Selection Model Output Current Output Current Ripple & Total OVP Number Volts Convection Cooled Forced air(200 LFM) (Total Power) Noise* Regulation Threshold LB115S12K 12 V 6.25 A 9.00A 0.5%RMS, ±2% 14.0 ± 1.1V (108 Watts) 1.5% pk-pk LB115S24K 24 V 3.13A 4.58A 0.5%RMS, ±2% 28.0 ± 2.5V (110 Watts) 1% pk-pk LB115S48K 48 V 1.56A 2.40A 0.5%RMS, ±2% 55.0 ± 4.0V (115 Watts) 1% pk-pk LB115S56K 56 V 1.34A 2.05A 0.5%RMS, ±2% 63.0 ± 4.0V (115 Watts) 1% pk-pk Notes: * At -20C, the noise and ripple is 2% of the output. General & Input Specifications AC Input Voltage: AC Input Frequency: AC Input Current: Inrush Current: Earth Leakage Current (Input Earth): 90-264Vac, single phase 47-63Hz 115Vac: 2A, 230Vac: 1A 65A maximum @ 25C <350uA@264Vac, 60 Hz input, NC Input Fuse: F1:4A, 250VAC Fuse provided on all models www.slpower.com LB115S 2-OCT-14 1

Efficiency Typical Measured @ 25 C LB115S12K 89% @230V ac, full load 86.5%@115V ac, full load LB115S24K 89% @230V ac, full load 87%@115V ac, full load LB115S48K 90% @230V ac, full load 88%@115V ac, full load LB115S56K 90% @230V ac, full load 88%@115V ac, full load Operating Temperature Storage Temperature Turn-on Time: Hold-up Time: -20 C to 70 C -40 C to 85 C <2 Seconds @115Vac(<3S for 12V output) 12mS minimum from loss of ac input at 115 Vac -40 C start up (full load) For 12V output, the maximum load is 75% <5 Seconds @115Vac for -20 C ambient DC Output Specifications Output Power: Cooling: Total Regulation: Overload Protection: Short Circuit Protection: Overvoltage Protection: Overtemperature Protection: Minimum Load: Ripple and Noise: Transient Response: Overshoot: Max of 75 Watts for Convection cooled Max of 115 Watts for fan cooled (48 & 56V Models) Convection Forced Air of 200 LFM ±2% for all models 120% - 180% of rated output current value, Hiccup Mode Short across the output terminals will not cause damage to the unit. Hiccup Mode OVP firing reduces output voltage to <50% of nominal in <50mS. See chart for trip range Automatic Power Shutdown No minimum load is required 0.5% RMS, 1% pk-pk for all models. 500µs typ. response time for return to within 0.5% of final value for a 50% load change, i/ t< 0.2A/µs. Max. voltage deviation is 3.5%. 5% overshoot at turn-on, 5% overshoot at turn-off, under all conditions. Maximum 108 Watts for 12V output -20 to 50 C ambient Total regulation is the maximum deviation from nominal voltage for all loading conditions For 12V output, it is 110 to 180% Thermistor temperature is 130 C 20 MHz Bandwidth, differential mode. Measured with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR capacitors Measured @ 25 C 6% for 12V output www.slpower.com LB115S 2-OCT-14 2

Safety Standard Compliance Agency CONDITIONS UL EN/CSA/UL/IEC 60950-1, 2 nd Edition CSA Demko CB Report Isolation Type: CSA 60950-1, 2 nd EN 60950-1, 2nd IEC 60950-1, 2nd Double/Reinforced between Input and Output Isolation Specifications PARAMETER CONDITIONS Rating NOTES Insulation Safety Rating: Electric Strength Test Voltage: Input to Ground Input to Output Input to Ground Input to Output Output to Ground Environmental Specifications Basic Insulation Double/Reinforced 1900Vac 3000Vac 500Vac Operating Temperature: -20 C to +70 C -40 C Startup guaranteed Temperature Derating: 60% derating at 70 C Cooling: Convection/ Airflow 75 Watts convection Storage Temperature: -40 C to +85 C Altitude: Operating: -500 to 3,000 meter Non-operating: -500 to 40,000 ft. Relative Humidity: 5% to 95%, non-condensing Shock: Non-Operating: Half-sine, 40 gpk, 10mS, 3 axes, 6 shocks total Vibration: Random vibration per MIL-STD-810E, Method 514.4, Cat. 1, Figure 514.4-1, 1 hr in each of three axes. Reliability Specifications MTBF: 574K hours, 25 C ambient, full load Calculation is done based on Telcordia. Reports for each model is available Warranty: 3 Years Limited HALT Data: Per SL Power Halt procedure Report is available www.slpower.com LB115S 2-OCT-14 3

EMI/EMC Compliance Conducted Emissions: EN55011/22 Class B; FCC Part 15 Also meets EN55015 Class B Radiated Emissions: Harmonic Current Emissions Voltage Fluctuations & Flicker Static Discharge Immunity: RF Field Susceptibility Fast Transients/Bursts Surge susceptibility Conducted RF susceptibility Power Frequency Magnetic Field Test Voltage Sags & Surges EN55011/22 Class A; FCC Part 15 EN61000-3-2, Class A,B,C &D EN61000-3-3 EN61000-4-2, Level 4: 6kV contact, 8kV air, Criteria A EN61000-4-3, Level 3 (3V/m), Criteria A EN61000-4-4, Level 3 (PS: 2kV-40A, other lines 1kV-20A), Criteria A EN61000-4-5, Installation Class 3 (1kV diff. mode, 2kV common mode), Criteria A EN61000-4-6, Level 3 (3Vrms), Criteria A EN61000-4-8, Level 3 (3A/m), Criteria A EN61000-4-11, 95% dip/0.5 cycle (Criteria A), 60%/5cycles (Criteria B ), 30%/25 cycles (Criteria A). loading is 70% of 100 watts with 100 Vac input. Meets class C from 5 to 115 Watts. This is based on limits set @ 115 Watt Performance criteria are defined as following: A Normal performance during and after the test B Temporary degradation, self-recoverable C Temporary degradation, operator intervention required to recover the operation Notes: 1. Specifications subject to change without notice. 2. Specifications are for convection rating at factory settings with 115Vac input and 25 C ambient unless otherwise stated. www.slpower.com LB115S 2-OCT-14 4

Mechanical Drawing Connector Information PIN 1) AC NEUTRAL PIN 2) EMPTY PIN 3) AC LINE Mating Connector: Tyco/AMP 640250-3 Terminals : 3-640252-1 Input Connector J2 DC Output Connector J3 PIN 1) +Vout PIN 2) +Vout PIN 3) +Vout PIN 4) -Vout PIN 5) -Vout PIN 6) -Vout Mating Connector: AMP 640250-6 Terminals : 3-640252-1 Ground (FG)J1 19-30258-0187 (Keystone 1285) (Zierick 895)(.187*0.020) Mating Connector Molex 190020005 1. All dimensions in inches (mm) undefined tolerance is ±.02 (0.5mm). 2. Mounting holes should be connected together for EMI purpose 3. FG is safety ground connection 4. This power supply requires mounting on metal standoffs 0.20 (5mm) Min. in height www.slpower.com LB115S 2-OCT-14 5

Characteristic Curves Output Power vs. Temperature Efficiency vs. Loading www.slpower.com LB115S 2-OCT-14 6

Ripple & Noise To verify that the output ripple and noise does not exceed the level specified in the product specification, measured using a scope probe socket with 0.1uF ceramic and a 10uF electrolytic capacitor connected in parallel across it, 20MHz BW. Output Overload Characteristic Overvoltage Protection www.slpower.com LB115S 2-OCT-14 7

Turn On Time Hold Up Time CH1: Vout Vin: 115 Vac CH3: Vin Iout: 2.40 Amps Min_Limit: 16 Meas: 23.2 ms Data Sheet 2014 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com LB115S 2-OCT-14 8