IAS Accreditation Number Company Name CL-154 Almeer Technical Services Calibration Laboratory Address Plot No. 100/104, Area 7 P.O. Box 9240 Ahmadi, 61003 Kuwait Contact Name Satyananda Rao, Technical Manager Telephone +965-1840-800 x225 Effective Date of Scope March 20, 2017 Accreditation Standard ISO/IEC 17025:2005 CALIBRATION TECHNIQUE, REFERENCE STANDARD, External Micrometer- Metric Calipers(Dial/Ver nier/digital) Dial Gauge Plunger Tape & Scale Calibrator Measuring Tape & Scale Indicating Instruments both Analog & Digital (Pneumatic) Indicating Instruments both Analog & Digital (Hydraulic) Vacuum Indicating Instruments both Analog & Digital Dimensional Up to 25 mm/ 0.001 mm 2.0 µm 0 mm to 100 mm/ 0.01 mm 7.4 μm 100 mm to 300 mm/ 0.01 mm 10 μm Reference gauge blocks & Long gauge blocks 300 mm to 600 mm/ 0.01 mm 14 μm 0 mm to 600 mm/ 0.01 mm 15 μm Caliper Checker 0 mm to 600 mm/ 0.02 mm 19 μm (Mitutoyo) 25 mm/ 0.001 mm 2.0 µm 25 mm/ 0.01 mm 6.0 µm Up to 2000 mm/0.005 mm (4.2 + 3.8*L) µm Up to 2000 mm (11 + 3.2*L) µm 2001 mm to 10000 mm (12.2+2.8*L)µm Above 10000 mm (29+1.2*L)µm Mechanical 0.2 bar to 30 bar/ 0.01 bar 10 bar to 60 bar/ 0.01 bar 60 bar to 800 bar/ 0.20 bar -10075 mm WC to 0 mm WC/ 25.5 mm WC (0.0025 bar) Analog 0.1% IR Digital 0.01% IR Analog 0.1% IR Digital 0.01% IR 0.015% IR Dial Calibration Tester Reference Gauge Blocks Grade 0 & Grade 1 Lever Dial Gauge (0.001mm) Measuring Tape & Scale Calibrator Steinmyer BMG 2000 DH-Budenberg DH-Budenberg DH-Budenberg with motorized pump Page 1 of 7
(Pneumatic) (Pneumatic) (Hydraulic) Vacuum Analogue and Digital Transducer, Indicator / Vacuum Torque Tachometer non contact type Analytical, Laboratory and industrial weighing Balances DC Voltage - AC Voltage - 0.2 bar to 30 bar/ 0.01 bar 0.44% IR 10 bar to 60 bar/ 0.01 bar 60 bar to 500 bar/ 0.20 bar -10075 mm WC to 0 mm WC/ 25.5 mm WC (0.0025 bar) up to 40000 psi/ 0.001 psi up to 40000 psi/ 500 psi 0.15% IR 0.1% IR 0.07% IR 0.8% IR DH-Budenberg, HART Communicator and HP 6 ½ Digit DH-Budenberg, HART Communicator and HP 6 ½ Digit DH-Budenberg, HART Communicator and HP 6 ½ Digit DH-Budenberg Dead Weight Tester 40,000psi -1 bar to 2 bar/ 0.0001 bar 0.016% IR Calibrator GE Druck Pace 1000 up to 30 N-m/ 0.2 N-m 0.2 N-m Norbar Torque Tool Up to 60 N-m/ 0.5 N-m 0.35 N-m Tester 1.2to 60Nm, >60 Nm to 110 N-m/ 0.5 N-m 0.44 N-m up to 700 N-m/ 2.5 N-m 1.92 N-m Norbar Torque Tool up to 1500 N-m/ 10 N-m 6.3 N-m Tester 30 to 1500Nm, Up to 3000 N-m/ 20 N-m 15 N-m 60 rpm to 999.9 rpm/ 0.1 rpm 0.08 rpm 00 rpm to 99999 rpm/ 1 rpm 1.0 rpm up to 220 g/ 0.1 mg 0.3 mg Norbar Torque Tool Tester 300 to 3000Nm Fluke 5522A Troemner ASTM E617Class1 Standard weight set 1mg to 200g up to 10 kg/ 0.1 g 50 mg Mettler Toledo OIML >10 kg to 60 kg/ 0.1 g 200 mg Class F1 Standard Weight set 1g to 60kg Electrical/DC/Low Frequency up to 100 mv/ 0.001 mv 2.4 µv up to 1 V/ 0.01 mv 12 µv 123 µv 16 mv Page 2 of 7
60 Hz 1kHz 10kHz 100kHz DC Current - AC Current - 60 Hz 1 khz up to 100 mv/ 0.001 mv 18 µv up to 1 V/ 0.01 mv 163 µv 16 mv 183 mv up to 100 mv/ 0.001 mv 18 µv up to 1 V/ 0.01 mv 163 µv 16 mv 183 mv up to 100 mv/ 0.001 mv 18 µv up to 1 V/ 0.01 mv 163 µv 20 mv 182 mv up to 100 mv/ 0.001 mv 87 µv up to 1 V/ 0.01 mv 640 µv 8.3 mv 194 mv up to 10 µa/ 0.1 na 22 na up to 100 µa/ 1 na 35 na up to 1 ma/ 0.1 µa 139 na up to 10 ma/ 1 µa 1.1 µa >10 ma to 100 ma/ 1 µa 9.7 µa up to 1 A/ 0.01 ma 186 µa up to 2.5 A/ 0.1 ma 770 µa up to 10 A/ 1 ma 4.4 ma >10 A to 20 A/ 1 ma 16 ma up to 100 µa/ 0.01 µa 175 na up to 1 ma/ 0.1 µa 893 na up to 10 ma/ 0.001 ma 4.7 µa up to 100 ma/ 0.01 ma 47 µa >100 ma to 1A/ 0.01 ma 475 µa up to 2.5 A/ 0.1 ma 1.2 ma up to 10 A/ 1 ma 6.2 ma >10 to 20 A/ 1 ma 22.6 ma up to 100 µa/ 0.01 µa 175 na up to 1 ma/ 0.1 µa 893 na up to 10 ma/ 0.001 ma 4.8 µa up to 100 ma/ 0.01 ma 47 µa >100 ma to 1 A/ 0.01 ma 475 µa up to 2.5 A/ 0.1 ma 1.2 ma Page 3 of 7
10 khz Resistance - Capacitance - Frequency - DC Current clamp AC Current clamp up to 10 A/ 1 ma 9.3 ma >10 A to 20 A/ 1 ma 27 ma up to 100 µa/ 0.01 µa 775 na up to 1 ma/ 0.1 µa 8.2 µa up to 10 ma/ 0.001 ma 48 µa up to 100 ma/ 0.01 ma 475 µa >100 ma to 1 A/ 0.01 ma 23 ma up to 2.5 A/ 0.1 ma 52 ma up to 10 Ω/ 0.001 Ω 1.6 mω >10 Ω to 100 Ω/ 0.001 Ω 4.3 mω up to 1 kω/ 0.01 Ω 31 mω up to 10 kω/ 0.1 Ω 306 mω up to 100 kω/ 1 Ω 3.1 Ω up to 1 MΩ/ 0.01 kω 35 Ω up to 10 MΩ/ 0.1 kω 1.5 kω up to 100 MΩ/ 1 kω 53 kω up to 10 nf/ 0.01 nf 36 pf up to 100 nf/ 0.1 nf 355 pf up to 1 µf/ 1 nf 3.7 nf up to 10 µf/ 0.01 µf 36 nf up to 100 µf/ 0.1 µf 557 nf up to 1000 µf/ 1 µf 5.6 nf up to 10 mf/ 0.01 mf 56 µf up to 100 mf/ 0.1 mf 1.2 µf up to 10 Hz/ 0.00001 Hz 12 mhz up to 100 Hz/ 0.0001 Hz 14 mhz > 100 Hz to 900 Hz/ 0.0001 Hz 29 mhz up to 5 khz/ 0.001 Hz 116 mhz up to 50 khz/ 0.01 Hz 981 mhz up to 500 khz/ 0.1 Hz 1.5 Hz up to 1M Hz/ 0.001 khz 2 Hz >1 MHz to 10 MHz/ 0.001 khz 19 Hz up to 50 MHz/ 0.01 khz 97 Hz up to 100 MHz/ 0.1 khz 194 Hz >100 MHz to 300 MHz/ 0.1 khz 581 Hz Up to 40 A/ 0.01 A 341 ma up to 100 A/ 0.1 A 648 ma >100 A to 400 A/ 0.1 A 2.5 A up to 750 A/ 1 A 4.4 A >750 A to 1000 A/ 1 A 5.7 A Calibrator Fluke 5500A+300MHz Scope Calibrator Fluke 5522A+ 50 Turn Coil 50 Hz Up to 40 A/ 0.01 A 479 ma up to 100 A/ 0.1 A 825 ma Calibrator Fluke Page 4 of 7
100 Hz DC Voltage - AC Voltage - 60Hz 1kHz 100kHz DC Current - AC Current - 60Hz >100 A to 250 A/ 0.1 A 2.3 A 5522A+ 50 Turn Coil >250 A to 400 A/ 0.1 A 3.2 A up to 750 A/ 1 A 5.2 A >750 A to 1000 A/ 1 A 6.7 A Up to 40 A/ 0.01 A 673 ma up to 100 A/ 0.1 A 1.3 A >100 A to 250 A/ 0.1 A 3.4 A >250 A to 400 A/ 0.1 A 4.9 A up to 750 A/ 1 A 8.5 A >750 A to 1000 A/ 1 A 11 A up to 100 mv/ 0.001 mv 1.6 µv up to 1 V/ 0.01 mv 7.7 µv 71 µv 855 µv 18 mv up to 100 mv/ 0.001 mv 70 µv up to 1 V/ 0.01 mv 700 µv 7 mv 70 mv up to 750 V/ 0.01 V 762 mv up to 100 mv/ 0.001 mv 30 µv up to 1 V/ 0.01 mv 301 µv 3 mv 40 mv up to 750 V/ 0.01 V 650 mv up to 100 mv/ 0.001 mv 680 µv up to 1 V/ 0.01 mv 6.8 µv 68 mv 41 mv up to 1 µa/ 1 na 581 pa >1 µa to 10 µa/ 1 na 629 pa >10 µa to 100 µa/ 1 na 2.4 na up to 1 ma/ 0.01 µa 21 na up to 10 ma/ 0.1 µa 208 na up to 100 ma/ 1 µa 3.6 µa up to 1 A/ 0.01 ma 110 µa up to 5 A/ 1 ma 30 ma Electrical >5 A to 10 A/ 1 ma 45 ma Tester Calibrator >10 A to 20 A/ 1 ma 75 ma up to 100 µa/ 1 na 90 na Page 5 of 7
1kHz Resistance - High Voltage AC/DC Insulation Resistance up to 1kV Insulation Resistance up to 5kV Low Voltage Resistance/ Earth Tester up to 1 ma/ 0.01 µa 813 na up to 10 ma/ 0.1 µa 8 µa up to 100 ma/ 1 µa 80 µa up to 1 A/ 0.01 ma 1 ma up to 5 A/ 1 ma 30 ma Electrical >5 A to 10 A/ 1 ma 45 ma Tester Calibrator >10 A to 20 A/ 1 ma 75 ma up to 100 µa/ 1 na 90 na up to 1 ma/ 0.01 µa 500 na up to 10 ma/ 0.1 µa 5 µa up to 100 ma/ 1 µa 50 µa up to 1 A/ 0.01 ma 1.2 ma up to 5 A/ 1 ma 30 ma Electrical >5 A to 10 A/ 1 ma 45 ma Tester Calibrator >10 A to 20 A/ 1 ma 75 ma up to 99 Ω/ 0.01 Ω 6 mω >99 Ω to 999 Ω/ 0.01 Ω 161 mω >0.999 kω to 10 kω/ 0.01 Ω 255 mω >10 kω to 100 kω/ 0.01 Ω 1.2 Ω >100 kω to 1000 kω/ 0.01 Ω 17 Ω up to 10 MΩ/ 1 kω 833 Ω up to 25 kv 50 Hz/ 0.2 Kv 0.15 kv HV Probe Fluke 80k-40 Up to 40 kv/ 0.1 kv 0.13 kv with 40 kω to 99.99 kω/ 0.1 kω 0.6 kω 0.1 MΩ to 0.999 MΩ/ 0.001 MΩ 0.004 MΩ 1 MΩ to 99 MΩ/ 0.1 MΩ 0.56 MΩ 0.1 GΩ to 10 GΩ/ 0.01 GΩ 0.09 GΩ 100 Fixed GΩ/ 1 GΩ 3.1 GΩ 350 MΩ to 999 MΩ/ 1 MΩ 9.3 MΩ 1 GΩ to 9.9 GΩ/ 0.01 GΩ 0.093 GΩ 10 GΩ to 199.9 GΩ/ 1 GΩ 3.8 GΩ 200 GΩ to 999.9 GΩ/ 1 GΩ 19 GΩ 0.1 Ω to 4.99 Ω/ 0.01 Ω 0.03 Ω 5 Ω to 99.99 Ω/ 0.1 Ω 0.2 Ω 100 Ω to 999.9 Ω/ 1 Ω 1.7 Ω 1 kω to 10 kω/ 0.01 kω 0.15 kω Thermal Digital Thermometer, Temp. Gauge, Thermocouple Probe, RTD Probe >140 C to 400 C/ 0.001 C >400 C to 700 C/ 0.001 C up to 900 C/ 0.01 C 0.07 C 1.2 C 3 C Calibration Bath, -40 C to 400 C/ 0.001 C 0.04 C with HV Adaptor/ Resistance Multiplier -40 C to 140 C/ 0.001 C 0.03 C Fluke 1521&5615-12 Reference PRT Probe with Readout Platinum Resistance Thermometer Fluke 5624, with Page 6 of 7
Dry Block HP 34401A up to 900 C/ 0.01 C 0.23 C Calibrator Temperature Pt100-200 C to 600 C/ 0.001 C 0.15 C Fluke 5522A & Thermocouple K HP34401A 6.5Digit 0.41 C Thermocouple J 0.30 C Temperature by Electrical Simulation Pt100-200 C to 600 C/ 0.001 C 0.13 C Fluke 5522A Thermocouple K 0.41 C Thermocouple J 0.30 C Temperature Calibrator- Electrical Digital thermometer Simulation read out Fluke 1529 / ment Fluke 5522A Pt100-200 C to 600 C/ 0.001 C 0.06 C Thermocouple -K /J s 0.43 C 1 Calibration and ment Capability is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation (at a confidence level of 95% with a coverage factor of 2) Page 7 of 7