Example: Concentration to be measured 1.6 ppm x 1.5 = 2.4 -> recommended sensor with a measuring range of 5 ppm. Ambient temperature: C

Similar documents
TARAtec P9. Data Sheet

TARAline CS4. Data Sheet

TARAsens AS2 / AS3. Data Sheet. indicator

Measuring and Controlling Unit Multronic

Measuring and Controlling Unit Multronic OC

ph or ORP Transmitter

Screw-in resistance thermometers with plug connector

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Inductive Conductivity Meter ILM

ABB ph/orp analyzer and probe package

Magnetic Inductive Flow Sensors VMI Series

Drinking water monitoring

ProMinent D1Cb and D1Cc Analyzers

The transducer component converts the measured signal and displays the actual value.

LENORD. +BAUER... automates motion. GEL 295x Customer-specific precision encoder. Technical Information Version General information.

Rosemount TM 498CL ph-independent Free Chlorine Sensor

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

Conductivity Transmitter

Temperature Sensor for Build-In System G3/8" FLEXadapt

Temperature Sensor for Build-In System G3/8" FLEXadapt

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Temperature Sensor Tri-Clamp

Digital conductivity transmitter

OPERATING MANUAL. ba15358e03 09/2014 F 500 DIN, F 500 BNC F 800 DIN, F 800 BNC FLUORIDE SENSITIVE ELECTRODE

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

JUMO CTI-500. Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Type Brief description.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Temperature Sensor with M12 hygienic

ENCODER. Analog Multiturn Encoder. Serie 8.M3661/M3681. Key-Features:

LVDT. Inductive Position Transducer. SLX-series. designed for pharmaceutical, medical and food industry. content: Key-Features:

OPTISYS CL 1100 Technical Datasheet

SMARTPAT PH 1590 Technical Datasheet

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable)

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Magnetic Inductive Flow Sensors induq. Series VMI

Temperature Sensor Tri-Clamp

OPTISENS PH 8390 Technical Datasheet

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

WS12EX Position Sensor with Analog output Dust explosion-proof

20 General technical data XI/ON

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

Digital inductive conductivity transmitter

DPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter

Technical Information Memosens CCS50D

The electronic anti-scale system

SILICon IrrADIAnCe SenSor

LINEAR POTENTIOMETER. LZW Series. Key-Features:

Process displays For standard signals, temperature, resistance measurement

Pharma Temperature Sensor G3/8"

Magnetic-Inductive flow Meter fmi

Temperature Sensor with M12 hygienic

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

XXXX e. X d.. X X X a

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

C4E NUMERICAL SENSOR User manual

RSMFX-2R MULTIFUNCTIONAL

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Indoor, outdoor and duct resistance thermometers

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

B850 Boiler House Energy Monitor

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

Metal Finishing. W600 Series Controllers. Summary of Key Benefits

MaxxFlow HTC. Product Information. Flow Measurement for Dry Bulk Solids

Electromagnetic Flow Transmitter

OPTISENS ORP 8590 Technical Datasheet

Inductive conductivity transmitter JUMO CTI-Junior

Operating Instructions for Microwave Level Switch. Model: LNM

P5201 Universal Programmable Transmitters with Galvanic Isolation

Rebuild 19mm & 25mm Sensors

400 (±2,5 V/ V/ ,3% V4A

OPTISENS PH 8100 Technical Datasheet

MaxxFlow HTC Flow measurement for dry bulk solids

WATERFLUX 3000 Quick Start

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

SONO 1500 CT Ultrasonic flow sensor

Industrial Pressure Transmitter

ph / ORP Measurement mypro CPM 431

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Valve Island with Electronic I/O

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

OPTIFLUX 5000 Technical Datasheet

Level Sensors Reed Contact Chain

Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts

Palm-sized, 16-channel Relay Terminals

TIDALFLUX 2300 F Technical Datasheet

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Universal measuring transducer

Electronically controlled proportional pressure regulating valves

B850 Boiler House Energy Monitor

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Transcription:

TARAtec P10 indicator Application system Electronic Information about the measuring of sensors with 4-20 ma Working temperature Temperature compensation Max. allowed working pressure Flow rate Peracetic acid All kinds of water treatment, also sea water Conductivity acids are tolerated. (e. g. bottle washing machine, CIP-plants) The membrane system is mechanical resistant. The membrane system is highly resistant to surfactants (tensides). Membrane covered, amperometric 2-electrode system Analog version: Digital version: ma-version: - voltage output - not galvanically isolated electronics - analog internal data processing - output signal: analog (analog-out/analog) - electronic is completely galvanically isolated - digital internal data processing - output signal: analog (analog-out/digital) or digital (digital-out/digital) - current output analog - not galvanically isolated electronics - output signal: analog (analog-out/analog) Slope of a sensor can vary production-related or application-related between 65% and 150% of the nominal slope -> Recommendation to determine the suitable measuring or the suitable sensor: Concentration to be measured x factor 1.5 = measuring of the sensor Example: Concentration to be measured 1.6 ppm x 1.5 = 2.4 -> recommended sensor with a measuring of 5 ppm water temperature: 0 +45 C (no ice crystals in the measuring water) Ambient temperature: 0 +55 C Automatically, by an integrated temperature sensor sudden temperature changes must be avoided Response time t 90 = approx. 8 min. Operation without retaining ring: 0.5 bar, no pressure impulses and/or vibrations Operation with retaining ring: 1.0 bar, no pressure impulses and/or vibrations approx. 15-30L/h in TARAflow FLC, small flow rate dependence is given ph- ph 1 ph 6 page 1 / 6

TARAtec P10 Run-in time Response time Zero point adjustment P10H: P10N: P10L: First start-up approx. 3 h First start-up approx. 1 h First start-up approx. 30 min. T 90: approx. 5 min. at 10 C T 90: approx. 1.5 min. at 45 C Not necessary Slope calibration interferences influence of conductivity acids Absence of the disinfectant At the device, by analytical determination O 3: factor 2500 ClO 2: factor 1 H 2O 2: very low influence on the measuring value (reduce of the PAA-signal) 1 % sulfuric acid, 1 % nitric acid or 1 % phosphoric acid in the water have no influence to the measuring behaviour Max. 24 h analog-out/analog version: 4-pole plug adapter analog-out/digital version: 4-pole plug adapter digital-out/digital version: 5-pole M12, plug-on flange 4-20 ma version: 2-pole terminal or 5-pole M12, plug-on flange material PVC-U, stainless steel 1.4571 Size diameter: approx. 25 mm Length: analog-out/analog version approx. 175 mm analog-out/digital version approx. 195 mm digital-out/digital version approx. 205 mm 4-20 ma version approx. 220 mm (2-pole-terminal) approx. 190 mm (5-pole-M12) Transport +5 +50 C (Sensor, electrolyte, membrane cap) Sensor: dry and without electrolyte no limit at +5 +40 C storage maintenance Electrolyte: in original bottle protected from sunlight at +5 +35 C min. 1 year or until specified EXP-Date Membrane cap: in original packing no limit at +5 +40 C (used membrane caps can not be stored) Regular control of the measuring signal, min. once a week The following specifications depend on the water quality: Change of the membrane cap: once a year Change of the electrolyte: every 3-6 months EMC-Testing DIN EN 61326-1, 61326-2-3 RoHS compliant page 2 / 6

Technical Data 1. P10 (Analog output, analog internal signal processing) analog-out / analog A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. resolution resistance Nominal slope Voltage supply P10H 0.5 200 ppm 0.1 ppm 0-2000 mv -10 mv/ppm P10N 5 2000 ppm 1 ppm -1 mv/ppm 1 kω 0.005 2 % 0.001 % -1000mV/% P10L (-0.1 mv/ppm) ±5 - ±15 VDC 10 ma 4-pole screw connector P10Up2000 5 2000 1 ppm 0 +2000 mv +1 mv/ppm 10-30 VDC P10Up5000 50 5000 1 ppm 1 kω +0.4 mv/ppm 10 ma 2. P10 (analog output, digital internal signal processing) analog-out / digital - The power supply is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free. Resolution resistance Nominal Slope Power supply P10H-An 0.5 200 ppm 0.1 ppm -10 mv/ppm P10N-An 5 2000 ppm 1 ppm analog 0-2 V (max. -2.5 V) -1 mv/ppm P10L-An 0.005 2% 0.001% 1 kω -1000 mv/% (-0.1 mv/ppm) P10H-Ap 0.5 200 ppm 0.1 ppm +10 mv/ppm P10N-Ap 5 2000 ppm 1 ppm analog 0 +2 V (max. +2.5 V) +1 mv/ppm P10L-Ap 0.005 2% 0.001% 1 kω +1000 mv/% (+0.1 mv/ppm) 9-30 VDC approx. 56-20 ma 4-pole screw connector page 3 / 6

3. P10 (digital output, digital internal signal processing) digital-out / digital - The power supply is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free. Resolution resistance Power supply P10H-M0c 0.5 200 ppm 0.1 ppm P10N-M0c 5 2000 ppm 1 ppm P10L-M0c 0.005 2% 0.001% Modbus RTU There are no terminating resistors in the sensor. 9-30 VDC approx. 56-20 ma 5-pole M12 connector 4. P10 4-20 ma (analog output, analog internal signal processing) Analog-out / analog A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. 4.1 Electrical connection: 2 pole terminal clamp resolution resistance Nominal slope Voltage supply P10MA-200 0.5 200 ppm 0.1 ppm 0.08 ma/ppm P10MA-2000 5 2000 ppm 1 ppm 0.008 ma/ppm 4 20 ma P10MA-5000 50 5000 ppm 1 ppm 0.0032 ma/ppm uncalibrated P10MA-2% 0.005 2 % 0.001 % 8.0 ma/% (0.0008 ma/ppm) 12 30 VDC R L = 50Ω (12V) R L 900Ω (30V) 2-pole terminal (2 x 1 mm²) Recommended: Round cable 4 mm 2 x 0.34 mm² P10MA-5% 0.05 5 % (50000 ppm) 0.01 % (100 ppm) 3.2 ma/% (0.00032 ma/ppm) page 4 / 6

4.2 Electrical connection: 5 pole M12 plug-on flange resolution resistance Nominal slope Voltage supply P10MA-200-M12 0.5 200 ppm 0.1 ppm 0.08 ma/ppm P10MA-2000-M12 5 2000 ppm 1 ppm 0.008 ma/ppm 4 20 ma P10MA-5000-M12 50 5000 ppm 1 ppm 0.0032 ma/ppm uncalibrated P10MA-2%-M12 0.005 2 % 0.001 % 8.0 ma/% (0.0008 ma/ppm) 12 30 VDC R L = 50Ω (12V) R L 900Ω (30V) 5-pole M12 plug-on flange Function of wires: PIN2: +U PIN3: -U P10MA-5%-M12 0.05 5 % (50000 ppm) 0.01 % (100 ppm) 3.2 ma/% (0.00032 ma/ppm) Spare Parts Type Membrane cap Electrolyte Emery O-ring For all P10H For all P10N P10Up2000 EPS9H/W, 100 ml Art. No. 11025 P10Up5000 For all P10L For all P10MA-200 M10.1N with G-holder Art. No. 11046.1 EPS9L/W, 100 ml Art. Nr. 11024 S2 Art. No. 11906 20 x 1.5 silicone Art. No. 11803 For all P10MA-2000 EPS9H/W, 100 ml Art. No. 11025 For all P10MA-5000 For all P10MA-2% For all P10MA-5% M10G with G-holder Art. No. 11041 EPS9L/W, 100 ml Art. No. 11024 EPS7/W, 100 ml Art. No. 11020 Reiss GmbH Elektrochemische Messtechnik Eisleber Str. 5 D 69469 Weinheim Germany page 5 / 6

Slope of P9 and P10 versus ph 160 140 120 Temperature: 25 C / Flow rate: 30 l/h ph regulation ph - : H 2 SO 4 ph + : NaOH Slope [%] 100 80 60 40 20 0 4 5 6 7 8 ph value St eilheit _des_p9 _Sen sor s_in _abhä n gigkeit _vom_ph- Wer t. xls page 6 / 6